Suction Pressure Sensor

Similar documents
Differential Pressure Sensor

Pressure Transducer Model PR-264

Low Pressure Transducer Model PR-274/275

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

TPE 1464 Series Pressure Transducer

High Temperature Data Logger

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

M5100 Heavy Industrial Pressure Transducer

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

SP6R Level Controller Operation Manual

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

87421/22A Power Supply. Operating and Service Manual

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

ES-600 Ozone Controller Operation Manual

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

LCI User Manual mantracourt.com

MicroLink Installation Operation & Specifications Manual. General Description

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

OZONE SWITCH Model OS-6. OS-6 Features

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

M7100 Pressure Transducer

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Model Number Structure

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

Xxxxx Xxxxxx DC Voltage Data Logger

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

Automated Tuner System Power Distribution Hub

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Conductive Level Controller

P027 Series Pressure Transducer Installation & Operation Manual

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Miniature Overhead Stirrer

U7100 Pressure Transducer

Installation Operation & Specifications Manual. General Description

S82S (3/7.5-W Models)

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Photoelectric Sensor

Solid State Relays with Failure Detection Function

Photoelectric Sensor

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

MODEL 245 / 345 High Range

LCI Load Cell Junction Box with Fault Monitor

MTS-2000 USER S MANUAL

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

HIGH ACCURACY PRESSURE TRANSDUCERS

User's Guide. Phase Sequence and Motor Rotation Tester Model

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

User Guide. Control Box. RoscoLED TM.

American Power Design, Inc.

Differential Liquid/Gas Pressure Transmitter

Model Number Structure

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Low Pressure Digital & Analog Sensor

User's Guide. Extech AM A AC Analog Clamp Meter

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Model SST Slimline Submersible Pressure Transmitter

CA-A480-A Elevator Controller. Reference & Installation Manual

Proliphix EPA-60 Installation Guide

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

DC425 NEMA 4X Analog Output Transducers

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

User s Guide. POWERVAR Single Phase Power Conditioners

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Number of input channels

Mini Digital Multimeter

esense Duct (-Disp) Conduit

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

SERVICE MANUAL MODEL SSP-350-X

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

USB 3.0 Spectra

Transcription:

Suction Pressure Sensor Model PR-265 RoHS 100% solid state fused silicon pressure sensor Rugged, leak-proof 316L stainless steel mono-..lithic pressure cavity with no welds, O-rings, or..seams/bonds Up to 300% overpressure without zero shift Over 500% burst pressure Wide 12-40 VDC/12-35 VAC unregulated..supply..voltage Two temperature compensated output versions,..4-20 ma 2-wire or field selectable 0-5 VDC/0-10..VDC NIST traceable calibration Rugged NEMA 4 (IP-65) enclosure with external mounting bracket Conforms to EMC and RoHS standards The PR-265 incorporates sophisticated integrated circuits and a new fused silicon monolithic cavity pressure sensor to provide a high level, fullyconditioned and temperature compensated output. The 316L stainless steel monolithic pressure cavity not only provides media compatibility for most of the applications, but also offers a leak proof solution for today s environment conscious customers. Two industry standard output versions are available, 4-20mA 2-wire loop or field selectable 0-5 VDC/0-10 VDC. Wide 12-40 VDC or 12-35 VAC unregulated supply voltage and a broad 0ºF-180ºF compensated temperature range ensures compatibility to most of the applications. Rugged NEMA 4 (IP-65) enclosure, gasketed cover, external mounting bracket, fully temperature compensated NIST traceable accuracy and a liberal five year warranty are some of the features which make the PR-265 the industry s most reliable, rugged, and economical pressure sensor. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

The PR-265 sensing element is a 100% solid state silicon strain fused directly onto the 316L stainless steel monolithic pressure cavity. The pressure cavity is machined out of a solid rod and does not incorporate any welds, seams, or bonds. In this way, the sensor not only offers excellent linearity, repeatability and sensitivity, but also exhibits negligible hysteresis and withstands significant overpressure without zero shift. The monolithic nature of the cavity ensure not only leak proof operation but also enhances the overpressure and burst pressure specifications. The pressure cavity design incorporates novel techniques to isolate the fused silicon sensing element from installation related stress thereby ensuring zero integrity. The 316L stainless steel offers excellent media compatibility to most of the industrial and commercial applications. The PR-265 incorporates sophisticated integrated circuits to provide a high level, fully conditioned and temperature compensated output. On VDC output units, two additional field selectable options are available: dual outputs 0-5 or 0-10 VDC, and dual unregulated supply voltages 12-35 VAC or 12-40 VDC. By merely changing a dip switch, one can select the desired output for the specific application. As far as supply voltage is concerned, the unit automatically configures for AC or DC and no field selection is necessary. Another feature is that the output is fully protected from short circuit to ground, or if the supply voltage is applied by mistake to the output. Past experience demonstrates that field related wiring problems do occur. Instead of denying this fact, the protections circuit is designed in to ensure trouble-free start-up. The VDC output unit is also designed to handle low impedance circuits. In fact, the unit can drive up to 1K ohms minimum. In this way, multiple controllers, indicators or other devices can be paralleled to the output without performance degradation. The ma output units can function over a wide unregulated supply voltage range: 12-40 VDC without any effect on calibration or performance. The unit has reverse polarity protection built in. As a result, it is next to impossible to damage the unit by mis-wiring. By using sophisticated low drop-out voltage regulators and CMOS integrated circuits, the ma output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 400 ohms. At 40 VDC, the unit is capable of handling up to 3000 ohms load. In this way, the output loop can be tied in series to multiple controllers, indicators, and other devices without degrading the performance. Automated NIST traceable pressure controllers are precision pressure sensors are utilized to calibrate and certify the PR-265. Calibration data on each unit is archived digitally for SPC and QC purposes. All automated calibration systems are networked and data is available on-line to numerous individuals at the same time. In this way, extremely high standards of quality and calibration integrity are maintained. Each unit is individually temperature compensated in an environmental chamber. The temperature compensation data is also digitized and archived for future reference purposes. Compensating each unit individually ensures that published specifications are adhered to. The PR-265 incorporates a rugged NEMA 4 (IP-65) fully gasketed, dust proof and splash proof enclosure. The enclosure has an external mounting bracket to facilitate field installation. A 1/2 (.875 /22.25mm dia.) knock-out for conduit connection is also provided. A liquid tight cable connector is also supplied if the unit is not being hard wired. Once installed, the enclosure maintains its environmental rating and protects the electronics and the sensing element from condensation, corrosive contaminants and other environmental pollutants. The unit also has additional features for ease of installation including unpluggable terminal block, easily accessible zero and span trimmers, and conveniently located dip switches for field selection. 2

SPECIFICATIONS: Accuracy*: ± 1% FS Overpressure: 300% Burst Pressure: 500% Supply Voltage: 12-40 VDC 12-35 VAC (VDC output units only) Supply Current: VDC Units 10 ma max. ma Units 20 ma max. Load Impedance : 3K ohms max. at 40 VDC (ma output units) 1K ohms min. (VDC output units) Enclosure: 18 Ga C. R. Steel NEMA- 4 (IP-65) Finish: Baked on enamel-pms2gr88b *Includes non-linearity, hysteresis and non-repeatability. U.S. PATENT NO. 6484587 Compensated Temp Range: 0ºF 180ºF (-18ºC 82ºC) T. C. Error: ±0.025%/ºF (.03%/ºC) Media Compatibility: Liquid/gases compatible to Port Connection: 1/8 NPT 316L stainless steel Environmental: 10 90%RH Non-Condensing Termination: Unpluggable screw terminal block Wire Size: 12 Ga max. Weight: 1.0 lbs. (.45 kg) CONFORMANCE & TESTING: RoHS Compliant EMC Testing: BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 ORDERING INFORMATION: PR-265- Range Output R1 0 to 30 Inch Hg ma (4-20 ma 2-wire) R2 +/-15 psig VDC (0-5 VDC or 0-10 VDC field selectable) Example: PR-265-R1-mA: With R1 Range which has 0 to 30 inch Hg and 4-20 ma output. CAUTION: Do not use in explosive/hazardous environment or with flammable/combustible media. 3

3.00" (76.21) 3.00" (76.21) 4.00" (101.60) 2.658" (67.51) 3.25" (82.55) 6.00" (152.40) 2.25" (57.15) 5.00" (127.00) (mm) 4

MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876