LASER PLUS OPERATING INSTRUCTIONS

Similar documents
LegacyPlus 7-OR SERIES RETURN TRANSMITTER INSTRUCTION MANUAL 7-OR-RT/xxx

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

Compact EGC Segmentable Node 115 V Mains Powered A90200

Ver. 1.0en.

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Cisco Compact EGC Segmentable Node A90200

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EOS-6000 Series Optical A/B Switch User Manual DC Version

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

SLD-mCS/sCS-series Miniature High Power Broadband Light Source Modules

Prisma II Platform. Optoelectronics

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ViaLite RF Splitter / Combiner

Operating Instruction for IQ Series laser diode module Instructions for IQ1C, IQ2C, IQ4C, IQ6, IQ7, IQ1A, IQ2A, IQ4A, IQ1H, IQ2H and IQ4H

Fiber Optic. Foreword. Special Tips:

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Model 3955 DFB 1550nm Laser in TO-can

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

S-Band Redundant LNA Systems

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

MV SERIES MACHINE VISION STROBOSCOPE. Operating Manual

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

Cisco Prisma II Platform

Multicom 1550nm High Power Erbium Doped Fiber Amplifier MUL 2RU EDFA 1550 XX xx

Master Oscillator Power Amplifier SLD System MOPA-SLD-850

Technical passport / EDFA nm Optical Amplifier EDFA-1550/24 (4 17)

FIBER PIGTAILED ULTRA STABLE LASER MODULE OZ-1000, OZ-2000 & OZ-3000 SERIES. Preliminary

TABLE OF CONTENTS 1. OVERVIEW... 1

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

DMC-1000 Chassis-Based Media Converter

EMC1600 Series Media Converter and Ethernet Extender Chassis

User s Manual. ASE-1019 ASE Light Source

Neets Switching Relay - 2. Installation manual

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

Optimux-34 Fiber Optic Multiplexer

IFL MICROWAVE PHOTONICS LINKS TO 30 GHZ

High-power 1550nm Fiber Amplifier Manual. Transmitter

EtherNodePlus Model OTEN-WC-01 Media and Wavelength Converter, SFP-SFP

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

ChromaFlex Chassis. Hardware Interface Manual

Instruction Manual Model Block Translator

MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Installation Job Aid for VSP 4850GTS

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

Medallion 7200 Series CATV Fiber Amplifier

OV-MCR116. Media Converter Chassis System. User s Manual

SLD-CS-series Compact High Power Broadband Light Source Modules.

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

RoHS COMPLIANT 2002/95/EC

PT-7728/7828 Quick Installation Guide

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

OR-862 / OR-862S Series optical receiver. Operation Manual

EDFA PON Port High-power 1550nm. XCOM series Fiber Amplifier Manual

RF0250 RF1100 RF1200 RF1300 RF1600

Installation Job Aid for Ethernet Routing Switch 5900 Series

Series 8000 RF Signal Switch Solution

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

4 Channel Contact Closure DIN Fiber Link System

Modular Block Converter Systems

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

Dell SC7020 Storage Controller Getting Started Guide

Optimux-34, Optimux-25

VDL-004. Miniature Manual Variable Optical Delay Line. User Guide

20W Tungsten-Halogen Light Source. Operation Manual

Mercury Manual No. IM-M1000 Rev G

OPERATOR MANUAL OSD8826 SERIES DIGITAL VIDEO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

Ultra Low Noise Laser 1550nm

Butterfly Laser Diode Mount

Power Supply and Fan Module Installation

PSW-002. Fiber Optic Polarization Switch. User Guide

Cisco CRS 16-Slot Chassis Power Systems

CATV EDFA Optical Amplifier 1550nm 24dBm. User Manual. L-RF-EDFA-24dBm

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996

PLD Series +5V Laser Diode Drivers

RoHS COMPLIANT 2002/95/EC

BIPOLAR OPERATIONAL POWER SUPPLY

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

FUJITSU COMPONENT LIMITED

USER MANUAL SES-FA4BAL

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

Wideband Photodiode Receivers

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

8 Channel Contact Closure DIN Fiber Link System

PCD 005 PolaMIX. Operation Manual

Transcription:

LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03

TABLE OF CONTENTS SYSTEM OVERVIEW Page 3 OPTICAL CONNECTORS & CLEANING Page 4 CHASSIS Page 4 STATUS MONITORING Page 4&5 POWER SUPPLIES Page 5 OPTICAL TRANSMITTER MODULE Fuse Page 5 RF Input Page 5 Optical Output Page 6 Input Drive vs. Channel Loading Page 6 Indicators and Test Points For LP-OT-6 Page 7 Indicators and Test Points For LP-OT-8 to LP-OT-15 Page 8 OPTICAL RECEIVER MODULE Description Page 9 Front Panel Page 9 Rear Panel Page 10 Internal Adjustments Page 10 Fuse Page 10 Optical Input Chart Page 10 RETURN FREQUENCY MULTIPLIERS Page 10 MODULE EXTRACTOR Page 11 025-370403 REV X9 Page 2 of 11

SAFETY WARNINGS LASER RADIATION The laser transmitters emit invisible radiation that can cause permanent eye damage. AVOID DIRECT EXPOSURE TO BEAM. Operate only with the proper optical fiber installed in the transmitter optical connector. The laser transmitter should be disabled with the front panel switch whenever the optical connector is empty. HIGH VOLTAGE The AC input power supply contains no user serviceable parts. There is exposed high voltage inside the supply. The power supply housing should be opened only by factory service technicians. FIRE HAZARD The AC input rear power supply fuse is a 3AG, 3.25A, slow blow fuse. To avoid a risk of fire, this fuse should be replaced only with an identically rated fuse. SHIPPING ALERT The main chassis is not intended as a shipping container. Shipping the system with any module installed can cause severe physical damage. SYSTEM OVERVIEW DESCRIPTION MODEL PART NUMBER MAIN CHASSIS LP-CH 037-000403 95-240VAC POWER SUPPLY LP-PS 037-000406 48VDC POWER SUPPLY LP-PS-48 037-000451 LASER TX MODULE 6dBm LP-OT-6 037-000400 LASER TX MODULE 8dBm LP-OT-8 037-080433 LASER TX MODULE 9dBm LP-OT-9 037-090433 LASER TX MODULE 10dBm LP-OT-10 037-100433 LASER TX MODULE 12dBm LP-OT-12 037-120433 LASER TX MODULE 14dBm LP-OT-14 037-140433 LASER TX MODULE 15dBm LP-OT-15 037-150433 TRIPLE RX MODULE LP-OR-300 037-000401 RSM 1&3 w/o OPTICAL RX LP-DC-212-NR 037-000454 RSM 1&3 w/ OPTICAL RX LP-DC-212 037-000447 RSM 2&4 (req. LP-DC-212) LP-DC-234 037-000448 SNMP STATUS INTERFACE LP-SNMP 037-000461 MODULE EXTRACTOR LP-EX 010-000930 A system can have a single power supply or 2 redundant supplies. With a single power supply, a fully populated system holds 15 RF/optical modules. With dual power supplies, a fully populated system holds 14 RF/optical modules. All modules can be hot swapped. 025-370403 REV X9 Page 3 of 11

OPTICAL CONNECTORS AND CLEANING The fiber ends can be damaged by the insertion of contaminated connectors. Some types of customer damage to connectors or fiber are not covered under warranty. Fiber connectors should never be left uncovered. Reel cleaners or prepackaged alcohol wipes are the most convenient means of cleaning optical connectors. Clean alcohol and lint free wipes or swabs may also be used. The standard optical connector is an SC/APC. To specify an FC/APC connector, append FA to the model name and consult the factory for part numbers. FC/APC connectors must be specified at time of order. CHASSIS The chassis is a 19 rack mount unit, 5.75 (3 RU) high. The chassis slots are numbered 1 to 16 from left to right as viewed from the front. When viewed from the rear, slot 1 is on the right. Slots 1-14 accept only RF/optical modules. Slot 16 accepts only a power supply module. Slot 15 accepts either an RF/optical module or a power supply module. All module changes can be made from the front of the chassis through service loops in the RF and power cables. All RF connections are made from the rear of the rack. All optical connections are made from the front of the rack. There are access holes in the front sides of the chassis for fiber routing. There are fiber support slots in the top front of the chassis. There are no connections or test points on the front of the chassis. The chassis status LED s are located on the power supply module. All LED s can be seen through a clear window in the front of the chassis. All normal indicators are green. Any red LED that is turned on denotes an abnormal condition. The chassis rear has 4 long-life fans that can be changed from the outside. The OT P/N for the fan assembly is 037-000405. There is a DB-25M alarm connector at the center rear of the chassis. These isolated relay contacts, rated at 100mA @ 25VDC, provide a ground closure on any alarm, including power failure. Pins 1-15 monitor slots 1-15 respectively. Pin 17 is the chassis cooling alarm. Pin 24 is the summary alarm that alarms on any failure. Pin 25 is ground. The small rectangular connector at the right rear of the chassis is for factory testing, the Olson Technology SNMP interface (LP-SNMP), or OEM status monitoring modules. STATUS MONITORING There are three types of status links built into this system. 1) The rear panel DB25 connector provides isolated summary alarms of each module in the system. No computer is required. 2) The 10 pin connector located in the upper right rear of the main chassis, can be adapted to the printer (parallel) port of any windows 95 or 98 (ME, 2k, and XP will not work) based computer to monitor several critical module and chassis functions. This software is available from Olson Technology Inc. 3) The 10 pin connector will accept an OT-SNMP SNMP interface. One interface is required per chassis. Please consult the factory for complete details on these features. 025-370403 REV X9 Page 4 of 11

There are 3 LED s on the front of the power supply. The temperature alarm LED is normally green. It changes to red if any fan is open, missing, or frozen. It also goes red if the unit s internal temperature is too high. This LED is normally on for several seconds after power on while the fans start up. The red summary alarm LED is normally off. It lights on any module alarm or on a temperature alarm. The power LED is normally green. If the power supply voltage is too high or too low, it will be red. This will also cause a temperature alarm. The test points can be used to monitor the bus voltage. POWER SUPPLIES A single power supply mounts in the rightmost slot as viewed from the front. Dual supplies mount in the two rightmost slots. Changing from single to dual supplies does not require any chassis rewiring. The AC supply automatically accepts 90-132VAC and 180-264VAC at 47-63Hz. The maximum input power is about 140 watts. The voltage supplied to the modules is approximately 5.25VDC. The AC input is through an IEC connector on the rear of the power supply. The voltage selection jumper is not used; the unit will operate with the jumper in any position. If redundant supplies are used, we recommend plugging them into independently protected power strips. The Laser Plus system also has a 48V DC input power supply for central office use. See the LP-PS-48V instruction manual, OT p/n 025-370451, for complete specifications. OPTICAL TRANSMITTER MODULE FUSE The module has an internal miniature 3A SB fuse in a holder. The Littelfuse part number is 0454003. The Olson Technology P/N is 286-000009. RF INPUT The LP-OT-6 laser transmitter accepts a 77 channel flat RF input from +18dBmV to +22dBmV per channel (50-550 MHz). Digital signals can be added from 550MHz to 870MHz. The power in any 6MHz bandwidth should be at least 6dB below the picture carriers. The LP-OT-8 to LP-OT-15 laser transmitter accepts a 77 channel flat RF input from +19dBmV to +23dBmv per channel (50-550 MHz). Digital signals can be added from 550MHz to 870MHz. The power in any 6MHz bandwidth should be at least 6dB below the picture carriers. The front panel RF test point has been calibrated at 547.25MHz to read +10dBmV for optimum optical modulation with 83 channel loading. This level will change with channel loading. With these frequency ranges, it is extremely important to account for coax cable loss and slope when making measurements and distributing signals. 025-370403 REV X9 Page 5 of 11

OPTICAL OUTPUT The cooled DFB laser outputs 4mW (+6dBm) minimum at 1310 nm. Laser performance has been optimized for this power level; there is no external adjustment for laser output power. UNIT OPTICAL OUTPUT LP-OT-6 4.00mW 6dBm LP-OT-9 7.94mW 9dBm LP-OT-8 6.30mW 8dBm LP-OT-10 10.0mW 10dBm LP-OT-12 15.70mW 12dBm LP-OT-14 25.00mW 14dBm LP-OT-15 31.60mW 15dBm INPUT DRIVE vs. CHANNEL LOADING The laser RF drive level is the primary determining factor of link distortion and S/N performance. The basic limitation on input drive is total input power. The following chart shows the approximate input levels versus channel loading. The left axis shows the nominal RF input level. The unit will work with levels within +/- 2dB of this value. The right axis shows the test point reading for optimum modulation. Many systems run their digital channels at 6dB below the analog channels. This is a very convenient level for calculating loading. At 6dB down, merely divide the number of digital channels by 4 and add to the analog channels to get the total loading. The factory test input is 77 analog channels with 42 digital channels at 6dB down. This is 77 + 42/4, which equals 87.5. This is the 87.5 ch / +20dBmV input point on the graph. Some systems use an OMI meter to set laser modulation. The LP-OT-6 to LP-OT-15 have been individually adjusted for optimum performance. Setting all units for the same OMI, instead of using the test point, will result in reduced transmitter performance. Input Level versus Loading 29.0 19 27.0 17 Nominal Input Level dbmv 25.0 23.0 21.0 19.0 15 13 11 9 Set T.P. dbmv 17.0 7 15.0 5 10 20 30 40 50 60 70 80 90 100 # of Channels 025-370403 REV X9 Page 6 of 11

If the channel loading is less than 40, you may decide not to increase the levels by the maximum possible amount. This will provide improved distortion at the cost of S/N. The best rule of thumb is to use the maximum possible levels for long haul links, and lower drive levels as the links get shorter. INDICATORS AND TEST POINTS FOR LP-OT-6 The laser transmitter has front panel test points for optical power and laser current. Only a high impedance voltmeter should be used. The meter common should be connected to the module ground test point, not to chassis ground. The optical power alarm LED is normally green. It turns red on insufficient optical power. 4mW of optical output reads 4.0V at TP. The laser current alarm LED is normally green. It turns red on excessive laser current. At a typical laser current of 30mA the TP will read 0.6V. The cooler alarm LED is normally green. It turns red when the cooler cannot keep the laser at a constant temperature. The RF level adjust control allows for a 4dB range of input level adjustment. The RF test point is calibrated to read +10dBmV @ 547.25MHz for proper laser modulation with 83 channel loading. This level will change with channel loading. It does not require termination. Push the laser enable switch with an alignment tool to enable or disable the laser. The laser should be disabled whenever there is no fiber connected. Disabling the laser will cause a local optical power alarm, but will not cause a remote module or chassis alarm. Teasing this switch may cause very brief remote alarms. The optical output connector is type SC/APC, with optional FC/APC connector available. NOTE: The Laser Enable switch is no longer available on newer models. 025-370403 REV X9 Page 7 of 11

INDICATORS AND TEST POINTS FOR LP-OT-8 TO LP-OT-15 The laser transmitter has front panel test points for optical power and laser current. Only a high impedance voltmeter should be used. The meter common should be connected to the module ground test point, not to chassis ground. The optical power alarm LED is normally green. It turns red on insufficient optical power. Optical ouput reads as shown below: UNIT OUTPUT TEST POINT VOLTAGE LP-OT-8 6.30mW 0.63V LP-OT-9 7.94mW 0.79V LP-OT-10 10.00mW 1.00V LP-OT-12 15.70mW 1.57V LP-OT-14 25.00mW 2.5V LP-OT-15 31.20mW 3.12V The laser current alarm LED is normally green. It turns red on excessive laser current. At a typical laser current of 50mA the TP will read 1.0V. The cooler alarm LED is normally green. It turns red when the cooler cannot keep the laser at a constant temperature. The RF level adjust control allows for a 4dB range of input level adjustment. The RF test point is calibrated to read +10dBmV @ 547.25MHz for proper laser modulation with 83 channel loading. This level will change with channel loading. It does not require termination. Push the laser enable switch with an alignment tool to enable or disable the laser. The laser should be disabled whenever there is no fiber connected. Disabling the laser will cause a local optical power alarm, but will not cause a remote module or chassis alarm. Teasing this switch may cause very brief remote alarms. The optical output connector is type SC/APC, with optional FC/APC connector available. NOTE: The Laser Enable switch is no longer available on newer models. 025-370403 REV X9 Page 8 of 11

OPTICAL RECEIVER MODULE DESCRIPTION The LP-OR is a triple return band receiver in a single module. The receivers have an extended bandwidth of 200 MHz to allow the use of spectrum multiplication. Individual receivers in the module can be disabled if three inputs are not available. FRONT PANEL The 3 rectangular red/green status LED s monitor the receivers optical inputs. They are normally green and change to red on a low or missing optical input. Any red LED causes a module alarm and a chassis summary alarm. The 3 DC test points monitor the receivers optical inputs. 1mW (0dBm) is 1V at the test point. Only high impedance meters should be used. Use the ground test point at the bottom of the module, not chassis ground. The 3 multi-turn potentiometers set the receivers gains. Setting any gain control fully counter-clockwise will disable that receiver. The LED for a disabled receiver will always be green. A disabled receiver will never generate an alarm. The 20dB RF test point monitors the RF output of any single receiver. It does not require termination. The 3 position toggle switch selects which receiver s output appears at the test point. Insure that this switch is in the correct position before using the test point to set the RF gain. levels. The ground test point should be used when checking optical input The SC/APC optical input connectors are on the right of the front panel, with optional FC/APC connectors available. 025-370403 REV X9 Page 9 of 11

REAR PANEL The RF output connectors are on the rear of the unit. Receiver #1 is on the top. Receiver #3 is on the bottom. INTERNAL ADJUSTMENTS There are 3 jumpers that are accessible from the side that are used to set the receiver input range. The jumpers can be changed with tweezers or needle nosed pliers. The nominal level for changing jumper posistions is -3dBm. FUSE The module has an internal miniature 3A SB fuse in a holder. The Littelfuse part number is 0454003. The Olson Technology P/N is 286-000009. OPTICAL INPUT CHART The following chart shows the test point readings versus optical input levels. T.P. Volts Optical Input mw Optical Input dbm 3.02 3.02 4.8 2.51 2.51 4 2.00 2.00 3 1.58 1.58 2 1.26 1.26 1 1.00 1.00 0 0.79 0.79-1 0.63 0.63-2 0.50 0.50-3 0.40 0.40-4 0.32 0.32-5 0.25 0.25-6 0.20 0.20-7 0.16 0.16-8 0.13 0.13-9 0.10 0.10-10 0.08 0.08-11 0.06 0.06-12 0.05 0.05-13 0.04 0.04-14 0.03 0.03-15 RETURN FREQUENCY MULTIPLIERS The Laser Plus system includes 3 receiver/ down converter modules that can be used as part of a return band frequency multiplier system. This system can quadruple the bandwidth of a new or existing return link. Olson Technology builds up converters to fit inside the nodes of several manufacturers. Consult the factory for the latest list of compatible nodes. See the LPDC-212 / LPDC-234 instruction manual, OT # 025-370447, for more details. 025-370403 REV X9 Page 10 of 11

Laser Plus Module Extraction Tool Insert module puller and slide the notched end underneath the pull tab on the front of the inserted module as shown above. Then press down on the handle, this will lift the notched end thereby lifting the front of the module. Then proceed by pulling the unit out while pressing down on the handle. 025-370403 REV X9 Page 11 of 11