INNOMETRIKS INC. Rhino Quick Start Guide

Similar documents
INNOMETRIKS INC. Rhino Implementation Guide

Secure Solutions. EntryPointTM Access Readers TrustPointTM Access Readers EntryPointTM Single-Door System PIV-I Compatible Cards Accessories

Details on reader configuration, administration and general functionality are contained in the Cheetah SE Reader User Guide.

UC-2000 Installation Manual Unicorn Computers Technology Limited

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Quick Start Installation Guide

IEI emerge MicroNode Install and Setup Guide. Contents

FACIAL RECOGNITION TERMINAL SYSTEM

BioPointe Reader Installation Guide

MRDT Display Terminal

Quick Start Installation Guide

PXL-250 Tiger Controller

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Quick Start Installation Guide

EL-ST100 KEYPAD CONTROLLER

CM-110SK Standalone Keypad Installation Instructions

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

Securing Federal Government Facilities A Primer on the Why, What and How of PIV Systems and PACS

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

g6 Authentication Platform

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

Waterproof. Keypad/Reader/Controller

Innometriks Cheetah SE Reader User Guide

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Click Save to return to the main Setup screen.

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

6222 Two Door Module Technical Operations Manual

The SilverNugget is a servo controller/driver for NEMA 34 frame microstep motors.

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

eh880 Secure Smart Card Terminal

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

Strategies for the Implementation of PIV I Secure Identity Credentials

Pyramid Series Proximity Readers

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

DESIGN GUIDE FOR INFINITY SYSTEMS

MR52 READER INTERFACE

CardaxFT Reader I/O Interface

AuxBox Activation hub for integrating remote dry-contact closure triggering devices

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

SmartLock Controller INSTALLATION MANUAL

INSTALLATION GUIDE Xpass English Version 2.00 EN XPS V2.00A

Connecting a Cisco Output Module

Connecting a Cisco Reader Module

Integrity Instruments

V-Series V30x Module Electrical, Physical Layer, and Application Integration. Customer Information Brief Version 1.4

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

VICON ACCESS CONTROL CONTROLLERS

MR51e Reader Interface

GV-EL124S Electric Strike

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

DOLXFD1000B. Waterproof Access Control/Reader

Cat5 5500HD EXT-CAT5-5500HD USER MANUAL.

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

INSTALLATION GUIDE Xpass S2 English Version 2.2 EN XPS2 V2.20A

Identiv FICAM Readers

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

_ Access control SISTEMAS DE SEGURIDAD

ED-22 Analog Output Series Magnetic Encoder

GV-AS Controller. Installation Guide

Connecting a Cisco Input Module

TruPortal Dual Door Interface Module Quick Reference

TWIC / CAC Wiegand 58 bit format

Veridt Reader Terminal Installation Guide Compliance Statements

Suprex RS-485 SPX-7500 Wired Reader-Extender

Akcess BioMetrics Corporation. Bio2Touch. Access Control Fingerprint Reader. User's Manual. Akcess BioMetrics Corporation

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001

MS-3000 MicroStar Reader

Integration Note OVERVIEW AND SUPPORTED FEATURES. Minimum Core Module Version: Document Revision Date: 09/25/2017

CAT5 1500HD EXT-CAT5-1500HD USER MANUAL.

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

WIEG-EXT Wiegand to RS485 extender module.

Multiple Credential formats & PACS Lars R. Suneborn, Director - Government Program, HIRSCH Electronics Corporation

VIDI-AC-2CS Access Controller/ Reader

Security Expert Smartcard Reader Mini

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

232iLM Keypad Installation and Programming Instructions

KP2000E/EM Series Style Keypad

Product Reference Guide

Installation Instructions RF5010 and RF5210

Corporate Commitment to Excellence

IRRIGANDER 4 SPLITTER SWITCH

SPX-7400_SPX-7410_MAN_161028

Quick Start Installation Guide

Brivo ACS300 (A/E/S) Installation Manual. Rev 1

Product Guide. Access Control. Composite All-In-One Cable, Reader Cables, and Accessory Cables.

Avtec, Inc. Lighting Systems

istar Pro Installation Guide

Multi Card Technology

Operation manual For NG BIOSINGLE Version 1.1

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

SmartLock Pro INSTALLATION MANUAL

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

2000 Series e/em Style Keypad Installation and Programming Manual

Surge Protective Devices. STV100K Series. Instruction Manual

Transcription:

INNOMETRIKS INC Rhino Quick Start Guide

Rhino Quick Start Guide Innometriks Inc Fallbrook, Ca. 92028 Phone 760-207-6908 Sales: Sales@innometriksinc.com General Information: Info@innometriksinc.com Customer Support: Support@innometriksinc.com Copyright Copyright 2009 by Innometriks Inc. All rights reserved. Trademarks The Rhino is a trademark of Innometriks Inc. All other product names used are trademarks of their respective owners. Notice The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Innometriks Inc. assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. Innometriks reserves the right to make changes in the product design without reservation and without notification to its users

Background Strong Identity Authentication Innometriks develops and manufactures a suite of hardware and software products that provide strong identity authentication for mission critical environments. Strong identity authentication verifies an individual s identity using technologies including biometrics, smartcards, Public Key Infrastructure (PKI) and digital signatures to provide a level of assurance above and beyond that available through simple PIN, password or non-smartcard ID card mechanisms. Strong identity authentication provides greater protection of critical assets and sensitive information. The Company s strong identity authentication offerings fill critical compliance gaps that exist in current generation physical access control systems (PACS). Although fully functional and well within their operational life span, most installed PACS fail to meet the credential verification and identity authentication requirements set forth by the U.S. Government identity programs known as Personal Identity Verification (PIV) and Transportation Workers Identity Credential (TWIC). Innometriks product offerings also fill important roles in commercial facility security, time and attendance and other applications where positive identity of individuals is of paramount importance. What Makes Innometriks Different Innometriks Products complement, not compete against, existing physical access control solutions. Innometriks offerings fill critical compliance gaps that exist in current generation physical access control systems. This strategy allows for existing vendors, who have a large installed base of non-compliant physical access control systems, to become compliant by merely replacing their non-compliant readers with Innometriks devices. The Rhino The Rhino is implemented on an open source software platform, embedded Linux, providing unprecedented flexibility in integrator and end user customization. The Rhino offers flexible configuration options for fingerprint sensors, environmental implementation (waterproof housing & enclosure heaters) and system connectivity (Ethernet, RS485, and industry standard Wiegand interfaces). Further, the Rhino line features bright, easy to read color displays and multifunction keypad to deliver an optimal user experience. Each Rhino configuration is packaged in an extremely durable metal housing engineered for application in harsh operating environment, indoors and out. Power Requirements The Rhino reader requires nominally 12VDC at 750 milliamps to operate correctly. The Rhino installed with the heater option for extreme outdoor conditions requires nominally 12VDC at 3amps to operate correctly. The wiring to deliver power to the reader should conform to proper electrical installation 1

practices and codes, and should be of a gauge required to deliver the required voltage and current to the reader without excessive loss or heating. Power Cabling Innometriks recommends power cabling of no less than 18 gauge be used for installation of standard (no heater) Rhino devices. The table below provides some guidance for standard stranded cabling with respect to distance, gauge and current (at 12VDC) and can be used to select the proper cable for powering the units. Total Branch Current in ma Wire Gauge 250 500 1000 1500 2000 2500 3000 3500 12 3023 1511 756 504 378 302 252 216 14 1901 950 475 317 238 190 158 136 16 1194 597 299 199 149 119 100 85 18 751 376 188 125 94 75 63 54 Maximum distance in feet Reader Communication Communications for the reader will be handled either via a CAT5 cable or RS485. When connecting via Ethernet standard Ethernet cables should be used and standard Ethernet distances should be adhered to. For RS485 communications standard CAT5 cable, a twisted pair 24AWG wire, can be used. It is also possible that a stranded cable can be used. In either case however it is recommended in a noisy environment that a shielded cable be utilized. For Wiegand communications it is recommended that you consider your environment to determine the need for shielded cable. The Rhino reader has the ability to send and receive Wiegand data. Wiegand output is typically used to send authentication data to a PACS panel. Wiegand input allows the reader to accept input from external Wiegand devices like a magnetic stripe reader. It is recommended that you adhere to standard Wiegand distance limitations of 500 feet and would use twisted pair cable from 20AWG to 24AWG. In addition TTL input provides a way to accept dual LED return and single line return, typically called Green LED and Red LED/Buzzer to provide user feedback such as Access Granted, Access Denied, and Enter PIN. TTL output provides a means of adding external authentication status devices such as stack lights. 2

Molex Connector Wiring It is best to wire both the Molex input/output and power connectors while they are free of the Rhino unit. Input/Output Connector: Power Connector: 3

Rhino board level view of connections: Input/Output Connections RS485 Wiegand The EIA-485 differential line consists of two pins: Pin 1 RS485-A, ' ', TxD-/RxD-, or inverting pin Pin 2 RS485-B, '+', TxD+/RxD+, or non-inverting pin The reader interface uses standard Wiegand wiring conventions. The Rhino reader uses Wiegand Out to send data to the PACS panel, and Wiegand In to receive data from an external device such as a magnetic stripe reader. Connect the wire properly to the terminal block on the appropriate board node. Following is a typical, but not universal, wiring guide. Refer to the Panel/Reader/Keypad Wiring Guide for guidelines related to your specific PACS, reader or keypad. Pin 3 Ground for Wiegand Input Device Typically black external input device wire. Ground for Rhino 5 VDC power for external Wiegand input devices. Pin 4 Power for Wiegand Input Device - Typically Red external input device wire. Supplies 5 VDC power for external Wiegand input devices. 4

TTL Relay Ground Pin 5 Wiegand In 0 - Typically orange reader wire to the DATA0 terminal. Used to receive data from an external Wiegand input device. Pin 6 Wiegand In 1 - Typically brown reader wire to the DATA1 terminal. Used to receive data from an external Wiegand input device. Pin 7 Wiegand Out 1 - Typically green reader wire to the DATA1 aka W1 aka Data Low terminal. Used to send data to a PACS panel or other external device. Pin 8 Wiegand Out 0 - Typically white reader wire to the DATA0 aka W0 aka Data High terminal. Used to send data to a PACS panel or other external device. TTL Out is typically used to convey authentication status to TTL LEDs, light stacks or to control external relays. TTL In is typically used to pass PACS panel Pass/Fail/PIN output back to the reader. Pin 9 TTL Out 1 - Output is 3 VDC Pin 10 TTL Out 2 - Output is 3 VDC Pin 11 TTL In 1 or Red LED/Buzzer Typically Brown wire from PACS panel Red LED/Buzzer Pin 12 TTL In 2 Typically Orange wire from PACS panel Green LED Relay Open/Close is typically used in environments where the reader is used independent of a PACS system. Relay can be used to control magnetic and electric strikes. Pin 13 RLY CO or Common Relay common Pin 14 RLY NO or normally open Example, electric door strike Pin 15 RLY NC or normally closed Example, magnetic door strike The ground pin should be connected to the PACS panel ground. Reader to panel communication issues are often traced back to an improper panel ground. PLEASE CONNECT TO PANEL GROUND. Pin 16 GND, Ground or Common Black external reader wire 5

6

Physical Installation Dimensions: Length: 10.31 Width: 5.94 Depth: 3.94 Weight: ~ 4lbs Material: Aluminum 7

8