CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

Similar documents
SAS Expander Card User s Manual CHENBRO. SAS Expander Card User s Manual. April / 01 /

CHENBRO CK port 6Gbit SAS Expander Card User s Manual. Version A0. September / 01 / 2010

CHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0

80H A0 80H A0 80H A0

CHENBRO. User s Manual SK to-1 SATA / SAS HDD Storage Kit. Version A2~A4. May / 26 / 2008

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H C0. User s Manual. September / 10 / 2009

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013

CHENBRO. 80H A0 Rev A0 User s Manual 01 / 03 / 2011

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008

CHENBRO. 6-Port 3Gb/s Mini-SAS Backplane 80H A0. User s Manual. August / 2010

CHENBRO. 8-Port 6Gb/s SATA Backplane 80H A0. User s Manual. September / 2010

Chenbro. ES34169 Chassis User s Manual. April / 2 /

In Win. Storage Chassis 10-Port 6Gb/s 2.5 Mini-SAS+SATA Backplane. User s Manual 2014/8/10

CHENBRO. 24-Port 3.5 mini-sas Backplane with Expander 80H A0. User s Manual. December 2012

In Win. Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane 3RAMPD User s Manual 10/02/2012

In Win. Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 2015/08/06

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

NA380A-G3. 4U 24-Bay External PCIe 8 JBOD Storage with PCIe Slot Expansion. User Manual

Storage Backplane Specifications

MegaRAID SAS e RAID Controller

RM414 User s Manual. Preliminary Release

SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE

SAS JBOD Installation Reference Guide Revision 1.0

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Syncro CS e Controller

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

A33606-AIC-02 User's Guide

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

CSE-M14T Mobile Rack USER'S GUIDE

SIDEBAND#2 3 JP43 JP37 JP45 JP38 JP41 J10 I C#2 JP36 JP50:I2CRST#1 JP38:I2CRST#2 OFF:SGPIO ON:I2C JP50 JP29 2 I C#1 JP40 JP44 JP51 JP29:9072 RESET

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

RMC HS. User Manual. Version 1.0

Intel Storage System JBOD 2000S3 Product Family

RS U, 1-Socket Server, High Performance Storage Flexibility and Compute Power

SATA II HDD Canister KISS DA 435 Quick Reference Guide

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Rocsecure NE52 NAS System

16 July r1 SAS-2 Add device slot numbering fields to DISCOVER

RACK-220 CHASSIS USER S MANUAL

Intel /100Mbps Ethernet Controller 32bit PCI Slot x2. ATI Rage XL Video Chip with 4MB Video RAM onboard 64bit PCI Slot x4

Quanta JB9 (M4600H) JBOD System Overview

DNS-2608 Enterprise JBOD Enclosure User Manual

Adaptec RAID Series 3 & 5 Competitive Matrix

05-023r0 SAS-1.1 Connector figures 23 December 2004

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

MegaRAID CacheVault Power Module 02

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2012

NEC EXPRESS5800/R320a-E4 Configuration Guide

Turbo PCI Express. PCI Express adapter for desktop PC. PCIe 4 to PCIe 4 data cable, 1.5 meter. Turbo ExpressCard. ExpressCard 34 adapter for laptop

NEC Express5800/R120e-1M System Configuration Guide

96RC-SAS-8P-PE-LS3. Test Report. This report is also applied to the following drives since they are same generation with very similar specification.

MegaRAID SAS i and SAS i RAID Controllers

Data Sheet FUJITSU Server PRIMERGY SX960 S1 Storage Blade Disk

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Dolphin DXE410 Expansion Chassis

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

RM12_1394B. User Manual. Ver Date: 02/2006.

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Flex System Storage Expansion Node Product Guide

ServeRAID-BR10i SAS/SATA Controller and IBM 3Gb SAS HBA v2 - New family of RAID controllers for System x servers

Dolphin DXE410 Expansion Chassis

NEC EXPRESS5800/R320b-M4 Configuration Guide

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Taurus - USB. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English)

4-Bay Enclosure for 3.5in SATA Drives - Thunderbolt 2 - RAID

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Data Sheet FUJITSU Storage ETERNUS JX40 S2 Subsystem

Taurus S2. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English )

Introducing Next Generation Media Application Server Hardware

Open Vault Storage SAS Expander Firmware Specification V1.0

Antec Signature Series

XD5300 Series. Product Highlights

IBM ServeRAID-BR10il SAS/SATA Controller offers a high performance SAS and SATA host bus adapter for direct attach storage

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

FWA-6280A User Manual 1. FWA-6280A User Manual

Data Sheet FUJITSU Storage ETERNUS JX60 Subsystem

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

User Manual ACP U Rackmount Chassis for ATX / MicroATX Motherboard or SHB / SBC

Oracle <Insert Picture Here>

DCT-24 USB Audio Center

Intel RAID Expander Card RES3FV288 Hardware User's Guide. Intel Order Number: H

JanusRAID SA-6692J Hardware User Manual

D-Storm Series. High-end Rackmount case. Installation and User Guide. Copyright 2004 istarusa, Inc.

Transcription:

CHENBRO CK12803 28-port SAS Expander Card Version B0 September / 01 / 2009 1

Copyright Copyright 2008 CHENBRO Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are copyrighted by CHENBRO Micom Co., Ltd.. All rights reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission. CHENBRO Micom Co., Ltd. reserves the right to make improvement and modification to the products indicated in this manual at any time. Specifications are therefore subject to change without prior notice. Information provided in this manual is intended to be accurate and reliable. However, CHENBRO Micom Co., Ltd., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use. Trademark All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including, but not limited to the following. intel is trademark of intel Corporation. LSI is trademark of LSI Corporation. Adaptec is trademark of Adaptec Inc. 3Ware is trademark of AMCC Corporation. Areca is trademark of Areca Technology Corporation. Technical Support CHENBRO works hard to offer our customers maximum performance from our chassis. But in case you have any problem with our product you can find supports from the following resources. Web Support Detail information of our products is in our website. You can find technical updates, installation guides, FAQs, technical specifications and more. Our web address is:. Email Support You can also fill out the technical support form at our Technical Support page. You technical issue inquiries will be sent directly to our support professionals. Phone Support You can also contact CHENBRO HQ or branch office for immediate support; their contact Information is as following: CHENBRO HQ CHENBRO Europe B.V. CHENBRO Micom (USA) Inc. Tel: 886-2-8226-5500 Tel: 31-40-295-2045 Tel: 1-909-947-3200 Fax: 886-2-8226-5423 Fax: 31-40-295-2044 Fax : 1-909-947-4300 2

Contents Copyright...2 Trademark...2 Technical Support...2 Contents...3 Revision History...4 Safety Information...5 Conventions Used in this Manual...5 Getting Start with SAS (Serial Attached SCSI) Expander Card...6 Unpacking and Checking the Contents...6 Technical Specifications...6 Introduction...7 About this Guide...7 Introducing the SAS Expander Card...7 Features...8 General...8 High-Speed I/O...8 Application...8 SAS Expander Card Hardware...9 SAS Expander Card Layout...9 HDD Failure LED Signal Connector...10 Firmware Setting Jumper...10 Mechanical Dimension...11 Cables...12 Chassis Assembly Example...13 Example for Host Application (RM31616)...13 Example for JBOD Application...14 Compatible SAS RAID Cards...15 3

Revision History Date Modifications Aug. / 01 / 2009 Sep. / 01 / 2009 First Release Update LED Indicating Information, Page 9 Add Input Port Usage, Page 10 Update SAS RAID Card Compatibility List, Page 15 4

Safety Information Read the installation instructions before connecting to the power source. Only trained and qualified personnel should be allowed to install, replace or service this equipment. Never install this product in a wet environment. Position system cables and power cables carefully; route system cable and the power cable and plug so that they cannot be stepped on or tripped over. Be sure that nothing rests on your system component cables or power cable. Conventions Used in this Manual The following conventions are used in this manual. Note Icon: Provides more information on the current topic. Important Icon: Provides important information on the current topic that must not be overlooked. 5

Getting Start with SAS (Serial Attached SCSI) Expander Card Thanks for purchasing CHENBRO SAS Expander Card! This section covers unpacking and identifying components. Unpacking and Checking the Contents The complete package includes the following items: Item Description Quantity Picture SAS Expander Card (ver. B0) 1 Cable, 350mm 1 Quick Guide 1 Technical Specifications Ports Internal Input from SAS RAID Card:4-port (1x ) Internal Output to Backplane:16-port (4x ) External Input from Host:4-port (1x ) External Output to Storage Center:4-port (1x ) Number of Supported SAS / SATA in directly 16 HDDs (Internal connection) connection of HDD Mechanical Dimension Refer to Page 11 Power Connector Type 4-Pin Connector Power Dissipation 12 Watts Operating Temperature 0~50 (32~122 ) Relative Humidity 20%~90%, non-condensing 6

Introduction About this Guide The SAS expander card user s manual provides the information for functions, capabilities, configuring and maintaining RAID arrays hosted by the expander card. Introducing the SAS Expander Card SAS expander card expands one SAS address to a number of additional ports. It is an optimal device for usage in data centers The CHENBRO 28-port SAS expander card provides high performance, high disk drive connectivity, scalability and flexibility in various storage environments. It is a valuable solution to other expansive and complex topologies. The SAS expander is ideal for high availability, scalable server clustering environments, front-end storage subsystems used in clusters, SANs and NAS environments. The CHENBRO SAS Expander is based on LSI SASX28 IC that enables the connection of multiple drive devices in directly attached SAS or SATA. Each expander PHY performs SAS and SATA transfer rate at 3.0 Gbit/s or 1.5 Gbit/s with individual configurations. The SAS expander IC supports the Serial SCSI Protocol (SSP), SATA Tunneled Protocol (STP) and Serial Management Protocol (SMP). Those are based on SAS protocol and described in the SAS standard v1.0 and V1.1. 7

Features General Flexible application of 28-port SAS Expander Card Support HDD Failure / Activity Indication and HDD ID Mapping Compatible with PCI-Express 4X, 8X, 16X & PCI slots on motherboard High-Speed I/O 1.5 Gbit/s or 3.0 Gbit/s operations Automatic negotiation of linking speed Application SAS / SATA HDD NAS storage sever or enclosure Security system Video streaming / editing workstation SAS expander card must be used only with SAS RAID card such as LSI Logic MegaRAID SAS 8888ELP 8

SAS Expander Card Hardware SAS Expander Card Layout 13 14 15 3 4 16 1 2 12 11 10 9 8 7 6 5 No. Components Description Function 1 CE1 2 CE2 3 CB1 SFF-8088 Connector External Input SFF-8088 Connector External Output SFF-8087 Connector Internal Input External Input from host External Output to storage center Internal input from SAS RAID card 4 CN3 DC in, 4-Pin Connector From power supplier 5 CD1~CD4 SFF-8087 Connectors Internal Output Output to SAS / SATA-II HDDs 6 CN04 Individual HDD Fault LED Connectors Indicates HDD faults, refer to page 10 7 CN05 Function Reserved 8 CN9 Firmware Setting Jumper 9 LED10 SAS Expander Status LED 10 LD01 Internal Input Status LED 11 LD03 External Output Status LED 12 LD02 External Input Status LED 13 JC2 Function Reserved Firmware function selection, refer to page 10 Green LED blinking indicates SAS Expander works / ready Green LED blinking indicates internal input link activity; Red LED indicates no signal connection Green LED blinking indicates external output link activity; Red LED indicates no signal connection Green LED blinking indicates external input link activity; Red LED indicates no signal connection 14 CN01 Firmware (F/W) Upgrade Connector Upgrade F/W to latest version 15 CN02 Function Reserved 16 JC1 & JC3 Function Reserved 9

Cable Connector Type SFF-8087 SFF-8088 Only ONE input port can be connected in one CK12803, and it will not work when connecting both external input port (CE1) & internal input port (CB1). The internal input connector CB1 is only available to connect with SAS RAID card / controller. It will not work when connecting other SAS expander products. CK12803 version B0 supports the internal SAS Sideband signal SFF-8485 (SGPIO) Interface. Connecting SAS RAID card and backplane with standard cable with side band, the HDD failure LEDs on backplane will be lit and indicate the corresponding HDD has failed or is in the Unconfigured-Bad state. In this configuration, use one CK12803 connects up to 16 HDDs directly. Side bands of both types of SAS connectors support the SGPIO interface. HDD Failure LED Signal Connector CK12803 provides two modes to indicate HDD failure LED. Connector CN04 is the cable direct-attach configuration. Direct attach is defined as a maximum of one HDD connected directly to each port. Indicates HDD faults for connector CD2 Indicates HDD faults for connector CD4 HDD Sequence 1 2 3 4 Indicates HDD faults for connector CD3 Indicates HDD faults for connector CD1 There is one LED per port (pin). When lit, each backplane LED indicates the corresponding HDD has failed or is in the Unconfigured-Bad state. Refer to the SAS RAID cards user s manual for more information about drive states. Firmware Setting Jumper Jumper set on pin 1 & 2: Enable the upgraded firmware version Default setting Jumper set on pin 2 & 3: Enable the original firmware version 10

Mechanical Dimension 11

Cables The backplane provides most benefits to users using the same backplane to support various SAS/SATA RAID card via different conversion cables. Chenbro provides various cables for different interfaces which include the followings: (A) (B) (C) Cable Type Host (RAID Card) Side Connector Backplane Side P/N Length A1 26H113215-027 200 mm A2 26H113215-028 350 mm A3 26H113215-029 500 mm A4 26H113215-030 600 mm B C (SFF-8088 36pin) (SFF-8088 36pin) 26H113325-003 860 mm SATA-7Pin x4 26H113215-009 450 mm, 500 mm 650 mm, 750 mm 12

Chassis Assembly Example See below for the example of how the wiring to be performed. Example for Host Application (RM31616) Slim FDD adaptor board LED Board Slim ODD adaptor board SAS RAID Card External output to JBOD or other device SAS Expander Card cable (SFF-8087 to SFF-8087) cable (SFF-8088 to SFF-8088) Fan Signal cable (BP to LED board) Slim ODD power cable Slim FDD power cable 13

Example for JBOD Application SAS RAID Card UEK External Output to Another JBOD LED Board BP cable (SFF-8087 to SATA) cable (SFF-8088 to SFF-8088) Chassis power On/Off & PSU alarm mute switch cable Fan Signal cable (BP to LED board) 14

Compatible SAS RAID Cards CK12803 Firmware Version AA11 ; Hardware Version B0 Manufacture Model Number Maximum Physical Drives per SAS RAID Card Verified Maximum Physical Drives Verified RAID Card Firmware Version SRCSASRB 32 32 1.40.32-0580 MegaRAID SAS 84016E 122 48 1.12.230-0598 MegaRAID SAS 8888ELP 240 48 1.40-42-0615 ARC-1680 128 48 V1.46 5445 256 48 5.2-0 (16501) 5805 256 48 5.2-0 (16501) 9690SA 128 48 FH9X 4.08.00.006 Rocket 4320 128 48 V1.2.17.19 Rocket 4321 128 48 V1.2.17.19 The maximum quantity of supported physical drives per SAS RAID Card is depended on the capability of the SAS RAID card in the system. Refer to the technical document or user guide provided by RAID card manufacturer. 15