Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Similar documents
Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

NEW! 6.5 Digit Precision Multimeter from Fluke

5502A Multi-Product Calibrator. Robust, transportable solution to match your workload and budget

Fluke Connect Modules Technical Data

Versatile, Automatic RCL Meters

Detailed Specifications 6 1/2 Digits High-Performance DMM

Fluke 729 Automatic Pressure Calibrator

5522A Multi-Product Calibrator

The 5700A/5720A High Performance Multifunction Calibrators. Taking Accuracy to a Whole New Level

Fluke 180 Series Digital Multimeters Features

Advanced Test Equipment Rentals ATEC (2832)

NEW. Programmable Resistance Decade Substituter. PRS-330 Page 1 of 5. IET LABS, INC. in the GenRad Tradition

1523/1524 Reference Thermometers

LOW WEIGHT, SMALL SIZE,

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

PRODUCT. Data Sheet. The new Fluke-289 Advanced Logging Multimeters with Trend Capture

350 Series AC/DC Clamp Meters

Keysight U2751A USB Modular Switch Matrix

Easy Steps to Integrate the 34405A Multimeter into a System

Mobile Communications DC Sources W

Data Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke

525A Temperature/ Pressure Calibrator

Fluke 3000 FC Series Test Tools Technical Data

Agilent L4433A Dual/Quad 4x8 Reed Matrix

2680 Series Data Acquisition Systems

8100 SERIES ADVANCED 8.5 / 7.5 DIGIT MULTIMETER. www. transmille.com

Field Metrology Wells

Precision Measurement, Low Noise, Programmable DC Power Supplies

Overview of Guildline s 6625A Resistance Measurement System

Ultra-Accurate Measurement for Temperature and Voltage

Contents. Fluke. Keeping your world up and running. See page 111 for a Product Quick Find List per model number

Reasons to connect your tools

Circuit Board Diagnostics and Test since 1976

SEE IT. SAVE IT. SHARE IT. All the facts, right in the field.

SEE IT. SAVE IT. SHARE IT. All the facts, right in the field.

Ultra-Accurate Measurement for Temperature and Voltage

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Programmable DC Power Supplies XLN Series

Ultra-Accurate Temperature Measurement Instruments

6220 Ethernet-Based Voltage Measurement Module

Temperature Measurement Instruments Ultra-Accurate... by Design

Multi-functional precision thermometer CTR3000

Agilent 34450A 5.5 Digit Bench Digital Multimeter. Turbo charge your measurements with one of the fastest throughput digital multimeter in its class

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Multi-Range Programmable DC Power Supplies 9115 Series

Technical Specifications May 2003

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

ATL55, AAC3, ATT29, ATT70, 9V Bat., AF38, AF39. Range Resolution Accuracy DC Current DM393 DM µA 0.1µA 1.0% % + 2

High-Temp PRT Module 2561

SEE IT. SAVE IT. SHARE IT. All the facts, right in the field.

40,000-Count Dual-Display Handheld LCR Meters Models 878B, 879B, and 880

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

1586A. Users Manual. SUPER-DAQ Precision Temperature Scanner

2020 System Calibrator

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

Models 6522, 6524, 6526, 6532, 6534 & 6536

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet

34970A 3499A/B/C. Advanced Test Equipment Rentals ATEC (2832) 34970A and 3499A/B/C Switch Systems

Data Acquisition Software and Hardware Demonstration Guide

VT04 and VT02 Visual IR Thermometers

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Single-Output 2000 W GPIB

Agilent E3640A E3649A Programmable DC Power Supplies

SourceMeter Airbag Test System

POWER QUALITY AND ENERGY TOOLS

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

Portable Multi-Function Calibrator Model CEP6000

Temperature Measurement and Calibration. Industrial Calibration Selection Guide. Multifunction Process Calibrator.

Thermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS

PQ ANALYZER PROCUREMENT SAMPLE SPECIFICATION

THURLBY THANDAR INSTRUMENTS. PL & PL-P Series. Laboratory Power Supplies. Standard and Programmable models, 35 watts to 240 watts

6220 Ethernet-Based Voltage Measurement Module

Precision measurement, low noise, programmable DC power supplies

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

Weight increments for deadweight testers

Agilent U2722A USB Modular Source Measure Unit. Data Sheet

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

LDC 3700B Series. Preliminary. The Standard for High-Performance Laser Diode Control. Laser Diode Controllers. Product Features

4-Channel Thermometer / Datalogger

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Data Acquisition Software and Hardware. Demonstration Guide. For: NetDAQ Logger, Hydra Logger, and Trend Link for Fluke V3.1

High Voltage Power Supplies

Precision Voltage Measurement. Instruments. Applications. Voltage Inputs. High-Stability, Low Drift Voltage References. Key Design Features

Specification for temperature sensor calibration setup

Modular Power System 1200 W per mainframe GPIB

Precision measurement, low noise, programmable DC power supplies

LDC 3700C Series. The Standard for High Performance Laser Diode Control. Laser Diode Controllers. Product Features

Model AccuBridge 6020T Thermometry Bridge

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MJÖLNER 600 Microhmmeter

SX 6000 Paperless Recorder

Agilent L4421A 40-Channel Armature Multiplexer

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

1660 Series Installation testing that protects appliances, wirelessly shares data

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Transcription:

Fluke 8845A/8846A Digital Multimeters Precision and versatility for bench or systems applications

Exceed your expectations With 14 measurement functions, math and analysis modes, the 8845A/8846A will meet the needs of any test, research and development, or service application. 2

for performance and value Features at a glance Handle even the most demanding measurements with high accuracy and 6.5 digit resolution. Use the built-in TrendPlot paperless chart recorder to graphically identify the extent of drift and intermittent events in analog circuits. View results in Histogram mode to reveal stability or noise problems in analog circuits. The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on the bench or in a system. These meters are both high performance and feature rich, yet also remarkably easy to use. These digital multimeters perform the functions you would expect to see in a multifunction DMM, including measuring volts, ohms, and amps. Basic V dc accuracy of up to 0.0024 %, 10 A current range, and a wide ohms range give you an unbeatable combination of measurement capability. You can also use the 8845A and 8846A to measure temperature, capacitance, period, and frequency the functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters utility even more with their graphical display modes, including Trendplot TM paperless recorder mode, statistics and histograms features you won t find on other multimeters. Of course, these meters are also durable and dependable, features you expect from any Fluke meter. This unique combination of features and performance makes the 8845A and 8846A an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service. 6.5 digit resolution Basic V dc accuracy of up to 0.0024 % Dual display 100 µa to 10 A current range, with up to 100 pa resolution Wide ohms ranges from 10 Ω to 1 GΩ with up to 10 µω resolution 2 x 4 ohms 4-wire measurement technique Measures frequency, capacitance, period, temperature (8846A) USB memory drive port (8846A) Fluke 45 and Agilent 34401A emulation Graphical display Trendplot TM paperless recorder mode, statistics, histogram CAT I 1000 V, CAT II 600 V 3

A perfect fit for many applications, Patented split terminal jacks enable 4-wire measurements with two leads Clear and bright dual display shows data in graphic or numeric formats Input terminals are located on the front and back of the meter to simplify connections within a system Context sensitive soft function keys make it easy to navigate through measurements and instrument settings 4

in a system or on the bench. Easy to integrate into your automated test system The 8845A and 8846A meters can be incorporated easily into your automated test system. These meters emulate several legacy bench DMMs, allowing them to be substituted easily into existing systems. SCPI compatibility and drivers allow them to work with most available application and development languages. Front and rear inputs let you easily make connections where it s most convenient, whether the meter is rack-mounted or used on a bench. Multiple interfaces provide compatibility to existing and new standards. Reading rates are greater than 1000 readings per second giving you the throughput you need for systems applications. Versatile solutions for advanced test applications These meters let you take test and troubleshooting to a new level. Set up the 8845A or 8846A to take measurements over a period of time and display them graphically on the DMM s screen, for real time trending analysis. Graphical trending analysis can highlight drift and signal fluctuations, as well as intermittent errors that can t be seen on a numerical display. Using the graphical display, the 8845A and 8846A can simultaneously display a histogram and multiple statistical values such as mean, min, max and standard deviation calculated using real time measurements. Analyzing a measured values distribution over time can highlight potential reoccurring out-of-tolerance problems. The ability to make dual simultaneous measurements and display them in graphic or numeric format adds new tools to the test system and design engineer s toolbox of tricks for solving or validating analog circuits. Save measurement results to USB memory and transfer the data to a PC for detailed analysis. Or use the Ethernet connection to transport data over a network. Extended current and ohms ranges and additional capabilities such as temperature and capacitance increase the variety of measurements you can make and tests you can perform with a single instrument. Perfect for benchtop research and development Research and development applications demand measurement performance and flexibility. The 8845A and 8846A meet these needs, with excellent performance in all measurement functions. It s easy to use and adapts easily to almost any benchtop application. USB port for flash memory devices (8846A) provides convenient data storage and transport Single button per function for ease of use 5

Dual display and versatile graphical capabilities The 8845A/8846A feature a unique dual display that allows you to measure two different parameters of the same signal from one test connection. To reveal signal quality issues like drift, intermittants and stability, view data as a real time trend plot or histogram, with the unique analyze mode. You won t find graphical display capabilities like these on any other instrument in this class. Perform 4-wire measurements with only two leads Patented split terminal jacks for the 2 x 4 ohms function allow you to perform 4-wire measurements using only two leads instead of four. A special test lead accessory is available to enable you to establish the connection. You get excellent resolution and accuracy plus the convenience and ease of using a single pair of leads. FlukeView Software and drivers add PC power and application compatibility. FlukeView Forms increases the power of your Fluke tool by enabling you to document, store and analyze individual readings or series of measurements, then convert them into professional-looking documents. Log live readings while connected to a PC or store, display and share readings in interactive forms, graphs and tables. Create customized, professional looking documents that can be printed or emailed. FlukeView Forms software includes easy-to-use standard forms. Instrument programming drivers, DLL files and support information are included to get your test system up and running as quickly as possible. FlukeView Forms Basic The Fluke 8845A/8846A ship with a free copy of FlukeView Basic. Transfer data points from your meter to your PC and use the two standard, noncustomizable forms to display your readings in table or graphical form. For a larger array of forms or to use FlukeView Forms Designer to customize your forms, upgrade to FlukeView Forms version 3.0 with FVF-UG. Fluke 45 and Agilent 34401A emulation The 8845A/8846A emulate operation and programming commands of the Fluke 45 and Agilent 34401. Emulation shortens the learning curve and makes it easy to fit the 8845A or 8846A into existing test systems. Fluke support completes the equation of value Like all Fluke products, the 8845A/8846A are built to provide years of dependable service. However, if you do need calibration or repairs, you can turn to our global network of direct and representative service centers strategically located around the world. Each offers a full range of support services. Multiple connectors give you maximum flexibility Choose from several interfaces to connect the 8845A/8846A to a personal computer: serial, IEEE-488, and Ethernet come standard on both models. A USB device port is included on the 8846A meter for convenient data transfer to and from a PC via a portable USB storage device. 6

With 6.5 digit performance, legacy DMM emulation and the latest interfaces, the 8845A/8846A will easily integrate into any legacy or new test system. 7

Summary specifications 8845A 8846A Display VFD Dot Matrix VFD Dot Matrix Resolution 6.5 Digits 6.5 Digits Measurement function Accuracy, ± (% of reading + % of range), one year after calibration V DC Ranges 100 mv to 1000 V 100 mv to 1000 V Maximum resolution 100 nv 100 nv Accuracy 0.0035 + 0.0005 0.0024 + 0.0005 V AC Ranges 100 mv to 750 V 100 mv to 1000 V Maximum resolution 100 nv 100 nv Accuracy 0.06 + 0.03 0.06 + 0.03 Frequency 3 Hz to 300 KHz 3 Hz to 300 KHz Resistance 2x4 Wire Yes Yes Ranges 100 Ω to 100 MΩ 10 Ω to 1 GΩ Maximum resolution 100 µω 10 µω Accuracy 0.010 + 0.001 0.010 + 0.001 A DC Ranges 100 µa to 10 A 100 µa to 10 A Maximum resolution 100 pa 100 pa Accuracy 0.050 + 0.005 0.050 + 0.005 A AC Ranges 10 ma to 10 A 100 µa to 10 A Maximum resolution 10 µa 100 pa Accuracy 0.10 + 0.04 0.10 + 0.04 Frequency 3 Hz to 10 khz 3 Hz to 10 khz Freq/period Ranges 3 Hz to 300 khz 3 Hz to 1 MHz Maximum resolution 1 µhz 1 µhz Accuracy 0.01 % 0.01 % Continuity/diode test Yes Yes Capacitance Ranges 1 nf to 0.1 F Maximum resolution 1 pf Accuracy 1 % Temperature Type Platinum RTD Range -200 C to +600 C Maximum resolution 0.01 Accuracy 0.06 Math functions Zero, Min/Max/Average, Std Dev; mx+b db/dbm Yes Yes Advanced functions Statistics/histogram Yes Trendplot Yes Limit test Yes Input output USB memory USB memory drive port Real time clock Yes Interfaces RS-232, IEE-488.2, Ethernet, USB (with optional adapter) Programming languages/modes SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 General Weight 3.6 kg (8.0 lb) Size (HxWxD) 88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in) Safety Designed to comply with IEC 61010-1 2000-1, ANSI/ISA-S82.01-1994, CAN/CSA-C22.2 No. 1010.1-92 CAT I 1000 V, CAT II 600 V Warranty Three-year Ordering information Models 8845A 6.5 digit precision multimeter, 35 ppm 8846A 6.5 digit precision multimeter, 24 ppm USB mem Options and accessories TL71 Test Lead Set, Premium DMM TL910 Precision Electronic Probe Set 884X-SHORT 4-Wire Short TL2X4W-PT 2x4 Wire Ohms Test Lead 2 mm Probe Tip 884X-RTD 100 Ohm RTD Temperature Probe 884X-512M USB Memory 512 M 884X-1G USB Memory 1 GB Y8022 IEEE488 cable (2 m) 884X-USB USB to RS232 cable adapter FVF-UG FlukeView Forms Software Upgrade No Cable Y8846 Rack Mount Kit Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2006-2014 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 7/2014 2547535C_EN Pub_ID: 11035-eng Rev 03 Modification of this document is not permitted without written permission from Fluke Calibration.