Computertechnik GmbH Serial Module RS232C Standard Technical Description Order number: 404.249010.000 6 ISA96 Serial Module RS323C standard Your contact: 2001 by Janich & Klass Computertechnik GmbH, Wuppertal 24.09.01 Zum Alten Zollhaus 20 42281 Wuppertal Germany Tel.: +49 (0)202 2708-0 Fax.: +49 (0)202 700625 www.janichklass.com
Table of Contents 1. General Features...5 2. Schematics Description...5 3. Installation...5 4. Plug Assignment...6 5. Technical Data...6 5.1. Environment Conditions...6 Page 2 (24.09.2001)
Copyright 2001 Janich & Klass Computertechnik GmbH. All rights reserved. Printed in Germany. The information contained in this documentation is the property of Janich & Klass Computertechnik GmbH, Wuppertal. Neither receipt nor possession hereof confers or transfers any right to reproduce or disclose any part of the contents hereof, without the prior written consent of Janich & Klass. Trademarks All product names and logos are trademarks or registered trademarks of their representative companies. Disclaimer The contents of this manual are checked for matching the described product. Deviations cannot be excluded, so that we cannot give any guarantee for full accuracy. The details of this manual are however regularly checked. Necessary corrections will be contained in the subsequent revisions. We will be thankful for any improvement proposals. Janich & Klass Computertechnik GmbH assume no liability for damages incurred directly or indirectly from errors in this manual, omissions, or discrepancies between this manual and the product. Safety Hints This unit may not be used in any other way than described in this manual. Installation, putting into operation, and maintenance of this unit may exclusively be made by qualified personnel. This personnel must be familiar with the warnings and hints of this manual. Qualified personnel by means of this manual are persons who are familiar with installation, mounting, putting into operation and operation of this unit and who have the qualification fitting their tasks, like for example: - Education and instructions, respectively the authorization to switch on/off, to ground, and to tag current circuits and units resp. systems as per the actual standards of safety technique. - Education and instruction as per the actual standards of safety technique concerning maintenance and use of appropriate safety equipment. - Education in First Aid. Before you put this unit into a bus-rack, you have to check whether the required voltages are available at the specific connector pins, and whether the required currents can be fed. Before exchanging any units, the sub-rack must be switched off. This unit contains electro-statically endangered components. Electro-static discharge through the human body or similar must therefore by all means be avoided, for example, by prior touch to grounded metal parts (water pipe, etc.). This is important specially before exchanging the unit. You have to retighten all locking screws after every exchange. Protect this unit from moisture. By no means conductive matters or liquids may enter the unit. Do not operate the unit at higher temperatures than stated in this description. Connected wires may not be subject to tension load. (24.09.2001) Page 3
Do not expose the unit to strong magnet fields, for the danger of data loss from the hard disk. The unit may not be exposed to strong vibrations, as they might destroy the hard disk. In case of a defective fuse, please by all means replace it with a new one of the same type, as otherwise fire danger exists. At visible damages of the unit, please return it to Janich & Klass for repair. (Each unauthorized repair may lead to loss of the guarantee.) Do not try to repair this unit on your own. Please always address yourself to Janich & Klass in case of eventual repair. Guaranty repair must always be made directly by Janich & Klass. History Revision Date Name Modifications HW-Revision 2.0 13.07.2001 p.b adopted to Hardware Rev. 2.0 2.0 Page 4 (24.09.2001)
1. General Features On some of the boards of the ISA96 board family, the principle of exchangeable driver modules has been realized. The Serial Module RS232C is a driver card for the serial interfaces in this board family. It contains the necessary components, as well as a 9pin Dsub- Connector, to build up an AT-compatible serial interface. The Topics in Short: Serial Module for the ISA96 family three drivers and five receivers to CCITT V.28 signals Rx, Tx, CTS, RTS, DSR, DTR, DCD and RI according to CCITT V.24 9pin Dsub-Connector with AT-compatible pin assignment supply voltages +5V, +12V and -12V power consumption: 30mA (+5V), 140µA (+12V), 340µA (-12V) without load 2. Schematics Description The controller components for the serial interfaces are located on the motherboards of the ISA96 board family. The input and output signals of these components are transmitted to the Serial Driver Module via 16pin connectors on TTL-level. The Serial Module RS232C transforms the TTL level to the desired CCITT V.28 levels. For this purpose, the card has the driver component IC1 with three drivers and five receivers as per CCITT V.28. An ample passive filter technique secures an EMC-friendly behavior of the card. 3. Installation After the computer is switched off, remove the card to be retrofitted from the sub-rack. If other modules are installed on the card which might hinder the installation, please remove them. Remove the two screw bolts of the DSUB connector from the Module to be inserted. Now, the Module is inserted from he rear side of the front panel (with its assembled side pointing downwards!) in a way that the DSUB connector exactly fits into the foreseen section in the front panel. Finally fasten the DSUB connector with the screw bolts at the front panel. (24.09.2001) Page 5
4. Pin Assignment S2 9pin D-Connector (107) DSR 6 1 DCD (109) (105) RTS 7 2 /RxD (104) (106) CTS 8 3 /TxD (103) (125) RI 9 4 DTR (108) 5 Ground (102) The indications in brackets are the short signal denominations as per CCITT V.24. 5. Technical Data Size: Weight: Design: Installation position: Cooling: Power consumption: 33mm * 84mm * 14mm 36g 4-layer board FR4 with solder mask. All plugs are gold-covered. is pregiven by the ISA96 card. at upright installation convection cooling with at least 1m/min air speed. 30mA (+5V), 140µA (+12V), 340µA (-12V) without load 5.1. Environment Conditions Supply voltages: 4,75V - 5,25V (+5V) 4,5V - 13,2V (+12V) -4,5V - -13,2V (-12V) Operating temperature: Storage temperature: Relative humidity: Storage period: 0-70 C. -40-85 C. 10-90% non-condensing. unlimited Page 6 (24.09.2001)