Thermocouple Signal Conditioners

Similar documents
Industrial Wet/Wet Differential Pressure Transducer

HIGH PERFORMANCE STEPPER DRIVES

Digital Panel Meters

SUPPLEMENTARY PROTECTORS

Clamp-On Digital Multimeters

Conductivity Transmitters

Microprocessor Based Portable Universal Circular Chart SUPERECORDER

Expandable Modular Data Acquisition System inet-400 Series

Temperature, Process &

INTEGRATED STEPPER DRIVES/MOTORS WITH ADVANCED FEATURES AND CONTROL OPTIONS. ADVANCED FEATURES Auto Set-Up:

Embedded Internet. M (0)

WEB-ENABLED GRAPHIC OPERATOR INTERFACE TERMINALS

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

ELC PROGRAMMABLE LOGIC CONTROLLERS AND MODULES

Temperature, Process &

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

User s Guide. DIN-190 and DIN-192 Series. Converter Boxes. Shop online at

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Meter Scanner & Controller

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

User s Guide TSD600. Shop online at omega.com SM. For latest product manuals: omegamanual.info

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

User s Guide TX69. Universal Smart Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

FMA-7400/7500 Series Configurator

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

GEN II Wireless GSM/GPRS Data Acquisition System

The new Expert Logger 400: Industry 4.0 ready!

Eurotherm advanced controllers providing solutions for simple to demanding applications...

HIGH ACCURACY PRESSURE TRANSDUCERS

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

A NEW DATA LOGGER Stand alone. Secure. Fast.

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

ENVIRONMENTAL MONITORING & CONTROL

User s Guide LDN-PS. Shop online at. omega.com For latest product manuals: omegamanual.info. solartron

LAUREL ELECTRONICS, INC.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

Expanding the Basic GL7000 Configuration

NF770 Temperature Compensation Liquid Flow Computer

DIN-Rail Mounted Ultrasonic Flow Meter

8 or 16 Channel Universal Input Touch Screen Data Logger

NF760 Batch Controller

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

User s Guide. idrn-ps-1000 UNIVERSAL SWITCHING POWER SUPPLY Compact DIN-Rail 24 Volt USA. Shop on line at.

8B SLX300 Data Acquisition System

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

User s Guide D6000 SERIES. Digital Transmitters Modbus RTU, RS-485 Output. Shop online at omega.com

User s Guide WTC Shop online at. Wind Tunnel Controller. omega.com For latest product manuals: omegamanual.

MID approval no. DE-08-MI004-PTB004 Date of release

ENVIRONMENTAL MONITORING & CONTROL

Laurel Electronics Customer Price List

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

SX90 Process Controller

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Your Complete Source for Control, Measurement, and Sensing for the following Industries:

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

User s Guide HHM250. AC Clamp Meter. Shop online at. omega.com For latest product manuals: omegamanual.info MADE IN TAIWAN

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

C100 Portable Multifunction

Digital Indicator Solutions

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

Real Time Electronic Acquisition & Monitoring. & Human Machine Interface REAM HMI. For Pumping Services

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

PTU300 Combined Pressure, Humidity and Temperature Transmitter

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

VersaMax Micro and Nano Technical Product Presentation

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PMA Rail Line. Product Brochure.

User s Guide. CSi32. Benchtop Controller. Shop online at omega.com. For latest product manuals:

User s Guide DRSL-DC4. Bipolar Isolated DIN Rail Signal Conditioner. Shop online at omega.com

User s Guide Servicing North America:

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

User s Guide. CSi8DH SERIES. Benchtop Controllers. Shop online at. omega.com For latest product manuals: omegamanual.

Trident and Trident X2 Digital Process and Temperature Panel Meter

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

User s Guide HHM-MG300. Wireless TRMS Multimeter and Insulation Tester. Shop online at omega.com

Product Brochure PMA KS Multi-function Controller.

User s Guide. DPU90-CT PC COMM / Sensor Configuration Tool

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

Max. I/O units. consumption

Transcription:

Thermocouple Signal Conditioners idrx-tc Starts at 168 NEWPORT TM OMEGA manufactures thousands of thermocouple probes. Please see page 2 or visit omega.co.uk T/C Types J, K, T, E, R, S, B, N, J DIN 0.1 C Resolution ±1 C Accuracy 250 V/1 Min. Input Overvoltage Protection Factory Setup and Configuration Available at No Charge (for idrn s) The idrn-tc and idrx-tc signal conditioners provide highly accurate, stable, isolated measurement of thermocouple sensors. Thermocouple types are selected and the outputs are scaled with the free configuration software, or can be done at the factory for no additional charge. The T/C Signal Conditioners can accept 9 different thermocouple types: J, K, T, E, R, S, B, N, and J DIN. 2 Models (Analogue or Digital Outputs) idrn-tc provides an analogue output that is proportional to the input signal. The idrx-tc uses a digital RS-485 communication link. The output of idrn-tc can be user set for 0 to 10 V, 4 to 20 ma or 0 to 20 ma. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the free Windows-based setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (idrn ) Thermocouple Type Temperature High & Low Output Value High & Low Example: Type J, 0 C = 4 ma, 100 C = 20 ma The idrx-tc is a digital signal conditioner which communicates over an RS-485 communication link using either a simple, straightforward ASCII Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters. The Optional EIS-2B iserver module can connect up to thirty-two idrx RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iserver can also be used as a Covered by U.S. and International patents and simple Serial to Ethernet bridge pending applications. or converter to connect a single idrn RS-232 device to an Ethernet network and the Internet. Accuracy at 25 C: ±1 C Resolution: 0.1 C Power Consumption: 2 W (84 ma @ 24 Vdc) Input Types: J, K, T, E, R, S, B, N, J DIN Input Ranges: See range chart RS-485 (OMEGA serial protocol and MODBUS serial protocol) idrn Output: 0 to 10 V @ 10 ma max; 0 to 20 ma or 4 to 20 ma, 10 V compliance Thermocouple Default settings idrn: Input Type K, Range 0 to 1000 F; Output 4 to 20 ma (custom settings available at no charge) 333 Input Type Range, C Range, F -210 to 760-346 to 1400-270 to 1372-454 to 2500-270 to 400-454 to 752-270 to 1000-454 to 1832 / -50 to 1768-58 to 3214 100 to 1820 212 to 3300-270 to 1300-454 to 2372-200 to 900-328 to 1652 idrx-tc 168 Digital signal conditioner with RS-485 output for Thermocouple sensors idrn-tc 218 Signal conditioner with analogue output for thermocouple sensors idrn-ps-1000 101 DIN rail mount power supply, 95 to 240 Vac inout, 24 Vdc output @ 850 ma (powers 7 units) Ordering Example: idrn-tc, signal conditioner, and DB9-RJ12, connector adaptor, 218 + 20 = 238. TRANSMITTERS

RTD Signal Conditioners NEWPORT TM idrx-rtd Starts at 168 100Ω Pt, 500Ω Pt, 1000Ω Pt 0.1 C Resolution ±0.5 C Accuracy Factory Setup and Configuration Available at No Charge (for idrn Analogue Output models) The idrn-rtd and idrx-rtd signal conditioners provide highly accurate, stable, isolated measurement of RTD temperature sensors. Both models can accept 2, 3, or 4 wire 100Ω PT, 500Ω PT and 1000Ω PT RTDs. 2 Models (Analogue or Digital Outputs) The idrn-rtd provides a fully scalable analogue output that is proportional to the input signal. The idrx-rtd uses digital RS-485 communications. Analogue Model Output The output of the idrn-rtd can be user set for 0 to10 V, 4 to 20 ma or 0 to 20 ma. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the Windows-based setup software. Once configured the settings may be stored in nonvolatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (idrn ) Type and resistance Temperature high and low Output Value high and low Example: Type Pt100; 0.00385; 4-wire; 0 C = 4 ma, 100 C = 20 ma Covered by U.S. and International patents and pending applications. The idrx-rtd is a digital signal conditioner which communicates Accuracy at 25 C: ±0.5 C over an RS-485 communication link Input Types: Platinum RTD, 100Ω, using either a simple, straightforward 500Ω or 1000Ω element (2, 3 or 4 wire, ASCII Serial Protocol or MODBUS 385 or 392 curve) Serial Protocol. Up to 32 modules Resolution: 0.1 C may be connected to a single Power Consumption: 2.4 W RS-485 port stretching up to 1200 m (100 ma @ 24 Vdc) without repeaters. Input Range: -200 to 850 C (-328 to 1562 F) The Optional EIS-2B iserver module RS-485 (NEWPORT Serial Protocol can connect up to thirty-two idrx RS-485 Signal Conditioners to an Ethernet network and the idrn Output: 0 to 10 V @ 10 ma max; Internet using standard TCP/IP 0 to 20 ma or 4 to 20 ma, 10 V protocol. The iserver can also be compliance used as a simple Serial to Ethernet RTD Default settings idrn: bridge or converter to connect a Input PT100, 0.00385, 3-wire, range single idrn RS-232 device to an 0 to 1000 F; Output 4 to 20 ma Ethernet network and the Internet. (custom settings available at no charge) idrx-rtd 168 Digital signal conditioner with RS-485 output for RTD temperature sensors idrn-rtd 238 Signal conditioner with analogue output for RTD temperature sensors Ordering Example: idrn-rtd, digital signal conditioner, and DB9-RJ12, connector adaptor, 238 + 20 = 258. 334 OMEGA manufactures many types of RTD probes. Please see page 74 or visit omega.co.uk

Strain Gauge/Bridge Transducer- Signal Conditioners idrx-st 201 Covered Unipolar/Bipolar 30 mv to 100 mv 13-Bit Resolution 10 Vdc Excitation 0.2% FS Accuracy 250 Vac/1 Min. Input Overvoltage Protection Factory Setup and Configuration Available at No Charge (for idrn Analogue Output models) The idrn-st and idrx-st signal conditioners provide highly accurate, stable, isolated measurement for strain gauge transducers such as load cells, torque transducers, non-amplified pressure transducers, and other bridge based transducers. Both models can accept signals from 30 to 100 mv full scale and provide 10 Vdc reference voltage which may be used for transducer excitation. 2 Models (Analogue or Digital Outputs) The idrn-st provides an analogue output that is proportional to the input signal and the idrx-st uses RS-485 Serial Communications. The output of idrn-st can be user set for 0 to10 V, 4 to 20 ma or 0 to 20 ma. Input scaling and configuration of other operating parameters is accomplished by connecting to a standard RS-232 port of a personal computer and using the free Windowsbased setup software. Once configured the settings may be stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (idrn Analogue Output and RS-232 signal conditioners) Input value high and low Output value high and low Excitation: 10 or 14 Vdc Ratiometric or non-ratiometric Example: 0 V = 4 ma, 100 mv = 20 ma,excitation 10 V, ratiometric NEWPORT TM by U.S. and International patents and pending applications. The idrx-st is a digital signal conditioner which communicates over RS-485 communication link using either a simple ASCII Protocol or MODBUS Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters. The optional EIS-2B iserver module can connect up to 32 idrx RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iserver can also be used as a simple Serial to Ethernet bridge or converter to connect a single idrn RS-232 device to an Ethernet network and the Internet. Accuracy at 25 C: ±0.2% FS Resolution: 13 to 15 bit Excitation: 10 V @ 30 ma Power Consumption: 2 W without excitation (84 ma @ 24 Vdc), 3 W with excitation (125 ma @ 24 Vdc) Input Ranges: 0 to 30 to 0 to 100 mv full scale RS-485 (NEWPORT serial protocol idrn Output: 0 to 10 V @ 10 ma max; 0 to 20 ma or 4 to 20 ma, 10 V compliance Strain Default Settings idrn: Input range 0 to 30 mv; output 4 to 20 ma excitation 10 V ratiometric (custom settings available at no charge) idrx-st 201 Digital signal conditioner for strain gauges and bridge transducers with RS-485 output idrn-st 231 Signal conditioner for strain gauges and bridge transducers with analogue output Ordering Example: idrx-st, digital signal conditioner for strain gauges and bridge transducers with RS-485 output, CAT-285, bi-directional RS-232-RS-485 converter for idrx series, 201 + 99 = 300. 335 OMEGA manufactures many types of Load Cells. Please see page 383 or visit omega.co.uk LCM101 LCMGD LCM1003 TRANSMITTERS

Process Inputs Signal Conditioners idrx-pr 184 NEWPORT TM Unipolar/Bipolar 400 mv to 10 Vdc, 0 to 20 ma dc 11 to 14-Bit Resolution ±0.1% FS Accuracy 14 Vdc Excitation 250 Vac/1 Min. Input Overvoltage Protection (Voltage Input Only) Factory Setup and Configuration Available at No Charge (for idrn Analogue Output models) The idrn-pr and idrx-pr signal conditioners provide highly accurate, stable, isolated measurement of process signals. Both models can accept unipolar and bipolar signals from 400 mv to 10 Vdc full scale, as well as 0 to 20 ma current range. The Signal Conditioners also provide a 10 Vdc or 14 Vdc reference voltage which can be used for transducer excitation. 2 Models (Analogue or Digital Outputs) The idrn-pr provides a programmable analogue output that is proportional to the input signal. The idrx-pr uses a digital RS-485 Serial Communications. The output of idrn-pr can be user set for 0 to 10 V, 4 to 20 ma, or 0 to 20 ma. Scaling and configuration is done with the free software on a PC using either the standard RS-232 port, or an Ethernet connection with the optional EIS-2B module. Once configured the settings are stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (idrn Analogue Output model) Input value high and low Output value high and low Excitation: 10 or 14 Vdc Ratiometric or non-ratiometric Example: 0 V = 4 ma, 10 V = 20 ma, Excitation 10 V, non-ratiometric Covered by U.S. and International patents and pending applications. The idrx-pr is a digital signal conditioner which communicates over an RS-485 communication link using either a simple straightforward ASCII Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters. The optional EIS-2B iserver module can connect up to 32 idrx RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iserver can also be used as a simple Serial to Ethernet bridge or converter to connect a single idrn RS-232 device to an Ethernet network and the Internet. idrx-pr 184 Digital signal conditioner with RS-485 output for process signals idrn-pr 218 Signal conditioner with analogue output for process signals Ordering Example: idrx-pr, digital signal conditioner with RS-485 output for process signals, idrn-ps-1000, power supply, 95 to 240 Vac input, 24 Vdc output @ 850 ma, 184 + 101 = 285. 336 PXM41 Series shown, 302. OMEGA manufactures many types of pressure transducers. Please see page 356 or visit omega.co.uk Accuracy at 25 C: ±0.1% FS Excitation: 14 Vdc @ 25 ma Resolution: 11 to 14-bit Power Consumption: 2 W (84 ma @ 24 Vdc) without excitation, 3 W (125 ma @ 24 Vdc) with excitation Input Ranges: Uni/bipolar, 400 mv to 10 Vdc; 0 to 20 ma RS-485 (NEWPORT Serial Protocol idrn Output: 0 to 10 V @ 10 ma max; 0 to 20 ma or 4 to 20 ma, 10 V compliance Process Default settings DRN: Input Range 0 to 20 ma; Output 4 to 20 ma. Excitation 14 V (custom settings available at no charge)

NEWPORT Frequency/Pulse Digital TM Signal Conditioners idrx-fp 168 Covered Software Selectable Input Type 0 to 50 KHz Frequency Input 2 Million Pulse Capacity Proximity, Switch, Magnetic, Pickup, NAMUR, Contact Closure and Open Collector Input Types RS-485 Output 1800 Vdc Isolation Free Setup and Factory Setup and Configuration Available at No Charge (for idrn Analogue Output models) The idrn-fp and idrx-fp signal conditioners provide accurate, stable, isolated measurement of frequency and pulse signals. Both models measure frequency signals up to 50 KHz and can count up to two million pulses. The idrx-fp and idrn-fp are compatible with a wide variety of transducers including proximity, switch, magnetic pickup, NAMUR, contact closure and open collector transducers. 2 Models (Analogue or Digital Outputs) The idrn-fp provides an analogue output that is proportional to the input signal. The idrx-fp uses digital RS-485 Serial Communication. OMEGA manufactures many types of Flow Transducers. Please see page 487 or visit omega.co.uk by U.S. and International patents and pending applications. The output of idrn-pr can be user set for 0 to 10 V, 4 to 20 ma or 0 to 20 ma. Scaling and configuration is done with the free software on a PC using either the standard RS-232 port, or an Ethernet connection with the optional EIS-2B module. Once configured the settings are stored in non-volatile memory and the unit disconnected from the PC. Factory Setup and Configuration at No Extra Charge (idrn Analogue Output signal conditioners) Input signal or sensor type Input frequency high and low Output value high and low Excitation: 10 or 14 Vdc Magnetic pickup (2-wire) Example: 0 Hz = 4 ma, 1000 Hz = 20 ma, excitation N/A The idrx-fp is a digital signal conditioner which communicates over an RS-485 communication link using either a simple straightforward ASCII Serial Protocol or MODBUS Serial Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m without repeaters. The optional EIS-2B iserver module can connect up to 32 idrx RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iserver can also be used as a simple Serial to Ethernet bridge or converter to connect a single idrn RS-232 device to an Ethernet network and the Internet. idrx-fp 168 Digital signal conditioner with RS-485 output for Frequency/Pulse inputs idrn-fp 198 Signal conditioner with analogue output for Frequency/Pulse inputs Ordering Example: idrn-fp, signal conditioner, and DB9-RJ12, connector adaptor, 168 + 20 = 188. 337 Please see page 487 for flow sensors or visit omega.co.uk Accuracy at 25 C: ±0.01% FS Resolution: 15 to 19-bit Power Consumption: 2.4 W (100 ma @ 24 Vdc) without excitation, 3 W (125 ma @ 24 Vdc) with excitation Input Ranges: Frequency from 200 Hz to 50 KHz pulse from 20,000 to 200,000,000 pulses full scale RS-485 (NEWPORT Serial Protocol idrn Output: 0 to 10 V @ 10 ma max; 0 to 20 ma or 4 to 20 ma FP Default Settings idrn: Input 0 to 20 KHz; Output 4 to 20 ma (custom settings available at no charge) TRANSMITTERS

AC Voltage/Current Signal Conditioners NEWPORT TM Software Selectable Input Ranges idrx-acv: 0 to 400 mv to 0 to 400 Vac idrx-acc: 0 to 10 ma to 0 to 5 A ac 14-Bit Resolution (max) 0.2% FS Accuracy Factory Setup and Configuration Available at No Charge (for idrn Analogue Output models) The idrn and idrx Series signal conditioners provide highly accurate, stable and isolated measurement of AC voltage and current signals across extremely wide ranges: AC Current ranges from 0 to 10 ma through 0 to 5 A ac; AC Voltage ranges from 0 to 400 mv to 0 to 400 Vac. Analogue or Digital Outputs The idrn-acv and idrn-acc accept ac voltage and ac current respectively and provide an analogue output which is proportional to the input. The idrx-acv and idrx-acc accept AC voltage and ac current respectively and transmit via RS-485 Serial Communications. The Analogue Output models can OMEGA offers many types of Current Transformers. Please visit omega.co.uk idrx-acv 181 MFO Series, 13.50 (basic unit). RCT Series, 13.50 (basic unit). Covered by U.S. and International patents and pending applications. be configured for outputs of 0 to 10 Vdc, 4 to 20 ma or 0 to 20 ma with the free configuration software. The modules connect to a PC with RS-232 Serial Communications, or by Ethernet with the optional EIS-2B module. Once configured the settings are stored in nonvolatile memory and the unit can be disconnected from the PC. Factory Setup and Configuration at No Extra Charge (idrn Analogue Output Modules) idrn-acv: Input value high and low; output value high and low Example: 0 volts = 4 ma, 400Vac = 20 ma idrn-acc: Input value high and low; output value high and low Example: 0 A = 4 ma, 5 A = 20 ma The idrx-acc (Current) and idrx-acv (Voltage) communicate via RS-485 Serial Communications using either simple ASCII Commands or the popular MODBUS Protocol. Up to 32 modules may be connected to a single RS-485 port stretching up to 1200 m, more with RS-485 repeaters. The optional EIS-2B iserver module can connect up to 32 idrx RS-485 Signal Conditioners to an Ethernet network and the Internet using standard TCP/IP protocol. The iserver can also be used as a simple Serial to Ethernet bridge or converter to connect a single idrn RS-232 device to an Ethernet network and the Internet. MOST POPULAR MODELS HIGHLIGHTED! idrx-acc 181 Digital signal conditioner with RS-485 output for AC current input idrx-acv 181 Digital signal conditioner with RS-485 output for AC voltage input idrn-acc 231 Signal conditioner with analogue output for AC current inputs idrn-acv 231 Signal conditioner with analogue output for AC voltage inputs Ordering Example: idrn-acv, signal conditioner, and DB9-RJ12, connector adaptor, 231 + 20 = 251. 338 Accuracy at 25 C: ±0.2% FS Resolution: 10 to 14-bit Power Consumption: 2.4 W; (100 ma @ 24 Vdc) MODEL idrx-acv/idrn-acv Input Ranges: 0 to 400 mv to 0 to 400 Vac full scale Interface:RS-485; RJ-12 or screw terminal connector MODEL idrx-acc/acc Input Ranges: 0 to 10 ma to 0 to 5 A ac full scale RS-485 (NEWPORT Serial Protocol idrn Output: 0 to 10 V@10 ma max; 0 to 20 ma or 4 to 20 ma ACC Default Settings idrn: Input 0 to 5 Amp; Output 4 to 20 ma (custom settings available at no charge)

NEWPORT TM Embedded Internet iseries Meters and Controllers - Direct Connection to Ethernet (Each device has own IP Address) Standard Ethernet Hub or Switch Ethernet LAN INTERNET PC on LAN PC on Internet i8 Panel Meter Embedded Internet The NEWPORT fi iseries devices can connect directly to an ethernet network with a standard RJ-45 connector and can send and receive data in standard TCP/IP packets. (Please specify EI or C4EI option.) The iseries devices can serve Web pages over an ethernet LAN or even over the Internet making it possible to monitor and control a process through a web browser (such as Microsoft Internet Explorer) from anywhere in the facility or anywhere in the world. Remote Control For example, using an iseries 1 16 DIN temperature controller to control a heater, an engineer can monitor the temperature, change set points or alarm points, turn the heater on and off, or make other modifications from anywhere on the local network, or anywhere on the Internet. The web pages are easily customised and secure password protected access to the devices is easily controlled. And it requires absolutely no special software on the engineer's computer to view the data and supervise the controller nothing other than a Web browser. Email and Alarm In fact, the iseries controller can even send an email to the engineer (or anyone they choose) alerting them to an alarm condition or updating the status. Leveraging the technology of the Internet, the engineer could receive a message from the iseries controller on an Internet enabled pager or mobile phone. Most remarkable is that all this can be accomplished without a computer. The NEWPORT TM iseries device (meter or controller) connects directly to the ethernet network not to the serial port of a computer functioning as a server and master to slave instruments connected through serial communications. The iseries devices are also available with RS232, RS422, and MODBUS serial communications (specify the C24 option). In fact, the iseries are the first instruments of this type which include all these serial protocols on one device, selectable from a menu. Internet Appliances With the EI option, these small 1 8 DIN and 1 16 DIN instruments are stand-alone Web servers. The ethernet and Web server capability is actually embedded in the device. (The smallest 1 32 DIN size device must be connected to an external iserver.) The NEWPORT TM iseries device is assigned an IP address on the network and can also be assigned an easily remembered name such Internet IP Address Web Controller as Heater1. In fact, the device could be assigned an authorised Internet IP address from an Internet service provider and function as a World Wide Web server delivering whatever specific information is called for. (For an example, please see www.omega.co.uk/iserver) The iseries devices work well with conventional industrial automation, data acquisition and control programs as well as Microsoft Visual Basic and Excel. NEWPORT TM provides free software and demos which makes it fast and easy to get up and running with many applications. Rear Terminal Connections 151 1 16 DIN Controller 314

Using iserver as HUB/Server for up to 32 Devices Standard Ethernet Hub or Switch Using NEWPORT TM 1 8 DIN iseries controller with C4EI option as HUB for up to 32 Devices Standard Ethernet Hub or Switch Conventional Serial Communication connections using PC with RS-485 Serial Communication Standard Ethernet Hub or Switch i 32 Controller iserver i 32 Controller i 32 Controller i8 Panel Meter i8 Panel Meter with C4EI Option i8 Panel Meter Get Internet E-mail Notification of Alarm Status on Your Web-Enabled Phone or PDA. The iserver is a DIN rail device which can be a hub connecting up to 32 instruments to the Ethernet and Internet. The iserver is both a Web Server and an Ethernet-Serial bridge. To connect to the iserver, iseries devices must feature the C24 Serial Communications option. The NEWPORT TM iserver is also compatible with the NEWPORT INFINITY family of ultra high performance digital panel meters and the NEWPORT TM idrx family of signal conditioners. The iserver can also connect almost any RS232 or serial device to Ethernet. EIS-2B 131 315 A Web Server and an Ethernet Bridge Serves up to 32 Devices The iserver is an alternate way to connect iseries devices to an Ethernet LAN or Internet. Instead of connecting each iseries device directly to the Ethernet network, with individual IP addresses for each device, the iserver can be a HUB/server for up to 32 devices. Model No. Description Price EIS-2B iserver industrial MicroServer, 131* serves 32 devices Options idrn-ps-1000 Power supply (switching), 101 95 to 240 Vac input, 24 Vdc output @ 1 A (powers 10 units) CONTROLLERS

Freephone 0800 488 488 International +44(0) 161 777 6622 Fax +44(0) 161 777 6622 Sales@omega.co.uk www.omega.co.uk UNITED KINGDOM www. omega.co.uk Manchester, England 0800-488-488 UNITED STATES www.omega.com 1-800-TC-OMEGA Stamford, CT. CANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA GERMANY www.omega.de Deckenpfronn, Germany 0800-8266342 FRANCE www.omega.fr 088-466-342 CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic 596-311-899 BENELUX www.omega.nl 0800-099-33-44 More than 100,000 Products Available! Temperature Calibrators, Connectors, General Test and Measurement Instruments, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders, Relative Humidity Measurement Instruments, PT100 Probes, PT100 Elements, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies, Thermocouples, Thermowells and Head and Well Assemblies, Transmitters, Thermocouple Wire, RTD Probes Flow and Level Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves,Variable Area Flowmeters, Vortex Shedding Flowmeters ph and Conductivity Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, ph Electrodes and Instruments, Water and Soil Analysis Instrumentation Data Acquisition Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers Pressure, Strain and Force Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Pressure Transmitters, Strain Gauges, Torque Transducers, Valves Heaters Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters