M-Bus Central Unit. Use

Similar documents
M-Bus Central Unit OZW10

Temperature Controller

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Non-communicating room controllers

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Extension module for lighting control

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Room Temperature Controllers

Heating Circuit Controller

Room Temperature Controller

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Heating Circuit Controller

Central Communication Unit OZW775

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

Plant Operating Software

Non-communicating room controllers

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Temperature controller Ducted systems

Immersion Temperature Sensors

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Room Temperature Controller

AEW Pulse Adapter. Building Technologies

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Universal Controller

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

PXR11 PXR12. System controllers DESIGO PX

Network nodes with gateway

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

AEW36.2. Pulse Adapter. Siemeca AMR

VAV compact controller KNX / PL-Link

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Communication module to connect M-bus devices to POL6xx.xxx controllers.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

AB Axis Industries. Use

7-day room temperature controller

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

SEH62.1. Digital Time Switch

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)

ERF910. RF Repeater. Synco living

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

VAV modular controller

Weekday / weekend room temperature controller

Power supply module, bus connection module

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Extension module for BACnet over Ethernet / IP and graphic Web functions

Room unit with PPS2 interface

Semi flush-mounted room temperature controllers with LCD

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

LPB/OpenTherm Gateway

C-Bus Pascal Automation Controller

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

7-day room temperature controller

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Status display unit with P-bus connection

Room unit with PPS2 interface

Extension module for graphic Web functions for one automation station

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Temperature Controller (Heat Pumps)

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Master room unit for RRV controllers

modunet292: novanet-ethernet interface

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

SoundwebTM. Installation Guide

Extension module for Web functions generic

Electrical Actuators

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Transponder card reader

VAV compact controller GDB181.1E/3 GLB181.1E/3

MC 11 EB-2 Power supply cabinet with external bus, AC version

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

PRU1... Use. Note. UNIGYR Universal Process Unit

Priva Blue ID Communication module RS232 SC22

Central communication unit with integrated web server function

ACS Plant Operating Software

Technical Information Fieldgate SFG500

TXM1.8RB. TX-I/O Blinds module

Junos WebApp Secure 5.0 Hardware Guide

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

ECL Comfort V a.c. and 24 V a.c.

Manual Industry Interfaces

Albatros 2 Grid supervision module / PSU User manual. AVS76.39x/309. Infrastructure & Cities. Edition 2.1

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Sauter Systems

Channel Switch CS. General Operating, Maintenance and Installation Manual

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

Transcription:

6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus connection facility to EN. Use The OZW central unit is a component of the M-bus system (refer to Data Sheet N6). It is designed for the remote supervision of community and district heating systems and for consumption cost billing in multifamily houses. The following types of M-bus devices can be connected: Metering devices: Heat meters SONOHEAT WR, WR, WR6, UH0 Heat meters SONOGYR energy Heat meters SONOGYR WSD Heat meters MEGATRON Water meters VOLUTRON Consumption meters via pulse adapter AEW., AEW0. Consumption meters via pulse adapter RELAY PadpulsM Electronic heat cost allocators MEMOTRON WHE Controllers: District heating controllers RVD Other types of M-bus devices on demand. CEN6en 6.06.009 Building Technologies

Functions The M-bus central unit detects the connected M-bus devices via its automatic search run makes possible the direct access to the M-bus devices through a PC, connected either directly or via modem monitors periodically the M-bus devices and potential-free digital inputs delivers alarms to a PC, either directly or via modem provides a clock function for alarms Type summary Type of device M-bus central unit Type reference or part no. OZW Terminal covers 008 0 When ordering, please give the type reference. The terminal covers must be ordered as separate items. Equipment combinations M-bus devices Software A maximum of M-bus devices can be connected directly to the M-bus central unit. Exception: A maximum of SONOHEAT heat meters with M-bus module up to V.06 A PC with the following software can be connected to the unit s RS- port, either directly or via modem: ACS plant operating software (refer to Data Sheet N60) Technical design Communication Telephone connection In the case of a connection via the telephone network, a Hayes-compatible modem is required at each side. 6Z09en PC mit ACS... Telephone network M-bus M-bus /8

Direct connection When using a direct connection, a null modem is required between M-bus central unit and PC. 6Z08en Null modem PC mit ACS... OZW M-bus Null modem 9-pin null modem cable 9-pin link cable Female Female Female Female Terminal Terminal Terminal Terminal TD TD TD TD RD RD RD RD RTS RTS RTS RTS CTS 8 8 CTS CTS 8 8 CTS DSR 6 6 DSR DSR 6 6 DSR GND GND GND GND DCD DCD DCD DCD DTR 6Z0 DTR DTR 6Z DTR Parameter settings The parameters of the M-bus central unit must be set with the help of a PC using the ACS plant operating software, connected either directly or via modem. Acquisition of M-bus devices Upon request, the M-bus central unit automatically searches for the M-bus devices used by the system. Supported are primary and secondary addressing and Baud rates of 00 and 00 Baud. Both the type of addressing and the Baud rates can be selected. The device list remains stored in non-volatile memory. Interrogation of M-bus devices The M-bus central unit offers a number of choices for interrogating the M-bus devices. Its parameters must be appropriately set. Manual interrogation cycle: The data will be interrogated via M-bus only when requested Periodic interrogation cycle: To ensure supervision of the devices, the data will be periodically and automatically interrogated hourly, daily, weekly or monthly. It should be noted that in the case of battery-powered M-bus devices, frequent interrogation will reduce battery life. If such devices are used by the system, no more than one interrogation per day should be made. For more detailed information, refer to the relevant product specification Alarm cycle: To ensure supervision, controllers can be interrogated more frequently. The alarm cycle can be set in one-minute steps. /8

Evaluation of consumption data Digital inputs Alarms The data are made available via the RS- port where they can be read out with the help of appropriate software, either directly or via modem. If a billing file is required, the M-bus central unit OZW0 can be used. The OZW has digital inputs for the connection of potential-free contacts. The operating action of the contacts (active closed or active open) can be parameterized. The M-bus central unit is able to detect the following types of faults: Signals delivered to the digital inputs Failures of M-bus devices Fault messages delivered by M-bus devices Failures of the M-bus central unit Fault status messages are delivered to a PC on which the ACS Alarm is installed. Rectification of a fault will not be signaled. Mechanical design Make up The M-bus central unit consists of base, housing and printed circuit board with the connection terminals (top: M-bus and digital inputs, bottom: mains connection). The unit also has LEDs, buttons, one RS- selector and one RS- socket. 0 66Z0 9 8 Modem reset button 6 Housing RS- socket LED for operation Connection terminals (M-bus and digital inputs) 8 LED for alarms M-bus button 9 Connection terminals (mains connection) Base 0 RS- selector Terminal covers Connection terminals LED for operation Terminal covers are available as an accessory item. They protect the terminals against physical contact and dirt. The terminal covers are mandatory when the unit is mounted outside the control panel or cabinet. In that case, the terminal cover on the mains voltage side must be secured with the cable ties provided. The LEDs are visible also when the terminal cover is fitted. The connection terminals are ready mounted. To avoid false wiring, the terminals for the mains voltage connection (AC 0 V) are clearly separated from the other terminals. The terminals are arranged such that, in normal situations, all incoming and outgoing wires can be connected without crossing. The green LED indicates the operational status of the M-bus central unit: LED lit: mains voltage present LED flashes: communication via M-bus and / or RS- port /8

LED for alarms RS- selector M-bus button Modem reset button The red LED shows the alarm status of the M-bus central unit: LED dark: no fault and no alarm LED lit: fault of one or several M-bus devices present LED flashes: internal fault of M-bus central unit or signal at the digital inputs This selector is used to select whether the M-bus central unit is connected to the RS- port via modem or directly to the PC. The M-bus button is used for starting the search run, thus creating the device list showing the number of M-bus devices on the list The modem reset button is used for re-initializing the modem. Then, the M-bus central unit will establish a connection to the control centre and deliver a status report. Engineering notes For detailed planning instructions on the M-bus system, refer to the Basic Documentation P6. The local regulations for electrical installations must be complied with. For additional notes on electrical installations, refer to data sheet N0. Mounting notes The M-bus central unit can be fitted in any position, either on a wall mounting rail or directly on the wall. Please observe: If there is no protection against electric shock hazard (e.g. in heating rooms, false ceilings or false floors), the use of terminal covers is mandatory. The terminal cover on the mains voltage side must be secured with cable ties If protection against electric shock hazard is ensured (e.g. in control panels or cabinets), the unit can be mounted without terminal covers The heat generated by the unit during operation must be allowed to escape. Adequate circulation of air must therefore be ensured Good accessibility for service staff must be ensured The local regulations for installations must be complied with Mounting Instructions are printed on the unit s packaging. Commissioning notes The M-bus central unit must be commissioned by authorized staff The Installation Instructions supplied with the unit contain detailed information on commissioning To set the parameters of the M-bus central unit, the ACS plant operating software is to be used. The parameters can be set either beforehand or on site. /8

Technical data General unit data Operating voltage AC 0 V ±0 % Nominal frequency 0 / 60 Hz Power consumption VA Digital inputs (P, P) for potential-free contacts Perm. ambient temperature Transport and storage +0 C Operation 0 0 C Perm. ambient humidity class F to IEC Weight 0. kg Reserve of clock h Norms and standards conformity to EMC directive 00/08/EC Low voltage directive 006/9/EC Electromagnetic compatibility Immunity EN 6000-6- Emissions EN 6000-6- Product standard EN 6090- Degrees of protection Without terminal covers IP 0 to EN 609 With terminal covers IP 0 to EN 609 Safety class II to EN 6090- M-bus master interface Norm EN Baud rates 00 / 00 Baud Number of devices that can be connected max. Cable length (copper, 0.6 mm dia.) max. 00 m RS- port Norm V. / EIA D Baud rate max. 9600 Baud Cable length max. m Connector 9-pin Sub-D, male Connection terminals P M P M CM+ CM- L N 6G0 CM+ M-bus connection + CM M-bus connection L, N Rated voltage AC 0 V M Ground for P, P P, P Digital inputs 6/8

Connection diagram L P M P P M P P M-BUS AC 0 V L N P M P M CM+ CM- N N 6A0 N M-bus central unit OZW P, P Devices with a potential-free contact output for delivering alarms P M-bus device (max. ) /8

Dimensions Without terminal covers, 90 0 6,9 6M0 With terminal covers 0,9 6 6M0, 0 6 Drilling template 00 6M0 Dimensions in mm 8/8 000-009 Siemens Switzerland Ltd Subject to alteration