Phase comparator. User manual Document version: 02i00 Update:

Similar documents
STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

PanelView Plus/VersaView CE Terminals and Display Modules

MDM 011-Z1 Regen Resistor

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Hidden Camera Detector SEL SP-102 ARCAM. Operation manual.

B63/ NS MS. EtherNet/IP LINK

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Power supplies.

PSBOC PSBOC 27,6V/5,5A/OC

SLA Battery Capacity Analyzer

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

MX-T6-PRO/S Tube Rollers

Control Unit KEH-P / Force-1.DIN

Manual Version: V1.00. Video Decoder User Manual

Manual Version: V1.00. Video Decoder Quick Guide

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

CEM-C6 INSTRUCTION MANUAL (M187B B)

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

TCP305A & TCP312A AC/DC Current Probes Instructions

Redundancy unit CP-A RU

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

POCKET MULTIMETER Model No: MM18

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

87421/22A Power Supply. Operating and Service Manual

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

CPCI-PS24 24V-Power Supply

OX 5022-CK OX 5042-CK

CMSA-100 Manual. Cinema Media Server Automation

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

9040/9040UK. Users Manual. Phase Rotation Indicator

USER MANUAL. WBV412U01 AC voltage transducer

DS-1H05 Ethernet-over-Coax Extender. User Manual

Operation manual 2013

PF LED Profile. User Manual

ENGLISH. User manual.

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

USERS MANUAL MINI ONE

MOVEBAND Display Quick Start Guide

You need the following to set up and use your terminal block:

Operating Instructions

ILT2 motorized screens INTERFACE

MODEL C-HOMWA-1 CONNECTIVITY KIT, CONNEX (USB)

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

±15 V Current-Limited Power Supply

Quick Start Guide CJB1950ALAAB

Flat. PIFN-C072B Flat 75W LED Driver. Features. Electrical Specifications. Input Specifications 1 / 8 18V - 23V / 2.00A - 3.

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Smart Grid Tie Microinverter User Manual

HDMI Extender over Cat5e/6

22-60VDC Grid Tie Microinverter User Manual

Crossfire. User Manual. Order code: EQLED061

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Features various encoder interfaces and controls multiple analog servo drives at high speeds

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

iconverter 2-Module Power Chassis

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Linear Shaker & Orbital Shaker

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

UV Power Flood. User Manual. Order code: EQLED029

C9900-P223 and C9900-P224

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

USER MANUAL. Elo Touch Solutions USB Expansion Module

SHUTTERBOSS VERSION II USER MANUAL

Agilent OBSAI Protocol Tester

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Rocking Shaker & 3D Shaker

Operating Instructions

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

ZF LED Zoom Fresnel. User Manual

USER MANUAL. WBI412F41 AC current transducer

RXTP ROOM TEMPERATURE

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

1-36V, 0-3A DC Power Supply

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Sliding shutter control Aluminium shutters

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Quick Start Guide and Health and Safety Information

Transcription:

Phase comparator User manual Document version: 02i00 Update: 2015-03-13

Safety information When the device is in operation some of its parts may be connected to a hazardous live voltage. Improper operation of the device or its application to purposes different from the intended use may pose hazards to operators and /or may lead to the equipment damage. National and local electrical safety regulations must always be followed. The user shall be held fully responsible for any safety risk and possible failures of the equipment that may arise due to such an improper operation or misuse. Exploration of damaged device can result in malfunction of protected object and result in threat to life and health. Reliable and defect-free operation of the device needs appropriate transportation, handling, storage, installation and commissioning as well as correct operation and maintenance. The device can be installed and operated solely by accordingly trained personnel. Attention We reserve the right to modify the device. Device is an industrial monitoring and control instrument. Remaining user documentation can be downloaded from energetyka.itr.org.pl

Spis treści: 1. Introduction... 4 1.1. Symbols... 4 2. General Information... 4 2.1. Destination of the equipment... 4 2.2. Features... 5 2.3. Front panel... 5 2.4. Optical signaling... 5 3. Operation manual... 6 3.1. Checking the operation of the signaller... 7 4. List of referred standards... 7 5. Technical parameters... 8 5.1. Input circuits... 8 5.2. Environmental conditions... 8 5.3. Construction... 8 6. Description of connectors... 9 7. Connection diagram... 9 8. Dimensions... 10 9. Manufacturer remarks... 11 9.1. Maintenance, inspections, repairs... 11 9.2. Storage and transportation... 11 9.3. Disposal... 11 9.4. Warranty and service... 11 10. Contact... 12 IU_SF1_MANUAL_02i00_ENG Page 3 / 12

1. Introduction 1.1. Symbols Electrical warning symbol indicates the presence of hazardous energy circuits or electric shock hazards. The warning symbol indicates the important information related to the damage or improper operation of the device. The information symbol indicates the clarification of relevant features and parameters of the device. 2. General Information 2.1. Destination of the equipment The SPC-type specific phase comparator serves for verification of the coincidence of adopted phase designations at LRM connector in particular MV bays. Fig. 2.1.1 The view of SF 1 When there is no coincidence the following symbol is displayed on the LCD display. The phase comparator type SF - satisfies the LRM system requirements - IEC/PN-EN 61243-5 standard. Page 4 z 12 IU_SF1_MANUAL_02i00_ENG

2.2. Features Case small dimensions 52 / 46 / 46 mm Signalization when there is no coincidence or when no voltage is present on one of the ALn, BLn connectors, the symbol is displayed on the LCD display 2.3. Front panel Fig. 2.3.1. Front panel view 2.4. Optical signaling Tab. 2.4.1. Signaling of operation: LCD signaling Voltage at the connector Description ALn BLn - - no voltage at connectors TEST - voltage only at ALn - voltage only at BLn TEST TEST TEST voltage at two connectors, phase shift < -40 +40 > ( < -40 ) voltage at two connectors, phase shift < -40 ( > +40 ) voltage at two connectors, phase shift > +40 In case of a strong solar radiation on the device front panel it might be necessary to manually dim the LCD display in order to make the signalization more readable. For proper operation the measured voltage difference at the ALn and BLn connectors must be less than 1.5 V rms. The phase comparator shall not be used as a voltage indicator. IU_SF1_MANUAL_02i00_ENG Page 5 / 12

3. Operation manual Proper operating and safety require the device to be correctly inserted into the LRM connector of the voltage indicator. Whilst inserting into the LRM connector hold the device as shown in Fig. 1 and pay special attention so as not to touch metal parts of the ALn, BLn connector and PE where in case of defect (damaged voltage protectors in the LRM connector of the voltage indicator) a dangerous voltage can occur. Fig. 3.1. How to hold the SF 1 Sequence of connecting the phase comparator to the LRM connector according to the scheme, Fig. 7.1.: connect the SF 1 comparator to the line Ln in the LRM connector of the voltage indicator in bay A, next connect a measuring cable to the comparator, then connect the measuring cable to the line Ln in the LRM connector of the voltage indicator in bay B. Take special care whilst connecting the measuring cable to the LRM connectors of the voltage indicator and the phase comparator to avoid electric shock. Page 6 z 12 IU_SF1_MANUAL_02i00_ENG

3.1. Checking the operation of the signaller In order to check the correct operation of the signaler, one has to: connect the 50 Hz, 5 V RMS sinusoidal voltage to the ALn and PE connectors,, check if the symbol and TEST text are lighted on the LCD display, short circuit and connect the ALn and BLn connectors, check if the TEST text is lighted on the LCD display and the symbol is dim, If there are no display errors on the LCD display, the signaller is operating correctly. 4. List of referred standards The device described in this manual has been designed and is manufactured for industrial applications. The engineering and manufacturing processes assume compliance with relevant standards. Adherence to these standards during installation, commissioning and operation of the device by the user is the essential precondition to achieve the desired performance and safety levels. The device meets essential requirements specified in the applicable EU Directives: Electromagnetic compatibility (EMC) 2004/108 / EC Low-voltage electrical equipment (LVD) 2006/95 / EC Tab. 4.1. General and harmonized standards No. standards PN-EN 61000-6-2:2008 PN-EN 61010-1:2011 PN-EN 61243-5:2004 PN-EN 60529:2003 Title of the standard Electromagnetic compatibility (EMC). Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements Live working. Voltage detectors. Voltage detecting systems (VDS) Specification for degrees of protection provided by enclosures (IP code). IU_SF1_MANUAL_02i00_ENG Page 7 / 12

5. Technical parameters 5.1. Input circuits Voltage input circuits Number of inputs 2 Minimal voltage threshold, LCD signaling 4.5 V rms Maximal voltage 20 V rms Frequency 50 Hz Input capacity 600 pf Maximum length of the connected cables < 3 m 5.2. Environmental conditions Operating temperature -25 C +55 C Storage temperature -35 C +85 C Air humidity lack of condensation and frost deposition Equipment class 0 Overvoltage category III Electrical environment B Pollution degree 2 Mechanical tests Sinusoidal vibration class 1 Single and multiple shocks and bumps class 1 Seismic class 0 5.3. Construction Mass Dimensions (width, height, depth) < 0,1 kg 52 / 46 / 46 mm Degree of protection Front panel side IP 54 Connectors side IP 00 Page 8 z 12 IU_SF1_MANUAL_02i00_ENG

6. Description of connectors Fig. 6.1. The view of connectors side 7. Connection diagram Fig. 7.1. Connection diagram IU_SF1_MANUAL_02i00_ENG Page 9 / 12

8. Dimensions Fig. 8.1. Dimensions Page 10 z 12 IU_SF1_MANUAL_02i00_ENG

9. Manufacturer remarks 9.1. Maintenance, inspections, repairs The manufacturer recommends that correctness of device operation is verified: a) each time - during commissioning, b) at least once a year - in mine face installations, c) at least once every 5 years in installations other than front face. Also inspections resulting from branch regulations should be undertaken. 9.2. Storage and transportation Devices are packed in transportation packages and secured against damage during transportation and storage. Devices should be stored in transportation packages, indoors, in places free from vibrations and direct effects of weather conditions, dry, well ventilated, free from harmful vapors and gases. Ambient air temperature should be between 35 C and +85 C, and relative humidity should not exceed 80%. All shipped devices are attached with complete set of connectors, grounding braid, warranty card and quality certificate. 9.3. Disposal Devices are made mostly from recyclable materials, or materials that can be processed again or disposed of in environmentally sound manner. Decommissioned devices can be collected for recycling, provided that their condition is that of normal wear and tear. All components that are not recyclable shall be disposed of in environmentally sound manner. 9.4. Warranty and service Regular 36-month guarantee period; may be extended to 60 or 120 months. Had the sale been preceded by execution of an Agreement between the Buyer and the Seller, provisions of such Agreement shall apply. Guarantee covers remedying of defects, free of charge, provided that instructions specified in the Warranty Card are adhered to. Detailed guarantee conditions may be found at energetyka.itr.org.pl in the Sale Regulations. The guarantee period is counted from the date of sale. The warranty is extended by a period of residence of the product in the repair. Unauthorized tampering with the product will void the warranty. Warranty does not cover damage resulting from improper use of the product. IU_SF1_MANUAL_02i00_ENG Page 11 / 12

10. Contact Tele- and Radio Research Institute ICT and Electronics Centre 03-450 Warsaw, ul. Ratuszowa 11 Poland tel./fax:+ 48 22 619 73 14 e-mail: energetyka@itr.org.pl www: energetyka.org.pl Page 12 z 12 IU_SF1_MANUAL_02i00_ENG