Pre-installation Manual

Similar documents
Hardware Installation. PlateWriter 3600 Pro

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

ZEPHYR Compact Haze Machine

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

User Safety. Electrical Safety. Phaser 4500 Laser Printer

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

Latex 110 Printer. Site preparation guide

Installation Job Aid for Ethernet Routing Switch 3600 Series

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Haze 800 DMX. User Guide. English

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Specifications, Installation, and Operating Instructions

Cobalt 8 Pre-Installation & Site Preparation Guide

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

EPS Power Supply

Avanti HP Series Centrifuges Preinstallation

FOX-50 Heat Flow Meter

Junos WebApp Secure 5.0 Hardware Guide

Fire Fogger 1500 fog machine. user manual

Dell MD1280 Storage Enclosure Getting Started Guide

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Site Readiness Guide. September 2015

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

icore Kiosk system Installation Guide

Preparing to Install the VG248

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

V E2B Snap-in I/O Module

Panduit Basic Rack PDU

E-Series Site Preparation Guide

ICS Entrance Management Sign Installation Guide. Version 1.0

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Installation Job Aid for VSP 4850GTS

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

CPCI System Subrack 1 U

INSTALLATION INSTRUCTIONS

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

3/4 U CPCI Serial Case System

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Model HM-535 Power Supply Installation and Service Instructions

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Customer Responsibilities

V E1B Snap-in I/O Module

Startup Guide C01

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

V E5B Snap-in I/O Module

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

MODEL 805 USER MANUAL

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

CAUTION CAUTION CAUTION HIGH VOLTAGE PRESENT

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Masterswitch 25kW 230V-125A Automatic AC transfer switch

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Installation Job Aid for VSP 4450GTX-HT- PWR+

S-100X / S-200X Snow Machine User Manual

Line Impedance Stabilization Network (LISN)

LOW FOG 3000 FT USER MANUAL. Version: 1.0. ROBE Lighting s.r.o. Czech Republic

Site Readiness Guide. October 2017

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Z-350 FAZER USER MANUAL

Customer Responsibilities

TA18 active subwoofer. user manual

DOT MATRIX PRINTER SP6000 SERIES

Room Temperature Controller

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

TPC25 active crossover. user manual

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer.

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Chameleon Stand-alone

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

Installation Manual. Alpha 4000 RGB Signs. Before you begin

TA12 full-rangespeaker. user manual

Daily use. indicating that the loud speakers

DisplayMaker UV Curable Inkjet Printers

Flexoled FTP3HP RGB LED DMX Driver

Thermal Diffusivity Instruments DLF-2 with EM-1600

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

On-Line CardioTheater Instruction Manual for Amplifier Models 800 and 1600 (wired)

Instruction Manual TI-7700R

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

User safety and equipment protection guidelines

HP Designjet L25500 printer series. Site preparation guide (Second edition)

This manual describes how to prepare a site for the CTL 9712 DPS 7000 Integrated Library Unit (ILU).

FTP1 Single Channel LED DMX Driver

POCKET MULTIMETER Model No: MM18

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

Flying Tickets FT Operation & Service Manual. Version 1.0. * Read this manual before use

Replacing the Power Supply

Transcription:

Pre-installation Manual Rinse Gum Unit 85-125-165

Pre-installation Manual Rinse Gum Unit 85-125-165 T11018 Edition BA, March 2006 This book has part no 51477

0-2 Introduction Part 0: Introduction This guide covers the following equipment: Rinse Gum Unit 85 Rinse Gum Unit 125 Rinse Gum Unit 165 Reservations This manual was written and illustrated using the best possible information available at the time of publication. Any differences between this manual and the equipment reflect improvements introduced after the publication of the manual. Changes, technical inaccuracies and typographic errors will be corrected in subsequent editions. As a part of our policy of continuous improvement, we reserve the right to alter design and specifications without further notice. Pre-installation instructions The instructions in this Pre-Installation Guide allow the customer and the Service Technician to prepare the installation of the Rinse Gum Unit. Only qualified Service Technicians are allowed to unpack and install the equipment. Notes, Cautions and Warnings! Throughout the manual warnings, cautions, and notes are written in bold like the example below: Electrical installation must conform to local regulations and guidelines. 0605 Pre-installation Manual - Rinse Gum Unit

Introduction 0-3 Symbol Meaning Explanation Note Caution Warning The operator should observe and/or act according to the information in order to obtain the best possible function of the equipment. The operator must observe and/or act according to the information in order to avoid any mechanical or electrical damage to the equipment. The operator must observe and/or act according to the information in order to avoid any personnel injury. This manual is published by: GLUNZ & JENSEN A/S Haslevvej 13, DK-4100 Ringsted Denmark Phone:+45 57 68 81 81 E-mail: gjhq@glunz-jensen.com Internet: www.glunz-jensen.com Copyright 2006 by GLUNZ & JENSEN A/S. Pre-installation Manual - Rinse Gum Unit 0605

0-5 Table of Contents Part 0: Introduction... 0.2 Reservations...0.2 Pre-installation instructions...0.2 Notes, Cautions and Warnings!... 0.2 Part 1: Transportation... 1.1 When the Rinse Gum Unit (RGU) arrives....1.1 Storing the RGU before installation....1.1 The crate....1.1 Dimensions and weight....1.1 Checking the crate for damage....1.2 Handling the crate...1.2 Transporting the RGU...1.3 Lifting the crate...1.3 Available width for transport...1.3 Part 2: Installation requirements... 2.1 Environmental requirements....2.1 Cleaning facilities...2.1 Space requirements...2.2 Free space around the machine...2.2 RGU Dimensions...2.3 Water supply and drains...2.4 Water supply...2.4 Drains....2.4 Electrical requirements...2.5 Main power connection....2.5 Main power outlet...2.5 Power cable....2.5 PowerSupply...2.6 Fuses...2.7 Part 3: Pre-installation check list.... 3.1 Pre-installation Manual - Rinse Gum Unit 0605

Transportation When the Rinse Gum Unit (RGU) arrives 1-1 Part 1: Transportation When the Rinse Gum Unit (RGU) arrives Storing the RGU before installation The crated RGU will usually be delivered some time before the arrival of the Service Technician. In such a case you should prepare an appropriate place indoors to store the crated RGU. The crate Dimensions and weight H T11023 RGU Type 85 125 165 Width (W) 1000 mm (39.4") 1000 mm (39.4") 1000 mm (39.4") Length (L) 1895 mm (73.8") 2284 mm (89.9") 2734 mm (107.6") Height (H) 1491 mm (58.7") 1491 mm (58.7") 1491 mm (58.7") Weight, crated 392 kg (864 lbs) 503 kg (1109 lbs) 587 kg (1294 lbs) Weight, without crate 262 kg (578 lbs) 353 kg (778 lbs) 412 kg (908 lbs) Pre-installation Manual - Rinse Gum Unit 0605

1-2 Transportation The crate Checking the crate for damage Check if the crate is damaged at the time of delivery. Take note of the damage before you allow the Service Technician to unpack the RGU. Provide a detailed description or take a photograph of the damage. Report any damage to the crate to the transport company. Handling the crate The icons on the crate indicate how to handle the crate during transport and storage: Ensure that the side indicated by the arrows is always up. Handle the crate with care. Never expose the crate to water, or place it in a high-humidity area. 0605 Pre-installation Manual - Rinse Gum Unit

Transportation Transporting the RGU 1-3 Transporting the RGU Lifting the crate To lift the crate, at least a fork-lift truck or two persons and a hand powered pallet mover are required. It is only possible to insert the forks of the fork-lift truck or pallet mover from the side as illustrated below. T31608 Available width for transport Depending of the width of the door(s) through which the RGU has to be transported to the installation site, the Service Technician may have to perform the actions described in the table below: If width of the door is... Then... > 1000 mm (39.4") < 1000 mm (39.4") > 800 mm (31.5") < 800 mm (31.5") No action is required as the crated RGU can be transported immediately to the installation site. The Service Technician has to unpack the RGU. The Service Technician has to unpack and strip down the RGU. Pre-installation Manual - Rinse Gum Unit 0605

1-4 Transportation Transporting the RGU 0605 Pre-installation Manual - Rinse Gum Unit

Installation requirements Environmental requirements 2-1 Part 2: Installation requirements Environmental requirements Provide a heating and ventilating system capable of maintaining room temperature between 15 and 25 C (59 and 77 F) and relative humidity on max. 80%. Heat emission from the RGU is max. 11900 BTU. Cleaning facilities It is essential to have easy access to a sink and a water tap with hot water where rollers, guides, and brushes can be washed. Minimum recommended size of the sink 85 100 x 40 cm (39.4 x 16") 125 140 x 40 cm (55.1 x 16") 165 180 x 40 cm (70.9 x 16") Pre-installation Manual - Rinse Gum Unit 0605

2-2 Installation requirements Space requirements Space requirements Free space around the machine Decide where the RGU shall be placed and make sure that the free space around the machine makes servicing possible. The recommended minimum free space around the machine is specified in the illustration below: 85 : > 257 cm (101") 125 : > 299 cm (118") 165 : > 344 cm (135") > 60 cm (23.6") > 234 cm ( 92.1") Rinse-Gum Unit > 50 cm (19.7") > 50 cm (19.7") Feed table (optional) > 100 cm (39.4") T31609 For CTP On-line RGUs the space requirements at the RGU front has to be decided separately. 0605 Pre-installation Manual - Rinse Gum Unit

Installation requirements Space requirements 2-3 RGU Dimensions D W H2 H1 T11019 85 125 165 W : Width 156.5 cm (61.6") 199.0 cm (78.3") 244.0 cm (96.1") D : Depth 74.0 cm (29.1") D : Depth w. drain pipe H1 : Input height standard feet 81.5-89.5 cm (32.1" - 35.2") 79.0 cm (31.1") 82.5-90.5 cm (32.5" - 35.6") H2 : Total height 110.6-118.6 cm (43.5-46.7") 116.9-124.9 cm (46.0-49.2") Pre-installation Manual - Rinse Gum Unit 0609

2-4 Installation requirements Water supply and drains Water supply and drains Water drain Gum drain (optional) 85 : 760 mm (29.9") 125 : 995 mm (39.2") 165 : 1220 mm (48.0") Water supply inlet 85 : 220 mm (8.7") 125/165 : 240 mm (9.4") 85 : 100 mm (3.9") 125/165 : 120 mm (4.7") 290 mm (11.42") Rinse-Gum Unit Gum drain (standard) Feed table (optional) T31610 Water drain min. height over floor 350 mm (13.8") Prepare the installation site for water supply and drain connections according to the illustration above. Please also refer to the RGU dimensions described earlier in this document. Water supply The water supply connection is located on the rear side of the RGU. The supply water pressure must be 2-6bar(29-87psi). Drains The wash drain can be led to public drain. Refer to local regulations. The gum must be drained into a container and recirculated. Many countries have strong regulations regarding disposal of waste. Refer to the local regulations when making preparations for drains. 0605 Pre-installation Manual - Rinse Gum Unit

Installation requirements Electrical requirements 2-5 Electrical requirements Electrical installation must conform to local regulations and guidelines. Main power connection The main power connection is made in the RGU's field-wiring box located on the left side of the RGU as shown in the illustration below. Control panel Electronic cabinet Main power connection Rinse-Gum Unit Main switch Feed table (optional) T31611 Main power outlet Provide a main power outlet close to the installation site. The table on the next page indicates the applicable power supply types and to which RGU models they apply. Power cable The cable for the main power connection is not delivered with the RGU. The table on the next side also shows recommended power supply cables. When deciding what type of cable to use take into account the chemical resistance (chemicals may leak onto cable) and the mechanical resistance (operator may step onto cable). The conductors in the power supply cable should be of copper. Provide for additional cable protection, e.g. cable covers, if cable is exposed to heavier transport such as fork-lift trucks etc. The RGU is Class 1 equipment. Therefore, the RGU must be connected to earth to avoid electrical shocks. Please be aware of double pole/neutral fusing. Pre-installation Manual - Rinse Gum Unit 0605

2-6 Installation requirements Electrical requirements Power Supply Supply/Fuse Recom. cable type 85 125 165 EUR US JAP 1W+N+PE 230V AC, 1x10 Amps, 50/60 Hz 3W+N+PE 400V AC, 3x10 Amps, 50/60 Hz 2W+PE 230V AC 2x10 Amps, 50/60 Hz 2W+PE 230V AC 2x20 Amps, 50/60 Hz 3W+PE 230V AC 3x10 Amps, 50/60 Hz 3W+PE 230V AC 3x20 Amps, 50/60 Hz 2W+PE 200V AC 2x10 Amps, 50/60 Hz 2W+PE 200V AC 2x15 Amps, 50/60 Hz 3W+PE 200V AC 3x10 Amps, 50/60 Hz 3W+PE 200V AC 3x15 Amps, 50/60 Hz Min. 3 x 1.5 mm 2, type H07 RNF Min. 5 x 1.5 mm 2, type H07 RNF Min.3x14AWG, type SJO Min.3x14AWG, type SJO Min.4x14AWG, type SJO Min.4x14AWG, type SJO Min.3x14AWG, type * Min.3x14AWG, type * Min.4x14AWG, type * Min.4x14AWG, type * All Voltage tolerance +10% / -10% *) Power cord must be in accordance with local regulations. Fuses The fuses must have a breaking capacity of min. 100kA. If using automatic circuit breakers make sure that they are Type D. 0605 Pre-installation Manual - Rinse Gum Unit

Pre-installation check list 3-1 Part 3: Pre-installation check list Please ask the customer to answer the following questions in order to ensure a trouble-free installation of the RGU: 1. Delivery of the crate and transport to the installation site YES NO A. Is there a place indoors where the packing box can be stored temporarily? B. Is there a hand-powered pallet mover, a fork-lift truck or any other lifting device available? C. Can the crate be transported directly to the installation site? See minimum width specifications on page 7. D. Is it sufficient to unpack the RGU before it is transported to the installation site? See minimum width specifications on page 7. E. Are there other factors (stairs, elevators, corners, obstacles, etc.) which should be taken into account when transporting the crate or RGU? If so, explain:............ 2. Power supply A. Make a note of the present supply specifications: No. of Phases... Voltage... V Fused by... Amps Neutral Wire?... Earth Wire?... Frequency... Hz YES B. Has a connection box been provided to connect the RGU to the mains? C. Is the customer aware that he/she should provide (or order) all supplies (cables, fuses, etc.) necessary to connect the RGU to the mains? D. Is there a house electrician available? E. Are there any known problems in the building where the RGU will be installed? If so, explain:............ NO Pre-installation Manual - Rinse Gum Unit 0605

3-2 Pre-installation check list 3. Water supply and drain YES NO A. Capacity of air condition/ventilation adequate with regard to BTU max. 11900? B. Can a hose 3/4" BSP be connected to the water supply tap? C. Is there a large sink (with hot water) for cleaning the equipment? D. Will the RGU be connected to a local waste treatment system? E. Is the tap water temperature adjustable? (If recommended by plate supplier). F. Does the supply water pressure lie between 2 and 6 bar (29 and 87 psi)? G. Availability of warm water for cleaning of the RGU? 4. Need for accessories A. Remark the input height of the Rinse Gum Unit. Is there a need for leg extenders? 5. Disposition of the various supplies and equipment on the installation site: 0605 Pre-installation Manual - Rinse Gum Unit