Panasonic Optical Data Archiver freeze-ray

Similar documents
LB-DH8 series Data Archiver Made-to-order product. A scalable optical disc library system that satisfies increasing demand for long-term data storage

LB-DM9 series. Data Archiver

Dell MD1280 Storage Enclosure Getting Started Guide

Figure 1 shows the appearance of Huawei FusionServer RH8100 V3 Rack Server. The RH8100 V3 provides three front I/O modules:

This document describes the features and functional specifications of the ECONO3 air conditioner controller.

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

1U Device Expansion Unit Configuration Guide

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

E-Series Site Preparation Guide

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell EMC PowerEdge R7425

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Optical Disc Libraries. No compromises. Put your trust in the new generation of data storage!

Dell EMC PowerEdge R540

USB 3.0 to SATA IDE HDD Docking Station for 2.5in or 3.5in Hard Drive

HMIPPH7A0701 Panel PC Performance - Hard Disk - 15'' - AC - 0 slot - fan

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Dell EMC PowerEdge R7415

Air data test indicator Model CPA2501

Dell SC7020 Storage Controller Getting Started Guide

Safety Standards. Model Number: Unit Weight:

Dell EMC PowerEdge R740xd

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

The new standard for data archiving

Dell EMC PowerEdge T440

EMC SYMMETRIX VMAX 40K SYSTEM

Dell EMC PowerEdge R540

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

RT12-240V/2.4kW Rectifier Specification

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Artico NAS Storage Appliance Site Planning Guide

HMISTO " wide screen touch panel, Ethernet

iosafe 1517 Hardware Guide Powered by Synology DSM

ETERNUS LT20 S2, LT40 S2 and LT60 S2

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

SXL-8: LTO-8 Archive System. managed by XenData6 Server software. Eight cartridge library simplifies management of your offline files.

Storageflex HA3969 High-Density Storage: Key Design Features and Hybrid Connectivity Benefits. White Paper

Dell EMC PowerEdge R740xd

Cisco Secure Network Server

HMIGTO1310 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 96 MB

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

StorNext M440 Site Planning Guide

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

MINI-ISO AUTOMOTIVE RELAY

Dell PowerEdge R640. Technical Specifications. Regulatory Model: E39S Series Regulatory Type: E39S001

SAS JBOD Installation Reference Guide Revision 1.0

Datasheet Fujitsu ETERNUS DX90 S2 Disk Storage System

VCL-TP, Teleprotection Equipment

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Dell EMC PowerEdge R740

HP CD-Writer 8230e - Product Specifications

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Cisco Secure Network Server

Safety Standards. Model Number:

DMC-1000 Chassis-Based Media Converter

AUTOMOTIVE MICRO-ISO RELAY FEATURES

The USB connector can be used for firmware updates and storing the Library configuration.

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Acer Hitachi AMS2300 specifications

The Fastest Scale-Out NAS

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

Installing the IPS 4345 and IPS 4360

NVE40K Installation Guide

3ME2 Series. Customer Approver. Innodisk Approver. Customer: Customer Part Number: Innodisk Part Number: Innodisk Model Name: Date:

Voltage Current Front-mounting bracket

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11

iosafe Hardware Guide Powered by Synology DSM

Cisco Connected Safety and Security UCS C220

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

RT4B-110V/12A RECTIFIER

Dell SC460 Expansion Enclosure Getting Started Guide

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

BMEP processor module M580 - Level 1 - Distributed

Control Panel CP600-eCo CP604, CP604-B

User Operation Manual: Motorized Valve Controller for Valved Sources

Safety Standards. Model Number:

General Specifications

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

Dell EMC PowerEdge R7425

HMIGTO1300 advanced touchscreen panel 320 x 240 pixels QVGA- 3.5" TFT - 64 MB

4 Bay esata USB 2.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

PMT. Safety Standards. Model Number:

Safety Standards. Model Number:

ReadyNAS OS 6 Desktop Storage Systems

XenData Product Brief: SX-550 Series Servers for Sony Optical Disc Archives

Universal Docking Station for Hard Drives - USB 3.0 with UASP

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

C inch SSD Contents

Dell EMC PowerEdge R6415

Transcription:

Panasonic Optical Data Archiver freeze-ray 1 Scope This document applies to Panasonic Optical Data Archiver freeze-ray that is designed and validated to meet large scale data center and enterprise market specific needs. Adoption of optical media enables storage of critical & valuable data safely for a long period. Optical data archive is an immutable and low cost solution to meet the ever-increasing data archive needs. 2 Product outline 300GB Archival Disc based Optical Data Archiver Meeting the need for ever-increasing data volumes Density of 1,641.6TB (1.6PB) per standard 19 inch rack. Optional density can be configured in the range of Min 547.2TB Max 1,915.2TB (1.9PB). Adoption of immutable and low cost media Physical Strength: - Physically WORM - no data overwrite (no falsification, human error free) - Optical Medium - no physical contact (no components damages, maintenance free) Environmental Strength: - Thermal Tolerant - no media degradation (estimated life time of 100 years or more at temperature of 30 C and humidity of 70% RH based on accelerated test being conducted) - Disaster Recovery - no data damage (business continuity, restoration free) Low Cost (TCO) achievement: - Capital Expenditure - no media obsolescence (one time investment, migration free) - Operational Expenditure - no power wasted (reduced cooling cost, low power usage) Library software ready to control the system easily in DCs Conforms to MMC and SMC standard. Library software installed in server enables direct access to drives and robotics. Meets the DC specific design requirements Maintaining the system availability. - Optical Data Archiver has one or more drives to allow multiple access. In addition, if failure occurs in one of the drive, drive system can continuously operate. - Even in the event that the host system (upper layer of data archiver) suddenly freezes or the power supply stopped, it has been confirmed that the system can still be recovered through the hardware testing and forced error testing. Mar 8 th, 2016 Panasonic Corporation Page 1 of 8

Ensuring serviceability for DC technicians - Front (cold isle) serviceable - Tool less operation for drive exchange, robotics maintenance and all other services - FRU (Field Replaceable Unit) available for quick, easy and safe unit exchanges Matching DC environmental conditions - Altitude: DCs may be located at a maximum of 1000 meters above sea level. Our system works under any variation of air properties. - Temperature: System operating temperature is between 10 C ~ 35 C and can work under the un-air conditioning temperature in DCs. - Relative Humidity: System operating humidity specification is between 20% ~ 80% and can work under the relative humidity in DCs. - Particulates: DCs are usually equipped with air filtration but there still remains particulates in the air. Optical data archiver is designed to work in ISO class eight. Designed to function under transportation shock & vibration conditions - Transportation shock / vibration testing per ASTM D4169-09: To shorten the lead time of system installation at DC, magazines are inserted in the drawer and archive modules are mounted on the rack before shipping out from the integration site. Our system is designed for long distance transportation. Optional 19inch rack mountable Server Bay available - OCP server (not included) and OCP power supply (not included) unit mountable - Or customer can specify their own gear without the server bay Optional Data Archive Manager (DAM) middleware - REST API (Swift Object Storage), S3 API (emulated by swift3), NAS (CIFS/NFS) interface supported 3 System reliability for long-term data archive 3.1 Robotics The robotics used in the Optical Data Archiver is robust and any calibration needed will be performed autonomously to no user intervention. 3.2 Robotics controller The controller board that handles the robotics and the main system is capable of monitoring and reporting system data back to the server via the API. - Temperature readings for each drives - Ambient temperature of the base module - Critical system voltages (12V, 24V, power supply voltages) - Hardware and firmware revisions used in the system - Fan operation and rotation speed 3.3 Data erasure feature Supports the ability to corrupt data when data stored on the media is no longer required. Mar 8 th, 2016 Panasonic Corporation Page 2 of 8

4 Product specifications 4.1 Main specifications All values are specified under the standard operating condition. Refer to clause 5.3. Table 4.1: Main specifications Standard Spec Optional Spec Capacity 1,641.6 TB (1.6PB) 547.2TB - 1,915.2TB (1.9PB) Number of Magazine 456 Magazines 152 Magazine - 532 Magazine Disc Type 300GB Archival Disc - AC Input External power supply - Power Consumption Ave. 262W Ave. 137W - 386W Writer unit 4 units (12 drives) 2 unit (6 drive) - 6 unit (18 drive) Disc Access Single disc access RAID Access (RAID 0, 5, 6) with optional DAM middleware Transfer rate Ave. 720 MB/s (read/write) Ave. 360 MB/s - 1,080 MB/s Drive Type 300GB drive - with double side OPU 4.2 Operational condition Table 4.2: Operational conditions Item Remarks Temperature Operating 10 C to 35 C Shipping environment -20 C to 60 C Within 72 hours Temperature inclination 10 C/hour maximum at operating Humidity Operating 20%RH to 80%RH Shipping environment 10%RH to 90%RH No condensing Humidity inclination 10%RH/hour maximum 4.3 Structure of Optical Data Archiver Fig.4.3: Structure image Table 4.3: The structure table Standard Spec Number of unit (e) (a) Base module with writer unit (Size:6U) 1 (c) (d) (b) Bottom module with robotics (Size:4U) (c) Expansion module w/ Drive (Size:6U) 1 3 (a) (c) (c) (b) (d) Expansion module w/o Drive (Size:6U) (e) Server Bay - OCP server (not incl.), power supply (not incl.) mountable (Size : 3U) 2 1 Mar 8 th, 2016 Panasonic Corporation Page 3 of 8

4.4 Each module specifications Table 4.4-1: Base module specifications 300G model Writer unit 1 unit (300GB drive x3 units) **removable DC Input DC +12V/+24V* x1 12V/5A, 24V/0.1A Power SW Push SW with Green LED SAS SFF8644 x 2 USB for Hosts USB 2.0 Type B x1 USB for expansion Module USB 2.0Type A x8 Fan 2 Fans Air direction : Out to In **removable Fan Control Optimized Drawer 10 drawers (76 Magazines) **removable LED Indicator 5 LED Dimensions (W x H x D) 447x 262 x 927mm (6U) Weight 40Kg (w/o Magazines) Table 4.4-2: Bottom module specifications DC Input 24 V DC* x1 *JN2 series(jae) 24V/0.5A USB USB2.0 Type A x1 Drawer No LED Indicator No Remarks Maintenance from rear side(hot isle) Dimensions (W x H x D) 446x 175 x 867mm (4U) Weight 23Kg Table 4.4-3: Expansion module specifications with drive bay 300G model Writer unit 1 unit (300GB drive x3 units) **removable DC Input DC +12V/+24V* x1 12/5A, 24V/0.1A SAS SFF8644 x 2 USB for Base module USB 2.0Type A x1 Fan 2 Fans Air direction : Out to In **removable Fan Control Optimized Drawer 10 drawers (76 Magazines) **removable LED Indicator 5 LED Dimensions (W x H x D) 447x 262 x 927mm (6U) Weight 39Kg (w/o Magazines) Mar 8 th, 2016 Panasonic Corporation Page 4 of 8

Table 4.4-4: Expansion module specifications w/o drive bay DC Input No (VBUS) USB USB2.0 Type A x1 Drawer 10 drawers (76 Magazines) **removable LED Indicator No Dimensions (W x H x D) 447x 262 x 927mm (6U) Weight 25Kg (w/o Magazines) Capacity Disc numbers Disc Type RF ID BCA (Disc ID) Table 4.4-5: Magazine specifications 300GB 3.6TB Twelve 300GB Archival Disc Yes Yes Mar 8 th, 2016 Panasonic Corporation Page 5 of 8

5 Precautions for use 5.1 Maintenance Table 5.1: Maintenance policy of Optical Data Archiver. Implementation Green marker for the Technician (Highlight the maintenance point) Yes Confirmation method of the gear connection Yes Screw for removing writer unit Tool less (dropping protection) Screw for removing drive Tool less (dropping protection) Fan exchange Tool less (dropping protection) 5.2 Main FRU (Field Replaceable Unit) list Table 5.2: Main FRU list of Optical Data Archiver Item Image 1) Writer Unit 2) Drive 3) Magazines with 12 discs 4) Magazine Drawer 5) DC FAN Motor Unit 6) Expansion Unit 7) Bottom Module 5.3 Standard operating condition Table 5.2: Standard operating condition Item Remarks Power-supply voltage +24V DC±5%, +12V DC ±5% Temperature 10 C~35 C Humidity 20% ~ 80%RH Inclination angle 0 ±1 Horizontal Vibration and impact Without vibration and impact Mar 8 th, 2016 Panasonic Corporation Page 6 of 8

6 Mechanical dimensions 6.1 Base module dimensions 6.2 Bottom module dimensions 6.3 Expansion module dimensions (with writer unit) Mar 8 th, 2016 Panasonic Corporation Page 7 of 8

6.4 Expansion module dimensions (without writer unit) Mar 8 th, 2016 Panasonic Corporation Page 8 of 8