XI Conference "Medical Informatics & Technologies" VALIDITY OF MRI BRAIN PERFUSION IMAGING METHOD

Similar documents
n o r d i c B r a i n E x Tutorial DSC Module

REGISTRATION AND NORMALIZATION OF MRI/PET IMAGES 1. INTRODUCTION

Supplementary Figure 1

Advanced MRI Techniques (and Applications)

A Spatio-temporal Denoising Approach based on Total Variation Regularization for Arterial Spin Labeling

Brain Perfusion Imaging - Performance and Accuracy

Correction of Partial Volume Effects in Arterial Spin Labeling MRI

Perfusion quantification by model-free arterial spin labeling using nonlinear stochastic regularization deconvolution.

Automated Method for Generating the Arterial Input Function on Perfusion-Weighted MR Imaging: Validation in Patients with Stroke

Perfusion MRI: Non-Linear Stochastic Regularization for Deconvolution of Model-Free Arterial Spin Labelling Data

DeepASL: Kinetic Model Incorporated Loss for Denoising Arterial Spin Labeled MRI via Deep Residual Learning

Original Research. Anne M. Smith, PhD,* Cécile B. Grandin, MD, Thierry Duprez, MD, Frédéric Mataigne, MD, and Guy Cosnard, PhD

Guillaume Duhamel, 1 Gottfried Schlaug, 2 and David C. Alsop 1 *

DeepASL: Kinetic Model Incorporated Loss for Denoising Arterial Spin Labeled MRI via Deep Residual Learning

MB-EPI PCASL. Release Notes for Version February 2015

This document is published in:

Comparison of methods for quantitative analysis of dynamic susceptibility contrast enhanced brain perfusion MRI

Patient-Motion Analysis in Perfusion Weighted MRI

Pre-processing of ASL data T CT

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 December 1.

Parameter estimation in arterial spin labeling MRI: comparing the four phase model and the buxton model with fourier transform

Automatic Determination of Arterial Input Function for Dynamic Contrast Enhanced MRI in Tumor Assessment

Radiation dose reduction in computed tomography perfusion using spatial-temporal Bayesian methods

Semi-parametric Analysis of Dynamic Contrast-Enhanced MRI Using Bayesian P-Splines

A novel noise removal using homomorphic normalization for multi-echo knee MRI

A Model-Independent, Multi-Image Approach to MR Inhomogeneity Correction

Automated Determination of Arterial Input Function for DCE-MRI of the Prostate

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Diffuse light tomography to detect blood vessels using Tikhonov regularization Huseyin Ozgur Kazanci* a, Steven L. Jacques b a

Information about presenter

Introduction to Neuroimaging Janaina Mourao-Miranda

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

CP Generalize Concepts in Abstract Multi-dimensional Image Model Component Semantics. David Clunie.

Functional MRI data preprocessing. Cyril Pernet, PhD

Estimating Arterial Wall Shear Stress 1

Role of Parallel Imaging in High Field Functional MRI

Diffuse Optical Tomography, Inverse Problems, and Optimization. Mary Katherine Huffman. Undergraduate Research Fall 2011 Spring 2012

Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures

Computed Tomography Perfusion Imaging Denoising Using Gaussian Process Regression

Supplementary Figure 1. Decoding results broken down for different ROIs

Politecnico di Torino. Porto Institutional Repository

Anatomy-driven modelling of spatial correlation for regularisation of arterial spin labelling images

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

Application of Unsupervised Clustering Methods to Medical Imaging

Bayesian Inference of Hemodynamic Changes in Functional Arterial Spin Labeling Data

A validation of the biexponential model in diffusion MRI signal attenuation using diffusion Monte Carlo simulator

CTA HEAD Perfusion AqONE without and with IV Contrast

Basic fmri Design and Analysis. Preprocessing

Patch-Based Super-Resolution of Arterial Spin Labeling Magnetic Resonance Images

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Challenges in Improved Sensitivity of Quantification of PET Data for Alzheimer s Disease Studies

ADAPTIVE GRAPH CUTS WITH TISSUE PRIORS FOR BRAIN MRI SEGMENTATION

design as a constrained maximization problem. In principle, CODE seeks to maximize the b-value, defined as, where

Xingfeng Li. Functional Magnetic Resonance Imaging Processing

The University of Chicago. Center for EPR Imaging in Vivo Physiology. Image Registration. Boris Epel

Magnetic Resonance Angiography

Dynamic Contrast enhanced MRA

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

Empirical analyses of null-hypothesis perfusion FMRI data at 1.5 and 4 T

Evaluation of Hessian-based filters to enhance the axis of coronary arteries in CT images

Outline: Contrast-enhanced MRA

Time-Efficient Perfusion Imaging Using DCE- and DSC-MRI

Enhao Gong, PhD Candidate, Electrical Engineering, Stanford University Dr. John Pauly, Professor in Electrical Engineering, Stanford University Dr.

A Nonparametric Bayesian Approach to Detecting Spatial Activation Patterns in fmri Data

Mathematical methods and simulations tools useful in medical radiation physics

The MAGIC-5 CAD for nodule detection in low dose and thin slice lung CT. Piergiorgio Cerello - INFN

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Functional Imaging With Turbo-CASL: Transit Time and Multislice Imaging Considerations

ASAP_2.0 (Automatic Software for ASL Processing) USER S MANUAL

Time-Frequency Method Based Activation Detection in Functional MRI Time-Series

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

ADVANCED IMAGE PROCESSING METHODS FOR ULTRASONIC NDE RESEARCH C. H. Chen, University of Massachusetts Dartmouth, N.

Digital Volume Correlation for Materials Characterization

ABSTRACT. Eric S. Paulson 1, Douglas E. Prah 1, and Kathleen M. Schmainda 2

Lucy Phantom MR Grid Evaluation

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Edge-Preserving MRI Super Resolution Using a High Frequency Regularization Technique

RADIOMICS: potential role in the clinics and challenges

Guided Noise Reduction with Streak Removal for High Speed Flat Detector CT Perfusion

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

Automatic segmentation of the cortical grey and white matter in MRI using a Region Growing approach based on anatomical knowledge

A fast iterative thresholding algorithm for wavelet-regularized deconvolution

Optimizing Flip Angle Selection in Breast MRI for Accurate Extraction and Visualization of T1 Tissue Relaxation Time

An Efficient Computational Approach to Characterize DSC-MRI Signals Arising from Three-Dimensional Heterogeneous Tissue Structures

Removal of EPI Nyquist Ghost Artifacts With Two- Dimensional Phase Correction

Respiratory Motion Prediction for Renal Perfusion MRI

Application of level set based method for segmentation of blood vessels in angiography images

Feasibility and accuracy of 3D quantitative blood flow mapping of the prostate using dynamic contrast-enhanced multi-slice CT

UNIVERSITY OF SOUTHAMPTON

Improved Quantification of Arterial Spin Labelling Images using Partial Volume Correction Techniques. Ruth Abigail Oliver

MIDAS Signal Calibration

Analysis of Functional MRI Timeseries Data Using Signal Processing Techniques

Nuts & Bolts of Advanced Imaging. Image Reconstruction Parallel Imaging

Deconvolution with curvelet-domain sparsity Vishal Kumar, EOS-UBC and Felix J. Herrmann, EOS-UBC

Imaging Notes, Part IV

Segmentation of Intima Media Complex of Common Carotid Artery

Automatic Vascular Tree Formation Using the Mahalanobis Distance

Functional MRI in Clinical Research and Practice Preprocessing

Transcription:

XI Conference "Medical Informatics & Technologies" - 2006 medical imaging, MRI, brain perfusion Bartosz KARCZEWSKI 1, Jacek RUMIŃSKI 1 VALIDITY OF MRI BRAIN PERFUSION IMAGING METHOD Brain perfusion imaging with Dynamic Susceptibility Contrast MRI is very promising method since it can be easily implemented as a standard contrast-based MRI procedure. We present the results of a set of analysis to validate the DSC-MRI method. The influence of bolus dispersion, delay, low SNR and other possible sources that can influence the final perfusion parameter values were verified. Different methods of perfusion parameters calculations are also presented and compared to discuss the role of a chosen method in quality of brain perfusion images. 1. INTRODUCTION Parametric images represents values of reconstructed parameters for assumed tissue/activity model. This includes DSC-MRI [3], ASL MRI [5], dynamic PET/SPECT [1], dynamic active thermography [4], etc. In DSC-MRI imaging, after injection of a bolus of contrast agent (e.g. Gd- DTPA), a series of images are measured. This image-sequence data presents local voxel activity of contrast (blood) flow and distribution. It is assumed, that measured MRI signal values are proportional to the contrast concentration. Contrast concentration as a function of time is measured for brain supported arteries which is estimated as the arterial input function (AIF). In real conditions the AIF is not an ideal impulse function (dispersion and delay), additionally in DSC-MRI measurements are done from a volume of interest (VOI) therefore deconvolution is required to calculate VOI impulse response F*R(t): t ρ Ct ( t) = Ca ( τ ) ( F R( t τ )) dτ, (1) Kh 0 where: C a (t) - contrast concentration in the artery (e.g., Middle Cerebral Artery) Arterial Input ρ Function AIF, C t (t) - contrast concentration in the tissue, - scaling factor (quantitative Kh description), F*R(t) scaled impulse response (residue function) inside VOI. The R(t) - represents fractional tissue concentration. Assuming that contrast material remains intravascular and the first pass of the contrast bolus can be eliminated from the concentration function a set of perfusion related parameters can be calculated (using deconvolution to find R(t)). Since R(t=0) should be equal to 1, then 1 Department of Biomedical Engineering, Gdansk University of Technology,

36 Bartosz Karczewski et al. / XI Conference "Medical Informatics & Technologies" - 2006 F R( t = 0) = F = rcbf (regional Cerebral Blood Flow). (2) Regional cerebral blood volume (proportional to the normalized total amount of tracer) and mean transit time (average time required for any given particle of tracer to pass through the tissue after an ideal bolus injection) can be estimated as rcbv ρ = Ct ( τ ) dτ / Ca ( τ ) dτ ; rmtt=rcbv/rcbf. (3) 0 Kh 0 Image sequences for in-vivo measurements were collected using 1.5T MRI scanner (SE-EPI with: 12 slices, 50 samples, TR=1.25-1.61s; TE=32-53ms; slice thickness 5-10 mm; 60 series - 3000 images). Using own, created software (Java) we extracted signals and concentration curves used in further processing to reconstruct rcbf, rcbv and rmtt parametric images. Three types of quantitative parametric images (CBF, CBV, MTT), synthesized under strictly controlled procedure, offer additional information for brain studies. 2. INFLUENCE OF DISPERSION AND DELAY In quantitative DSC-MRI it is crucial to exactly measure an input, AIF function. Based on the AIF the required signal (F*R(t)) is deconvolved and used for quantitative maps synthesis. Theoretically the AIF describes concentration of contrast agent in the feeding vessel to the VOI. Practically it could be localized far away from VOI (carotid artery, middle cerebral artery). The path between measured AIF source and true AIF localization is unknown. The AIF delay and dispersion can be introduced using [2]: C true a where: h(t) vascular transport function, e.g.: ( t) = C ( t) h( t) (4) a 1 t h( t) = exp (5) td t D where: t D - dispersion constant. The influence of dispersion on final results (MTT or CBF) can be analyzed performing the following test. First the functions/signals of C a (t) and R(t) are assumed β K( t t0 ) e Ca ( t) = 0, t t0 α ( t t ) 0, t > t 0, (6) t R( t) = exp( ), (7) MTT where: K, α, β model parameters (used β=3, α=2/3), t 0 - bolus arrival time (BAT).

Bartosz Karczewski et al. / XI Conference "Medical Informatics & Technologies" - 2006 37 Then, the original C a (t) is convolved with the dispersion function for different values of the dispersion parameter t D equation (5). Finally, dispersed C a (t) functions are convolved with R(t) producing a set of C t (t). Calculation of MTT/CBF requires to deconvolve the R(t) from C t (t), assuming C a (t). Performing deconvolution of R(t) for any C t (t) from the generated set, using the original (without dispersion) C a (t) can be used to analyze the influence of dispersion on MTT/CBF quality. Similar analysis may be used to analyze the influence of delay in C a (t) on final results. The delay in the test set can be introduced using shift of samples. Other steps are identical as for dispersion investigation. Results The influence of dispersion was estimated using 10 different values of t D in the range of 0-7 seconds (typical MTT values for grey matter / white matter are 3-6s). Results (MTT as a function of t D ) are presented in Fig. 1b. 6,5 6 MTT [s] 5,5 5 4,5 4 0 1 2 3 4 5 6 7 8 t D [s] a) b) Fig.1. a) Example of the dispersion effect on C a (t). b) MTT as a function of dispersion (t D ) true value of MTT=5 In the range of sampling period (in DSC-MRI usually 1-2s) the error caused by dispersion is 5-10%. This is a lower bound since for real signals (lower SNR) the influence of dispersion can be even higher. Analysing the role of delay the shift in samples was used for the range 2 up to 5 samples (seconds). In Fig. 2a the results (MTT as a function of delay) of analysis are presented. 6 5,5 MTT [s] 5 4,5 4-3 -2-1 0 1 2 3 4 5 6 td [s] Fig.2. a) The influence of delay in C a (t) on MTT, true value of MTT=5s; b) deconvolved R(t) for dispersed (t D =2s) and delayed (2s) C a (t)

38 Bartosz Karczewski et al. / XI Conference "Medical Informatics & Technologies" - 2006 In the range of sampling period the error caused by delay is about 5%. In Fig. 2b the result of deconvolved R(t) for dispersed (t D =2s) and delayed (2s) C a (t) is presented (compare to (7)). Unfortunately, the achieved result had required matrix regularization (ill-posed matrix, build with C t (t) for linear deconvolution). The TSVD method was used [6]. In the range of sampling period the error produced by both effect is up to 20%. However for real signals the dominated effect on errors can be related with SNR, and then with the regularization process. 3. INFLUENCE OF A SIGNAL NOISE During a process of regularization it is very important to use appropriate regularization factor values, especially in a large disturbance of a signal. The experiments to analyze the influence of a signal noise and regularization factor values on perfusion parameters were investigated. Again the Gamma variate function was used with K=1, α =1, β=1, t 0 =0, to generate AIF (6). In the case of the R(t) function (7), a value of the MTT parameter was fixed to 5 (seconds). Signal C t (t) was distorted by a noise described by a normal distribution with a mean value fixed to zero and following values of a standard deviation [0, 0.01, 0.05, 0.1, 0.3, 0.5, 0.7, 1]. Additionally, to avoid dependency on fixed parameters K, α, β, t 0, F and MTT, a scale coefficient (maximum of C t (t)) was used, which was multiplied by a standard deviation value. Tests were repeated 100 times to obtain mean results. Quantitative comparison between true and calculated parameter values were described using: RMSE% = 1 p N = 1( p p) N 1 2 1 p N i i, = i Bias% (8) i= 1 ( p p) N where value p is a true value of a parameter, p i is an estimated value of a parameter in every step i, where N - number of steps. The goal of the tests was to obtain RMSE and Bias values as the function of introduced error (standard deviation), for CBF and CBV parameters. In the first case a constant value of regularization coefficient was used (= 10-2 ) (Test 1). Next the optimal value of a regularization factor was automatically calculated. It was performed for two configurations: Test 2 - optimization for CBF, Test 3- optimization for CBV. In the searching for the best values the assumed R(t) function values (an initial guess) were used. In real those values are unknown but performed tests are only to investigate the role of a noise and regularization process. Results In Tab. 1 - Tab. 3 the example results for Test 1-3 are presented. Tab. 1. Test 1 results: Fixed regularization value λ = 10-2 δ RMSE [%] CBF RMSE [%] CBV Bias [%] - CBF Bias [%] CBV 0 0 0-0.7473 0.7511 0.01 12.4 14.4 0.0572 0.3788 0.05 66.7 75 2.6068 3.1749 0.1 121.7 143.3 7.3263 8.067 0.3 368.2 430 21.2142 23.5769 0.5 647.8 735 39.1494 43.3167

Bartosz Karczewski et al. / XI Conference "Medical Informatics & Technologies" - 2006 39 0.7 865.9 996.3 49.7286 55.8438 1 1189.5 1374.4 77.3399 84.2707 Tab. 2. Test 2 results: Optimization for a CBF δ RMSE [%] CBF RMSE [%] CBV Bias [%] - CBF Bias [%] CBV λ 0 0 0.7511-0.0164-0.7473 0.01 0.01 0.0165 1.117-0.0003-1.0897 0.281 0.05 0.091 0.7639-0.006-0.4103 0.6355 0.1 0.1 1.4705-0.0077 0.9641 0.8959 0.3 0.0994 6.1568-0.0008 5.5812 1.6101 0.5 0.0901 10.955 0.0015 10.3718 2.0864 0.7 0.0832 15.6977 0.0005 14.8939 2.4954 1 0.0899 20.3769 0.0091 19.4394 2.985 Tab. 3. Test 3 results: Optimization for a CBV δ RMSE [%] CBF RMSE [%] CBV Bias [%] - CBF Bias [%] CBV λ 0 0.0165 0.7511-0.0164-0.7473 0.01 0.01 12.7627 0.2306 11.333-0.133 0.0397 0.05 4.3126 0.0204 2.5405-0.0021 0.5832 0.1 17.0457 0.0276-1.625 0 0.9932 0.3 13.0668 0.0419-12.1171 0.0007 2.0242 0.5 18.3853 0.0481-17.6852 0.0005 2.6869 0.7 22.2841 0.0555-21.5229 0.0043 3.2307 1 24.8288 0.0567-24.1608 0.0121 3.947 Using the fixed value of regularization factor the introduced noise has a large influence on the results. RMSE coefficient reached maximum of 1400% for the CBV parameter (similarly, CBF is near 1200%). In the Bias case, situation is similar. The obtained values are lower, maximum 85%, but sufficiently large to eliminate them from further analysis. Analyzing results for the best case of the regularization factor there is not possible to set a one, universal value that guarantee the best accuracy of searching parameters. Optimal calculation of CBV (or MTT) and CBF requires to repeat deconvolution process. Analyzing regularization data, we see that along with increasing of the noise standard deviation, the regularization factor value also is raising. However it seems that the influence of the noise (in analyzed range) is not a critical factor in comparison to dispersion problems described earlier. Since the image sequence SNR can be controlled the more attention should be focused on appropriate AIF indication. 4. FINAL CONCLUSION Performing appropriate quality assurance of measured signals and AIF extraction it is possible to reliable describe perfusion parameters using DSC-MRI. Since the method assumes the typical contrast-based procedure it can be easily used with most of current MRI scanners. The prepared software (Java) enables quantitative calculation of perfusion parameters for DSC-MRI. In Fig. 3 an example of graphical user interface with EPI T2 image (first in the sequence measured during bolus tracking) and calculated rbat, rcbv and rcbf images for a stroke case (limited perfusion in the observed left upper region) are presented.

40 Bartosz Karczewski et al. / XI Conference "Medical Informatics & Technologies" - 2006 Fig. 3. An example of the graphical user interface with a set of images (from top left): EPI T2 and calculated rbat [s], rcbv [ml/100g] i rcbf [ml/100g/min] for a stroke case ACKNOWLEDGEMENT This work was partly supported by the grant of Polish State Committee for Scientific Research (2003-2006) 4 T11E 042 25. BIBLIOGRAPHY [1] CAI W., FENG D. D., FULTON R., Content based retrieval of dynamic PET functional images, IEEE Transactions on Information Technology in Biomedicine 4 (2)152-158, 2000. [2] CALAMANTE F, Gadian D G and Connelly A 2000 Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition Magn. Reson. Med. 44 466 73 [3] ØSTERGAARD L, Weisskoff R M, Chesler D A, Gyldensted C and Rosen B R High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: I. Mathematical approach and statistical analysis, II. Experimental comparison and preliminary results Magn. Reson. Med. 36 715 36, 1996. [4] RUMINSKI J., KACZMAREK M., NOWAKOWSKI A., Medical Active Thermography A New Image Reconstruction Method, LNCS2124, Springer,2 74-281, 2001. [5] WANG J., ALSOP D. C., LI L., LISTERUD J., GONZALEZ-AT J. B., SCHNALL M. D., DETRE J. A., Comparison of Quantitative Perfusion Imaging Using Arterial Spin Labeling at 1.5 and 4.0 Tesla, MRM 48:242 254, 2002. [6] WU L., A Parameter Choice Method For Tikhonov Regularization, Electronic Transactions on Numerical Analysis. Volume 16, pp. 107-128, Kent State University, 2003.