Switch Protection Module

Similar documents
Return Path Analog CATV Detector Modules. EPM 705 Series

WaveReady. Optical Link Monitoring System: BrightJack 200ER

600 mw Fiber Bragg Grating Stabilized 14xx nm Pump Modules with Ultra-Low Power Consumption. S35 Series

Up to 200 mw Uncooled 980 nm Pump Modules. TO T13 Series

Standard-Area Silicon PIN Photodiodes (500µm)

SLD Drive SLD. Board FC/APC Connector. TEC Control. Board. Control Circuits. Control interface DB9 (Female)

PSW-002. Fiber Optic Polarization Switch. User Guide

Single Stage Isolator

Dual Stage Isolator. 1.Description:

LightBend TM Dual 2x2 Bypass Multimode Fiberoptic Switch

Detectors for Fiber Optics: InGaAs PIN Photodiodes

WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B

EMBED2000+ Data Sheet

WaveReady WRT-882. Dual 10 G Tunable Transponder

LT900SERIES. 1xN Multi-Channel Switch Operation Manual

Helium-Neon Laser Heads Series

Product Specification DataSheet

Power Supply Options for Helium-Neon Lasers

Wideband Photodiode Receivers

Power Supply Options for Helium-Neon Lasers

USB-1616FS. Analog Input and Digital I/O. Specifications

Model 3955 DFB 1550nm Laser in TO-can

Specification for Dispersion Slope Compensating Module for SMF Transmission Fiber SMF-DK

FSXpert Optical AB Protection Switch

Specifications USB-1616FS

Product Specification. 10Gbps 2KM XFP Transceiver PLXFP1310GLR02

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

DIGITAL DIRECTIONAL INLINE OPTICAL POWER MONITOR/METER

Mb/s ATM Multi-mode Dual Transmitter

Optimux-34 Fiber Optic Multiplexer

Specification for Dispersion Slope Compensating Module for LEAF Transmission Fiber LEAF-DK

PTC-101-M12 Hardware Installation Guide

TECHNICAL SPECIFICATIONS. Planar Optical Splitter Module

Optimux-108, Optimux-106

FOMi-40 Fiber Optic Modem with Remote Management

PLC Splitter, Module/Cassette Type, LIIN25 Features

Specification for Dispersion Slope Compensating Module for TW-RS Transmission Fiber in the C-band TWRS-DK

LASERS FOR ANALYTICAL INSTRUMENTATION

2Mbps 850nm MMF SFP Transceiver 2km HOLS-P1850-LD-CV-B

GP-XFP-1L-LEG. 10Gbs XFP Transceiver

FAP 600 Series. Highest quality fiber-coupled diode laser bars in the industry.

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

10G SFP + Bi-di Transceiver Hot Pluggable, single LC, 1270nm/1330nm, DFB LD, Single Mode, 20km PSFP F/PSFP F

Optimux-34, Optimux-25

Planar Lightwave Circuit (PLC) Splitter, 1x4, 1x8, 1x12 and 1x16 Configurations in PEACOC Flexible Tray

Optimux-4T1 Four-Channel T1 Multiplexer

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

Hardened Web-Smart High Power PoE Ethernet Switch

High Power Uncooled mbtf 980nm Pump Laser Module. Applications

PC-CARD-DAS16/12 Specifications

Power over Fiber Technical Note

New Terminal Amplifier. Whitebox

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

High Power Uncooled mini-btf 980nm Pump Laser Module LU96***E-10R

PC-CARD-DAS16/16 Specifications

LASERS FOR ANALYTICAL INSTRUMENTATION

Uncooled mini-dil 980nm Pump Laser Module. Applications

FTBx-1750/OHS-1700 KEY FEATURES RELATED PRODUCTS AND ACCESSORIES SPEC SHEET HIGH-PERFORMANCE POWER METER AND OPTICAL HEAD SERIES

PCD 005 PolaMIX. Operation Manual

Parameter Symbol Min. Typical Max. Unit Storage Temperature T S C Supply Voltage V CC T, R V Relative Humidity RH 0 85 %

LightMUX. Passive Optical Networking

LATCHING FIBER OPTIC 1xN SWITCHES

PLC SPLITTER PRODUCTS

ICF-1150 Series Quick Installation Guide

PureGain PG1600P. Data Sheet. Fixed Gain, Compact EDFA with Digital Control Electronics. Contents: Features:

TCF-142-RM Series Hardware Installation Guide

GEPON OLT PX20++ Optical Module CLEPONOLTPX20++

Data Sheet. QFBR-S01IN001Z Optical Phase Interrogator. Description. Features. Applications

40GBase QSFP+ PSM4 1.5km Optical Transceiver

Copyright Black Box Corporation. All rights reserved.

2x2 Optical Protection Switch

XFP 10G Transceiver M10GB-XFP-BIDI40

SHFP-2G-B Gb/s BiDi SFP Transceiver Hot Pluggable, Simplex LC/SC, +3.3V, Single mode, 20km, 0~70 C 1310/1550nm or 1310/1490nm DFB/PIN

TCF-142 Quick Installation Guide

GEPON OLT Optical Module

WA OPTICAL SWITCHES (AWAP)

A block diagram of the HXFP-XDX1XX XFP optical transceiver is shown below

Viking Series 10x1000Base-T + 2x10GBase-SR Ports, MIL-DTL-38999, Unmanaged Ethernet Switch, 28VDC

FIBER OPTIC 1xN SWITCH coaxial design

RoHS COMPLIANT 2002/95/EC

Diamond FLQ-Series. Q-Switched Fiber Lasers FEATURES & BENEFITS

FEATURES. APPLICATIONS Machine Vision Embedded Instrumentation Motion Control Traffic Monitoring Security

10Gb/s 850nm Multimode SFP+ Optical Transceivers BPS8503CG-SR

Technical Data Sheet Photolink- Fiber Optic Receiver

SHPP-10G-LR. 10Gb/s SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 1310nm DFB/PIN, Single mode, 10km

ICF-1150 Series Quick Installation Guide

Industrial PoE Media Converter

Fiber optic Switch. eol 1x2 1x4 2x2. eol 1x8 1x12 1x16 OPERATION MANUAL

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1550nm, Single Mode, 80km, EML & APD Optical Transceiver PSFP SF

QFBR-S01IN001Z. Optical Phase Interrogator. Data Sheet. Description. Features. Applications

SHFP-GE-B Gb/s BiDi SFP Transceiver Hot Pluggable, Simplex LC/SC, +3.3V, Single mode, 80km, 0~70 C 1490/1550nm DFB/PIN

Ethernet OptoLock EDL300T

Features and Benefits. Certifications

Micro or MSA Gain Block

Features and Benefits. Certifications

DS1217M Nonvolatile Read/Write Cartridge

SHFP-GE-EX. 1.25Gb/s SFP Transceiver Hot Pluggable, Duplex LC, +3.3V, 1550nm DFB/PIN, Single mode, 40km, 0~70 C

USB-1602HS-2AO Specifications

Ver. 1.0en.

Transcription:

www.lumentum.com Data Sheet

The Lumentum switch protection module offers quick protection and restoration to prevent data loss due to cable failure, port failure, or catastrophic failures. An optical signal is split into diversely routed fibers. When a failure occurs, a 1x2 switch in the module selects the optical signal from the backup fiber. This physical layer solution is able to isolate failures with a faster recovery time and simpler implementation compared to other protection solutions. It can be directly mounted on printed circuit boards. The solution is also Telcordia qualified for maximum reliability. Various packages and protection mechanisms are available upon request. Key Features Low insertion loss Fast switching time Protocol and bit-rate independent Built-in monitors Applications Protecting and restoring optical communication networks Increasing reliability in the optical physical layer Compliance Telcordia GR-1312-CORE qualified www.lumentum.com 2

Functional Diagram Output 1 Input 1 Tap Tap (50/50 ) Output 2 PD1 Tap Input 2 Output 3 1X2 Switch PD2 Tap Input 3 PD3 Dimensions Diagram (Specifications in mm unless otherwise noted.) A (3 : 1) 22.5 22.5 16.0 4XM3 6 TMM-110-01-G-D 0.5 3.7 12.0 20 19 A 2 1 63.0 70.0 25.0 2.5 4.0 83.0 90.0 11.8 www.lumentum.com 3

Pinout Pin# Signal name Type I/O Description 1 +5VDC Power Power supply 2 AGND Power Analog ground 3 A1 Input Switch electrical drive 4 NA Not applicable 5 B1 Output Switch status 6 NA Not applicable 7 AGND Power Analog ground 8 AGND Power Analog ground 9 PD1_OUTPUT Output PD 1 analog output 10 PD2_OUTPUT Output PD 2 analog output 11 PD3_OUTPUT Output PD 3 analog output 12 NA Not applicable 13 NA Not applicable 14 NA Not applicable 15 I2C_SCL Input EEPROM I2C serial clock 16 I2C_SDA Input/Output EEPROM I2C serial data 17 I2C_WP Input EEPROM write protection 18 ID Output Module identify pin 19 DGND Power Digital ground 20 DGND Power Digital ground Control Signal Correspond to Switch Status Control Signals (A1) Status Signals (B1) Optical Path Configuration 0 0 Input 2 to Output 3 1 1 Input 3 to Output 3 EEPROM Data Map Address Description Length (Bytes) Value Data Type 0x0000 Vendor ID 5 Lumentum String 0x0005 Product P/N 10 String 0x000F Catalog number 20 String 0x0023 Serial number 20 String 0x0037 Spec rev 5 002 String 0x003C Manufacture date 10 YYMMDD String Note: 1. There is semicolon at the end of each information. 2. Fill with 0xFF in the spare bytes. www.lumentum.com 4

Specifications Parameter Condition Specification Optical Wavelength range Wavelength span #1 Wavelength span #2 Insertion loss 1,2 Input 1 to Outputs 1 & 2 Inputs 2 & 3 to Output 3 1510 to 1610 nm 1270 to 1350 nm 3.8 db 1.2 db Polarization dependent loss 0.2 db Wavelength dependent loss To the wavelength span #1 and #2 respectively Switching time 3 5 ms Switch cross talk 55 db PD tap ratio 4 All paths Typical 2% Return loss 45 db Switch type 5 Electrical Switching voltage Switching current 0.5 db Latching 4.5 V 5.5 V 18 ma 32 ma Switching pulse width 20 ms Tap monitor responsivity Relative to the input optical power which in range of 23 dbm to +23 dbm Typical PD Output voltage at 0 dbm Typical 1.8 V Switch status out voltage Input 3 on Input 2 on PD dark current 6 1 na Mechanical Dimensions 40 mv/db 4.75 V 5.25 V 0 V 0.5 V 90.0 x 70.0 x 16.0 mm Fiber type All ports Corning SMF 28 or equivalent with 900 µm tight buffer 1. Excluding connectors. Add 0.2 db for each connector. 2. Insertion loss is defined over whole operating wavelength range, temperature range and all polarization states. 3. The switching time is defined as the period starting from 90% of the rising edge of the electrical trigger pulse, ending at 90% of the steady state optical power level of the rising edge at output port, as measurement from an oscilloscope with adequate bandwidth. 4. This parameter is only for information, isn t tested. 5. When there is a power failure to the optical switch, the switch should retain the switching state with no change in insertion loss. 6. Guaranteed by design www.lumentum.com 5

Absolute Rating 1 Parameter Specification Operating case temperature range 5 to 70 C Transport and storage case temperature range 40 to 85 C Operating relative humidity (non-condensing) 2 5 to 85% Transport and storage relative humidity 5 to 90% Optical input power 27.0 dbm Electrical power consumption under normal operating conditions 2W 1. The device must not show any degradation after the following conditions have been applied for short term. Short term is defined as less than 96 consecutive hours and less than a total of 15 days over a one year period. 2. The relative humidity for short-term limits is 5 to 90%, but not to exceed 0.024 kg water / kg of dry air. Ordering Information For more information on this or other products and their availability, please contact your local Lumentum account manager or Lumentum directly at customer.service@lumentum.com. SPM-00000 Code Fiber Length 1 1 1 meter 2 2 meters Note: 1. Tolerance is ±0.1 m. Code Connector Type 0 No connectors 1 FC/PC 2 FC/APC 3 SC/PC 4 SC/APC 5 LC/PC 6 MU Telcordia is a registered trademark of Telcordia Technologies Incorporated. North America Toll Free: 844 810 LITE (5483) Outside North America Toll Free: 800 000 LITE (5483) China Toll Free: 400 120 LITE (5483) 2015 Lumentum Operations LLC Product specifications and descriptions in this document are subject to change without notice. www.lumentum.com spmswitch-ds-cc-ae 30149062 903 0108