emc99467 What are the Initiator, Arraycommpath, and Failovermode settings for PowerPath, DMP, PVLinks, and native failover software?

Similar documents
EMC Simple Support Matrix

EMC CLARiiON Asymmetric Active/Active Feature (ALUA)

Veritas NetBackup Enterprise Server and Server 6.x OS Software Compatibility List

Release Notes P/N REV A03 January 3, 2006

Technical Note P/N REV A01 November 24, 2008

Validated Components List for EqualLogic PS Series SANs

Veritas Storage Foundation in a VMware ESX Environment

Veritas Storage Foundation Basic - Technical FAQ January 2009

Veritas InfoScale TM Operations Manager 7.3 Hardware and Software Compatibility List

Veritas Storage Foundation In a VMware ESX Environment

Unitrends Compatibility and Interoperability matrix for Release

Veritas Storage Foundation for HPE-OEM Solutions 6.1 Hardware Compatibility List

Release Notes. EMC PowerPath for Linux. Version 4.3. P/N Rev A09. June 7, 2005

October Veritas InfoScale TM Operations Manager 7.1 Hardware and Software Compatibility List

Symantec NetBackup PureDisk Compatibility Matrix Created August 26, 2010

Release Notes P/N REV A06 September 30, 2009

NetVault : Backup Supported Platforms

Storage Compatibility Guide for ESX Server 3.0

Symantec NetBackup Enterprise Server and Server 7.x OS Software Compatibility List

SAN Data Migration Made Easy

October Veritas TM Operations Manager 6.1 Hardware and Software Compatibility List

1. Revision Page Revision Page 1

Veritas Storage Foundation 5.0 Dynamic Multi-pathing. Optimizing Availability and Performance in Multi-Vendor Environments May 2007

EMC CLARiiON Server Support Products for AIX Server Installation Guide

UNITRENDS COMPATIBILITY AND INTEROPERABILITY MATRIX

VMware with CLARiiON. Sheetal Kochavara

The Contents and Structure of this Manual. This document is composed of the following 12 chapters.

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Veritas Dynamic Multi-Pathing for VMware 6.0 Chad Bersche, Principal Technical Product Manager Storage and Availability Management Group

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix

SAN Storage Array Workbook September 11, 2012

Vendor: EMC. Exam Code: E Exam Name: CLARiiON Installation and Troubleshooting Specialist. Version: Demo

Enabling Fast Recovery of Your Virtual Environments: NetBackup, Backup Exec & VCS for VMware

Data Protector 10.x Zero Downtime Backup and Instant Recovery Support Matrix for HPE P6000 EVA Disk Array Family Using SMI-S Agent

Veritas NetBackup Enterprise Server and Server x.x OS Software Compatibility List

Hitachi Provisioning Manager Software Release Notes

Clustered Storage for High Avaliability Clouds

Veritas Storage Foundation and High Availability Solutions Virtualization Guide

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix

Veritas NetBackup Enterprise Server and Server x OS Software Compatibility List

HP StoreVirtual Compatibility Matrix

Storage / SAN Compatibility Guide For ESX Server 3.x

EMC CLARiiON iscsi Server Setup Guide for HP-UX

Dell EMC Unity Family

HPE Data Protector 8.10 Platform and Integration Support Matrix

Introduction to the CX700

StorNext Supported Operating Systems and Platforms

EMC ControlCenter 6.0. Support Matrix P/N REV A15. EMC Corporation Corporate Headquarters: Hopkinton, MA

Arrays. Dynamic Multi-Pathing (DMP) Device Specific Module (DSM) Supportability. 3rd Party Multipathing Support. Notes. Windows Server 2008 R2 Support

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

Symantec NetBackup Enterprise Server and Server 7.x Hardware Compatibility List

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Currently shipping versions:

Data Protector 10.x Express Support Matrix

EMC Host Connectivity Guide for Sun Solaris

Symantec Storage Foundation and High Availability Solutions 6.1, DDI_R1_2016 and Dynamic Multi-Pathing 6.1 for Windows Hardware Compatibility List

Software-defined Shared Application Acceleration

HP StorageWorks 4100/6100/8100 Enterprise Virtual Arrays

Veritas Cluster Server Application Note: Support for HP-UX Integrity Virtual Machines. HP-UX 11i v2, HP-UX 11i v3

EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts

Managing VNX Block Storage

QuickSpecs. HP Integrity Virtual Machines (Integrity VM) Overview. Retired. Currently shipping versions:

3PAR InForm Operating System Upgrade Pre-Planning Guide. 3PAR, Inc Technology Drive Fremont, CA USA

EMC Celerra MPFS over FC for HP-UX, AIX, and Solaris Clients Version 4.0. Product Guide P/N REV A04

Symantec Storage Foundation and High Availability Solutions 6.1, DDI_R1_2016 and Dynamic Multi-Pathing 6.1 for Windows Hardware Compatibility List

HP StorageWorks Enterprise Virtual Array

Netapp Interoperability Matrix

Managing VNX Block Storage

Veritas NetBackup 6.5 Clients and Agents

White Paper FUJITSU Storage ETERNUS DX S4/S3 series 512e HDDs: Technology, Performance and Configurations

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.1 and 7.2 for Windows Hardware Compatibility List

Release Notes P/N Rev A05

Release Notes P/N Rev A02

Veritas NetBackup Snapshot Client Administrator's Guide

Storage / SAN Compatibility Guide For ESX Server 3.5 and ESX Server 3i

Release Notes P/N REV A01 February 23, 2006

UltraPath Technical White Paper

EMC Navisphere Server Software for Solaris ADMINISTRATOR S GUIDE. EMC Enterprise Storage

SANsurfer FC HBA Manager. Table of Contents

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.3 and for Windows Hardware Compatibility List

SANsurfer FC HBA Manager. Table of Contents

ADMINISTRATION GUIDE IntelliSnap EMC Isilon

HP Data Protector 7.0 Virtualization Support Matrix

HP Serviceguard for Linux Certification Matrix

ASG-Software Compatibility Guide

Veritas InfoScale Foundation, Availability, Storage and Enterprise Solutions 7.0, and DDI_R1_2016 for Windows Hardware Compatibility List

HP Data Protector 7.00 Platform and Integration Support Matrix

VMware Infrastructure 3.5 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

TECHNICAL SPECIFICATIONS

Interoperability of Bloombase StoreSafe Security Server, QLogic FC-HBAs and QLogic SAN Switch for Transparent Storage Area Network (SAN) Encryption

Storage Foundation Management Server: Technical FAQ July 2006

Terminology. This document uses the following terms:

FREQUENTLY ASKED QUESTIONS: VCS I/O FENCING. Frequently Asked Questions: Veritas Cluster Server I/O Fencing

BROCADE SILKWORM 20X0, 2400, 2800, 3800, MDS 9120, MDS 9216, MDS 9509

Release Notes P/N REV A05 July 7, 2006

Veritas CommandCentral Storage Release Notes

Windows Host Utilities Installation and Setup Guide

FUJITSU Storage ETERNUS SF Storage Cruiser V16.3 / AdvancedCopy Manager V16.3. Cluster Environment Setup Guide

Tape Storage Interoperability Matrix

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents

Transcription:

See the Installation Roadmap for CLARiiON Storage Systems, P/N 069001166 for the required failovermode, initiator type settings etc. for any failover software that is not listed in this knowledgebase solution. AIX... 2 Apple... 2 HP-UX... 2 IRIX... 2 Linux... 2 Open VMS... 2 NetWare... 3 Solaris... 3 Tru64... 3 VMware... 3 Windows... 3 Celerra... 3 Footnotes:... 4 Page 1 of 9 December 20, 2010

AIX DMP (AIX 5.1, 5.2, 5.3 only) 7 MPIO Initiator Type 3 (CLARiiON open) 3 (CLARiiON open) 3 (CLARiiON open) Arraycommpath 1 (Enabled) 1 1 (Enabled) 1 (Enabled) Failovermode 3 or- 4 6 1 or- 2 or- 4 13 1 or- 4 19 UnitSerialNumber Array Array Array Apple ATTO HBA stack Initiator Type 3 (CLARiiON open) Arraycommpath 1 (Enabled) Failovermode 4 UnitSerialNumber Array HP-UX Initiator Type (AccessLogix) Array Systemtype (non AccessLogix) Arraycommpath HP-UX 11i v1 & 11i v2 HP-UX 11i v3 PVLinks No PVLinks DMP Native,, DMP HP auto trespass HP no auto HP no auto HP no auto CLARiiON Open 20 trespass trespass trespass or- HP no auto trespass 8 2 decimal 10 (hex a) decimal 10 N/A N/A (hex a) 0 (Disabled) or- 0 (Disabled) or- 1 1 (Enabled) 1 (Enabled) 1 (Enabled) 1 (Enabled) 2 (Enabled) 2 Failovermode 0 0 1 or- 4 15 1 or- 2 14 4 UnitSerialNumber LUN or Array 3 LUN or Array 3 LUN or Array 3 LUN or Array 3 LUN or Array 3 IRIX Native Failover Initiator Type 9 (SGI) Arraycommpath 0 Failovermode 0 UnitSerialNumber Array Linux DMP DM-MPIO Initiator Type 3 (CLARiiON Open) 3 (CLARiiON Open) 3 (CLARiiON Open) Arraycommpath 1 (Enabled) 1 (Enabled) 1 (Enabled) Failovermode 1 or- 4 11 1 or- 2 -or- 4 9 1 or- 4 10 UnitSerialNumber Array Array Array Open VMS Native Failover Initiator Type Decimal 28/ hexadecimal 1C (Compaq/Tru64) Arraycommpath 1 (enabled) Failovermode 1 or 4 21 UnitSerialNumber LUN Page 2 of 9 December 20, 2010

NetWare Initiator Type 3 (CLARiiON open) Arraycommpath 1 (Enabled) Failovermode 1 UnitSerialNumber Array Solaris DMP MPxIO or STMS Initiator Type 3 (CLARiiON Open) 3 (CLARiiON Open) 3 (CLARiiON Open) Arraycommpath 1 (Enabled) 1 (Enabled) 1 (Enabled) Failovermode 1 or- 4 11 1 or- 2 or- 4 4 1 or- 4 12 UnitSerialNumber LUN or Array 5 LUN or Array 5 LUN or Array 5 Tru64 Native Failover Initiator Type decimal 28/ hexadecimal 1C (Compaq/Tru64) Arraycommpath 1 (Enabled) Failovermode 0 UnitSerialNumber Array VMware Native Failover Initiator Type 3 (CLARiiON Open) 3 (CLARiiON Open) Arraycommpath 1 (Enabled) 1 (Enabled) Failovermode 1 or- 4 16 1 or- 4 17 UnitSerialNumber Array Array Windows DMP (Windows 2000, 2003, Native Failover (Windows 2008 only) Server 2008 only) Initiator Type 3 (CLARiiON open) 3 (CLARiiON open) 3 (CLARiiON open) Arraycommpath 1 (Enabled) 1 (Enabled) 1 (Enabled) Failovermode 1 or- 4 11 1 or- 4 18 4 UnitSerialNumber Array Array Array Celerra See solution emc95145 for standard parameters or settings for Celerra systems running with CLARiiON storage arrays. Page 3 of 9 December 20, 2010

Footnotes: 1. For AIX, arraycommpath should be set to Enabled (1). Also see footnote 6. 2. For HP-UX, arraycommpath can be 1 (Enabled) or 0 (Disabled); either will establish connectivity with the storage system. However, if diskinfo is to be used, then use 0 for the setting (emc68877) or diskinfo will return zero bytes for the alternate path. 3. For HP-UX 11i v1.0, UnitSerialNumber may have been changed to LUN if problems were experienced with the device display in the HP-UX SAM utility. 4. For Sun Solaris installations using VERITAS VxVM, set failovermode as follows: VERITAS VxVM 4.X with : failovermode MUST be set as required by VERITAS VxVM 4.0 MP2 and VxVM 4.1: failovermode can be set to 1 or 2 with DMP VERITAS VxVM 4.0 MP1 and earlier, without : failovermode MUST be set to 2 VERITAS VxVM 5.0 MP3 (no RP) and earlier, failovermode MUST be set to 1 VERITAS VxVM 5.0 MP3RP1 and above: failovermode settings are as follows: - FLARE 24 or earlier: failovermode MUST be set to 1 - FLARE 26 or later: failovermode may be set to 4 for ALUA behavior, or failovermode may be set to 1 for active/passive behavior Note: Additional VERITAS packages may need to be installed. Note: When failovermode is set to 2 in 4.0 MP2 and 4.1, the LUNs may trespass back and forth between SPs during boot, which makes boot time much longer. This also generates excessive failover error messages in the console and messages file, therefore setting failovermode to 1 is recommended but not required. 5. The UnitSerialNumber setting is dependent on the configuration. Select the proper setting as follows: For Solaris 2.6, 2.7, 8: a. For DMP or, determine if any of the following packages are present: Solstice DiskSuite (SUNWmdr) Sun Cluster 3.x (SUNWscr) VERITAS DBE/AC (VRTSdbac) SFRAC (VRTSdbac) b. Perform the applicable sub-step: If none of the packages listed above are present, the UnitSerialNumber MUST be set to ARRAY. Page 4 of 9 December 20, 2010

If any of the packages listed above are present, set the UnitSerialNumber as follows: - SDS, SC 3.x, SFRAC: UnitSerialNumber MUST be set to LUN - VRTSvcs with I/O fencing: UnitSerialNumber MUST be set to LUN - VRTSvcs without I/O fencing: UnitSerialNumber MUST be set to ARRAY The following indicates whether I/O fencing is enabled: o The /etc/vrtsvcs/conf/config/main.cf file contains a line of "UseFence = SCSI3". o o The /etc/vxfentab file is not empty. The /sbin/vxfenadm -g all -f /etc/vxfentab command returns at least one SCSI3 keys. For Solaris 9 and 10: the unit serial number MUST be set to ARRAY. 6. Note 4.5.0 is available by RPQ only, and earlier versions are EOL. The minimum version for NDU support is 4.5.1. For AIX running versions between 4.5.1 and 5.3 (no Service Pack): failovermode should be 3. For 5.3 SP1 and above failovermode settings are as follows: o FLARE 02.xx, 03.xx, and 04.xx earlier than 04.28.000.5.704: failovermode MUST be set to 3 o FLARE 04.28.000.5.704 or later: failover mode MUST be set to either 3 or 4: failovermode may be set to 4 for ALUA behavior, or failovermode may be set to 3 for active/passive behavior See Release Notes for any further restrictions 7. For CLARiiON array support with DMP only, VxVM 4.0 MP2 and VxVM 4.0 MP3 require DGC-Clar version 3.0. DGC-Clar version 3.0 can be obtained on the Symantec web site, at the following link: http://seer.entsupport.symantec.com/docs/276079.htm This applies to both CX-series and CX3-series arrays. 8. You may use CLARiiON Open or "HP No Auto Trespass" if your applications use only Persistent Device Special Files (DSFs), also known as Agile DSFs, which have the format /dev/disk/disk42 and /dev/rdisk/42. You must use HP No Auto Trespass if your applications require Legacy DSFs, which have the format /dev/dsk/c2t1d0 and /dev/rdsk/c2t1d0. September 2007 HP-UX bundle (0709) is required. For more information, see the HP-UX 11i v3 Persistent DSF Migration Guide (http://docs.hp.com/en/dsfmigration/persistent_dsf_migration.pdf ). Note: If using the Navisphere agent.config file, ensure that the appropriate "OptionsSupported" setting is in the file, otherwise the initiator setting on the array will be changed when the Navisphere agent starts up. To maintain the Navisphere Manager initiator Page 5 of 9 December 20, 2010

setting, uncomment the "OptionsSupported" line in the agent.config file, and change it to state "OptionsSupported ArrayType". 9. For Linux installations using VERITAS VxVM, set failovermode as follows: VERITAS VxVM 4.x or 5.x, with : failovermode MUST be set as required by VERITAS VxVM 4.x without : failovermode MUST be set to 2 VERITAS VxVM 5.0 MP3RP2 without HF3, and earlier, failovermode MUST be set to 1 VERITAS VxVM 5.0 MP3RP2HF3 and above: failovermode settings are as follows: o FLARE 24 or earlier: failovermode MUST be set to 1 o FLARE 26 or later: failovermode may be set to 4 for ALUA behavior, or failovermode may be set to 1 for active/passive behavior 10. For Linux DM-MPIO, failovermode settings are as follows: - Novell SLES: Novell SLES 10.1 (SP1) or above: failovermode may be set to 1 for active/passive behavior, or Novell SLES 10.1 (SP1) or above: failovermode may be set to 4 for ALUA behavior Novell SLES 10.0 (no SP) or below: failovermode MUST be set to 1 - RedHat RHEL 4.x: RHEL 4.6 or above: failovermode may be set to 1 for active/passive behavior, or RHEL 4.6 or above: failovermode may be set to 4 for ALUA behavior RHEL 4.5 or below: failovermode MUST be set to 1 - RedHat RHEL 5.x: RHEL 5.1 or above: failovermode may be set to 1 for active/passive behavior, or RHEL 5.1 or above: failovermode may be set to 4 for ALUA behavior RHEL 5.0: failovermode MUST be set to 1 - Asianux: Asianux 3.1 or above: failovermode may be set to 1 for active/passive behavior, or Asianux 3.1 or above: failovermode may be set to 4 for ALUA behavior Asianux 3.0: failovermode MUST be set to 1 - Other Linux distributions: failovermode MUST be set to 1 11. For for Solaris, Linux and Windows, failovermode settings are as follows: Page 6 of 9 December 20, 2010

- 5.0 or earlier: failovermode MUST be set to 1-5.1 or later: failovermode may be set to 4 for ALUA behavior, or - 5.1 or later: failovermode may be set to 1 for active/passive behavior 12. For Solaris MPxIO or STMS, failovermode settings are as follows: - Solaris 9 with SAN 4.4.7 thru 4.4.11: failovermode MUST be set to 1 - Solaris 9 with SAN 4.4.12 or later: failovermode may be set to 1 for active/passive behavior, or - Solaris 9 with SAN 4.4.12 or later: failovermode may be set to 4 for ALUA behavior - Solaris 10 U2 or earlier: failovermode MUST be set to 1 - Solaris 10 U3 or later: failovermode may be set to 1 for active/passive behavior, or - Solaris 10 U3 or later: failovermode may be set to 4 for ALUA behavior Note: Use of failovermode = 4 (ALUA) with MPxIO/STMS cannot be supported with clustering environments requiring SCSI2 Reservations such as 2 node Sun Clusters, except for CX4 arrays operating with FLARE 04.28.000.5.704 or later. 13. For AIX installations using VERITAS VxVM, set failovermode as follows: VERITAS VxVM 4.x or 5.x, with : failovermode MUST be set as required by VERITAS VxVM 4.x without : failovermode MUST be set to 2 VERITAS VxVM 5.0 MP1-RP3 or later, but prior to MP3-RP2: failovermode must be set to 1. Required for CLARiiON NDU support. VERITAS VxVM 5.0 MP3-RP2 or later: failovermode must be set to either 1 (active/passive) or 4 (ALUA). Required for CLARiiON NDU support. 14. For HP-UX installations using VERITAS VxVM, set failovermode as follows: VERITAS VxVM 4.x or 5.x, with : failovermode MUST be set as required by VERITAS VxVM 4.x or 5.x without : o VxVM 4.x (11i v1 and 11i v2): failovermode must be set to 2 o VxVM 5.x (11i v2): non-clustered hosts: failovermode can be set to either 1 or 2 clustered hosts: failovermode must be set to 1 15. For for HP-UX, failovermode settings are as follows: o 5.1 or earlier: failovermode MUST be set to 1 o 5.1.1 or later: For HP-UX 11i v1 or v2: failovermode MUST be set to 1 For HP-UX 11iv3: failovermode MUST be set to 4 Page 7 of 9 December 20, 2010

16. For for VMware, failovermode settings are as follows: - Failovermode is recommended to be set to 4 for ALUA behavior or - Failovermode may be set to 1 for active/passive behavior 17. For VMware native failover, failovermode settings are as follows: CX and CX3 series arrays: failovermode MUST be set to 1 CX4 arrays operating with FLARE revisions prior to 04.28.000.5.704: failovermode MUST be set to 1 CX4 arrays operating with FLARE 04.28.000.5.704 or later: - ESX 2.x or 3.x: Failovermode MUST be set to 1 - ESX 4.0 or above: Failovermode is recommended to be set to 4 for ALUA behavior or Failovermode may be set to 1 for active/passive behavior 18. For using DMP within VERITAS Storage Foundation for Windows, set failovermode as follows: VERITAS VxVM 5.0 and earlier, failovermode MUST be set to 1 VERITAS VxVM 5.1 and above: failovermode settings are as follows: FLARE 24 or earlier: failovermode MUST be set to 1 FLARE 26 or later: Failovermode is recommended to be set to 4 for ALUA behavior, or Failovermode may be set to 1 for active/passive behavior 19. For AIX MPIO, set failovermode as follows: For AIX 5.x AIX 5.2, 5.3 TL8 SP7 (5300-08-07) and earlier: failovermode MUST be set to 1 AIX 5.3 versions 5300-08-08, 5300-09-05, 5300-10-02, 5300-11 and later: FLARE 28 or earlier: failovermode MUST be set to 1 FLARE 29 or later: Failovermode is recommended to be set to 4 for ALUA behavior, or Failovermode may be set to 1 for active/passive behavior For AIX 6.x AIX 6.1 TL1 SP5 and earlier: failovermode MUST be set to 1 AIX 6.1 versions 6100-01-06, 6100-02-05, 6100-03-02, 6100-04 and above: FLARE 28 or earlier: failovermode MUST be set to 1 FLARE 29 or later: Failovermode is recommended to be set to 4 for ALUA behavior, or Failovermode may be set to 1 for active/passive behavior 20. When using VERITAS VxVM 5.x thin LUN reclamation feature with HP-UX 11i v3, initiator type MUST be set to CLARiiON open. Page 8 of 9 December 20, 2010

21. FLARE Release 28 and 29: Failover mode 1 must be used for VMS hosts. FLARE 30 and later: Failover mode 4 is recommended for all VMS clusters, and non-clustered hosts running VMS V8.3 or higher. Failover can be either 1 or 4 for non-clustered hosts running lower than VMS V8.3 Page 9 of 9 December 20, 2010