MTS-2000 USER S MANUAL

Similar documents
87421/22A Power Supply. Operating and Service Manual

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

Automated Tuner System Power Distribution Hub

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

User's Guide. Extech AM A AC Analog Clamp Meter

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

WARRANTY & LIMITATION OF LIABILITY

S82S (3/7.5-W Models)

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

WARRANTY & LIMITATION OF LIABILITY

PIM-Mini Pulsed Current Source Operation Manual

Model Number Structure

Zonit μats TM Users Guide μats1-lv Version 1.2

FTC-200 X-ray Tube Controller Users Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

iconverter 2-Module Power Chassis

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Thermocouple Input Module

User s Guide. 600A AC Clamp Meter. Model 38387

ACLD Channel Opto-isolated Digital Input Board

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

INSTRUCTION and OPERATIONS MANUAL. for

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

INTMOD485-LH Protocol Converter

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Relay Board. User Manual. 1.0, Oct 2013

Power Analyzer Datalogger Model

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

PCM-7140 Pulsed Current Source Operation Manual

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Model E100RC. DC Millivolt Reference Source ±1µV to ±10Vdc - 10ppm Resolution. Operating Manual

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Vocia ELD-1. Operation Manual

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Model VT120 Fast Timing Preamplifier Operating and Service Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

User's Guide. Model High Precision Quad Output DC Power Supply

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

DC-AC Inverter Pure Sine Wave 120 Watt. Please read this manual before installing your Inverter. Manual PST

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

SCIENCEWORKSHOP 750 INTERFACE. Instruction Sheet for the PASCO Model CI Introduction

B Polling Interface

DRTS 33. The new generation of advanced three phase relay test set

Model Number Structure

Sonic Ruptor 400. User Manual

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top)

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model A Mini AC/DC Clamp Meter. User's Guide

USER'S MANUAL DCL-650

V-9908 MESSAGE/PAGE PANEL

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Mini Digital Multimeter

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

HA-10 Vacuum Tube Headphone Amp

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Solid State Relays with Failure Detection Function

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Model Number Structure

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

MTP INSTRUCTION MANUAL

OP8662 High Voltage and Current Probe User Guide.

Compact USB Digital Speakers. Quick Start User Guide

Photoelectric Sensor

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Transcription:

MTS-2000 USER S MANUAL

USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this manual! CU R001 01B MANTA TEST SYSTEMS 1

MTS-2000 User s Manual All rights reserved by Manta Test Systems Inc. No part of this publication may be reproduced or distributed in any form or by any means without the permission of Manta Test Systems Inc. The information and specifications contained within from Manta Test Systems are believed to be accurate and reliable at the time of printing. However, because of the nature of this product, specifications and features shown in this manual are subject to change without notice. The features and capabilities described herein reflect those available in MTS-2000 firmware release 1.00. March 2010 Document ID# CUR 001 01B MANTA TEST SYSTEMS 4060B Sladeview Crescent, Unit 1 Mississauga, Ontario L5L 5Y5, Canada Tel: 905-828-6469 Fax: 905-828-6850 Internet: http://www.mantatest.com e-mail support@mantatest.com Toll-free technical support (USA & Canada): 1-800-233-8031 2 MANTA TEST SYSTEMS CU R001 01B

MTS-2000 User s Manual Table of Contents 1. PRODUCT OVERVIEW 4 2. TECHNICAL SUPPORT 5 SAFETY CONSIDERATIONS 5 LIMITED PRODUCT WARRANTIES 6 4.1 Hardware 6 4.2 Software & Firmware 6 4.3 Separate Extended Warranty for Hardware Products 6 4.4 Exclusion of other Warranties 6 4.5 Limitation of Liability and Remedies 7 4.6 Limitation of Warranty Regarding Software 7 4.7 Extension of Warranty 7 5. PRIMARY MODULES 8 5.1 Front Panel 8 5.2 Display 8 5.3 RS-232 Communications 8 5.4 DC Current Loop Output 8 5.5 DC Current Loop Input 8 5.6 Channels 8 5.7 Power supply 8 6. SPECIFICATIONS 9 6.1 Inputs 9 6.2 Outputs 9 6.2 Outputs (Cont d) 10 6.3 Data Interfaces 11 6.4 Accessories 11 6.5 Physical Characteristics 11 7. USER INTERFACE CHARACTERISTICS 12 8. OPERATING MODES 14 8.1 Manual Test Mode 14 8.2 Meter Test Mode 14 8.3 Setup Mode 15 9. EXAMPLE CONNECTION DIAGRAMS 16 9.1 Testing an Ammeter 16 9.2 Testing a Voltmeter with Channel 1 16 9.3 Testing a Voltmeter with Channel 2 17 9.4 Testing a Wattmeter 17 9.5 Testing a Current Transducer 18 9.6 Testing a Voltage Transducer with Channel 1 18 9.7 Testing a Voltage Transducer with Channel 2 19 9.8 Testing a Watt Transducer 19 9.9 Testing a Voltage Device (0 300V) 20 9.10 Outputting Transducer Current (0-20mA) 20 9.11 Outputting DC Current (0 2500 ma DC) 20 CU R001 01B MANTA TEST SYSTEMS 3

1. PRODUCT OVERVIEW The MTS-2000 is a meter test system designed to test panel meters, transducers and similar metering hardware. All applicable quantities (voltage, current, power, frequency, phase, etc) are displayed as required. The MTS-2000 is designed to be easily operated from the controls on the front panel. The system displays output values, operating modes, etc. The user interface makes use of a bank machine type menu system that can be navigated with softkeys on the instrument. All current and voltage inputs and outputs use standard banana jacks. The MTS-2000 can also be operated by remote control from an external computer. FEATURES: 1. 4x20 Character Display 2. Front Panel Membrane with Bank Machine Style Soft-key Interface 6. Front Panel On/Off Switch and 120Vac Input 7. One RS-232 Port 3. Keypad for Data Entry 8. Cable Storage in Lid 4. 0-150V AC/DC Voltage Output Channel 5. Convertible Voltage (0-150V AC or DC) or Current (0-5Aac, 0-2.5Adc) Output Channel 9. 0-20mA Analog Input 10. 0-20mA Analog Output Boot Time < 5 Seconds 6 4 8 9/10 5 1 7 2/3 4 MANTA TEST SYSTEMS CU R001 01B

2. TECHNICAL SUPPORT Our technical support team is committed to working with you, our customers, to ensure that you have the products which best serve your specific needs. The design of this instrument reflects decades of experience in the electric power industry. Manta Test Systems recognizes, however, that there will be testing situations encountered which were not considered during product design. Manta Test Systems encourages any user questions, problems or suggestions to be forwarded to us, via the representative through whom the product was purchased, or directly to us via the fax numbers provided on the front cover or in the customer support area of our website. 3. SAFETY CONSIDERATIONS This instrument can generate high levels of current and voltage. Incorrect usage may cause personal injury or damage to the instrument. The user must be qualified to work safely in the intended application environment of this instrument. Non-adherence to the following minimum requirements constitutes misuse of the MTS-2000, and the manufacturer accepts no liability for damages arising from such misuse: 1) The instrument case must always be effectively grounded. The integrity of the power supply cord ground should always be verified before use. 2) All leads and connectors should be in good condition and rated for the appropriate voltage and current carrying requirements. 3) The outputs must not be connected to live outputs or live equipment. 4) All outputs must be turned off before making changes in connections. 5) Note: the black (return) terminals of Channel 1 and 2 are internally connected. CU R001 01B MANTA TEST SYSTEMS 5

4. LIMITED PRODUCT WARRANTIES 4.1 Hardware Manta Test Systems warrants that its hardware products, and the hardware components of its products, shall be free from defects in materials and workmanship under normal use and service for a period of one year from the date such products are shipped from Manta Test Systems. Provided that Manta Test Systems receives notice of any defects in materials or workmanship of its hardware products, or hardware components of its products, within a one-year period, Manta shall, at its option, either repair or replace the defective hardware product or hardware component, if proven to be defective. 4.2 Software & Firmware Manta Test Systems warrants that its software products, and the software and firmware components of its products, shall not fail to execute their programming instructions under normal use and service, due to defects in materials and workmanship, if properly installed on intended hardware, for a period of one year from the date such products are shipped from Manta Test Systems. Provided Manta Test Systems receives notice of such defects within the warranty period, it shall, at its option, either repair or replace the software or firmware media, if proven to be defective. 4.3 Separate Extended Warranty for Hardware Products Aside from the standard warranty set forth above, Manta Test Systems offers a separate extended warranty plan for all hardware products (excluding cables, batteries and accessories) which may be purchased, and extends the standard warranty by one additional year. The extended warranty is issued under the same terms, conditions and exclusions as the standard warranty set forth herein. Pricing is based upon the cost of the product, and the average cost of servicing and calibration. Refer to the Manta Test Systems price list available from your local representative, or Manta Test Systems, for extended warranty pricing for specific products. The extended warranty must be purchased and paid for within three months from the date the product is shipped from Manta Test Systems. 4.4 Exclusion of other Warranties THE FOREGOING WARRANTIES ARE EXCLUSIVE, AND ARE IN LIEU OF ANY AND ALL OTHER WARRANTIES (WHETHER WRITTEN, ORAL OR IMPLIED) INCLUDING, BUT NOT LIMITED TO, WARRANTY OF MERCHANTABILITY IN OTHER RESPECTS THAN AS SET FORTH ABOVE, AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 6 MANTA TEST SYSTEMS CU R001 01B

4.5 Limitation of Liability and Remedies IT IS UNDERSTOOD AND AGREED THAT MANTA TEST SYSTEMS LIABILITY AND PURCHASER S SOLE REMEDY, WHETHER IN CONTRACT, UNDER ANY WARRANTY, IN TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE, SHALL NOT EXCEED THE COST OF REPAIR OR REPLACEMENT OF MANTA TEST SYSTEMS PRODUCTS, AS SET FORTH ABOVE, AND, UNDER NO CIRCUMSTANCES, SHALL MANTA TEST SYSTEMS BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, PERSONAL INJURY, PROPERTY DAMAGE, DAMAGE TO OR LOSS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS OF RENTING REPLACEMENTS, AND OTHER ADDITIONAL EXPENSES. FURTHERMORE, IT IS UNDERSTOOD AND AGREED THAT MANTA TEST SYSTEMS SHALL NOT BE LIABLE FOR ANY DAMAGES, LOSSES OR EXPENSES AS A RESULT OF THE PURCHASER S OR ANYONE ELSE S: I. NEGLIGENCE (WHETHER DEEMED ACTIVE OR PASSIVE), II. MISUSE, ABUSE, OR MODIFICATION OF MANTA TEST SYSTEMS PRODUCTS, III. USE OR OPERATION OF PRODUCTS NOT IN CONFORMITY WITH THE SPECIFICATIONS AND INSTRUCTIONS FURNISHED BY MANTA TEST SYSTEMS FOR ITS PRODUCTS, IV. REPAIR OR MAINTENANCE OF MANTA TEST SYSTEMS PRODUCTS BY PERSONS OR ENTITIES NOT AUTHORIZED BY MANTA TEST SYSTEMS, OR V. DAMAGE TO, OR DESTRUCTION OF, PRODUCTS, DURING DELIVERY TO MANTA TEST SYSTEMS FOR ANY REASON. 4.6 Limitation of Warranty Regarding Software Manta Test Systems does not warrant that the operation of the software, firmware or hardware shall be uninterrupted or error free. 4.7 Extension of Warranty At the discretion of Manta Test Systems, the warranty may be extended for a product which has been returned for service shortly after its warranty period has expired. CU R001 01B MANTA TEST SYSTEMS 7

5. PRIMARY MODULES 5.1 Front Panel The bank machine style user interface makes use of soft-keys that are selected by pressing the button adjacent to the description. A keypad is used for direct entry of numeric values. 5.2 Display The system uses a 4x20 character vacuum florescent display device to display output values, operating modes, etc. 5.3 RS-232 Communications An RS-232 port is provided to allow control of the instrument using a PC and to facilitate software upgrades. 5.4 DC Current Loop Output A 0mA to 20mA output is provided for testing current loops normally driven by a transducer. 5.5 DC Current Loop Input A 20mA to +20mA input is provided to measure a transducer s output. 5.6 Channels The system houses two independent power output channels. One channel operates in voltage mode only, and can generate up to 150V (AC or DC). The other channel can generate voltage or current. In voltage mode it generates up to 150V (AC or DC). In current mode it generates up to 5Aac or up to ±2.5Adc. 5.7 Power supply The mains input is auto-ranging, power factor corrected and can operate from either 105-130 or 208-250Vac (50-60Hz). 8 MANTA TEST SYSTEMS CU R001 01B

6. SPECIFICATIONS NOTE: Due to techinical progress, specifications are subject to change without notice. All AC quantities are RMS values, except as otherwise noted. Power outputs are specified for nominal 120VAC/60Hz or 240VAC/50Hz power input, and 25 C ambient operating temperature. Derating applies for lower input power voltages and higher ambient temperatures. For all current outputs, maximum obtainable current will vary inversely with load impedance. For extended operation at high power output levels, ensure adequate cooling (i.e. verify air intakes and exhaust ports are unrestricted). 6.1 Inputs Mains Supply Single phase 105-130VAC (or 208-250VAC) @400VA max, 47-63 Hz, auto-ranging Transducer Input Measures low level output from AC transducers Maximum input level: ±20mA DC Measurement accuracy: 0.04% reading + 0.01% range (25±5 C) after 10min warmup (for waveforms under 2% THD ) Connector: 4mm Banana 6.2 Outputs Transducer Output Generates low level output for AC transducer inputs Maximum output level: 0-20mA DC Setting accuracy: 0.04% setting + 0.01% range (25±5 C) after 10min warmup Compliance: >=10Vdc, ( >=11Vdc typical ) Max Load: 10kΩ (to 1mA), 2kΩ (to 4mA), 1kΩ (to 10mA), 500Ω (to 20mA Connector: 4mm Banana Voltage 2 AC or DC voltage channels 0-150V (AC or DC) per channel in independent mode 0-300V (AC or DC) when channels are connected in series Setting resolution: 0.01Vrms, 0.1Vdc Accuracy greater of: 0.25% of setting or 0.03 Vrms (10Hz-400Hz, DC) 1.0% of setting (400Hz-800Hz), greater than 1% of range Power AC: 30VA max per channel, 60VA min with 2 channels in series,60hz. Power DC: 15W dc max per channel, 30W dc with 2 channels in series Noise & distortion at maximum power: <1% Bandwidth: 3kHz (-3dB) Protection: Overload, short circuit, over-temperature, transient overvoltage, clip indication Surge Current (DC mode): 1A maximum (limited) Connector: 4mm Banana CU R001 01B MANTA TEST SYSTEMS 9

6.2 Outputs (Cont d) Current 1 AC or DC current channel 0-5Arms, or 0-2.5Adc, direct coupled Setting resolution: 0.001Arms Accuracy greater of: 0.25% of setting or 0.01 Arms (10Hz-400Hz,DC) 1% (400Hz-1000Hz) Power: 50 VA maximum, 30W dc Noise & distortion at maximum power: <1% Bandwidth: 3kHz (-3dB) Protection: Overload, short circuit, over-temperature, transient overvoltage, clip indication Connector: 4mm Banana Compliance & Loading: (60Hz) AC Outputs Frequency/Phase Angle Frequency range: DC, 10-1000 Hz Frequency resolution: 0.001Hz Frequency accuracy: 50ppm Capable of generating 2 simultaneous frequencies Phase angle range: 0-359.9, resolution 0.1 Phase accuracy: 0.1 (43-65Hz), 0.5 (10-43Hz and 65-120Hz), 1.0 (120Hz-1000Hz) 10 MANTA TEST SYSTEMS CU R001 01B

6.3 Data Interfaces All interfaces are fully isolated from AC/DC inputs and outputs. Ground, where present, is connected to frame ground. RS-232 Serial Port Standard 9 pin male DB-9 wired as DTE (Data Terminal Equipment) 9600 to 115,200 baud 6.4 Accessories User s manual AC power cord Test lead kit and detachable storage pouch RS-232 null modem cable optional 6.5 Physical Characteristics 14.9 W x 6.9 H x 12.1 D (37.9cm W x 17.5cm H x 30.8cm D) Weight: 15 lbs (6.8 kg) Display: 20 character by 4 line VFD Operating temperature: 32 to 122 F (0 to 50 C) Storage temperature: -13 to 158 F (-25 to 70 C) CU R001 01B MANTA TEST SYSTEMS 11

7. USER INTERFACE CHARACTERISTICS Hardware related to the front-panel user interface includes: A B C D E F G H 4 line, 20 character-per-line display 8 function keys, positioned to the left and right of each line on the display device MENU key ENTER key CE (clear entry) key 0-9 digit keys decimal point key +/- key B A E H C F G D L I J K L OUTPUTS ON key OUTPUTS OFF key LEDs: OUTPUTS ENABLED VOLTAGE MODE (2nd Channel) I K J 12 MANTA TEST SYSTEMS CU R001 01B

When the device is powered on, the manual test mode screen described later in this document is shown. To change modes or exit menus, press MENU: Pressing the function key adjacent to a label ( Manual Test, etc.) causes the screen described by that key s label to appear. Pressing the MENU key at any time will always return you to the previous place in the menu tree. Many screens contain editable values. For example, the following screen contains four editable values: 1.000, 1.000, 5.000, 5.000 Pressing the function key next to an editable value selects that value, highlighting it in inverse text on the display. If you type a numeric key, an editing screen appears similar to this one: The editing display shows the name of the setting being edited and its allowable range. As you type in the digits, you can change the sign or enter a decimal point. Changes are reflected between the square brackets. When finished entering a number, you may press ENTER to store it or CE to abort entry. The OUTPUTS ON and OUTPUTS OFF keys turn the two channels on or off. Whenever the amplifier outputs are on, the ENABLED LED is on. Some tests configure channel 2 to output current, others configure it to outpt voltage. The VOLTAGE MODE LED is on when the convertible amplifier is configured to output voltage. CU R001 01B MANTA TEST SYSTEMS 13

8. OPERATING MODES The MTS-2000 offers various operating modes that are designed to provide an easy to use interface for the particular category of testing to be performed. The basic modes are: 1. Manual test 2. Meter test 3. Transducer test 4. Setup 8.1 Manual Test Mode The manual test mode is used for basic meter and transducer testing. It consists of a single screen, allowing you to set voltage, current, frequency and phase angle, and displays the current loop input current. The amplifiers are configured so that channel 1 generates voltage and channel 2 generates current. The voltage and current values entered by the user are generated as displayed, with no conversion or scaling. When the device is powered on, the manual test mode screen is shown. From the main menu, the Manual Test function key returns to the manual test screen, shown below. In this mode, you may adjust the voltage, current, frequency and phase angle, and use the OUTPUTS ON and OUTPUTS OFF keys to turn the channels ON or OFF. The 0-20mA current input is shown so the user can test transducers with current outputs. 8.2 Meter Test Mode The Test a Meter function key in the main menu presents the user with a menu listing of available meter-specific test screens: 14 MANTA TEST SYSTEMS CU R001 01B

Each selection presents a series of screens to configure the test, including: Minimum and full-scale limits (V, A, W, etc.) CT and PT ratios Connections screen describes the channel wiring required for the specific mode, and the test screen allows the user to adjust the output levels and see the expected value on the meter. For example, when the Volts function key is pressed, the following screens appear in sequence: Pressing the CONFIG function key returns to the full scale / min scale screen. The meter-specific test modes include a QUICK SET function key. Pressing it repeatedly causes the appropriate values to be generated so that the meter will read 0%, 25%, 50%, 75% and 100% of full scale. 8.3 Setup Mode The Setup selection in the main menu allows the user to configure the device, including: * Calibrate the amplifiers * Calibrate the current loop input and output CU R001 01B MANTA TEST SYSTEMS 15

9. EXAMPLE CONNECTION DIAGRAMS 9.1 Testing an Ammeter 9.2 Testing a Voltmeter with Channel 1 16 MANTA TEST SYSTEMS CU R001 01B

9.3 Testing a Voltmeter with Channel 2 9.4 Testing a Wattmeter CU R001 01B MANTA TEST SYSTEMS 17

9.5 Testing a Current Transducer 9.6 Testing a Voltage Transducer with Channel 1 18 MANTA TEST SYSTEMS CU R001 01B

9.7 Testing a Voltage Transducer with Channel 2 9.8 Testing a Watt Transducer CU R001 01B MANTA TEST SYSTEMS 19

9.9 Testing a Voltage Device (0 300V) 9.10 Outputting Transducer Current (0-20mA) 9.11 Outputting DC Current (0 2500 ma DC) (note: Channel 2 must be set to DC) 20 MANTA TEST SYSTEMS CU R001 01B

Manta Test Systems Inc. ISO 9001 Registered www.mantatest.com 4060B Sladeview Crescent, #1, Mississauga, ON L5L 5Y5, Canada e-mail: sales@mantatest.com Phone: 905-828-6469 Toll Free: 800-233-8031 Fax: 905-828-6850 CU R001 01B