Non-communicating room controllers

Similar documents
Non-communicating room controllers

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Extension module for lighting control

Temperature controller Ducted systems

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Temperature Controller

Room unit with PPS2 interface

Room unit with PPS2 interface

Automation stations compact model

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Room Temperature Controller

Electrical Actuators

Room unit with PPS2 interface

Temperature controller Multi-zone ducted systems

Electrical Actuators

Room Temperature Controller

Room Temperature Controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Electrical Actuators

PXR11 PXR12. System controllers DESIGO PX

Room unit with PPS2 interface

Universal Controller

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Temperature controller for multi-zone ducted systems

Power supply module, bus connection module

EYE 200: DDC single-room controller, ecos200

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Semi flush-mounted room temperature controllers with LCD

Heating Circuit Controller

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Heating Circuit Controller

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Communicative controller for VAV systems

M-Bus Central Unit. Use

Semi flush-mounted room temperature controllers with LCD

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Master room unit for RRV controllers

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Compact Universal Controllers

EY-EM : Remote I/O module, ecolink

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Zelio Control-modular measurement and control relays 1

SEH62.1. Digital Time Switch

Operating instructions. Switching amplifier DN0210 DN / / 2015

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

7-day room temperature controller

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Supplementary operating instructions for your air curtain system Controller TMC 500

Product and functional description

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

VAV compact controller GDB181.1E/3 GLB181.1E/3

Millenium II +: general characteristics

FCU-4 FAN COIL CONTROLLER

ECL Comfort V a.c. and 24 V a.c.

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

Semi Flush-mount Room Temperature Controllers with LCD

Super universal modules

R7426A TEMPERATURE CONTROLLER WITHOUT REAL-TIME CLOCK. MicroniK 200. Order Numbers

Temperature Controller (Heat Pumps)

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Digital input modules

RCF-230CTD. Built-in or external sensor The controller has a built-in sensor. Alternatively, the input for an external PT1000-sensor can be used.

Actuators AME 655, 658 and 659 can be controlled by electronic controllers with modulating or 3-point control output.

Overview of types. Technical data

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

Programmable controller MCX06D

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

MINI-PS AC/10-15DC/8

Immersion Temperature Sensors

Pre-programmed room controller with display and communication

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

MINI MCR-SL-UI-REL(-SP)

RWD68U Universal Controller

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Expansion Module HZS 541-1S

RTD-W Installation Instructions

Automation station, compact series

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Programmable controller Type MCX06C

TAC Xenta 121-FC Programmable Fan Coil Application

MCX08M2 Programmable controller

Compact universal controllers

Electromotoric actuators

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

EY-RC 208, 209: Room automation stations, ecos208, 209

Programmable controller MCX152V

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Transcription:

3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems, with or without changeover Control of AC 24 V PWM 1) thermic valve actuators, 3-position AC 24 V valve and damper actuators, or electric heating coils Volt-free relay contacts for fan control and electric heating coils PI control AC 230 V operating voltage 1) PWM = pulse-width modulated Use The RXA20.1, RXA21.1 and RXA22.1 room controllers are optimised for control of fancoil systems in individual rooms. Theycanbeusedforthefollowing: RXA20.1: Single-speed automatic fan control, thermic valves RXA21.1: 3-speed automatic fan control, thermic or motorised valves RXA22.1: 3-speed automatic fan control, thermic valves with built-in relay for electric re-heating CA23881en 08.2001 Siemens Building Technologies Building Automation

Functions The controller application and the configuration of connected field devices are defined manually with DIP switches and a potentiometer. For a detailed description of functions, refer to the DESIO RXA applications library, document CA2A3886. Types The RXA20.1, RXA21.1 and RXA22.1 room controllers differ only in the number of outputs available: Type AC 24 V triac outputs Relay outputs RXA20.1/FC-01 For two thermic valve actuators For single-speed fan control RXA21.1/FC-02 For two thermic valve actuators For 3-speed fan control or two 3-position actuators RXA22.1/FC-03 For two thermic valve actuators For 3-speed fan control; built-in relay for electric heating coil RXZ20.1 Accessories: terminal covers Ordering When ordering, please specify the quantity, product name and type code. The RXZ20.1 terminal covers are supplied in packs of 10 pairs and must be ordered as a separate item (see also Mounting ). Example: 30 Room controllers, type RXA20.1 RXA20.1/FC-01 30 Pairs of terminal covers RXZ20.1 Compatibility The QAX3 room units and the Siemens Building Automation field devices are suitable for use with the RXA20.1, RXA21.1 and RXA22.1 room controllers. For details, refer to the product range description, document CA2S3880. 2/14

Design The RXA20.1, RXA21.1 and RXA22.1 room controllers consist of a housing base, a housing cover and the printed circuit board. The printed circuit board incorporates the connection terminals and the DIP switches used for configuration. The controllers also have a potentiometer for setpoint adjustment and testing, and a Service ED with different flashing patterns to indicate operational status and test states. Connection terminals 00608 Cable restraints DIP switches Housing cover Housing base Connection terminals Service ED Potentiometer Terminal cover Terminal covers (RXZ20.1) are available as an option, to protect the connection terminals from physical contact and dirt. The Service ED and the potentiometer remain visible even with the terminal covers fitted. The potentiometer can be operated with a screwdriver. The cable is connected to the room controller by breaking out the perforated cable entry guide. 70200 Removing the terminal cover abel (example for RXA21.1) Protection standard 00607 a Temperature range (0 50 C) Serial o. Test date, series (Z,A,B,C ) 010311Z 513 Observe notes in this document Programmed application ocation 3/14

ote Options for use of the labeling fields Appl. and oc. : Handwritten entry of location and the final application or Printed adhesive label Connection terminals To avoid incorrect wiring, terminals which can be connected to AC 230 V (supply and relay outputs) are physically separate from the other terminals. STOP Caution The cable restraints on the housing base must be used for the connections to terminals 19 28 (AC 230 V). The conductors must be secured with cable ties (see diagram). 80160 Disposal The controller includes electrical and electronic components and must not be disposed of as domestic waste. Current local legislation must be observed. Engineering For information on selecting and sizing the cables for the power supply and for the field devices, refer to the installation guide, document CA2Z3884. The room controllers have an AC 230 V mains supply voltage. The controlled devices (valves and damper actuators) are supplied directly from the room controller. This means that a separate AC 24 V supply is not necessary for the RXA20.1, RXA21.1 and RXA22.1 controllers and the associated field devices. Master/slave AC 230 V supply cables AC 230 V volt-free relay outputs Where several room controllers are operating in the same space, they must be synchronized via the master/slave interface Up to 3 slaves may be used (operating in parallel) The outputs of the master controller are mapped in the slaves. ote that room units connected to a slave controller cannot be operated The polarity of the M/S wires has to be respected! The master/slave interface is compatible with the PRFA and PRFB controllers in the PROTO range Sizing and fuse protection of the supply cables depends on the total load and on local regulations. The cables must be secured with cable restraints. The volt-free relay outputs allow switching of loads up to AC 250 V, 5 A (4 A). The heating coil relay in the RXA22.1 switches resistive loads up to 1.8 kw. The cable dimensions depend on the connected load and the local installation regulations. The circuits must be externally fused (max. 10 A) as there are no internal fuses. The cables must be secured with cable restraints. STOP Caution The fans must not be connected in parallel. 4/14

AC 24 V triac outputs The simultaneous load on outputs Y4 must not exceed 9.5 VA. Example: (heating) 2 thermic valve actuators, type STE72 6 W Y2 (cooling) 2 thermic valve actuators, type STE72 6 W Y3, Y4 (outside air) Damper actuator 3.5 VA 3.5 VA The maximum load is 9.5 VA for the heating sequence and 9.5 VA for the cooling sequence. This is acceptable because the two sequences never operate at the same time. Mounting instructions The room controllers can be mounted in any orientation using the following fixing options: 00609 00610 Rail mounting The housing base is designed for snapmounting on DI rails, type E50022-35x7.5 (can be released with a screwdriver) Surface mounting There are two drill holes for screwmounting (see Dimensions for drilling template). The housing base is fitted with raised supports. Screws: Max. diameter 3.5 mm, min. length 38 mm When mounting note the following: The controller should not be freely accessible after mounting Ensure adequate air circulation to dissipate heat generated during operation. Easy access is required for service personnel ocal installation regulations must be observed. Mounting instructions and a drilling template are printed on the controller packaging. Commissioning The controller application and the configuration of the connected field devices are defined manually with DIP switches and the potentiometer. The Service ED provides information on power up and operational status. There is no special test for checking that the connected field devices match the DIP switch settings. Depending on the application, if the controller has insufficient information it switches to "Idle" mode (all outputs at zero) and the ED remains on continuously. For details refer to the applications library CA2A3886. STOP Caution In the event of a long-term short circuit or overload, the thermal fuse in the transformer may trip. The controller must then be replaced. There is no protection against accidental connection with 230 V on the AC 24 V side. 5/14

Technical data Power supply Working voltage AC 230 V ± 10 % Frequency 50/60 Hz Power consumption with output field devices connected Max. 12 VA Internal fuse Thermal, non-resetting Operating data Control algorithm PI Inputs Signal inputs D1 D3 (for volt-free contacts) Quantity 3 Contact voltage DC 16 V Contact current DC 8 ma Contact transfer resistance Max. 100 Ω Contact insulation resistance Min. 50 kω ot suitable for pulse control Measured value inputs B1 and X2 Type of signal is programmable (DIP switch) &S i 1000 temperature sensor, setpoint adjuster or 0 10 V signal Temperature sensor &S i 1000 Measuring range 0... 50 C Sensor current 2.3 ma Resolution 0.2 K Measuring error at 25 C sensor temp. (without Max. 0.2 K cable) Setpoint adjuster BS-U1 Reset range +/ 3K Setpoint reset signal 0 10 V RK-S for summer/winter compensation See data sheet CA23389 Outputs AC24 V triac outputs, Y4 Quantity 2 (RXA20.1, RXA22.1) 4 (RXA21.1) Output voltage (SEV, not earthed) AC 24 V O/OFF, PWM or 3-position (depending on application) Output current Max. 0.5 A Total nominal load (at both outputs simultaneously) Max. 9.5 VA (e.g. 2 thermic valves, type STE72 per heating and cooling sequence + 1 damper actuator 3.5 VA) Relay outputs Q14, Q24, Q34 External fuse Max. 10 A Quantity 1 (RXA20.1) 3 (RXA21.1, RXA22.1) Relay type Monostable Contact rating with AC voltage Switching voltage Max. AC 250 V, min. AC 19 V ominal current, resistive/inductive Max. AC 5 A/4 A (cos ϕ = 0.6) Making current 200 ms half-time Max. 20 A Switching current at AC 19 V Min. AC 10 ma Contact rating with DC voltage Switching voltage Max. DC 250 V, min. DC 5 V Switching current at DC 5 V Min. DC 100 ma Switching capacity Max. 20 W Inductive load /R Max. 7 ms Q44 External fuse (essential) Max. 10 A Relay type Monostable Max. admissible load (resistive only) Max. 1.8 kw Interfaces Interface to room units Interface type PPS2 Master/slave interface Proprietary Max. number of slaves 3 Cable connections Connection terminals for signals and power supply (screw terminals) Stranded or solid conductors, 0.25 2.5 mm 2 or (solid conductors only) 2 x 1.5 mm 2 6/14

Single cable lengths Signal inputs D1. D3 Max. 100 m with diameters 0.6 mm Measured value inputs B1 and X2 Max. 100m where A 1.5 mm 2 AC24 V triac outputs, Y4 Max. 100m where A 1.5 mm 2 Relay outputs Q14, Q24, Q34, Q44 Depends on load and local regulations Interface to room units (PPS2) Max. 115 m where A = 0.75 mm 2 Interfacetoslaves Max.50mwhereA=0.75mm 2 Cable type 2-core, twisted pair, unscreened Housing protection standard Protection standard to E 60529 IP30 with terminal cover fitted and wall mounted without DI rail IP20 for all other mounting arrangements Protection class Suitable for use in systems with protection class I or II Ambient conditions Operation Transport Class 3K5 to IEC 60721-3-3 Class 2K3 to IEC 60721-3-2 Temperature 0... 50 C 25... 65 C Humidity <85%rh <95%rh Industry standards Product safety Automatic electronic controls for household and similar use E 60730-1 Special requirements for energy controllers E 60730-2-11 Electromagnetic compatibility Interference immunity E 50082-2 Emitted interference E 50081-1 Meets the requirements for CE marking: EMC Directive 89/336/EEC ow Voltage Directive 73/23/EEC Dimensions See dimension diagrams Weight Excluding packaging 0.59 kg 7/14

Connection terminals and operator controls RXA20.1 00600 a 1 2 3 4 5 6 7 8 9 10 11 12 13 O DIP B1 M X2 D1 D D2 D3 Y2 T 5(4) A PPS2 2 1 Q13 Q14 M/S CP- CP+ 1 2 3 4 5 6 7 8 910 S1...10 T 0...10 V AC 230 V R1 19 19 21 21 25 26 14 15 16 Measured value inputs B1 1 Measured value input for &S i 1000 sensor or setpoint adjuster M 2 Measured value input ground X2 3 Configurable input for &S i 1000 sensor, setpoint adjuster or 0 10 V signals Signal inputs D1 4 Signal input (window or clock) D 5 Signal ground D2 6 Signal input (occupancy) D3 7 Changeover input Triac outputs 8 AC 24 V, 0.5 A switching output 9 AC 24 V actuator supply Y2 10 AC 24 V, 0.5 A switching output Device bus M/S 14 Master/slave connection CP 15 round for PPS2 and M/S CP+ 16 PPS2 (room unit) Power supply 19 eutral conductor 21 Phase conductor AC 230 V +/- 10 % Relay outputs Q13 25 ead wire for Q14 Q14 26 ormally-open contact max. AC 250 V, 5 (4) A Operator controls S1...10 DIP switch for configuring the room controller. R1 Potentiometer for setpoint reset and test purposes. STOP Caution Observe the technical data for the relay output: max. AC 250 V, 5 (4) A Important ocal installation regulations must be observed. 8/14

Connection terminals and operator controls RXA21.1 00601 a 1 2 3 4 5 6 7 8 9 10 11 12 13 O DIP B1 M X2 D1 T T 0...10 V AC 230 V D D2 D3 Y2 M Q13 Q14 Y3 M 5(4) A Q24 Y4 Q34 1 2 3 4 5 6 7 8 9101112 S1...12 QAX... 2 1 R1 M/S CP- CP+ 19 19 21 21 25 26 27 28 14 15 16 Measured value inputs B1 1 Measured value input for &S i 1000 sensor or setpoint adjuster M 2 Measured value input ground X2 3 Configurable input for &S i 1000 sensor, setpoint adjuster or 0 10 V signals Signal inputs D1 4 Signal input (window or clock) D 5 Signal ground D2 6 Signal input (occupancy) D3 7 Changeover input Triac outputs 8 AC 24 V, 0.5 A switching output 9 AC 24 V actuator supply Y2 10 AC 24 V, 0.5 A switching output Y3 11 AC 24 V, 0.5 A switching output 12 AC 24 V actuator supply Y4 13 AC 24 V, 0.5 A switching output Device bus M/S 14 Master/slave connection CP 15 round for PPS2 and M/S CP+ 16 PPS2 (room unit) Power supply 19 eutral conductor 21 Phase conductor AC 230 V +/- 10 % Relay outputs Q13 25 Shared contact for Q14, Q24 and Q34 Q14 26 ormally-open contact, max. AC 250 V, 5 (4) A (Stage 1) Q24 27 ormally-open contact, max. AC 250 V, 5 (4) A (Stage 2) Q34 28 ormally-open contact, max. AC 250 V, 5 (4) A (Stage 3) Operator controls S1...12 DIP switch for configuring the room controller. R1 Potentiometer for setpoint reset and test purposes. STOP Caution Observe the technical data for the relay outputs: max. AC 250 V, 5 (4) A Important ocal installation regulations must be observed. 9/14

Connection terminals and operator controls RXA22.1 00602 a 1 2 3 4 5 6 7 8 9 10 11 12 13 O DIP B1 M X2 D1 D D2 D3 Y2 1 2 3 4 5 6 7 8 910 S1...10 T T 0...10 V AC 230 V 10 A 5(4) A QAX... 2 1 R1 Q13 Q14 Q24 Q34 M/S CP- CP+ Q43 Q44 19 19 21 21 22 23 24 25 26 27 28 14 15 16 Measured value inputs B1 1 Measured value input for &S i 1000 sensor or setpoint adjuster M 2 Measured value input ground X2 3 Configurable input for &S i 1000 sensor, setpoint adjuster or 0 10 V signals Signal inputs D1 4 Signal input (window or clock) D 5 Signal ground D2 6 Signal input (occupancy) D3 7 Changeover input Triac outputs 8 AC 24 V, 0.5 A switching output 9 AC 24 V actuator supply Y2 10 AC 24 V, 0.5 A switching output Device bus M/S 14 Master/slave connection CP 15 round for PPS2 and M/S CP+ 16 PPS2 (room unit) Power supply 19 eutral conductor 21 Phase conductor AC 230 V +/- 10 % Relay outputs Q13 25 Shared contact for Q14, Q24 and Q34 Q14 26 ormally-open contact, max. AC 250 V, 5 (4) A (Stage 1) Q24 27 ormally-open contact, max. AC 250 V, 5 (4) A (Stage 2) Q34 28 ormally-open contact, max. AC 250 V, 5 (4) A (Stage 3) Q43 22, 23 ead wire for Q44 Q44 21 /O contact AC max. 250 V, 10 A...(electric heating coil) Operator controls S1...10 DIP switch for configuring the room controller. R1 Potentiometer for setpoint reset and test purposes. STOP Caution Observe the technical data for the relay outputs: max. AC 250 V, 5 (4) A or 10 A ocal installation regulations must be observed. 10/14

Connection diagrams Connecting the field devices, room units and supply voltage 1 00603 B1 1 T B1 B1.1 M 2 X2 3 T B2 B2.1 0...10 V X2.2 D1 D D2 4 5 6 D1 D2 D3 7 D3 Y2 8 9 10 Y2 M.1 Y3 Y4 11 12 13 M Y3.1 M Y3.2 M/S CP CP+ 14 15 16 PPS2 B3 14 15 RXA 2...4 19 19 21 21 AC 230 V Q13 Q14 Q24 Q34 25 26 27 28 1 2 3 Q2 1 Q1 Q43 Q44 22 23 24 Q4 F1 1 RXA20.1, RXA21.1, RXA22.1 2...4 Max. 3 slave controllers B1, B2 &S i 1000 temperature sensor B1.1, B2.1 Setpoint adjuster X2.2 0 10 V signal (summer/winter compensation) B3 QAX3 room unit D1, D2 Volt-free contacts (window contact, occupancy sensor, central time switch etc.) D3 Changeover signal, Y2 AC 24 V thermic valve actuators.1, Y3.1 Valve actuator, AC 24 V, 3-position (RXA21.1 only) Y3.2 Damper actuator with spring return Q1 Single-speed fan Q2 3-speed fan Q4 Electric heating coil F1 External fuse Twisted pair 11/14

STOP Caution Fans connected to relay outputs Q14 Q34 must not be operated in parallel. For parallel operation use cut-off relays or slave controllers. At Q4 (max. resistive load 1.8 kw), use additional external fuses of max. 10 A to protect the pcb tracks. ote For information on the compatibility of the various field devices with the RXA20.1, RXA21.1 and RXA22.1 room controllers, refer to the relevant application description. Connecting a power amplifier Parallel connection of a number of thermic valve actuators to output using the UA1T power amplifier. The same principle applies to outputs Y2 Y4. ote that the simultaneous load on outputs Y4 must not exceed 9.5 VA (power consumption at input X1 of the UA1T: 0.5 VA) AC 24 V 0 70206 1 6 7 2 1 2 S S COM 8 7.1 3 4 COM X1 COM 6 5.1 2 1 2 S S COM 8 7.1 3 4 COM X1 COM 6 5.1 1 RXA20.1, RXA21.1, RXA22.1 2 UA1T (see data sheet CA23591) AC 24 V thermic valve actuator.1 AC 24 V thermic valve actuator (max. 2 STE72 actuators per output on the UA1T) otes The UA1T requires an AC 24 V supply voltage The UA1T is not suitable for the connection of 3-position actuators. 12/14

Dimensions Without terminal covers Dimensions in mm 35,3 3,9 62 1 3,3 133,2 1,5 00611 With terminal covers 51,5 40,8 12 70210 35,3 167 62 1 3,9 112,4 107,8 Drilling diagram 00612 3,8 39 78 43,2 86,3 13/14

14/14 2001 Siemens Building Technologies A Subject to technical alterations