A P P L I C A T I O N

Similar documents
CBA 1000 CHARACTERISTICS

CBA HV Circuit Breaker Analyzer and Microhmmeter

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

3 analog linear/rotary transducers and 3 digital transducers inputs for travel/ speed analysis

DATE: 18/01/2011 DOC.SIE10166 REV.10 CIRCUIT BREAKER ANALYZER AND MICROOHMMETER MOD. CBA1000

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT126

DATE:25/07/2016 DOC.SIE10169 REV.14

Circuit Breaker Analyzer & Timer CAT126

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Circuit Breaker Analyzer & Timer CAT31

DRTS 33. The new generation of advanced three phase relay test set

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

DRTS 66 can test all the following relays

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CAT I series Circuit Breaker Analyzers & Timers

CAT II series Circuit Breaker Analyzer & Timer CAT64B

CAT I series Circuit Breaker Analyzers & Timers

Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT-P

CAT II series Circuit Breaker Analyzers & Timers

Circuit Breaker Analyzer & Timer CAT-P

CAT II series Circuit Breaker Analyzer & Timer CAT65A

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

CAT II series Circuit Breaker Analyzers & Timers

On the other side, performing tests is an expensive task, demanding

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

CT-8000 S3. digital circuit breaker analyzer

CT-8000 S3 digital circuit breaker analyzer

EGIL Circuit breaker analyzer

EGIL Circuit breaker analyzer

DIGITMR S2 PC. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

EGIL Circuit breaker analyzer

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

TFS 2100 Traveling Wave Fault Location System

Circuit Breaker Analyzer System

Micro Ohmmeter RMO200G

Ordering Information CIBANO 500

CIBANO in-1 test system for medium- and high-voltage circuit breakers

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

THE INTEGRATED TESTING SOLUTION

Testing Instruments Manufactured by

ACTAS P. Portable Switchgear Test Systems K O C O S M E S S T E C H N I K A G

Tri-Phase. true 3-phase transformer turns ratio tester

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

CT-7000 S3 DIGITAL CIRCUIT BREAKER ANALYZER

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

DCM Dynamic Contact Measuring

Demonstration Case BENNING DB 1

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

SM100. On-Line Switchgear Condition Monitoring

ATRT-03B S2. automatic, 3-phase transformer turns ratio tester. Vanguard Instruments Company, Inc.

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Switch Analyzer SA10 & DCM Dynamic Contact Measuring

MJÖLNER 200 Micro-ohmmeter

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Power consumption In operation At rest For wire sizing

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

D.C.M Dynamic Contact Measurement User Manual page 1(22) INDEX GENERAL APPLICATION AREA OVERVIEW SAFETY...

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product Description. Contents. Fusion Series. New Information December 2003

UH28C. High Voltage Tester. Product Information Sheet V AC / 100 ma

MJÖLNER 600 Microhmmeter

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TM1800. Circuit Breaker Analyzer System Programma Products

Series Watt DC Power Supplies

DS2020SingleAxis ExtremelyCompact ServoDrives

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Introduction. Chapter 2

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

OPERATING INSTRUCTIONS for the CT Digital Circuit Breaker Analyzer

ATRT-03 S2. automatic, 3-phase transformer turns ratio tester

Programmable DC Power Supplies XLN Series

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ADVANCED TEST AND DIAGNOSTIC SYSTEMS.

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

Transcription:

Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for EHV, HV and MV circuit breakers Stand alone functionality - no PC connection is required Large graphical high brightness sunlight display Analysis and result evaluation directly on the display Internal memory for up to 250 test results and 64 pre-defined test plans. Cross trigger for the synchronization of up to 4 CBA 1000 Circuit Breaker test with both ends connected to ground (BSG option) TDMS software for test results analysis and reporting. A P P L I C A T I O N CBA 1000 is a unique tool for the complete test of all circuit breakers. It is a powerful timing and motion analyzer test set with built-in 200 A pure DC current microohmmeter for static and dynamic contact resistance tests. CBA 1000 is a stand alone unit with a large graphical display. The unit is supplied with TDMS analysis software. TDMS performs test results analysis and creates test reports; it allows also to pre-define test plans. TDMS is also a powerful Test and Data Management software, compatible with all ISA Test Sets. All CBA 1000 circuits have been designed to ensure safe and reliable operations in the noisy environment of HV / MV substations and power plants. C H A R A C T E R I S T I C S Coil operation. Number of circuits: 2 (1 Open and 1 Close coils); optional 4 (3 Open and 1 Close coils).. Type of driver: electronic; it ensures superior timing control.. Driver characteristic: 300 V DC max; 30 A DC max.. Operating time accuracy: 0.025% of delay ± 100 µs.. Measurement of the coil current: one per channel; the waveform is displayed on the dedicated channels.. Coil current ranges: 2.5; 10; 25 A full scale, user selectable.. In case of 4 coils option, it is possible to select the single or multiple phase opening.. Coil current measurement accuracy: 0.5% of the reading ± 0.1% of the selected range.. Outputs are isolated between them. Main contact inputs. Number of contact inputs: 6 Main contacts (2 break per phase) plus 6 Resistor contacts (2 break per phase).. Resistor contact ranges: from 20 Ohm to 10 kohm.. Contact test voltage: 24 V. Main contact test current: 50 ma.. Each input group is isolated with respect to the others. Event inputs. Number of auxiliary event inputs: 4, divided in 2 groups of 2 each.. Capability of testing dry (24 V) or wet contacts (20 to 300 V). Test current: 2 ma. Sample rates 20 khz - 10 khz - 5 khz - 2 khz - 1 khz - 500 Hz - 200 Hz - 100 Hz, 50 Hz, 20 Hz user selectable. Timing accuracy 100 µs ± 0.025% of the time reading at 20 khz. Maximum record length 1000 s.

. Resistance measurement accuracy: 1% of the reading ± 0.2% of the range. Minimum trip Voltage test (Option) The minimum trip voltage test allows to verify the minimum trip voltage threshold and the voltage drop-off delays.. Two options: 250 V Max and 70 V Max.. Maximum current: 4 A (250 V); 10 A (70 V).. Maximum voltage adjustement: up to 50% of V Max. Internal or external Printer (Option). Optional internal thermal printer 58 mm wide.. Optional external thermal printer: Seiko DPV-414, 112 mm wide. CBA 1000 test result display Analog inputs. Number of analog inputs: 4 (6 Optional).. 2 (4 optional) dedicated to Open and Close coil currents.. 1 dedicated to Dynamic and Static Resistance Measurement. Input voltage range: ± 5 V.. 1 dedicated to travel, velocity, station battery voltage, etc. Input voltage range: ± 5 V.; ± 50 V; ± 500 V, user selectable.. Analog inputs are isolated with respect to all other circuits.. Analog input measurement resolution: 16 bit. Test set control. The control is local, via graphical display, keypad and pushbutton for menu selection: no PC control is necessary. Display Large graphical high brightness sunlight display (viewing area 122 x 92 mm). Test results are displayed graphically and in table format. Zoom functions and cursors for test data analysis are directly available on the CBA 1000 display. Interfaces to PC 2 available interfaces: USB and RS232. Memory size 128 Mbytes (approx. 250 results). TDMS software TDMS is a powerful software package, providing data management for commissioning and maintenance testing activities. Circuit breaker data and test results are saved in the TDMS database for historical results analysis. Microhmmeter display Programmable sequences The user can select the following Open and Close sequences: Open; Close; Open-Close; Close-Open; Open-Close-Open. Static and Dynamic resistance measurement (Option). DC Test current: 200 A, 100 A, 20 A.. Resistance measurement ranges 200 µohm; 1 mohm; 10 mohm; 100 mohm, user selectable.. Resolution: 0.1 µohm; 1µOhm; 10 µohm; 100 µohm. Test & Data Management Software

TDMS software has the following main features.. Full control of CBA 1000 functions from PC.. Download of test plans.. Download of test results.. Test plans and test results can be viewed, edited in the missing descriptions, saved, printed, exported.. Possibility of viewing, overlaying and gluing more results, for an easy test result comparison.. Possibility to pre-set test plans and to upload them into the test set.. Two cursors select measurement points and intervals.. Zoom in and out feature.. Enhanced measurement features for movement - speed - acceleration control. ISA software updating policy allows all users to update their software from the ISA web site www.isatest.com, at no additional cost. Test result analysis Other characteristics CBA 1000 can operate both from mains (AC or DC) and from an internal rechargeable battery:. Mains supply:. From 85 to 265 V AC; 50-60 Hz.. From 100 to 350 V DC.. Internal battery. Battery type: NiMh.. Case: aluminium, with hinged removable cover and handle.. Dimensions: 400(W) * 300(D) * 240(H) mm. Weight: 10 kg basic unit; 11 kg with Microhmmeter module. S T A N D A R D A C C E S S O R I E S The following accessories are supplied with the unit:. Mains cable. User s manual for hardware and software. Serial cable. Grounding cable. USB cable. Spare fuses. Software TDMS. O P T I O N A L A C C E S S O R I E S The following options are available upon request:. Basic unit test cable kit The set includes:. N. 3 Cables for connection to Main contacts;. N. 2 Cables for connection to Auxiliary contacts;. N. 1 Cable for connection to Breaker Coils.. N. 1 Cable for Low Voltage Measurement.. N. 1 Kit of adaptors and N. 1 adaptor 15 cm long.. N. 1 Cable for connection to Trasducers.. N. 1 Kit of auxiliary cables and a kit of crocodile clamps.. Transport Plastic bag.. Additional 2 Open driving coils module This module increases to 3 the number of Open Coils.. Built-in 200 A Static / Dynamic resistance module with 10 m long test cables, cross section 25 sq.mm, terminated with high current clamps.. Minimum trip Voltage test. Internal thermal printer. CBA 1000 has an (optional) built-in thermal printer, 58 mm wide.. BSG 1000 is an enhanced safety external module, that allows to test the circuit breaker with both sides connected to ground.. CBA Heavy duty transport case with wheels.. CBA plastic soft bag.. Linear transducer. Linear transducer: TLH 150-150 mm length (IP40).. Linear transducer: LWG 150-150 mm length.. Linear transducer: TLH 225-225 mm length (IP40).. Linear transducer: LWG 225-225 mm length.. Linear transducer: TLH 300-300 mm length (IP40).. Linear transducer: TLH 500-500 mm length (IP40).. Linear transducer: LWG 500-500 mm length.. Pressure transducer: PA-21 Y 40 BAR.. Rotary transducer: IP 6501-355 rotation angle.. Universal transducer mounting kit for TLH, LWG and IP travel transducers.. Hall effect clip-on transformer. It allows measuring the DC current of motors and of the auxiliary supply. APPLICABLE STANDARD The test set conforms to the EEC directives regarding Electromagnetic Compatibility and Low Voltage instruments.. Electromagnetic Compatibility: Directive 2004/108/EC (CE conform). Applicable standard: EN 61326:2006.. Low Voltage Directive: Directive 2006/95/EC (CE conform).. Applicable standards, for a class I instrument, pollution degree 2, Installation category II: CEI EN 61010-1. In particular:. Inputs/outputs protection: IP 2X - CEI EN 60529.. Operating temperature: -10 C to 55 C; storage: -20 C to 70 C.. Relative humidity: 10-95% without condensing.

O R D E R I N G I N F O R M A T I O N CODE MODULE 10166 CBA 1000 basic unit supplied with 10015 TDMS - Test & Data Management Software O P T I O N A L A C C E S S O R I E S CODE MODULE 15166 CBA1000 Test Cables Kit with transport case 43166 Additional 2 Open Coils Module* 23166 200 A Static / Dynamic Resistance Module (with test cables 10 m terminated with clamps)* 33166 Internal Thermal Printer*; ** 14102 External Thermal Printer 4.5 18166 Heavy Duty Plastic Transport Case 19166 Plastics soft bag 34166 MTC - Minimum Trip Coil test module*; ** 11166 TLH 150 Linear Transducer 150 mm 12166 TLH 225 Linear Transducer 225 mm 36166 TLH 300 Linear Transducer 300 mm 13166 TLH 500 Linear Transducer 500 mm 14166 Rotary Transducer: IP 6501 355 rotation angle 26166 LWG 150 Linear Transducer 150 mm 27166 LWG 225 Linear Transducer 225 mm 28166 LWG 500 Linear Transducer 500 mm 13169 Pressure Transducer PA-21 Y 40 BAR 29166 Hall effect clip-on transformer 16166 Universal Analogic Transducer mounting kit 44166 Flexible Coupling Shaft Op ons with * must be specified at order. Op ons with ** are exclusive each other: code 33166 Internal thermal printer cannot be ordered together with code 34166 Minimum Trip Voltage Test Module. CBA 1000 - Transport Case CBA 1000 - Cable Transport Case CBA 1000 - Soft Bag Transducer case Mounting Kit Hall effect clamp TLH Linear Transducer LWG Linear Transducer Rotary Transducer CBA 1000 - Example of test cable kit

Option for ISA Circuit breaker Analyzers CBA 1000 and CBA 2000 Work safely while testing Save circuit breaker testing and analysis time Preserve all timing and motion test integrity BSG 1000 allows the test of circuit breakers using Graphite Nozzle This method applies to all kinds of circuit breakers. I N T R O D U C T I O N With the BSG option it is possible to perform the circuit breaker timing test with both sides grounded. The grounding connection is NOT removed during the test, as it has to be with conventional test equipment. Safety is becoming more and more important, and several laws and regulations all around the world prescribe that, at the work location in high voltage installation, all parts which are to be worked on, shall be earthed ( grounded ) and short circuited. While testing a Circuit Breaker in high voltage substations the situation may become dangerous due to the high electric potential. This can be caused by a capacitive coupling from a close conductor or when lightning strikes the line somewhere, or when a fault occurs during the test and a high potential reaches the circuit breaker. To improve personnel safety, reduce hooking time and preserve the test set integrity, the use of BSG 1000 is the best practice. BSG 1000 is also the best solution for testing Circuit Breakers equipped with Graphite Nozzles.

D E S C R I P T I O N Two BSG 1000 types are available: BSG 1000- type 1 for testing one break per phase; BSG 1000- type 2 for testing two breaks per phase. Each BSG 1000 is made of the following elements:. Three BSG Remote Heads, connected close to the main breaker contacts. Remote Heads for BSG 1000- type 1. Each head has two cables, 2.5 m long, cross section 4 mm 2, terminated with crocodile clamps.. One bipolar shielded cable, 3 m long, terminated with crocodile clamps.. One 8 m long cable, terminated with multi-pole connectors for the connection between Remote Heads and the BSG Main unit. Remote Heads for BSG 1000- type 2. Each head has three cables, 2.5 m long; cross section 4 mm 2, terminated with crocodile clamps.. Two bipolar shielded cables, 3 m long, terminated with crocodile clamps.. One 8 m long cable, terminated with multi-pole connectors for the connection between Remote Heads and the BSG Main unit.. One BSG Main unit, connected to the CBA 1000 or CBA 2000 circuit breaker analyzer.. Connection of BSG Main Unit to CBA 1000: via a cable 1 m long, terminated with a multi-pole connector. S P E C I F I C A T I O N. Number of main contact inputs (type BSG 1000-1): 3, divided in three groups.. Number of main contact inputs (type BSG 1000-2): 6, divided in three groups of two each.. Test current injection: 20 A DC nominal.. Maximum test duration (each test): 1 s. Graphite nozzles test selection in the menu. CBA 1000 connected to BSG 1000 Mains supply. From 85 to 265 V AC; 50-60 Hz, and:. From 100 to 350 V DC.. Maximum supply current: 1 A @ 85 V AC. Weight and dimensions BSG 1000 main unit. Case: aluminium case, with hinged removable cover and handles.. Weight: 6 kg. Dimensions: 325 x 180 x 285 (W x H x D) BSG 1000 - Remote Head, type 1 BSG 1000 remote heads (three units). Case: die-cast aluminium case.. Weight: 0,7 kg (without cables). Dimensions: 125 x 56 x 125 (W x H x D)

O R D E R I N G I N F O R M A T I O N CODE MODULE CODE MODULE 22166 BSG 1000 One break per phase including:. No 3 BSG Remote Heads Type1. No 1 BSG Main unit. No 1 Cables kit 21166 BSG 1000 Two breaks per phase including:. No 3 BSG Remote Heads Type2. No 1 BSG Main unit. No 1 Cables kit 17166 Heavy duty plastic transport case for BSG 1000 CBA 1000 connected to BSG 1000 and circuit breakers The document is subject to change without notice. Always refer to our technical specification for more detailed information and as formal contract document.