Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014. Rackserver Open-E Unified Storage 15 TB O2212iR system

Similar documents
Certification Document GRAFENTHAL GmbH R2208 S2 01/04/2016. GRAFENTHAL GmbH R2208 S2 Storage system

Certification Document Supermicro SSG-6027R-E1R12T 04/30/2014. Supermicro SSG-6027R-E1R12T system

Certification Document macle GmbH IBM System xx3650 M4 03/06/2014. macle GmbH IBM System x3650 M4

HA Certification Document TAROX ParX R208s G5 03/26/2014. Open-E High Availability Certification report for TAROX ParX R208s G5

Open-E High Availability Certification report for Intel Server System R2224GZ4GC4

Certification Document Starline NASdeluxe NDL-4224R/L 06/24/2015. Starline Computer GmbH NASdeluxe NDL-4224R/L Storage system

Certification Document HP Proliant DL380 G7 12/22/2011. HP Proliant DL380 G7 storage system

HA Certification Document Happyware HW-OPE2123-R1 07/04/2013. Open-E High Availability Certification report for Happyware HW-OPE2123-R1

HA Certification Document Broadberry CyberStore 424S 05/17/2013. Open-E High Availability Certification report for Broadberry CyberStore 424S

HA Certification Document Dell PowerEdge R720 07/24/2013. Open-E High Availability Certification report for Dell PowerEdge R720

Lenovo RD240 storage system

Intel SR2612UR storage system

ReadyNAS OS 6 Desktop & Rackmount Performance

10/08/2010 Please see the part number system chart on page 8 for all red X, Y, R and Z s. Page1

CompTIA ISS-001. Intel Server Specialist Certification. Download Full Version :

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP

HyperScalers JetStor appliance with Raidix storage software

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Cisco Connected Safety and Security UCS C220

Sun Lustre Storage System Simplifying and Accelerating Lustre Deployments

10Gb iscsi Initiators

TECHNICAL REFERENCE. XTAccess High Performance 3U Hardware Manual / TR-XTA3-2500B

EMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture

NEC Express5800/R120e-2E Configuration Guide

IOPStor: Storage Made Easy. Key Business Features. Key Business Solutions. IOPStor IOP5BI50T Network Attached Storage (NAS) Page 1 of 5

SurFS Product Description

Surveillance Dell EMC Storage with Synectics Digital Recording System

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays

Benefits of 25, 40, and 50GbE Networks for Ceph and Hyper- Converged Infrastructure John F. Kim Mellanox Technologies

2018 QSAN XCubeNAS. XN8016R / XN8024R Introduction

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage

Storage Adapter Testing Report

NEC Express5800/R120d-2M Configuration Guide

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

Dell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain

NEC Express5800/R120f-1M System Configuration Guide

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Assessing performance in HP LeftHand SANs

What is QES 2.1? Agenda. Supported Model. Live demo

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server

Q500-P20 performance report

NEC Express5800/R120e-1M System Configuration Guide

NexentaStor 5.x Reference Architecture

Technical Presales Guidance for Partners

TELECOMMUNICATIONS TECHNOLOGY ASSOCIATION JET-SPEED HHS3124F / HHS2112F (10 NODES)

Extreme I/O Expandability with High VR Power Efficiency

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary

StorPool System Requirements

Milestone Solution Partner IT Infrastructure Components Certification Report

DEDICATED, SUPERIOR DATA SECURITY AND SUSTAINABILITY HIKVISION HYBRID SAN STORAGE PRODUCTS.

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

Surveillance Dell EMC Storage with Verint Nextiva

Vess A2000 Series. NVR Storage Appliance. Milestone Surveillance Solution. Version PROMISE Technology, Inc. All Rights Reserved.

VX1800 Series Unified Network Storage

STOR-LX. Features. Linux-Based Unified Storage Appliance

Altos T310 F3 Specifications

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/B110d Configuration Guide

Avid Configuration Guidelines Dell T7600 Dual Six-Core / Dual Eight-Core CPU Workstation Media Composer 6.x Symphony 6.x NewsCutter 10.

Acer AR320 F1 specifications

N8900 HDD Compatibility List

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Cisco UCS C24 M3 Server

CA AppLogic and Wiwynn SV320 Equipment Validation

STOR-LX2. Features. Linux-Based Unified Storage Appliance

Avid Configuration Guidelines HP Z820 Dual Six-Core / Dual Eight-Core CPU Workstation

All product specifications are subject to change without notice.

High Performance Computing

VX3000-E Unified Network Storage

High-speed rackmount NAS for SMBs with two 10GbE SFP+ ports & one PCIe slot for expansion

Virtual Environment For Yemen Mobile

Avid Configuration Guidelines Dell T5610 Dual 6-Core, Dual 8-Core & Dual 12-Core CPU Media Composer Symphony NewsCutter 10.5.

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

NEC Express5800/B120e-h System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide

Avid Configuration Guidelines Apple Mac Pro Ivy Bridge 6-Core, 8-core or 12-core CPU Workstation

Avid Configuration Guidelines Dell Precision T Core, CPU Workstation Media Composer Symphony NewsCutter 10.5.

NEC Express5800/B120d-h System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide

Chaz Stevens Director of Marketing

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

Barracuda Backup Hardware Specifications

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

Surveillance Dell EMC Storage with Milestone XProtect Corporate

Backup Appliances. Geir Aasarmoen og Kåre Juvkam

IBM Scale Out Network Attached Storage (SONAS) using the Acuo Universal Clinical Platform

Vess A2000 Series NVR Storage Appliance

Page 1 of 18 Dave Pimm Avid Technology Dec 6th, 2013 Rev B

NEC Express5800/R120h-1M System Configuration Guide

Hitachi Virtual Storage Platform Family

Cisco UCS C240 M3 NEBS High-Density Rack Server (Small Form Factor Disk Drive Model)

Building a home lab : From OK to Bada$$$ By Maxime Mercier

Rack Systems. OpenBlade High-Density, Full-Rack Solution Optimized for CAPEX & OPEX

Acer AW2000h w/aw170h F2 Specifications

NexentaVSA for View. Hardware Configuration Reference nv4v-v A

Intel Xeon E v4, Windows Server 2016 Standard, 16GB Memory, 1TB SAS Hard Drive and a 3 Year Warranty

IBM Storwize V7000 Unified

The QM2 PCIe Expansion Card Gives Your NAS a Performance Boost! QM2-2S QM2-2P QM2-2S10G1T QM2-2P10G1T

Transcription:

Rackserver Open-E Unified Storage 15 TB O2212iR system 1

Executive summary After performing all tests, the Rackserver Open-E Unified Storage 15 TB O2212iR has been officially certified according to the Open-E Hardware Certification Program Guide 2.1. During the tests, it was found that the system is functional and efficient. With the Open-E DSS V7 operating system installed, the Rackserver Open-E Unified Storage 15 TB O2212iR is stable and performs well. In general, the system can be used for many different applications, but the following are recommended: iscsi storage The following features make Rackserver Open-E Unified Storage 15 TB O2212iR good iscsi storage: Hardware RAID 10 with hot spare disk for high performance and data safety. Four 1GbE interfaces for fast MPIO connection and flexible network topology. Redundant power supply for system reliability. NAS filer For this application the following can be used: Eleven high capacity, enterprise class SAS hard drives provide a plenty of space for user files. Hardware RAID 10 with hot spare disk for increased IOPS and data safety. Four 1GbE interfaces for independent connection to different networks or link aggregation for improved throughput. Storage for CCTV For this application the following can be used: Eleven enterprise class SAS hard drives provide a lot of space for CCTV records. Four 1GbE interfaces for independent connection to different networks or link aggregation for improved throughput. Redundant power supply for system reliability. Certification notes We recommend using Balance-alb bonding mode for link aggregation. 2

Rackserver Open-E Unified Storage 15 TB O2212iR hardware components... 4 Rackserver Open-E Unified Storage 15 TB O2212iR photos... 5 Auxiliary systems hardware components... 6 Administration functionality... 7 Network functionality... 8 Network test topology... 8 802.3ad bonding mode test... 9 Balance-alb bonding mode test... 10 Balance-rr bonding mode test... 11 Single NIC performance test... 12 RAID functionality... 13 RAID test topology... 13 Hardware RAID10 test... 14 NAS functionality... 15 NAS test topology... 15 SMB test... 16 iscsi functionality... 17 iscsi Initiator test topology... 17 iscsi Target test topology... 17 iscsi Initiator test... 18 iscsi Target test... 19 3

Rackserver Open-E Unified Storage 15 TB O2212iR hardware components Technical specifications about the certified system are listed below: Model Rackserver Open-E Unified Storage 15 TB O2212iR Operating system Open-E DSS V7 build 10529 Enclosure/chassis CPU Motherboard Memory Network Chenbro RM23512E2-LE Intel Xeon E5-2403 1.80GHz Intel Server Board S1400FP4 8GB Kingston KVR16E11/8 DDR3 ECC Intel Ethernet Controller I350-AM4 HW RAID LSI MegaRAID SAS 9271-4i Hard disk drives 11x 3TB HGST Ultrastar 7K4000 HUS724030ALS640 TABLE 1: Hardware components list of Certified System with Open-E DSS V7 4

Rackserver Open-E Unified Storage 15 TB O2212iR photos FIGURE 1: Front photo FIGURE 2: Rear photo FIGURE 3: Top photo 5

Auxiliary systems hardware components Auxiliary systems with MS Windows or Open-E DSS V7 installed, used in Open-E Hardware Certification Process. Model Operating system Enclosure/chassis Motherboard CPU Memory Network Hard disk drives Custom MS Windows Server 2012 R2 Inter-Tech IPC 4088 4HE Asus P8B-E/4L Intel Xeon E3-1230 3.20 GHz 3x 4GB DDR3 Kingston KVR1333D3E9S/4G 4x Intel 82574L Gigabit Ethernet Controller 1TB Hitachi Ultrastar A7K2000 HUA722010CLA330 TABLE 2: Hardware components of first Workstation with MS Windows Model Operating system Enclosure/chassis Motherboard CPU Memory Network Hard disk drives Custom MS Windows Server 2012 R2 Inter-Tech IPC 4088 4HE Asus P8B-E/4L Intel Xeon E3-1230 3.20 GHz 3x 4GB DDR3 Kingston KVR1333D3E9S/4G 4x Intel 82574L Gigabit Ethernet Controller 1TB Hitachi Ultrastar A7K2000 HUA722010CLA330 TABLE 3: Hardware components of second Workstation with MS Windows Model Custom Operating system Open-E DSS V7 build 10529 Enclosure/chassis Inter-Tech IPC 4088 4HE Motherboard Asus P8B-E/4L CPU Intel Xeon E3-1230 3.20 GHz Memory 3x 4GB DDR3 Kingston KVR1333D3E9S/4G Network 4x Intel 82574L Gigabit Ethernet Controller Hard disk controller Intel RAID Controller RS2WC080 Hard disk drives 500GB Hitachi Deskstar 7K1000.C HDS721050CLA362 Hard disk drives 8x 1TB Hitachi Ultrastar A7K2000 HUA722010CLA330 TABLE 4: Hardware components of Workstation with Open-E DSS V7 6

Model Description Supermicro SSE-G24-TG4 24-ports 1GbE and 4-ports 10GbE switch TABLE 5: Network switch details Administration functionality The following functionality has been tested. Drive identifier Power button Front and rear LEDs OK OK OK TABLE 6: Administration functionality test results 7

Network functionality Tests performed in this section check the functionality, performance and stability of the network solutions available in the Open-E DSS V7 product on the certified system. The tests rely on configuring the iscsi targets and copying the data from many Workstations with MS Windows through various network connections with big block size using appropriate testing tools. Network test topology Network topology for Network testing is shown below. FIGURE 4: Network topology for Network testing 8

802.3ad bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through an 802.3ad bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test results for 802.3ad bonding mode test performed on Intel Ethernet Controller I350-AM4 802.3ad bonding mode performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM4 Write speed Read speed Performance test results 1 st Workstation 109.19 111.97 passed 2 nd Workstation 108.21 111.93 passed 3 rd Workstation 110.27 55.59 passed 4 th Workstation 109.34 56.91 passed TABLE 7: 802.3ad bonding mode performance test results table for Intel Ethernet Controller I350-AM4 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 5: 802.3ad bonding mode performance test results chart for Intel Ethernet Controller I350-AM4 9

Balance-alb bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-alb bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test results for Balance-alb bonding mode test performed on Intel Ethernet Controller I350-AM4 Balance-alb bonding mode performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM4 Write speed Read speed Performance test results 1 st Workstation 108.87 111.95 passed 2 nd Workstation 109.19 111.97 passed 3 rd Workstation 110.05 111.94 passed 4 th Workstation 109.11 111.94 passed TABLE 8: Balance-alb bonding mode performance test results table for Intel Ethernet Controller I350-AM4 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 6: Balance-alb bonding mode performance test results chart for Intel Ethernet Controller I350-AM4 10

Balance-rr bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-rr bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test results for Balance-rr bonding mode test performed on Intel Ethernet Controller I350-AM4 Balance-rr bonding mode performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM4 Write speed Read speed Performance test results 1 st Workstation 110.54 69.54 passed 2 nd Workstation 109.75 69.53 passed 3 rd Workstation 110.18 68.95 passed 4 th Workstation 110.68 69.08 passed TABLE 9: Balance-rr bonding mode performance test results table for Intel Ethernet Controller I350-AM4 1st Workstation 2nd Workstation 3rd Workstation 4th Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 7: Balance-rr bonding mode performance test results chart for Intel Ethernet Controller I350-AM4 11

Single NIC performance test 1. Test description The test relies on configuring the iscsi targets and copying the data from Workstations with MS Windows through single NIC with a 4MB block size using the Iometer testing tool. 2. Test results for single NIC test performed on Intel Ethernet Controller I350-AM4 Single NIC performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM4 Write speed Read speed Performance test results 1 st Workstation 110.51 111.93 passed TABLE 10: Single NIC performance test results table for Intel Ethernet Controller I350-AM4 1st Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 8: Single NIC performance test results chart for Intel Ethernet Controller I350-AM4 12

RAID functionality Tests performed in this section check the functionality, performance and stability of Open-E DSS V7 storage devices on the certified system. Tests in this section rely on the creation of the RAID units on 10 level, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. RAID test topology Network test topology for RAID testing is shown below FIGURE 9: Network test topology for RAID testing 13

Block size [KB] Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014 Hardware RAID10 test 1. Test description The test relies on creation of the RAID10 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for RAID10 and Intel Ethernet Controller I350-AM4 RAID10 performance test results Block size [KB] Write speed Read speed Performance test results 4 31.18 46.13 passed 32 71.95 110.94 passed 64 79.87 111.88 passed 128 90.41 111.78 passed 256 107.95 111.97 passed 512 110.59 112.02 passed 1024 107.94 112.01 passed 4096 110.44 111.88 passed TABLE 11: RAID10 performance test results table for Intel Ethernet Controller I350-AM4 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 10: RAID10 performance test results chart for Intel Ethernet Controller I350-AM4 14

NAS functionality Tests performed in this section check the functionality, performance and stability of the NAS protocols in the Open-E DSS V7 product on the certified system. The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. NAS test topology Network topology for NAS testing is shown below. FIGURE 11: Network topology for NAS testing 15

Block size [KB] Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014 SMB test 1. Test description The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for SMB and Intel Ethernet Controller I350-AM4 SMB performance test results Block size [KB] Write speed Read speed Performance test results 4 66.13 59.58 passed 32 112.47 112.65 passed 64 112.10 112.67 passed 128 112.21 112.74 passed 256 112.85 112.76 passed 512 112.90 112.78 passed 1024 112.87 112.69 passed 4096 112.76 112.60 passed TABLE 12: SMB performance test results table for Intel Ethernet Controller I350-AM4 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 12: SMB performance test results chart for Intel Ethernet Controller I350-AM4 16

iscsi functionality Tests performed in this section check the functionality, performance and stability of the iscsi protocol in the Open-E DSS V7 product on the certified system. iscsi Initiator test topology Network topology for iscsi Initiator testing is shown below. FIGURE 13: Network topology for iscsi Initiator testing iscsi Target test topology Network topology for iscsi Target testing is shown below. FIGURE 14: Network topology for iscsi Target testing 17

Block size [KB] Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014 iscsi Initiator test 1. Test description The test relies on using the storage connected via the built-in iscsi Initiator for NAS volumes, creating SMB shares on these NAS volumes and copying data from a Workstation with MS Windows to them with various block sizes using the Iometer testing tool. 2. Test results for iscsi Initiator and Intel Ethernet Controller I350-AM4 iscsi Initiator performance test results Block size [KB] Write speed Read speed Performance test results 4 64.90 60.14 passed 32 109.63 112.60 passed 64 110.35 112.54 passed 128 109.75 112.73 passed 256 109.71 112.77 passed 512 110.63 112.76 passed 1024 109.94 112.60 passed 4096 109.52 112.59 passed TABLE 13: iscsi Initiator performance test results table for Intel Ethernet Controller I350-AM4 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 15: iscsi Initiator performance test results chart for Intel Ethernet Controller I350-AM4 18

Block size [KB] Certification Document Rackserver Open-E Unified Storage 15 TB O2212iR 06/04/2014 iscsi Target test 1. Test description The test relies on creating the iscsi target on the certified system and copying the data from a Workstation with MS Windows to it with various block sizes using the Iometer tool. 2. Test results for iscsi Target and Intel Ethernet Controller I350-AM4 iscsi Target performance test results Block size [KB] Write speed Read speed Performance test results 4 32.05 47.10 passed 32 65.46 110.67 passed 64 72.56 111.77 passed 128 86.62 111.97 passed 256 107.59 111.98 passed 512 110.39 112.00 passed 1024 108.69 111.97 passed 4096 110.68 111.89 passed TABLE 14: iscsi Target performance test results table for Intel Ethernet Controller I350-AM4 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 16: iscsi Target performance test results chart for Intel Ethernet Controller I350-AM4 19