Options Standard WiFi PM+ PM+/WiFi GPRS PM+/GPRS Meter

Similar documents
Options Standard BT WiFi BT/WiFi PM+ PM+/WiFi GPRS PM+/GPRS Meter

Options Standard PM+

Solar-Log Hardware. Highlights of the new Solar-Log devices

Managing PV Plants in the Medium Voltage Network

Meter Connection Manual V Solar-Log

Installation manual. Solar-Log

User Manual V Solar-Log

Release Notes (Solar-Log Build 106, July 3, 2018)

PV Grid Connected. PRIce LIST valid from 1st Januar 2014 by Steca

Manual V G. Solar-Log

Installation manual V Solar-Log

Solar-Log WEB Enerest Home. User Manual V1.0

/ Battery Charging Systems / Welding Technology / Solar Electronics. / Configuration guide

Solar-Log WEB "Classic 2nd Edition" Manual Installation

Manual V Solar-Log 50

Customized for tomorrow today.

Release Notes (Solar-Log WEB Enerest 3.4.0, )

User Manual SMA CLUSTER CONTROLLER

SMART HOME and REACT Your energy breaks free

Device for Power Control in PV Plants POWER REDUCER BOX

User Manual SUNNY HOME MANAGER in SUNNY PORTAL

Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range

Solar-Log WEB Commercial Edition Product information

User Manual SMA CLUSTER CONTROLLER

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted

Fronius International GmbH Froniusplatz Wels FRONIUS PRIMO THE COMMUNICATIVE INVERTER FOR OPTIMISED ENERGY MANAGEMENT

Release Notes (Solar-Log Build 87, )

Communicative. Adaptable. System and yield monitoring with SOLPLUS+ and SOLVOLT. Communicating with SOLPLUS Inverters

Photovoltaik ON GRID / OFF GRID

Utility scale PV Monitoring Solutions

User Manual SMA CLUSTER CONTROLLER

How to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet

Commercial Solar SCADA, Support Multi-Brand Solar Inverters Energy Management and Demonstration Platform

EC-BOS-8 Multi-protocol Web Building Controller

FusionSolar. Residential Smart PV Solution. FusionSolar

Make the sun your energy source. SOLAR

KS 108 easy Compact automation unit for industrial control and process technology

Reliable Monitoring Data for PV plants

THE RAINBOW SCADA D-700

Release Notes (Solar-Log Build 111, )

POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security. Business, Opportunities and Risks

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

Monitoring Box IMA-BOX

About Huawei. A Global Leader of ICT Solutions

EC-BOS-8 Multi-protocol Web Building Controller

Fronius DATCOM. The data communication system for PV system monitoring

Sigma Solar Server. Our systems and solutions for photovoltaic power plants

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

KS 108 easy Compact automation unit for industrial control and process technology

PRODUCTS AND SERVICES. At a glance

Contents. 1. About this Manual Scope of Application Target Reader Abbreviations Introduction...

Inverter and web server in one unit

Fronius Solar Electronics - product overview

HEMS 2000 Home Energy Management System

User Manual Webconnect Systems in SUNNY PORTAL

8 Troubleshooting. 8.1 Forgotten Password

BLUE LOG XM / XC. Quick Start Guide. Version

Infinisolar V Hybrid-On Grid Inverter with Energy Storage

Webdom Datalogger 1.5

Smarter Energy for a Better Life. Huawei FusionHome Smart Energy Solution. For End Users

Power System Network Simulator (PSNsim)

PV System Monitoring for the FRONIUS IG Inverter Series

Solarfox Online Management

PHS 1601 Point Heating Control. voestalpine SIGNALINGSainerholz GmbH

PHOTOVOLTAIC SOLUTIONS. Operating Instructions. Data logger for photovoltaic plants. RPSlog1000

BLUE LOG X-SERIES. Quick Start Guide. Version

OMNICOMM ON-BOARD TERMINALS

Infrastructure management service

Connection and settings to enable the Off-Grid function. Sungrow EPS unit on a single phase

SICAM DC - A new Generation of Smart Meter Data Concentrator Answers for infrastructure and cities.

with Backlight Graphic LCD Screen

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Monitoring and Controlling Energy Efficiency of Photovoltaic Installations

AEconversion. Micro-Inverter System Monitoring Control System - CO3 Storage System. AEconversion GmbH & Co. KG

A platform to build smart solutions for everyday ease

SMART CAMPUS Experiencias de eficiencia energética en la UMU Miguel Ángel Zamora

Smart Metering Monitoring and Control

Smart-UPS On-Line. 2 nd Generation 3-10 kva Offer Technical Overview

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

Installation Manual SMA CLUSTER CONTROLLER

Perfection Plus. Usability.

StorEdge Wiring Guide & On Site Checklist for North America

DS 500 Intelligent chart recorder for compressed air and gases

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

Release Notes (Solar-Log Build 97, December 18, 2018)

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Comissioning Assistant - Update. Version

Solar-Log. by Solare Datensysteme GmbH

ennexos Operating manual SMA DATA MANAGER M with SUNNY PORTAL powered by ennexos EDMM-10-BE-en-14 Version 1.4 DATA MANAGER V Digital Input

Color Control GX Firmware version v1.11

INSTALLATION AND COMMISSIONING CHECKLIST

Online data sheet. Flow-X FLOW COMPUTER

String monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems

WattmonMEGA Remote Monitoring & Control Platform

Ammonit Meteo-40 Data Logger

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

Improving Remote Site Communications Using Wireless Technologies. Eric Swanson

THE RAINBOW SCADA D-500-LITE

Transcription:

Years Maximum plant size 2000 kwp Optional Powermanagement and cos phi control Color TFT-Touch-Display and LCD- Status-Display for displaying graphics and operation Monitor central inverters and SCBs Options Standard WiFi PM+ PM+/WiFi GPRS PM+/GPRS Meter - - - Article number 255592-255594 - 255593 255595-2 1

Solar-Log 2000 For solar power stations and large-scale PV plants Functions Self-consumption The Solar-Log 2000 offers the option to measure the amount of self-produced power consumed and to present it graphically via the Solar-Log WEB Commercial Edition. An additional power meter serves as a consumption meter. Solar-Log 2000 alarm function This provides your plant with anti-theft protection and an external alarm against burglars and vandals. Display Options TFT-Touch-Display and access to Solar-Log The Solar-Log can be operated from a computer with a web browser or directly via the device s TFT-Touch-Display. The graphical reports of yield data are visualized on the color TFT-Touch-Display and via the web browser. Remote access is possible with the Solar-Log WEB Commercial Edition. Connections Inverters Number of inverters / devices just one manufacturer per bus, total maximum 100 inverter / devices, maximum plant size 2000 kwp. Interfaces The interfaces can be used to connect inverters (up to two different manufacturers) and accessories such as Utility Meter, Pyranometer and SCBs. The Solar-Log 2000 Standard and Solar-Log 2000 PM+ have two RS485/RS422 interfaces and one RS485 interface. The Solar-Log 2000 GPRS and Solar-Log 2000 PM+/GPRS have one RS485/RS422 and one RS485 interface. 2

Options Solar-Log 2000 PM+ & Solar-Log Utility Meter Combining the Solar-Log 2000 and Utility Meter simplifies implementation of the diverse requirements for powermanagement in Germany. The voltage-dependent reactive power control, Q(U) function, is accomplished by measuring the medium voltage with the Utility Meter. The combination of the Solar-Log 2000 and Utility Meter is also needed to send a confirmation of the current amount of feed-in power to the grid operator. Solar-Log 2000 & PM-Package For plants larger than 100 kwp, remote control of the reactive power supply and power limitations are required along with a confirmation of the current amount of feed-in power. In practice, each grid operator stipulates its own signalization variant in the technical connection requirements (TAB). To fulfill the requirements from a particular grid operator, Solare Datensysteme offers a grid company specific PM-Package. This package includes hardware that is adjusted to a company s remote control technology and profile file. String Connection Box (SCB) or String Monitoring Box (SMB) When used with the Solar-Log WEB Commercial Edition and either the SCB or SMB, the Solar-Log 2000 monitors every single string, ensuring the most complete and secure monitoring for large-scale PV plants with exact error identification and localization. Feed-in management - feed balance: The times when there was a grid feed and when electricity was purchased from the grid can be seen at a glance in this graph. Negative values indicate that electricity was purchased from the grid and positive values that there was grid feed. 4 3

Solar-Log 300, 1200 and 2000 Common features Functions Local monitoring Local graphical reports via web browser. LCD-Status-Display Status display for installation and operations. Smart Energy Recording and presentation of self-consumption control and visualization of individual appliances for the optimization of self-consumption. Feed-in management Reduction of feed-in power with a dynamic allowance for self-consumption. Display Options Solar-Log WEB The Solar-Log WEB Commercial Edition online portal expands the presentation and monitoring functions of the Solar-Log and offers comprehensive reporting options in the form of graphs and tables via the Internet. Solar-Log APP You can access your data and graphical reports at any time from anywhere in the world with the free Solar-Log APP. Solar-Log Dashboard The Dashboard is a feature of the WEB Commercial Edition that displays all important information for a plant such as yields, CO 2 savings and plant performance. Solarfox large and external display A large external display used in combination with the Solar-Log can visually present live data from a PV plant. You can also add personalized advertisements. Large external displays can be connected via the RS485 or S 0 interface. 4 5

Connections Inverters The Solar-Log is compatible with inverters from all major manufacturers. Sensors RS485 The sensors measure solar irradiation, temperature and wind speed. They can even be combined with some inverters on an RS485 bus. Meter S 0 -In or RS485 The meter can record your consumption data or serve as an inverter and measure the power from incompatible inverters. In addition, batteries can be visualized via meters. RS485 or S 0 -Out Connect a large external display to gain an additional overview of the data. Solar-Log 300 USB connection and data export A USB stick can be connected to manually install new firmwares with new functions or to transfer backups and other data. Ripple Control Receiver The signal to reduce active power is generally sent via a Ripple Control Receiver or remote control technology. Up to two Ripple Control Receivers can be connected to the Solar-Log PM+, one for power reduction and one for reactive power control. Ethernet / Speedwire* The Solar-Log models can be connected to compatible inverters with an Ethernet connection. SMA inverters can be connected directly to a regular network infrastructure with SMA s own Speedwire protocol. The SMA inverter only has to be connected to an Ethernet switch or router. Additional Functions Cable cover With its attractive design the cable cover for the Solar-Log offers the best possible mechanical protection for interfaces and cables. Data security The data volume from the Solar-Log can record for up to 20 years. The micro SD card is used to protect against any loss of data in the event of a power failure. Solare Datensysteme GmbH info@solar-log.com www.solar-log.com 6 Subject to change without notice! EN 06.2015 Version 1.3 *In many countries, the designation Speedwire is a registered trademark of SMA Solar Technology AG.