Wall Mounted Building Entrance Enclosure Instructions

Similar documents
SD Splicing Cassette

with Fiber Management Bar

M204SMB Surface Mount Box Instructions

Mini Wall-mount Building Terminal (WBM)

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

Pretium Rack-mountable 1U Housing Hardware

HD Flex Zero RU Cassette Holder and Bracket

SYSTIMAX 360 Evolve Modular Panel Installation Instructions

Cable Routing Procedures for Dell PowerEdge R630 Systems

ReadyTM Fiber Solution

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

OptiSheath Advantage Sealed 4-, 6-, 8- and 12-Port Multiport Terminals

Model GS7000 Node Expanded Fiber Tray Installation Instructions

FL1000 Wall-Mount Box Installation and Operation Guide

Print Mechanism Maintenance Kit

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Cable Routing Procedures for Dell PowerEdge T710 Systems

3 Angled Connector Housing (MC) Installation

Assembly and Setup Manual

Fiber Management Tray (FMT) User Manual

FIBRE ENCLOSURES AND SPLICING ACCESSORIES

E1135C PDU and Pod Upgrade Procedure

10.0 Enclosures Enclosures. Integrated Routing Connectorised Fibre Enclosure 143. Integrated Routing Fibre Enclosure 144. Integrated Routing 145

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Fibre Enlosures and Splicing

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

INSTALLATION INSTRUCTIONS

3 Maintenance. Chapter contents

Charging Cabinet Owner s Manual

High Density PEACOC v. 3.0 Fiber Patch Panel& FleT

Rack Mount Interconnect Center (RIC3)

The FTR series interconnection trays are an economical way to manage fiber terminations and

CommScope standard density fiber optic panels. High-performance communication solutions

FiberExpress Brilliance Connectors

INFINIUM TM HD FIBER ENCLOSURE

imac Intel 27" EMC 2429 SSD Dual Drive

SYSTIMAX imvision impower Power Extender Installation

Encore XT Manual Gun Upgrade Kit

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

Zebra XiII-Series Printer Quick Reference Guide

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

LegacyPlus 7-OR SERIES RETURN TRANSMITTER INSTRUCTION MANUAL 7-OR-RT/xxx

Product Data Sheet. SC Thead-Lock Connector Assembly Instructions. Page 1 of 5 QUALITY FIBER COMPONENTS, EQUIPMENT, & SUPPLIES

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Installation Job Aid for Ethernet Routing Switch 5900 Series

7403 K321. Display Wall Mount. Kit Instructions. Issue A

JUN 2016 Rev B

Compact Series Wallmount Enclosures

Module Connectors and Cable Specifications

Ruger SR22. Operator s Manual RUGER SR22 SR9C SR40C 9E LMS-RMSR

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

ARIADROP: Fiber to the MDU (FTTM)

Gigabit 1000Base-T to 1000Base- SX/LX Converter

Installing imac Intel 27" EMC 2390 Dual HDD or

MacBook Unibody Model A1278 SSD Dual Drive

Fiber Optic System. Fiber Optic System. Fiber Optic Rack Mount Solutions

FIBRE OPTIC ENCLOSURES SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

DirectCommand Installation RoGator Model Year Ag Leader Technology

Peel/Rewind Upgrade Kit

FOSC 400 Closures and Accessories 2015 ORDERING GUIDE 1ST EDITION

Next Generation Frame Fiber Termination Block With MPO Connectors (FTB w/mpo) User Manual

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Traverse Hardware Installation and Commissioning Guide

Replacement Instructions

Rear Consumer LCD Hinge Assembly Large Displays

Ag Leader Technology. DirectCommand Installation RoGator Model Years

F I B E R S O L U T I O N S

Installation Instructions

Removing and Replacing Chassis Components

LSX Optical Distribution Frame

imac Intel 20" EMC 2266 Optical Drive

NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels

8~14-Port Managed Ethernet Switch

Sheath Removal of 3456-Fiber RocketRibbon Extreme-Density Cable

QUICK REFERENCE. Using the Battery

LASERJET ENTERPRISE M604, M605, M606

Description and Assembly Instructions

Uniprise Structured Cabling Solutions Guide

3M Passive Optical Splitter Shelves and Modules

CENTRO 6451/6452 LIFT DESK

INDUSTRIAL POE SWITCH

Next Generation Frame - Black (NGFB) Optical Distribution Frame Solution

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

SEQUEL 6051/6052 LIFT DESK

THE SOURCE FOR FIBEROPTIC PRODUCTS

Wall Mount Kits. To check which phone model you have, press Applications number field shows your phone model. and select Phone information.

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Installing a Power over Ethernet injector

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

G12/G12x USER S MANUAL

3M Fiber Distribution Units 8400 Series

Eaton LCD Lift Flat Panel Display System. Installation Guide

Rack Mount Enclosures. Fibre Optic Rack Mount Enclosure: SLIDING. Features. Application. Technical Specifications. Asia Pacific EMEA Americas

CommScope and Cisco - The ideal connectivity system for multilayer directors

Transcription:

Instruction Sheet 860383587 Issue 8, February 2014 Wall Mounted Building Entrance Enclosure Instructions General The CommScope wall mounted building entrance enclosures are designed to enable field and factory terminations, and field splicing in a single unit. Units can accommodate up to 96 ST or SC, and 192 LC or keyed LC fiber terminations or 16, 32, and 64 MPO adapters. The enclosure also stores fiber splices and can accommodate 96 fusion splices or 72 mechanical splices with the appropriate splice holders. The overall dimensions are 11 inches high x 13 inches wide x 2.5, 4.3, or 6 inches deep (279mm high x 330mm wide x 64mm, 108mm, or 152mm deep). Dimensions for the 1P enclosure are 5.125 inches high x 6.10 inches wide x 1.7 inches deep (130mm high x 155mm wide x 43mm deep). Ordering information is listed below: Material ID Part No. Description 760172288 WBE-EMT-BK/1P-PNL 1P enclosure, black, accepts ReadyPATCH module and panel 760147496 WBE-EMT-BK/2P-PNL 2P enclosure, black, accepts ReadyPATCH modules and panels 760147520 WBE-EMT-WH/2P-PNL 2P enclosure, white, accepts ReadyPATCH modules and panels 760147504 WBE-EMT-BK/4P-PNL 4P enclosure, black, accepts ReadyPATCH modules and panels 760147538 WBE-EMT-WH/4P-PNL 4P enclosure, white, accepts ReadyPATCH modules and panels 760147512 WBE-EMT-BK/8P-PNL 8P enclosure, black, accepts ReadyPATCH modules and panels 760147546 WBE-EMT-WH/8P-PNL 8P enclosure, white, accepts ReadyPATCH modules and panels 760164616 WBE-EMT-BK/2P-MOD 2P enclosure, black, accepts InstaPATCH 360 modules and panels 760164632 WBE-EMT-WH/2P-MOD 2P enclosure, white, accepts InstaPATCH 360 modules and panels 760060426 WBE-EMT-BK/4P-MOD 4P enclosure, black, accepts InstaPATCH 360 modules and panels 760164640 WBE-EMT-WH/4P-MOD 4P enclosure, white, accepts InstaPATCH 360 modules and panels 760164624 WBE-EMT-BK/8P-MOD 8P enclosure, black, accepts InstaPATCH 360 modules and panels 760164657 WBE-EMT-WH/8P-MOD 8P enclosure, white, accepts InstaPATCH 360 modules and panels WBE-EMT-BK/2P WBE-EMT-BK/4P WBE-EMT-BK/8P WBE-EMT-BK/1P 2014 CommScope, Inc. All rights reserved Page 1 of 10

860383587 Instruction Sheet How to Contact Us To find out more about CommScope products, visit us on the web at http:/// For technical assistance: Tools Required - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or Authorized Business Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795. Outside the United States, contact your local account representative or Authorized Business Partner. Phillips-head screwdrivers Isopropyl alcohol, 91% pure or higher Lint-free wipes or tissues Parts List Verify parts against the parts list below: Quantity Description 1U 2, 4, 8 U 1 Enclosure with bulkhead 4 Adhesive fiber management clips 1 1 Cable gland 1 1 Instruction sheet Separately Orderable Items The panel adapters, ganged adapters, and splice wallets (including splice trays) must be ordered separately. Build-out blocks, coupler, splicing materials, and equipment used with this enclosure are optional and must be ordered separately. Material ID Various (See note) Various (See note) Various (See note) Various (See note) Various (See note) Description Adapter panels numerous panels are available to accommodate ST, SC, and LC or keyed LC fiber connectors Splice wallet kit includes trays for either fusion or rotary mechanical splices and fiber drums InstaPATCH 360 MPO modules and panels ReadyPATCH MPO modules and panels numerous modules are available to accommodate ST, SC, and LC or keyed LC fiber connectors Ganged adapters-numerous ganged adapters are available to accommodate ST, SC, and LC or keyed LC fiber connectors 760027516 RoloSplice (unpopulated) 760031849 RoloSplice with mechanical trays, (4 trays) 760031856 RoloSplice with fusion trays, (4 trays) 760031864 RoloSplice with mass fusion trays, (4 trays) 760039859 RoloSplice with mechanical trays, (2 trays) 760039867 RoloSplice with fusion trays, (2 trays) Note: Contact your local account representative for ordering information. Page 2 of 10

860383587 Issue 8, February 2014 Cautions Isopropyl alcohol is flammable, and can cause eye irritation on contact. If eye contact occurs, flush with water for at least 15 minutes. In case of ingestion, consult a physician. Use only in well ventilated areas. Disconnected optical components may emit invisible optical radiation that can damage your eyes. Never look directly into an optical component that may have a laser coupled to it. Serious and permanent retinal damage is possible. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination. Wearing safety glasses while installing this device is recommended. Although standard safety glasses offer no protection from potential optical radiation, they offer protection from accidental airborne objects and cleaning solvents. Step 1a Configure and Install ReadyPATCH MPO Modules or Panel Adapters in Bulkhead Note: MPO modules must be configured as shown for proper polarity. Identical modules are used at both ends of trunk cable, but module orientation is inverted from end to end. Module at one end of trunk cable must be oriented in ALPHA configuration, while module at opposite end of trunk cable must be oriented in BETA configuration. Page 3 of 10

860383587 Instruction Sheet Step 1b Configure and Install InstaPATCH 360 Modules MPO Module in ALPHA Configuration 1. Orient modules in the ALPHA or BETA configuration as shown above before installation. 2. Select the adapter panels or ganged adapters for the appropriate fiber connectors being terminated. Note: MPO modules, ganged adapters, and adapter panels are ordered separately from enclosure. 3. Verify orientation of ganged adapters prior to mounting adapters in bulkhead. 3. Starting at bottom-left position, insert each MPO module or adapter panel into bulkhead and secure using either the captive rivets on Readypatch modules/panels or the built-in tabs on InstaPATCH modules/panels. Page 4 of 10 MPO Module in BETA Configuration

860383587 Issue 8, February 2014 Step 2 Assemble and Configure Enclosure Install Fiber Management Clips (For Splicing and Pigtail Patching Applications) Note: Fiber management clips are not required if ReadyPATCH or InstaPATCH MPO modules are being used. 1. If fiber management clips are not assembled, then put together the two components to make four clips. Expose adhesive pad on each fiber management clip and affix on rear of enclosure in building entrance side as shown above. Install Optional Splice Wallet Note: If configuration uses splicing, insert the optional splice wallet as instructed below. 1. Using a lint-free wipe and isopropyl alcohol, clean and degrease area on rear wall where splice wallet will be mounted between fiber management clips as shown above. 2. Peel-off paper backing from hook-and-loop strip on bottom of splice wallet. Orient splice wallet so that opening flap faces towards center of enclosure bulkhead. Press splice wallet firmly onto base and hold for several seconds. 3. Secure splice trays using adhesive pads provided on leaves of splice wallet. Clean back of splice trays with a clean wipe and isopropyl alcohol. In order to function properly, all splice wallet leaves must be populated with splice trays, whether or not they are to be used. Note: Splice trays may be populated with splices before trays are mounted into splice wallet. Page 5 of 10

860383587 Instruction Sheet Install Cable Gland Fitting(s) 1. Remove plugs from openings to be used for cable entry. 2. Install fiber cable gland fittings in openings on building entrance side of enclosure as needed to accommodate cables entering enclosure. See figure on the right. Openings are provided on the top and bottom of enclosure. One cable gland is provided, additional glands must be obtained locally. Note: For any openings not used for cable entrance, leave the blank plugs provided with the enclosure to prevent dust from entering unit. Step 3 Mount Enclosure on Wall Mounting 2, 4, and 8P Enclosures Page 6 of 10

860383587 Issue 8, February 2014 Mounting 1P Enclosures 1. Use four No. 10 wood screws (not provided) to mount enclosure to a wall surface such as plywood. When mounting enclosure to any other wall type, use appropriate mounting hardware. Mounting screws are not provided and must be obtained locally. Step 4 Route Fiber Cable(s) into Enclosure 1. Route fiber cable(s) into building entrance side of enclosure through cable gland(s). 2. Remove outer jacket from fiber cable leaving approximately 48 inches (2.1m) of fibers to dress into enclosure. 3. Anchor fiber cables to wall as required and tighten cable gland fitting(s) around cables to secure them. Note: Outer jacket of fiber cable should extend through cable gland before tightening to prevent damage to fibers. 4. Slots are provided in side of enclosure to loosely anchor fibers using cable ties or hook-and-loop straps, if desired. Cable ties or straps are not provided. Page 7 of 10

860383587 Instruction Sheet Step 5a Fiber Routing and Patching Using MPO Modules 1. Route ReadyPATCH cables along side of enclosure and loosely secure cables to enclosure using hook-and-loop straps in the slots provided. Note: Do not tighten hook-and-loop strap on fiber cable or damage to cable will result. 2. Connect ReadyPATCH cables to rear of modules and store slack cable in enclosure in no less than 3-inch (76mm) loops. Step 5b Fiber Routing and Termination Using Pigtails (with or without Splicing) Place fiber identification label on inside of door on this side (see Step 6) Dress slack fibers around fiber clips Fiber management clips Fibers entering splice tray Fiber Routing with Splicing Patch cords Page 8 of 10

860383587 Issue 8, February 2014 Fiber Routing with Splicing in a 1P Enclosure Patch cords Bulkhead with four adapter panels shown Fiber management clip Dress fibers clockwise around fiber clips Fiber Routing without Splicing 1. Terminate a fiber pigtail into adapter, color keying as required. Repeat for all remaining fibers. Bundle all pigtails together with cable tie or hook-and-loop strap at approximately 12-inch (305mm) increments. 2. Perform splicing operations per local practices and store splices in splice trays. Note: The splice wallet with splice trays is ordered separately from the enclosure. Splicing instructions are not covered in this document. 3. Spool fibers into fiber management clips as shown. 4. Secure fibers at side of enclosure using cable ties in slots provided, if desired. Page 9 of 10

860383587 Instruction Sheet Step 5c Fiber Routing and Termination Using RoloSplice Place fiber identification label on inside of door on this side (see Step 6) RoloSplice splice tray holder Spool clockwise through fiber clips 1. Terminate a fiber pigtail into adapter, color keying as required. Repeat for all remaining positions. Bundle all pigtails together with a suitable device that will not damage fibers (i.e. twist-tie or hook-and-loop strip) at approximately 12-inch (305mm) increments. 2. Perform splicing operations and secure splices into splice trays. 3. Spool fiber bundle into fiber management clips as shown. 4. Secure trunk cable using cable ties in slots provided, if desired. Step 6 Install Fiber Identification Label 1. Microsoft Excel label templates are available on the CommScope website. To print a label, go to http:///resources/labeling-templates Select the appropriate panel, shelf, or wallmount template. 2. Label information can be entered into the template directly from a PC application and then printed, or entered manually after the label sheet is printed. Print a label sheet using Avery White Full Sheet Laser 5165 printer paper. 3. Remove backing and stick fiber identification label sheet on inside of door as shown above. Step 7 Close Doors and Lock Enclosure Spool counterclockwise through fiber clips 1. Close doors and lock enclosure using locally supplied locks. Separate locking positions are provided so that each side of unit (building entrance side and patching side) can be locked independently. Page 10 of 10