Series 8000 RF Signal Switch Solution

Similar documents
Series 8000 RF Signal Switch Solution

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

Model Channel TTL I/O

Model SPDT Switch Module

Model SPDT Mercury Wetted Relays

Model 7026 (1x32) 2-wire Multiplexer

Model , 32C, 32S, 32i/opt 1, opt 5 4(1x8) & 8(1x4) & 8(1x2) Coaxial Multiplexer

Model DPDT Switch Module

Model SPDT 5A Relays

Model Peripheral Driver, Multi-Channel &

Programming Guide. for Giga-tronics ASCOR 3000 Series Switching Modules

EMSwitch RF Switch Plug-In Card

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

±15 V Current-Limited Power Supply

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Agilent 70612B K18 Switch Matrix

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Tempco Instruction Manual

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

iconverter 2-Module Power Chassis

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LCI User Manual mantracourt.com

UTAH-100/XHDA SERIES

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

CPS Industrial Power Supply

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

KBMG MULTI-SPEED BOARD

Line Impedance Stabilization Network (LISN)

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

Model 7705 Control Module

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

Automated Tuner System Power Distribution Hub

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

87421/22A Power Supply. Operating and Service Manual

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

MAXIMA+ Series Rotary Level Indicator

Power Supply (48Vdc, 2.5A)

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

Metro-Optical Transport Access Nodes

MAXIMA + Series ROTARY LEVEL CONTROL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

LCI Load Cell Junction Box with Fault Monitor

Model VT120 Fast Timing Preamplifier Operating and Service Manual

CPCI - 6U - AC - 600W

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

300 WATT GUITAR POWER AMPLIFIER. Instruction Manual

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

EOS-6000 Series Optical A/B Switch User Manual DC Version

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

Power Meter PowerMonitor 500

Operating Instructions. For. Level Control Module. Model SSR 1000

T1/E1 Channelized Gigabit Router

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Miniature Overhead Stirrer

MODEL 805 USER MANUAL

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Features. SC Switch Control Platforn. SC2000, SCX2000, SCP2000 SCM Series Modules

Safety Standards. Model Number:

PRODUCT SPECIFICATION. PC Board Relays. Series.

Installation, Operation & Maintenance Instructions / Technical Document

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL

VIP-812A DUAL NETWORKED STATION PORT

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Data Sheet VI-IAM, VE-IAM. Input Attenuator Modules. VI-IAM Specifications (Typical at TBP = 25 C, nominal line, 75% load, unless otherwise specified)

Model Number Structure

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

5401 and 5402 Digital I/O Modules

CompactLogix Power Supplies Specifications

to 48V DC Power Supply

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su

User s Guide. 600A AC Clamp Meter. Model 38387

American Power Design, Inc.

PWRguard PLUS Spring City Drive Waukesha, WI

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

MTS-2000 USER S MANUAL

General Operating, Maintenance and Installation Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Safety Standards. Model Number: Unit Weight:

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Transcription:

RF Signal Switch Solution Operation Manual Operation Manual, Part Number 07508000-006, Rev. A, May 17, 2013

All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics, Incorporated. 2013 Giga-tronics Incorporated. All rights reserved. Printed in the U.S.A. Warranty Giga-tronics Series 8000 instruments are warranted against defective materials and workmanship for one year from date of shipment, or as detailed in the warranty section of this manual. Giga-tronics will, at its option, repair or replace products that are proven defective during the warranty period. This warranty DOES NOT cover damage resulting from improper use, nor workmanship other than Giga-tronics service. There is no implied warranty of fitness for a particular purpose, nor is Giga-tronics liable for any consequential damages. Specification and price change privileges are reserved by Giga-tronics. MODEL NUMBERS The Series 8000 includes many models. Apart from the number of switches they support, the models are identical. The models are referred to in this manual by the general term Series 8000, except where it is necessary to make a distinction. CONTACT INFORMATION Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800.726.4442 (only within the United States) +1 925.328.4650 (international) Fax: 925.328.4700 Email: inquiries@gigatronics.com Website: www.gigatronics.com Operation Manual, Part Number 07508000-006, Rev. A, May 16, 2013 Page 2

Regulatory compliance information This product complies with the essential requirements of the following applicable European Directives, and carries the CE mark accordingly. 89/336/EEC and 73/23/EEC EN61010-1 (1993) EN61326-1 (1997) EMC Directive and Low Voltage Directive Electrical Safety EMC Emissions and Immunity Manufacturer s Name: Giga-tronics, Incorporated Manufacturer s Address 4650 Norris Canyon Road San Ramon, California 94583 U.S.A. Type of Equipment: DC to 40 GHz RF Switch 8000 Model Series Number Model Numbers: 8000 Declaration of Conformity on file. Contact Giga-tronics at the following; Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800.726.4442 (only within the United States) 925.328.4650 Fax: 925.328.4700 Operation Manual, Part Number 07508000-006, Rev. A, May 16, 2013 Page 3

Record of Changes to This Manual Use the table below to maintain a permanent record of changes to this document. Corrected replacement pages are issued as Technical Publication Change Instructions (TCPI). When you are issued a TCPI, do the following: 1. Insert the TCPI at the front of the manual binder. 2. Remove the pages from the manual binder that are noted in the TCPI. 3. Replace the page(s) removed in the previous step with the corrected page(s). 4. Record the changes in the table below. TPCI Number TPCI Issue Date Date Entered Comments Operation Manual, Part Number 07508000-006, Rev. A, May 16, 2013 Page 4

Record of Changes Revision Description of Change Chg Order # Approved By A Initial Release 3565 G.G. Operation Manual, Part Number 07508000-006, Rev. A, May 16, 2013 Page 5

Table of Contents SECTION 1... 7 SAFETY AND MANUAL CONVENTIONS... 7 OVERVIEW... 8 FUNCTIONAL DESCRIPTION... 8 WARRANTY... 8 FRONT/REAR VIEW... 9 SECTION 2... 10 UNIT DEFAULTS... 10 CONTROL COMMANDS... 10 SWITCH CLOSURE, COUNTER, QUERY COMMANDS... 11 SECTION 3... 12 AC INPUT MODULE FUSE... 12 52000100-024 - FUSE, 250V, TYPE T, SLO-BLO, 6.3 AMP... 12 POWER SUPPLY SPECIFICATIONS... 12 47500680 Universal Power Supply, 250W, 5V/30A & 12V/16.7A, W/FAN... 12 SECTION 4... 13 RF SWITCH SPECIFICATIONS... 13 See your manual addendum for switch specifications.... 13 SECTION 5... 14 OUTLINE DRAWINGS... 14 Series 8000 OUTLINE DRAWING... 14 RF SWITCH FACE DETAIL... 15 Operation Manual, Part Number 07508000-006, Rev. A, May 16, 2013 Page 6

LAN SAFETY AND MANUAL CONVENTIONS SECTION 1 This manual contains conventions regarding safety and equipment usage as described below. Product Reference Throughout this manual, the term Series 8000 refers to all models of within the series, unless otherwise specified. Personal Safety Alert! WARNING WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Equipment Safety Alert CAUTION CAUTION: Indicates a situation which can damage or adversely affect the product or associated equipment. Notes Notes are denoted and used as follows: NOTE: Highlights or amplifies an essential operating or maintenance procedure, practice, condition or statement. Electrical Safety Precautions Any servicing instructions are for use by service-trained personnel only. To avoid personal injury, do not perform any service unless you are qualified to do so. For continued protections against fire hazard, replace the AC line fuse only with a fuse of the same current rating and type. Do not use repaired fuses or short circuited fuse holders. Operation Manual, Part Number 07508000-006, Rev. B, Nov. 15, 2010 Page 7

OVERVIEW This manual describes a version of the Series 8000 products. They are full-rack wide units with terminated RF Switches that are controlled by an Ethernet or GPIB Interface. The Series 8000 line of switch products are based on rugged electromechanical switches and microwave relays rated for use from DC to 40 GHz, with low insertion loss and high isolation. Route signals under remote control to simplify and improve automated test systems. Easily removable switches allow reduced mean time to repair. The Series 8000 is a self-contained design, with built-in power supplies, microprocessor-based controller board and up to 256 relay coils, making it easy to implement a microwave switch system. It is designed to host many combinations of microwave relay switches, terminated or non-terminated: SPDT, SP4T, SP6T, SP8T, or Transfer switches. With a standard SCPI command set, the control interface provides the Series 8000 with ease of operation and configurability. FUNCTIONAL DESCRIPTION The design is housed in a 3 RU (5.25 inch) high, full rack size unit. The unit fits in a standard 19 inch rack cabinet and is provided with mounting flanges to enable it to be mounted in the rack. The unit is self contained, that is, it contains its own power supplies, communications interface, RF relay driver circuits and the RF relays mounted on the front. The RF Switches can be removed from the front of the unit. The Ethernet interface is an IEEE-488.2 device and uses standard Control commands to control its digital interface. (See Section 2 for the Control Command Set for this instrument.) A single power supply provides +5 VDC and +12 VDC to the unit. The power supply input is 90-250 VAC, 47-63 Hz. (See Section 3 for full specifications) The RF switches are 50 Ohm impedance, with a frequency range capability of DC to 40 GHz. (See Section 4 for full specifications) WARRANTY Product is warranted to conform to all applicable specifications for a period of one (1) year from acceptance, or the relay cycle life, whichever comes first. Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 8

FRONT/REAR VIEW The figures below illustrate the front and rear power, power indicator and switch positions for the units. Switch configuration and rear panel as shown are for reference only. Figure 1 Series 8000 Front panel view Figure 2 Series 8000 Rear panel view, LAN Figure 3 Series 8000 Rear panel view, GPIB Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 9

SECTION 2 UNIT DEFAULTS This unit is shipped from the factory with the following default settings: Default IP Address (LAN units only): 192.168.5.254 Default Timeout: 1,000 seconds Default GPIB Address(GPIB units only): 4 CONTROL COMMANDS An example of control commands is shown below. For your specific configuration, reference the addendum for your switch product. LOCATION SW POSITIONS CONNECTS TO SCPI COMMANDS S1 1 Open J3 (on Relay Control ROUTe:SWITch 1, 0 1 board) ROUTe:SWITch 1, 1 2 ROUTe:SWITch 1, 2 3 ROUTe:SWITch 1, 3 4 ROUTe:SWITch 1, 4 5 ROUTe:SWITch 1, 5 6 ROUTe:SWITch 1, 6 LOCATION SW POSITIONS CONNECTS TO SCPI COMMANDS S6 6 Open J8 (on Relay Control ROUTe:SWITch 6, 0 1 board) ROUTe:SWITch 6, 1 2 ROUTe:SWITch 6, 2 3 ROUTe:SWITch 6, 3 4 ROUTe:SWITch 6, 4 5 ROUTe:SWITch 6, 5 6 ROUTe:SWITch 6, 6 NOTE: The commands referred to in this manual assume that the switches are connected properly to the relay control board connectors. If the switches are physically moved to a different location in the front panel, the command parameters DO NOT change. If such a physical change is made, the user assumes the responsibility of properly identifying the switch locations. CAUTION Please consult Giga-tronics factory before making any changes in your equipment! Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 10

SWITCH CLOSURE, COUNTER, QUERY COMMANDS The SCPI commands required to set switch positions, query the switch count, and to save counters are listed below with an example switch configuration. These end user commands are always accessible. ROUTe:SWITch Sw, P Sets a switch to a desired position. Sw is the switch identification number, 1-6. P is the desired position as a decimal value. Sw Positions 1 0, 1, 2, 3, 4, 5, 6 6 0, 1, 2, 3, 4, 5, 6 NOTE: 0 = Open, or No Connection ROUTe:SWITch? Sw Returns switch position, current switch count, and switch identifier string. Sw is a number to identify the switch. The response is: Sw, position, count, ID. An example is: ROUTe:SWITch? 2 2, 5, 1002123, S/N 12345678 ROUTe:SWITch:SAVe ROUTe:SWITch:SAVe? Saves all switch counter values to flash memory. The command only saves the current counter values. Queries the number of flash saves done via the ROUTe:SWITch:SAVe command, power fail and auto save intervals. Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 11

SECTION 3 The unit is equipped with a replaceable fuse on the AC power input module AC INPUT MODULE FUSE 52000100-024 - FUSE, 250V, TYPE T, SLO-BLO, 6.3 AMP POWER SUPPLY SPECIFICATIONS 47500680 Universal Power Supply, 250W, 5V/30A & 12V/16.7A, W/FAN INPUT Parameter Conditions /Description Min Nom Max Units Input Frequency 47 63 Hz Input Voltage 90 132 / 180 264 Auto-selectable 90 264 VAC Input Current At 100 120 VAC At 200 240 VAC 8 4 A A Inrush Current Peak measured at 230 VAC at full load, cold start Peak measured at 115 VAC at full load, cold start 35 70 A A Power Factor Passive power factor correction meets EN61000-3-2 class A OUTPUT Parameter Conditions /Description Min Nom Max Units Transient Response Output voltage returns to within 1 % in less than 2.5 ms 2.5 ms for a 50 % load change. Peak transient does not exceed 5 % Overshoot Turn-on and turn-off overshoot shall not exceed 5 % 5% over nominal voltage Efficiency Measured at 230 VAC and full load 75 % Turn on Delay At 120 VAC 1 second Hold up Time At 120 VAC and 80 % of rated maximum load 20 ms PROTECTION CIRCUIT Parameter Conditions /Description Overload Current limiting starts at 110 140 % of the rated output current in foldback mode and recovers automatically Short Circuit Output Over-voltage Over Temperature Short circuit can be continuous. Recovers automatically upon removal of shout Output is protected against over-voltage. Unit shuts down and latches when the voltage at output terminals exceeds 130 %. AC needs to be reset to restart the power supply Power Supply shuts down when temperature is in excess of 85 C. Auto Recovery Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 12

SECTION 4 RF SWITCH SPECIFICATIONS See your manual addendum for switch specifications. Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 13

SECTION 5 OUTLINE DRAWINGS Series 8000 OUTLINE DRAWING Note: Switch configuration as shown may different from your model Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 14

RF SWITCH FACE DETAIL 2.25 x 2.25 SP6T switch shown is typical, for reference only. All coax connector shall be tightened to the torque specified below. Connector Type Material Torque Value American Metric SMA, SMA 2.9 Stainless Steel 7 10 in-lbs. 0.79 1.13 N-m Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 15

Notes Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 16

Operation Manual, Part Number 07508000-006, Rev. A, June 26, 2013 Page 17