The VLT Micro Drive Small drive maximum strength and reliability

Similar documents
VLT Micro Drive. Ready Set Go!

VLT Micro Drive. Small drive maximum strength and reliability

MAKING MODERN LIVING POSSIBLE. VLT Micro Drive. Small drive maximum strength and reliability

Small, powerful and built to last Save panel space and reduce installation costs

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

50% VLT HVAC Basic Drive a compact and competitive solution for applications with basic needs. energy costs savings

50% Energy costs savings. A compact and competitive solution for applications with basic needs.

CATALOG SELECTION / PRODUCT SELECTION

Drives and Soft Starters For machine and plant automation

VLT The general purpose drive. Phone: Fax: Web: -

Built-in features Built-in simplicity Built for fans & pumps

Selection guide VLT AutomationDrive FC 360

98% Selection Guide 0.25 kw 400 kw VLT AutomationDrive FC 301/ Energy efficiency MAKING MODERN LIVING POSSIBLE

VLT AutomationDrive FC 300

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

SD250 VARIABLE SPEED DRIVE

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Operating comfort redefined Frequency Inverters M-MAX

98% Selection Guide 0.25 kw 250 kw VLT AutomationDrive FC 301/302. Energy efficiency

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

450 kg. High performer in challenging environments. force at 0.6 Hz. Selection guide VLT AutomationDrive FC

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ABB component drives ACS150, 0.37 to 4 kw / 0.5 to 5 hp

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

VLT 2800 DRIVE SPECIFICATIONS

ABB Component Drives ACS55, 0.25 to 3 Hp

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

CI-tronic Reversing contactor Type RCI

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

VLT AutomationDrive FC 360

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

HVAC Products. Introducing the SED2 Variable Frequency Drives

UNIDRIVE M200. Manufacturing Automation drives. Flexible machine integration through communications

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

PowerFlex 400 AC Drive Guide Specification

Built-in features Built-in simplicity

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Master the elements in building automation siemens.com/sinamics-g120x

Easy To Use OEMS Take Note

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

Simply Smart! Altivar to 600V AC / 1 & 3-phase / 0.25 to 20HP. All in a high performance package! Easy to Use, Plug and drive!

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Voltage Current Front-mounting bracket

MCX08M2 Programmable controller

ABB Industrial Pump and Fan AC Drives ACS310, 0.5 to 30Hp (0.37 to 22kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Commander SX NEMA 4X Washdown Duty Drive

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

100% full load factory tested. VLT AutomationDrive Reliable simplicity to keep your business running smoothly.

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ABB general machinery drives ACS350, 0.5 to 10 hp

Unidrive M200 Integration through flexible communications

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

60131/2 Te ESC ENT RUN ESC ENT RUN ESC ENT RUN ESC ENT RUN ESC ENT RUN. stop reset FWO REV. stop reset FWO REV. stop reset FWO REV. stop reset FWO REV

For additional PowerFlex 4M data and general drive information, refer to the following publications:

ATV660C16Q4X1 Compact Drive System ATV /132kW V - IP23

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS

MC Series Drives. Flexible, simple, rugged, robust!

PowerFlex 40 Sample Specification

VLT The Real Drive for HVAC. The VLT 6000 is a. totally new adjustable. frequency drive, with. control functions and. software designed solely

VLT Integrated Servo Drive ISD 510 flexible and open system

Bulletin 817 Thermistor Protection Relay

Section 16. Drives AF-650GP General Purpose Drive. Standard Specifications. Environmental Conditions. Logic Controller (LC) Sequencer

VARIABLE SPEED DRIVES VLA1 SERIES

DeltaV Bulk Power Supplies

Q9 ASD LOW VOLTAGE DRIVE

SENSORLESS VECTOR CONTROL

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

Transcription:

MAKING MODERN LIVING POSSIBLE The VLT Micro Drive Small drive maximum strength and reliability

Ready Set Go! Connect motor and power cables, turn the control knob, and watch the motor speed change. 12 1 11 13 14 5 6 4 3 6 7 9 12 13 10 8 11 Manufactured to the highest quality standards The VLT Micro Drive is a UL-listed product made in an ISO 9001-2000 certified facility. 2 1 Well protected IP20 enclosure with NEMA/UL Type 1 kit optional No forced airflow through electronics 2 Removable cover for convenient access to control terminals 8 Potentiometer 9 EIA-485 connection 3 High quality capacitors 10 Customer relay screw terminals Wire inlet from the bottom 4 RFI Filter 11 Safety ground Min. 10 AWG accessible from front 5 DC-link access 12 I/O terminals 6 Hot-pluggable LCP 13 Mains screw terminals 7 LCD display 14 Motor screw terminals 2 11/2011

Compact VLT quality The VLT Micro Drive is a genuine VLT variable frequency drive with unsurpassed reliability, user-friendliness and condensed functionality that is extremely easy to commission. Terminal numbers are named in the same manner as in the rest of the VLT family. It s developed and manufactured by Danfoss Drives, the leading drives experts since 1968 and creators of the VLT Series, the world s first mass-produced variable frequency drive. User friendly Plug-and-play Streamlined installation Minimal commissioning requirements Quicker startup Settings can be copied via the local control panel Easy setup of multiple drives Intuitive parameter structure Minimal manual reading Faster startup and greater control of Compatible with MCT 10 Setup Software large installations Reliable Optimal heat dissipation Longer lifetime High quality electronics/capacitors Low lifetime cost All drives full-load tested from factory High reliability Ground fault, temperature and short circuit protection High level of protection without the need for external devices Circuit boards well protected and coated Increased robustness Inputs and outputs 5 programmable digital inputs PNP/NPN selection Pulse input 20 5000 Hz 1 analog input (0 10 V or 0 20 ma) 1 analog input 0 20 ma Thermistor input (analog/digital) 1 analog output 0 20 ma 1 Relay 240 VAC, 2 A EIA-485 port with FC or Modbus RTU protocol Small drive high performance Despite its compact size and ease of installation, the VLT Micro Drive can deliver exceptional performance even in complex applications. Approximately 100 parameters are available to optimize energy efficiency and operation. Process PI controller Removes need for external controller Automatic Energy Optimization (AEO) Lowers energy consumption Automatic Motor Adaptation (AMA) Utilizes motor s full potential 150% motor torque up to 1 minute Removes need for bigger drive Flying start (catch a spinning motor) Provides smooth starts without tripping Electronic Thermal Relay (ETR) Replaces external motor protection Smart Logic Controller Often makes PLC unnecessary Built-in RFI filter Minimizes radio frequency disturbances Compact general purpose drive The VLT Micro Drive is a general purpose drive designed to control AC motors up to 30 HP. 11/2011 3

Compact design Uncompromised quality Ensured reliability and maximum uptime True side-by-side mounting A compact bookstyle design allows spacesaving mounting without derating. Built-in brake functions With built-in DC and AC brake functions, the VLT Micro Drive can transform kinetic energy in the application into braking. power to slow the motor. A brake chopper is built into all VLT Micro drives 2 HP and up. Minimal penetration of dust The VLT Micro Drive is designed to separate forced ventilation air from the electronics. Printed circuit boards are well protected inside the drive. Built-in RFI protection A built-in RFI filter limits radio disturbance from motor cables, allowing for 45 motor cables (shielded). Designed for robust operation in a variety of applications Coated electronics are standard All VLT Micro Drives come with conformally coated circuit boards for greater longevity and reliability. Energy efficiency 98% High-quality VLT power modules ensure low power losses, resulting in cooler operation. Intelligent heat management Heat from the power semiconductors is transferred through the heatsink to the external airflow, which is routed through the cooling fins. This minimizes the air exchange inside the enclosure and protects the control circuitry from dirt and other contaminants. 104 F (40 C) ambient temperature 122 F (50 C) maximum with derating Highly efficient cooling allows for operation in high ambient temperatures. Built-in Smart Logic Controller The smart logic controller is a simple, clever way to enable the drive, motor and application to work together. The smart logic controller is able to monitor any parameter that can be characterized as true or false. This includes digital commands and also logic expressions, which allows even sensor outputs to influence the operation. Temperature, pressure, flow, time, load, frequency, voltage and other parameters combined with the operators >, <, =, and and or form logic expressions that are false or true. 4 11/2011

Hot-pluggable display Packed with features LCP copy function transfer parameter settings from one drive to another Parameter numbers and values visible simultaneously Unit indications (A., V, Hz, RPM, %, s, HP and kw) Rotation direction indication Setup and status indications Removable during operation Quick Menus Easy access to parameters commonly used in startup procedures PI controller parameters grouped for easy access Large, bright display Easy to read from a distance Operation buttons illuminated when active User-friendly menu structure Uses the same familiar and proven format as other VLT Series drives Easy shortcuts for the experienced user Edit and operate in different setups simultaneously Remote mountable Illuminated LCD display Navigation buttons Indicators Operation buttons Two control panels are available for either local or remote mounting: LCP 11 with UP/DOWN buttons for speed setting (NEMA/UL Type 12 protection when remotely mounted) LCP 12 with rotary potentiometer for speed setting (NEMA/UL Type 1 protection) Control panels shown actual size: 3.3 H x 2.6 W x 0.8 D (D = 1.1 with potentiometer) That is why Danfoss calls it a logic controller. As a result, you can program the controller to react on literally any event. 11/2011 5

Connections EIA 485 (N EIA 485) (P EIA 485) (COM EIA 485) EIA 485 Factory settings Accessories Remote mounting kit A dedicated mounting kit is available for mounting the local control panel (LCP) in a cabinet door. Includes 10 cable. Part #132B0102. Options DESCRIPTION VLT LCP 11 w/o potentiometer VLT LCP 12 with potentiometer. Remote Mounting Kit for LCP NEMA 1 kit for M1 frame NEMA 1 kit for M2 frame NEMA 1 kit for M3 frame NEMA 1 kit for M4 frame NEMA 1 kit for M5 frame Decoupling plate kit For M1 and M2 frames Decoupling plate kit For M3 frame Decoupling plate kit For M4 and M5 IP21 for M1 frame IP21 for M2 frame IP21 for M3 frame DIN Rail mounting kit for M1 and M2 PART NUMBER 132B0100 132B0101 132B0102 132B0103 132B0104 132B0105 132B0120 132B0121 132B0106 132B0107 132B0122 132B0108 132B0109 132B0110 132B0111 6 11/2011

Specifications Mains supply (L1, L2, L3) Supply voltage 1 x 200 240 V ±10% Supply voltage 3 x 200 240 V ±10% Supply voltage 3 x 380 480 V ±10% On-board power supply Output voltage Max. load (10 V) Max. load (24 V) 10.5 ± 0.5 V 15 ma 130 ma Output data (U, V, W) Output voltage Output frequency Output frequency Switching on output Ramp times 0 100% of supply voltage 0 200 Hz (VVC+ mode) 0 400 Hz (V/Hz mode) Unlimited 0.05 3600 sec. Digital inputs Programmable inputs 5 Logic PNP or NPN Voltage level 0 24 V Maximum voltage on input 28 V DC Input Resistance, Ri Approx. 4 kω Pulse inputs Programmable pulse inputs 1 Voltage level 0 24 V DC (PNP positive logic) Pulse input accuracy (0.1 110 khz) Max. error: 0.1% of full scale Pulse input frequency 20 5000 Hz Analog input Analog inputs 2 Modes 1 current/1 voltage or current Voltage level 0 10 V (scaleable) Current level 0/4 (scaleable) Analog output Programmable analog outputs 1 Current range at analog output 0/4 20 ma Max. load to common at analog output 500 Ω Accuracy on analog output Max. error: 1% of full scale Frame Sizes (mounting flange incl.) M1 [inches] M1 M2 M3 M4 M5 Height 5.90 6.92 9.41 11.49 13.18 Width 2.76 2.95 3.54 4.92 6.49 Depth 5.82 6.61 7.63 9.48 9.76 +.236 (1/4 ) inch with Potentiometer M2 M3 M4 M5 Relay outputs Programmable relay outputs 1 Max. terminal load 240 VAC, 2 A Cable lengths Max. motor cable length, shielded Max. motor cable length, unshielded Surroundings/ External Enclosure Vibration test Max. relative humidity Aggressive environment Ambient temperature 24-hour average Ordering code numbers 200-240 V 440-480 V Power [HP] Current ( I ) 1-phase 3-phase Current ( I ) 3-phase 1/4 1.2 132F0001 - - - 1/3 1.5-132F0008 - - 1/2 2.2 132F0002 132F0009 1.1 132F0017 1 4.2 132F0003 132F0010 2.1 132F0018 2 6.8 132F0005 132F0012 3.4 132F0020 3 - - 4.8 132F0022 3 9.6 132F0007 132F0014 - - 4 - - 6.3 132F0024 5 15.2-132F0016 8.2 132F0026 7.5 11 132F0028 10 14 132F0030 15 Micro drives 2 HP and up 21 132F0058 20 have built-in brake chopper 27 132F0059 25 34 132F0060 30 40 132F0061 50 164 IP20 standard; NEMA/UL Type 1 and IP21 optional 0.7 g 5% 95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation (IEC 721-3-3), coated class 3C3 Max. 122 F Max. 104 F Protection and features Electronic thermal motor protection against overload Temperature monitoring of the heat sink protects the drive from overheating The drive is protected against short-circuits on motor terminals U, V, W The drive is protected against ground fault on motor terminals U, V, W 11/2011 7

EnVisioneering As a world leader in components and solutions, Danfoss meets our customers challenges through EnVisioneering. This approach expresses our views on engineering innovation, energy efficiency, environmental responsibility and sustainable business growth that creates strong customer partnerships. This vision is realized through a global production, sales, and service network focused on refrigeration, air conditioning, heating and water, and motion control. Through EnVisioneering, Danfoss is Making Modern Living Possible. Danfoss EnVisioneering : Engineered solutions to improve performance and profitability Energy efficiency to meet higher standards and to lower operating costs Environmental sustainability to provide a financial and social payback Engaged partnerships to foster trust, reliability, and technological superiority Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss VLT Drives 4401 N. Bell School Rd. Loves Park, IL 61111, USA Phone: 1.800.432.6367 1.815.639.8600 Fax: 1.815.639.8000 Copyright 2011 by Danfoss 11/11 Danfoss VLT Drives 8800 W. Bradley Rd. Milwaukee, WI 53224, USA Phone: 1.800.621.8806 1.414.355.8800 Fax: 1.414.355.6117 Rev. B 176R0600