Firmware Manual - EC Series Drives

Similar documents
QUICK REFERENCE GUIDE

Quick Start Guide For GVX9000 AF Drives

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

Optidrive VTC Modbus RTU Register Map

Optidrive Applications Support Library

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Optidrive Applications Support Library

SV9000 AF DRIVES SVReady User Manual. Pump and Fan Control Application

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

3GV M Modbus RTU Register Map

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

Power Connections: Basic Wiring:

Unidrive M400 (Frame 1 to 4) Quick Start Guide

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

OptiDrive Advanced Technical Manual

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

1336 PLUS II Quick Start Guide

E2 Modbus RTU Register Map

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

SENSORLESS VECTOR CONTROL

Optidrive Plus 3 GV. Advanced User Guide. Vertical Market Solution : Industrial Washing Machines. Revision 1.00

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

Bus Regulation. PowerFlex 755 AC Drives. For Classroom Use Only!

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 3

Parameters MICROMASTER 420

GV3000/SE AC Drive Quick Reference Version 6.06

vacon nx ac drives brake chopper unit (bcu) application user s manual

DriveWare. User s Guide DriveConfig

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

PowerFlex 40 Sample Specification

SED2 Variable Frequency Drives

Control Quick Start Guide. Unidrive M200/201. Flexible machine integration through communications. Part Number: Issue: 2

COMBIMASTER 411 & MICROMASTER 411

Control Quick Start Guide. Unidrive M300. Enhance throughput with machine safety. Part Number: Issue: 2

Unidrive M400. Control Quick Start Guide

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Reliance GV3000 Drive Registers

LS M100 Frequency Inverter Easy Start Guide

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

TL5 Programming Terminal USER MANUAL

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

User Manual. PROFIBUS-DP Option Board for SV-iS5 Series. LG Industrial Systems

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

Flexible, simple, economical, robust.

Basic Drive Programming PowerFlex 755 Basic Start Up

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

AF-600 FP AC Drive AC Adjustable Frequency Drive Guide-Form Specification

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

DriveWare. User s Guide DriveConfig

Control Quick Start Guide. Unidrive M200/ M201. Flexible machine integration through communications. Part Number: Issue: 4

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

VFA7/VFP7 Parameter List (Ver315)

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

vacon 100 hvac ac drives application manual

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Frequency Inverters WJ200 Series Compact Inverter

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06

IMPORTANT! PLEASE READ!

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

Important Safety Notice

User Manual. RS485 Option Board for SV-iS5/iH Series. LG Industrial Systems

Step 1: Choose the Appropriate CPU Step 2: Make the Connections

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

VLT 2800 DRIVE SPECIFICATIONS

Distributed Power System SA3100 Drive Configuration and Programming

MCH Series Drives Metasys N2 Communications Guide

For Classroom Use Only! Flying Start PowerFlex 755 AC Drives

MC Series Drives. Flexible, simple, rugged, robust!

User manual. MODBUS-RTU SV-iC5

4. Setting parameters

A66N2 Installation and Programming Manual

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Vacon HVAC100 Commissioning Guide

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 4

SMVector Additional I/O Module Installation and Operation Manual

Opal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1

RM5G Series Simple Version Operation Manual

1-1 AC DRIVE OVERVIEW EXERCISE OBJECTIVE

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

IM-pAC. Getting Started Guide. AC variable speed drive for 3 phase induction motors from 0.25kW to 4kW, 0.33hp to 5hp. Model sizes A, B and C

ADJUSTABLE SPEED AC MOTOR CONTROL

Softstarters. Type PST/PSTB Fieldbus communication DeviceNet for PST sw CU SFC132072M0201 February SFC132072M0201 1

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives

STEP MOTOR DRIVER SMD-4.2DIN

Control Mode Application and Selection Guide

INTER PLANT STANDARD STEEL INDUSTRY

DC1 Series 1 Hour Product Overview Eaton Corporation. All rights reserved.

890 Quickstart Manual

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Transcription:

1 Firmware Manual - EC Series Drives Doc Ver 1.01 Firmware ver: EC series drives For installation details refer to Hardware Manual Safety: Read safety instruction in hardware manual before installation and commissioning drive. Some safety instructions associated with specific parameters should be complied with. These instructions are included in parameter description. This manual is meant for qualified personnel with knowledge of electrical schematics, basic electrical circuits and wiring.

2 Table of contents 1. Display and Parameter editing 2. Quick Start up 3. Parameter Summary 4. Parameter Description

3 1. Display and Parameter editing Press Press Select Parameter to be edited using up, down keys Parameter value can now be edited using up, down keys Press Enter to save parameter value

4 2. Quick Start up Connect drive as per instructions in Hardware manual. For quick start up of induction motor: 415VAC, 4pole, 50 Set P -033 = motor rated current. Drive is now ready for run command. 3. Parameter Summary Parameter Runtime Parameter Range Default Unit number operability P-000 Set frequency Read only P-001 Drive output frequency Read only P-002 Output Current Amps Read only P-003 DC link Voltage Volts Read only P-004 Output Voltage Display values Volts Read only P-005 HS temperature o C Read only P-006 Power KW Read only P-007 Counter value Read only P-008 Firmware Version Read only P-009 Frequency Reference 0:Zero Speed 1:Keypad ref 2:Analog input ref 1 Read-Write 3:Motorized pot ref P-010 Minimum Speed 0-999.9 0.5 Read-Write P-011 Maximum Speed 0-999.9 50.0 Read-Write P-012 Acceleration Time 0.1-999.9 10.0 Sec Read-Write P-013 Deceleration Time 0.1-999.9 10.0 Sec Read-Write P-014 Operator select 0:Keypad 1:Control Terminals 0 Read only P-015 DI-1 0 : Disable input 1 : RUN 2 : STOP 1 Read-Write P-016 DI-2 3 : REV 4 : Jog Start 5 : Fault Reset 6: Emergency Stop 2 Read-Write P-017 DI-3 7: Reserved 8: Mot Pot up 9: Mot Pot Down 10: Preset speed 1 12 Read-Write P-018 DI-4 11:Preset speed 2 12:Pulse Counter 13-Pulse Counter Reset 13 Read-Write

5 P-019 DI-1 Invert 0 Read-Write P-020 DI-2 Invert 0: Non inverting 0 Read-Write P-021 DI-3 Invert 1: Inverting 0 Read-Write P-022 DI-4 Invert 0 Read-Write P-023 Reserved P-024 Ext Start/Stop Mode 0:3 Wire Mode 1:Fwd Run /Rev Run 0 Read-Write 2:Run/Fwd P-025 Stop Mode 0:Coast 1:Ramp 0 Read-Write P-026 Analog inp filter time 0.00-25.00 0.30 Sec Read- Write P-027 Analog inp max 0.00-10.00 9.40 Volts Read- Write P-028 Analog inp min 0.00-10.00 0.00 Volts Read- Write P-029 Analog inp max ref 0.0-999.9 50.0 Read- Write P-030 Analog inp min ref 0.0-999.9 0.00 Read-Write P-031 Reserved P-032 Motor Rotation 0:Forward 1:Reverse 0 Read only P-033 Motor Nom Amps 0.00-99.9 4.6 Amps Read only P-034 Motor Rated Voltage 0-690 415 Volts Read only P-035 Motor Rated frequency 0.00-500.0 50.0 Read only P-036 Motor Rated Speed 0-9999 1500 RPM Read only P-037 V/f Volt 1 0-1000 5 Volts Read only P-038 V/f Volt 2 0-1000 5 Volts Read only P-039 V/f Volt 3 0-1000 415 Volts Read only P-040 V/f Freq 1 0.0-500.0 0.5 Read only P-041 V/f Freq 2 0.0-500.0 0.5 Read only P-042 V/f Freq 3 0.0-500.0 50.0 Read only P-043 Motor Poles 2-15 4 Read only P-044 IR Compensation 0.0-50.0 0.0 % Read only P-045 Slip Compensation 0:Disable 1: Enable 0 Read only P-046 Auto Torque boost 0:Disable 1: Enable 0 Read only P-047 Current Limit 0-300 110 % Read only P-048 Reserved P-049 Reserved P-050 Reserved P-051 Reserved P-052 Jog reference 0-999.9 10.0 Read-Write P-053 Jog acceleration time 0.1-999.9 10.0 Sec Read-Write P-054 Jog deceleration time 0.1-999.9 10.0 Sec Read-Write P-055 Preset Speed select 1 0-999.9 10.0 Read-Write P-056 Preset Speed select 2 0-999.9 20.0 Read-Write P-057 Preset Speed select 3 0-999.9 30.0 Read-Write

6 P-058 Preset Speed select 4 0-999.9 40.0 Read-Write P-059 E2prom Default 0:Disable 1:Enable 0 Read only P-060 Reserved P-061 Reserved P-062 Dynamic brake select 0:Disable 1:Enable Read only P-063 Power up Parameter Power up display selection 0 Read-Write P-064 Auto Fault Reset 0:Disable enable 1:Enable Read-Write P-065 Time between retries 0.5 to 150.0 sec 10.0 Sec Read-Write P-066 Analog out config 0:Set frequency 1:Output frequency 0 Read-Write 2:Output current P-067 Analog op max ref 0.00-500.00 50.00 Read-Write P-068 Analog op min ref 0.00-500.00 0.50 Read-Write P-069 Analog op max 0.00-10.00 10.00 Volts Read-Write P-070 Analog op min 0.00-10.00 0.00 Volts Read-Write P-071 DIO o/p config 0:Drive fault condition 1:Run condition 2:Set frequency 3:Desired frequency 4:Drive is ready to Run 1 Read-Write 5:Direction reversal 6:Under voltage trip 7:Counter match P-072 DIO on time 0.000-60.000 0.000 Sec Read-Write P-073 DIO off time 0.000-60.000 0.000 Sec Read-Write P-074 Desired Frequency 0.0-500.0 50.0 Read-Write P-075 Counter match value 0-9999 1000 Nos Read-Write P-076 Motor Stator Resistance 0.00-655.35 2.66 Ohms Read only P-077 Reserved

7 4. Parameter Descriptions Numb er Parameter Description Unit P-000 Set Frequency Set frequency before ramp. P-001 Output Frequency This is the ramp output frequency. P-002 Output Current Output current of the drive. Amps P-003 DC Link Voltage DC bus voltage Volts P-004 Output Voltage Drive output voltage. Volts P-005 HS Temperature Heatsink temperature of the drive C P-006 Power Power output of the drive KW P-007 Counter Value Input pulses (0-24V) are counted. Maximum counter input frequency = 250. P-008 Firmware version Installed firmware version Range: 0 3 Default: 1 Description: Frequency ref can be selected as follows: P-009 Frequency reference 0 Zero Speed 1 Keypad reference 2 Analog input reference 3 Motorized pot ref P-010 Minimum Speed Range: 0 999.9.50 Description: Set Frequency cannot be set below this value. P-011 Maximum Speed Range: 0 999.9 Default value: 50.0 Description: Set Frequency cannot be set above this value. P-012 Acceleration Time Range: 0.1 999.9s Default value: 10.0s Description: Final frequency reference ramps up from 0 to rated Sec frequency P-035 in this time. P-013 Deceleration Time Range: 0.1 999.9s Default value: 10.0s Description: Final frequency reference ramps down from rated Sec frequency P-035 to 0 in this time. P-014 Operator Select Default value:0 Description: Operator options: 0 Keypad 1 Control Terminals

8 P-015 DI-1 P-016 DI-2 P-017 DI-3 P-018 DI-4 Range : 0 13 Default value: DI1: 1,DI1: 2,Di3: 12,DI4: 13 Description: Digital inputs(0-24v) can be set up as follows: Selection Description 0 Disable input Disable input terminal 1 RUN Run command 2 STOP Stop command 3 REV Rev command 4 Jog Jog command 5 Fault Reset External fault reset 6 Emergency Stop Emergency stop when this command is selected. 7 Reserved 8 Mot Pot up Set frequency increase. 9 Mot Pot Down Set frequency decrease. 10 Preset speed sp1 See preset speeds. 11 Preset speed sp2 12 Pulse Counter Pulse counter input (max 250). 13 Pulse Counter Reset Reset pulse counter P-019 P-020 P-021 P-022 DI-1 invert DI-2 invert DI-3 invert DI-4 invert P-023 Reserved Reserved Default Value: 0 Description: Actuation of digital input occurs on 0V if inverted. 0 Non Invert Actuation on 24V input 1 Invert Actuation on 0V input

9 Range: 0-2 Description: Start/Stop configurations: 0 3 wire mode 1 FWD RUN/ REV RUN 2 RUN/FWD P-024 Ext Start/Stop mode 3 wire mode: RUN(ext) STOP(ext) Drive status 0 ----> 1(transition) 1 Start Any 1 --->0 (transition) Stop Any 0 Stop FWD RUN/REV RUN: RUN REV Drive status 0 1 FWD Start 1 0 REV Start 0 0 Stop 1 1 Stop P-025 Stop mode P-026 P-027 P-028 Analog inp filter time (Analog Input filter time) Analog inp max (Maximum Voltage at Analog Input) Analog inp min (Minimum Voltage at Analog Input ) RUN/FWD: Start command is given when RUN is actuated (non-latching). Direction is selected by REV terminal. Description: 0 Coast Stop Range: 0-1 1 Ramp Stop Range: 0.00 25.00s.30s Description: This is the time constant of the moving average analog input filter. Increase this value for a noisy input line. Analog voltage input 0.00V Default value: Max analog inp = 9.40V Min analog inp = 0V Max voltage P.027 Min voltage P.028 Ref Min P.030 Frequency ref Ref Max P.029 Sec Volts

10 P-029 P-030 Analog inp max ref (Reference at Max Analog input) Analog inp min ref (Reference at Min Analog input) P-031 Reserved. P-032 Motor Rotation P-033 Motor Nom Amps (Motor rated current) P-034 Motor Rated Voltage P-035 P-036 Motor Rated Frequency Motor Rated Speed in RPM Range: 0 999.9 Default value: Analog inp max ref = 50.0 Analog inp min ref = 0.0 Description: This is the frequency ref at maximum input voltage and frequency ref at minimum input voltage... Frequency ref = x Analog input(v) + P0.30.. Description: This parameter is used to set the direction of rotation of motor. 0 Forward 1 Reverse Range: 0 99.9A Default value: 4.6A Description: This is the rated current as shown on the name plate of the motor. If this current exceeds the rated current of the drive, the rated current of the drive takes precedence. In that case over current trip and current limits would be set as per drive rated current. Range: 0-690V Default value: 415V Description: This is the rated voltage as shown on the name plate of the motor. Range: 0 500.0 Default value: 50.0 Description: The rated frequency of the motor should be entered here. Motor voltage P-034 along with motor rated frequency is used to determine V/f curve applied to the motor. Range: 0-9999 Default value: 1500 Description: Motor rated speed on name plate is used to determine rated slip of motor. Rated slip() = rated motor frequency - P. P. = P.035 a Amps Volts RPM

11 P-037 P-038 P-039 V/f Volt1 V/f Volt2 V/f Volt3 Description: These parameters are used to set a user defined V/f curve. A user defined V/f curve can be applied as shown: Voltage Default Parameter Range V3 value V/f Volt1 5 V/f Volt2 5 V/f Volt3 415 0-1000V V2 V1 User V/f curve Volts f1 f2 f3 Frequency Description: These are the frequencies of the user defined V/f curve. P-040 P-041 P-042 V/f Freq1 V/f Freq2 V/f Freq3 P-043 Motor Poles P-044 IR Compensation P-045 Slip Compensation P-046 Auto Torque boost Parameter Default value Range V/f Freq1 V/f Freq2 V/f Freq3 0.5hz 0.5 50.0 0 500.0 Range: 2 15 Default value: 4 Description: Motor poles are used to determine synchronous speed of induction motor and for slip calculation. If synchronous speed is known the number of Ra P. Poles = Ra h Range: 0 50 Default value: 1 Description: Additional voltage is added to the drive output voltage at low frequency for higher motor torque. Warning: Too high value of this parameter can activate current limit or OC trip. Description: Slip compensation compensates for drop in speed with load. Rated slip() = N P. Ra P. Rated frequency P. 035 Note: For higher slip compensation, rated speed of the motor can be reduced. 0 Disable 1 Enable Description: 0: Auto torque boost is disabled. IR value in P-44 can be set to provide the required troque boost. %

12 1: Auto torque boost is enabled. The amount of IR compensation is now set automatically. P-047 Current limit Range: 0 300 Default value: 110 Description: Current limit when activated: 1. Reduces post ramp ref or prevents acceleration if drive is accelerating. 2. Holds or increases post ramp ref if drive is decelerating. P-048 Reserved. P-049 Reserved P-050 Reserved P-051 Reserved P-052 Jog reference Range: 0.0 200.0 Default value: 10.0 P-053 Jog acceleration time Range: 0.1 999.9 P-054 Jog deceleration time Default value: 10.0 P-055 Preset Speed select1 Range: 0 999.9 P-056 Preset Speed select2 P-057 Preset Speed select3 P-058 Preset Speed select4 P-059 E2prom default Description: A preset speed when selected bypasses the drive frequency reference. Any user terminal from IN1 to IN4 can be configured for preset speed input. Parameter Default Value() Preset Speed select1 10 Preset Speed select2 20 Preset Speed select3 30 Preset Speed select4 40 Description: E2PROM parameters can be set to factory default value using this parameter. If motor ratings are different from the default parameter settings, these have to be set after restoring default values. A CE Co u icatio Error essage is displayed if a y of the drive parameters are not within range. 0 Disable factory defaults 1 Restore factory defaults P-60 Reserved P-61 Fan Operation Default value: 1 Description: 0: Fan starts if heatsink temperature exceeds 60 o C. 1: Fan starts on RUN command to the drive. P-63 Power up parameter Range: 0 8 Description: Power up display can be selected from P.00 to P.08. P-63 Power up Display 0 Set frequency 1 Drive output frequency % Sec

13 P-64 Auto Fault Reset enable P-65 Time between retries P-66 Analog out config(optional)* 2 Output current 3 DC bus voltage 4 Output voltage 5 HS temperature 6 Power 7 Counter value 8 Firmware Version Description: Any fault condition is automatically reset after P-65(time between retries) has elapsed. Note: Auto reset is disabled for SC (short circuit) trip. Range: 0.5 150.0 Default value: 10.0 Description: This is the time after which an auto reset is attempted. Range: 0 2 Description: Analog output voltage can be configured as shown below: 0: Set frequency 1: Output frequency 2: Output current Analog voltage output Max voltage P.069 Sec P-67 Analog op max ref Min voltage P.070 Volts P-68 Analog op min ref Range: 0 500.00 Default value: Analog op max ref = 50.00 Analog op min ref = 0.50 Ref Min P.068 Frequency ref Ref Max P.067 P-69 P-70 P-71 Analog op max Analog op min DIO o/p config (Optional)* Range: 0.00 10.00V Default value: Analog op max = 10.00V Analog op min = 0.00V Description: This is the voltage at maximum input reference and voltage at minimum input reference... Voltage =.. x P.66 Range: 0 7 Default value: 1 Description: A relay output can be set as follows: P-71 Function 0 Drive fault condition 1 Run condition

14 P-72 P-73 DIO ton DIO toff 2 Set frequency 3 Desired frequency 4 Drive is ready to run 5 Direction reversal 6 Under voltage trip 7 Counter match Range: 0.000 60.000.000 Description: DIO output is set to 1 after a turn on delay. DIO output is set to 0 after a turn off delay. Sec P-74 Desired Frequency P-75 Counter match value Range: 0.0 500.0 Default value: 50.0 Description: This is the frequency at which the optional relay output is activated, if P-71 = 3. Range: 0 9999 Default value: 1000 Description: If counter value matches this parameter, optional output relay can be actuated if P71 = 7. Nos P-76 Motor Stator Resistance P-77 Reserved Range: 0.00 655.35 Default value: 1 Description: This is the stator resistance of the motor for use in auto torque function. This value is not required to be set as it is set internally based on motor nominal amps P-033. Internal stator resistance values are for 4pole, 50 motors. Ohms * Optional: An optional I/O card EC1_opt is required.