Trafoguard reliable monitoring of Transformer operating statuses. Transformer control

Similar documents
tapcon 230 user-friendly, FleXiBle and reliable. transformer control

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control

AUTOMATING POWER TRANSFORMERS INTELLIGENT MONITORING, CONTROL AND REGULATION.

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control

TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS.

TAPCON 240 Voltage Regulator for Regulating Transformers

TAPCON 230 Voltage Regulator for Regulating Transformers

MSENSE BM MONITORING FOR BUSHINGS.

Monitoringsystem TAPGUARD 260

MTeC - EPT202 Digital thermometer Messko

Voltage regulator TAPCON 260

GRIDCON itap ON-LOAD TAP-CHANGER FOR DISTRIBUTION GRIDS. POWER QUALITY

Providing the missing piece in your Condition Based Monitoring platform

Timothy Cox Application and Support Engineer Dynamic Ratings Australia

Tap Manager TM100. Operating Instructions

Voltage regulator TAPCON 260

QUALITROL QTMS Transformer Monitoring System

Monitoringsystem TAPGUARD 260

Voltage regulator TAPCON 260

Voltage regulator TAPCON 240

EC 600 Electronic Volume Corrector

GRIDCON ACF ACTIVE FILTERS FOR CLEAN GRIDS. FOR ANY ENVIRONMENT. POWER QUALITY

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

1. General Information. 2. Application. 3. System configuration

Voltage Regulator TAPCON 230 expert

Monitoring System TRAFOGUARD

WAGO Energy Data Management Efficiency Is That Easy!

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Analog display for resistance current

with Backlight Graphic LCD Screen

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Product Specifications

DIAGNOSTICS PN# / / FSP

Extruder Controls ExtruVision S

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

FOUR FUNCTIONS ONE SOLUTION

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

Precision pressure indicator 1- or 2-channel version Model CPG2500

Building Control GAMMA instabus

Mains Quality PQ-ANALYZER CLASS A

Monitoring system TAPGUARD 240. Operating Instructions 244/04

the Centric 300 An advanced modular UPS up to 1800kVA/kW

Today, utilities are focusing on improving or maintaining

Voltage Regulated Distribution Transformer

PHS 1601 Point Heating Control. voestalpine SIGNALINGSainerholz GmbH

Digital On-Load Tap Changer Voltage Controller TAPCON 250 Operating Instructions (short version) BA 289

INTECONT PLUS for Measuring Systems

Product End-of-Life Announcement Portable Data Recorder HMG 3010

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Perfect protection smallest space

Tri-Phase. true 3-phase transformer turns ratio tester

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

Make the sun your energy source. SOLAR

POWER SUBSTATIONS. High available switches for power substations

Company main topic [ Product ] TracFeed DCP2. English. Multifunctional Device for Control and Protection in DC switchgear.

SIMOREG Still leading the field - after years of success

GAMATRONIC, A SolarEdge Division.

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Frequency Converter Fv SVC/FOC converters for universal applications

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.

Integrated monitoring system for power transformers and hydro generators as an asset management and "smart grid" component. Miroslav Poljak, Ph.

PROFIBUS with FBP. Achieve everything with fewer components. NEW: PDQ22-FBP The bus node with. four units ABB

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL

What is your drive? Simply get started? SINAMICS GM150: The uncomplicated medium-voltage AC drive. sinamics

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Customized for tomorrow today.

SIRIUS Motor Management and Control Devices

Neon pr. ph/ ORP measurement. Applications. Description

Product Information. POSITIP PT 8016 Digital Readout for Manually Operated Machine Tools

RTU modules Create your infrastructures with peace of mind!

Rack & Enclosure Systems

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

Model KT 53 Cooling incubators with thermoelectric cooling

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

control unit. Various interfaces ensure that it always has access to the latest data. Features of the FAFNIR technology

Voltage Regulator TAPCON

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

HYFRA Sigma. Efficient, reliable cooling water recooling systems. Customized. Cooling. Solutions.

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

Lecture 6 Substation Automation Systems

Grid Automation Controller COM600 How it fits into the Smart Grid?

Solution Oil & Gas. tgood.com

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

NEW! Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Package Substation. The efficient solution for your electrical distribution network

Online data sheet. Flow-X FLOW COMPUTER

Transportation Solutions LÜTZE Rail Technology. Product overview Control Technology

AC-DC Converter REC K10

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

BMF400 Input/output module

I/O module (Expansion module)

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Transcription:

Trafoguard reliable monitoring of Transformer operating statuses. Transformer control 2

Trafoguard Trafoguard money can't buy a better way of ensuring economic Transformer operation.

Trafoguard Trafoguard all-round Transformer safety. be on the safe side when operating on-load tap-changers and transformers. with our expert knowledge and Trafoguard. as the world market leader in tap changers, we already have an innovative monitoring system for our products. The monitoring systems available from maschinenfabrik reinhausen have proven themselves in monitoring tap changers around the globe. Trafoguard is a practical professional solution for monitoring the most important transformer functions. collecting, processing, displaying and forwarding operating data from transformers the Trafoguard combines all of these functions in one device. The modular system enables the basic module to be extended to suit the customer's needs by means of function packages that can be combined in various ways. These can be selected upon ordering or added at a later date. for users who want to do more than simply monitor power transformers, the Trafoguard allows additional functions such as cooling system control or even voltage regulation to be integrated. Power or distribution transformers? for both, Trafoguard increases transparency in terms of operating status, makes possible analysis of current and historical operating data (from up to 30 years ago) and helps you to detect critical operating statuses early on. Quick and reliable very simple to configure and user-specific parameterization thanks to the new TrafoseT software flexibly combinable maximum flexibility through monitoring packages that can be selected for specific customers and individually combined graphic display data is displayed in a clear and operatorfriendly way using Trafovisor visualization software and on the device diagnosis by experts individual visualization of operating data with the Trafovisor visualization software and data export 3

Know what's going on. monitoring systems from mr. more than 20 years of expertise in the monitoring field: This enables us to continuously develop and improve our monitoring systems. Trafoguard clear and operator-friendly display of data monitoring parameters, such as limit values or alarms, can be changed at any time using the TrafoseT and TaPcon trol parameterizing tools and therefore adapted to the current operating situation even remotely. 9 of 10 leds for free event and/or signal allocation with option of labeling clear graphics display (128 x 128 pixels) with logical, intuitive menu structure clear display of all current events life measured values (online monitoring) german/english can be selected as display language on device 9

Technical data and more: www.trafoguard.com. You can adapt the basic TRAFOGUARD device individually to your needs using various optional add-on modules. The functions can also be adapted or added to later on through individual signal allocation of the card inputs and outputs. Technical data TRAFOGUARD Device characteristics Housing 19 Dimensions 483 x 133 x 178 mm (W x H x D; 84 part unit x 3 height unit) Protection IP 20 in accordance with IEC 60529 Weight approx. 5 kg (depending on equipment) Operating temperature -25 C to +70 C Storage temperature -35 C to +80 C Display 128 x 128 pixels Control system communication IEC 61850; DNP 3.0 Voltage supply Multi-voltage mains unit 88-265V AC / DC 4.5 A DC mains unit 36-72V DC 4.5 A or alternatively DC mains unit 18-36V DC 4.5 A TRAFOGUARD Data storage of up to 45 measured values with adjustable recording interval. I Current measured values: data stored for 24 hours, recording interval of 1 minute I Historical measured values: data stored for 30 years, recording interval can be set to between 10 and 120 minutes 5

Trafoguard options for individual function PacKages. freely selectable function packages and variable hardware configurations allow the Trafoguard to record and process extensive transformer status information using a range of different sensors and to make this available to the operating staff via the Trafovisor visualization software. extended monitoring I Temperatures (oil temperature at bottom, ambient temperature two) I winding temperature 1 3-ph I dehydrating breather transformer/oltc I Pressure relief device transformer/oltc I buchholz relay I oil level of the conservator transformer, oltc cooling system control I control for up to six cooling stages I alternating operation/predictive mode I inflow temperature I outflow temperature I operating statistics automatic voltage regulation I Parallel operation (circulating reactive current; master/follower, topology) I line drop compensation (ldc, Z) dga I gas status (up to 9 gases) I moisture in oil (transformer, oltc) I Total gas content free inputs I analog and digital inputs motor current index basic monitoring* I 1-phase load voltage, load current (3-phase as an option) I effective, reactive and apparent power I Temperatures (surroundings, Topoil, hotspot) I Transformer aging rate I Tap-change statistics (numbers for hours/tap, tap-changes/tap and passes through neutral position) I maximum winding temperature I local/remote I motor running oltc I Tap position capture on-load tap-changer monitoring I oil temperature oltc I oil carbonization I contact wear I difference contact wear I maintenance recommendations I in accordance with ieee Pc57.143 56 *) basic equipment

Trafoguard interfaces. for integration in station/mains management systems, the Trafoguard monitoring is equipped with extensive communication functions. grid control level TrafoseT Trafovisor scada grid control center remote station level ethernet rj45/fo iec61850; dnp3.0 rj45/fo rj45 rj45 rsp20/25 local rs232 digital i/os; 4..20ma; PT100 Process level sensors: mr sensors: voltage/current Temperature: messko PT100, messko TT-Pwm60, messko TrasY compact, Oil: messko mto, messko mmk, messko mfloc Humidity: messko mtrab Protection: mr rs2001, messko mprec, messko msafe dga etc. various physical interfaces (e.g. rj 45 or fiber optic) are available for the iec61850 and dnp 3.0 control system protocols. by using a managed industrial switch, redundant ethernet connections are possible. 7

TRAFOGUARD TRAFOGUARD a system designed with maximum flexibility in mind. The Trafoguard system comprises three components, the Trafoguard device and the Trafoset and Trafovisor software packages. TRAFOSET simple commissioning and parameterization I Simple configuration of functions without changes to the firmware I Individual signal allocation of card inputs and outputs on the TRAFOGUARD I Simple parameterization of all analog and digital measurement signals, incl. limit values and events I Flexible LED assignment on the TRAFOGUARD I Optimization of TRAFOGUARD card population for customer-specific monitoring product requirements at the point when devices are ordered I Rapid establishment of connection to TRAFOGUARD device, data upload and download, firmware and configuration files I Convenient transfer of configured parameter files to the TRAFOGUARD 8

Trafoguard TRAFOSET software TRAFOVISOR software A new dimension in visualization thanks to TRAFOVISOR Emphasis was also given to maximum flexibility when developing the visualization and preparing the measured values. The TRAFOVISOR visualization interface clearly displays all measured values, events and binary statuses of the transformer on a PC either locally or in the control room for example. The displays of MR's TRAFOVISOR visualization interface can be adapted to the respective user requirements conveniently and displayed in the form of tables or graphics. Configurable plottexts, colors and line widths provide maximum scope for customization. TRAFOVISOR comprehensive visualization with graphic preparation of all the transformer's operating data on one PC I Local or remote access via Ethernet I Visualization of all current and historical measured values of binary statuses I Convenient depiction of all events in the event list I Minute-by-minute visualization updates for all current measured values, events and binary statuses I User-specific, configurable graphics I Export of all current and historical operating data in tables 10 9

Maschinenfabrik Reinhausen GmbH falkensteinstrasse 8 93059 regensburg, germany Phone: +49 941 4090-0 fax: +49 941 4090-7001 email: info@reinhausen.com www.reinhausen.com Please note: The data in our publications may differ from the data of the devices delivered. we reserve the right to make changes without notice. in2524335/02 en Trafoguard f0292002 04/14 uw maschinenfabrik reinhausen gmbh 2013 The Power behind Power.