MANUAL Surge Protectors

Similar documents
PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

MANUAL MODULAR SEGMENT PROTECTOR

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

MANUAL LML-P, LML-S, LML-Ex

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS

Operating Instructions

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

PROCESS AUTOMATION. MANUAL Compact Fieldbus Power Hub, Common Interface

MANUAL SEGMENT CHECKER

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

PI-EX-ME-2NAM/COC-24VDC

Safety Instructions Cerabar M PMC51, PMP51, PMP55

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

PROCESS AUTOMATION MANUAL F2-SP-IC*

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

MANUAL Functional Safety

MANUAL Temperature Multi-Input Device

Safety instructions Overvoltage protection B81-35

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

MANUAL Functional Safety

SMARTLINE RM76 Supplementary instructions

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

5 Fieldbus Technology

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

MANUAL FieldConnex Basic Segment Coupler

FLEX Ex Spring Clamp Terminal Base

MANUAL Functional Safety

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Operating instructions

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

SAFETY MANUAL SIL Switch Amplifier

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

DR7100 SERIES Supplementary instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

SYSTEM DESCRIPTION H-System

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 01/2008

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

TRIO-DIODE/12-24DC/2X10/1X20

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Installation & Operation Manual

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Zener Barriers Bulletin 937Z

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Safety Instructions Cerabar S PMP71, PMP75

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

MANUAL Functional Safety

MACX MCR-EX-SD LP(-SP)

Operating Instructions

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

ETD-BL-1T-OFF-CC- 10S

FF Physical Layer Components

BLITZDUCTOR XTU Universal lightning current / surge arrester

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

PROCESS AUTOMATION MANUAL. Temperature Converter. HiC2081, HiD2081, HiD2082 ISO9001

M E M O R A N D U M I.S.

Inductive sensor with analog output BI15-M30-LI-EXI

PHOENIX CONTACT - 02/2008

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Installation Instruction. HART Add-On Module

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

Intrinsically safe batch controller Batching Master 110i

Refer to attachment for more details. Andreas Meyer

Redundancy unit CP-A RU

SolConeX extra-low voltage flange socket

CompactBlock Guard I/O EtherNet/IP Safety Modules

MINI-PS AC/10-15DC/8

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

SolConeX Wall-Mounted Socket, 16 A

Transcription:

PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents 1 Safety... 4 1.1 Validity...4 1.2 Symbols used...4 1.3 System Operator and Personnel...4 1.4 Pertinent Laws, Standards, Directives, and further Documentation...5 1.5 Delivery, Transport and Storage...5 1.6 Marking...5 1.7 Intended Use...6 1.8 Mounting and Installation in Hazardous Areas...6 1.9 Housing...7 1.10 Repair and Maintenance...7 1.11 Disposal...7 2 Product Specifications... 8 2.1 Overview and Application...8 2.2 Component Overview...8 2.3 Technical Data...12 2.4 Dimensions...14 3 Installation and Commissioning... 15 3.1 Mounting...15 3.2 Connection...16 3.3 Shielding and Grounding the Cable Shield...17 4 Dismounting the Surge Protector... 18 3

Safety 1 Safety 1.1 Validity Specific processes and instructions in this document require special precautions to guarantee the safety of the operating personnel. 1.2 Symbols used This document contains information that you must read for your own personal safety and to avoid property damage. Depending on the hazard category, the warning signs are displayed in descending order as follows: Safety-relevant symbols Danger! This symbol indicates a warning about an immediate possible danger. In case of ignoring the consequences may range from personal injury to death. Warning! This symbol indicates a warning about a possible fault or danger. In case of ignoring the consequences may cause personal injury or heaviest property damage. Caution! This symbol indicates a warning about a possible fault. In case of ignoring the devices and any connected facilities or systems may be interrupted or fail completely. Informative symbols Note! This symbol brings important information to your attention. Action This symbol indicates a paragraph with instructions. 1.3 System Operator and Personnel The plant owner is responsible for its planning, installation, commissioning, operation, maintenance and disassembly. Mounting, installation, commissioning, operation, maintenance and disassembly of any devices may only be carried out by trained, qualified personnel. The instruction manual must be read and understood. 4

Safety 1.4 Pertinent Laws, Standards, Directives, and further Documentation Laws, standards, or directives applicable to the intended use must be observed. In relation to hazardous areas, Directive 1999/92/EC must be observed. The corresponding data sheets, declarations of conformity, EC Type-examination certificates, certificates and Control Drawings if applicable (see data sheet) are an integral part of this document. You can find this information under www.pepperl-fuchs.com. Due to constant revisions, documentation is subject to permanent change. Please refer only to the most up-to-date version, which can be found under www.pepperl-fuchs.com. 1.5 Delivery, Transport and Storage 1.6 Marking Check the packaging and contents for damage. Check if you have received every item and if the items received are the ones you ordered. Keep the original packaging. Always store and transport the device in the original packaging. Always store the device in a clean and dry environment. The permitted storage temperature (see data sheet) must be considered. Certificates and approvals Pepperl+Fuchs KEMA 09 ATEX 0190 X DP-LBF-I1.36.IE DP-LBF-I1.36.DE Fisco Surge Protection II 2(1)G Ex ia IIC T4/T5/T6 KEMA 09 ATEX 0191 X II 3G Ex ic IIC T4/T5/T6, II 3G Ex na II T4/T5/T6 IECEx KEM 09.0088X Ex ia [ia Ga] IIC T4/T5/T6 Gb, Ex ic IIC T4/T5/T6 Gc Ex na IIC T4/T5/T6 Gc CSA 2437472 Class I, Zone 1, AEx/Ex ia IIC T4 T6 Class I, Zone 2, AEx nc IIC T4 T6 Class I, Zone 2, Ex nl IIC T4 T6 Class I, Zone 2, AEx/Ex na IIC T4 T6 Class I Div. 1, GP A, B, C, D T4 T6 Class I Div. 2, GP A, B, C, D T4 T6 Class I Div. 2, GP A, B, C, D T4 T6 5

Safety 1.7 Intended Use The modular FieldConnex Surge Protectors protect fieldbus equipment safely from damages caused by surge voltages or lightning strikes. The surge protectors are designed for use in the fieldbus communication system according to IEC 61158-2 as Foundation Fieldbus and PROFIBUS PA. Both versions DP-LBF-I1.36.DE and DP-LBF-I1.36.IE are suitable for mounting in Zone 1 or Zone 2. The associated apparatus circuit may be led into Zone 0 if the intrinsically safe fieldbus power circuit is certified accordingly. It can also be used in intrinsically safe fieldbus installations in accordance with the FISCO and Entity model, as well as in DART fieldbus systems by Pepperl+Fuchs. The surge protectors are mountable on a DIN mounting rail only. For use in hazardous areas Class I Div 1, Class I Zone 1, Class I Div 2, and Class 1 Zone 2 refer to installation drawing 116-0361. 1.8 Mounting and Installation in Hazardous Areas The surge protectors may be used in intrinsically safe fieldbus systems according to the FISCO or Entity concept. The surge protector itself may be installed in hazardous area Zone 2 and Zone 1, Gas Groups IIC, IIB, IIA. Connection between a surge protector and earth must have a minimum core cross section of 4 mm 2. If the fieldbus cable of a surge protector leads into Zone 0, the cable length must be limited to 1 meter. If led into Zone 0, the fieldbus cable must be protected against interferences caused by lightning. The shield of the fieldbus cable must not lead into Zone 0 if it is not safely earthed like an equipotential bonding conductor according to IEC 60079-14. All separation distances between two adjacent intrinsically safe circuits need to be observed in accordance with IEC/EN 60079-14. All separation distances between two adjacent intrinsically safe circuits need to be observed in accordance with IEC/EN 60079-14. The lines connected to the surge protector must be shielded or covered by a metal coating or be passed within a metal pipe. The dielectric strength of at least 500 V of the intrinsically safe circuit of the device is limited only by the overvoltage protection. The terminals 5, 6, 7, and 8 are considered to be connected to earth. The device has to be installed into a metal housing, or into a housing that is certified for this kind of use. When the device is used in a fieldbus system according to FISCO, the power supply must have infallible galvanic isolation and may not be connected to earth. Alternatively the power supply must be infallibly connected to the potential equalizing system within the hazardous area. For use in the types of protection Ex na IIC T4... T6 and Ex na IIC T4... T6 Gc the device must be installed in an enclosure see chapter 1.9. 6

Safety The installation instructions in accordance with IEC/EN 60079-14 must be observed. 1.9 Housing Instructions for Zone 1 The devices may only be installed and operated in zone 1 if mounted in an enclosure for which an EC-type-examination certificate according to 94/9/EC for at least category 2G exists. Instructions for Zone 2 The devices may only be installed and operated in zone 2 if they have been mounted in an enclosure with degree of protection IP 54 according to IEC/EN 60529. The enclosure must have a declaration of conformity according to 94/9/EC for at least category 3G. Instructions for Zone 21 The devices may only be installed and operated in a hazardous areas requiring equipment protection level Db (Zone 21) if mounted in an enclosure for which an EC-type-examination certificate according to 94/9/EC for at least equipment protection level Db (category 2D) exists. Instructions for Zone 22 The devices may only be installed and operated in zone 22 if mounted in an enclosure for which an EC-type-examination certificate acc. 94/9/EC for at least category 3D exists. For use in hazardous areas Class I Div 1, Class I Zone 1, Class I Div 2, and Class 1 Zone 2 refer to installation drawing 116-0361. If additional housings are needed for installation in hazardous areas, the following points must be considered / evaluated: To ensure the IP degree of protection: all seals must be undamaged and correctly fitted all screws of the housing / housing cover must be tightened with the appropriate torque only cable of the appropriate size must be used in the cable glands all cable glands must be tightened with the appropriate torque all empty cable glands must be sealed with sealing plugs 1.10 Repair and Maintenance 1.11 Disposal The devices must not be repaired, changed or manipulated. If there is a defect, the product must always be replaced with an original device. Disposing of devices, packaging material, and possibly contained batteries must be in compliance with the applicable laws and guidelines of the respective country. 7

Product Specifications 2 Product Specifications 2.1 Overview and Application The FieldConnex Surge Protector protects fieldbus components and control units from damage caused by voltage surges and lightning strikes. Voltages between the fieldbus leads 'plus' and 'minus', and between either lead and ground are limited safely. The surge protector is designed for use in fieldbus communication topologies according to IEC 61158-2. It conforms to IEC 60079: FISCO and Entity concepts and is DART-enabled. The surge protector allows the coordinated use in an EMC-oriented Lightning Protection Zones Concept in accordance with IEC 61312-1. The protective effect is adapted to the EMC interference immunity (conducted high energy interference impulses) for fieldbus measuring, control, and equipment. The FieldConnex Surge Protector consists of a base part and a protection module. It can be configured according to the maintenance concept of the plant with choices of modules as shown in the following table: Type Code Module Type Comment Application On removal of protection module DB-LBF-I1 Base communication continues DB-LBF-I1.I Base communication interrupts Replacement of the protection module during operation Replacement of the protection module only offline Connection of shield to earth... DP-LBF-I1.36.DE Protection... direct For double-sided grounding DP-LBF-I1.36.IE Protection... via gas discharge tube For single-point grounding Table 2.1 FieldConnex Surge Protector Components and Attributes Base parts and protection modules are separately available. The two grounding methods support all cable shield grounding concepts used in fieldbus applications today. 2.2 Component Overview The modular surge protector DP-LBF-I1* always consists of two parts: Base part Protection module The two protection modules may be combined with two different base parts with or without communication interruption while the protection module is removed. 8

Product Specifications 1 2 1 Base part 2 Protection module DP-LBF-I1.36* Protection Module Overview The protection module contains the electronic components, e.g., the gas discharge tube to provide surge protection. In the event of a surge or lightning strike, the DP-LBF-I1.36.IE module discharges both leads and the cable shield to earth. In normal operation, the shield is isolated from earth. For fieldbus installation where single-point grounding in the control room is required, the DP- LBF-I1.36.IE protection module is used at the coupler's end on trunk and spur. The DP-LBF-I1.36.DE module connects the fieldbus cable shield directly to earth. Part name Description DP-LBF-I1.36.DE Fieldbus cable shield connects directly to earth DP-LBF-I1.36.IE Fieldbus cable shield connects indirectly to earth via gas discharge tube (GDT) 9

Product Specifications DP-LBF-I1.DE + 2 Bus - 1 4 3 protected Shield 6 8 Earth 5 7 Figure 2.1 DP-LBF-I1.36.DE DP-LBF-I1.IE + 2 Bus - 1 4 3 protected Shield 6 8 Earth 5 7 Figure 2.2 DP-LBF-I1.36.IE 10

Product Specifications DB-LBF-I1* Base Part Overview The DB-LBF-I1* base parts serve as mechanical support for the DP-LBF-I1.36* protection modules. Electronic modules lead surge currents through the base parts to the DIN rail. Provided the DIN rail is installed isolated from earth, a dedicated terminal allows to connect the earth via an external wire to the base module. The DB-LBF-I1 version keeps the communication with the signal lines up while the electronic module is removed from the base module. The DB-LBF-I1.I version interrupts communication with the signal lines when the electronic module is removed. Part name DB-LBF.I1 DB-LBF.I1.I Description Base part without signal interruption during removal of the protection module. Base part with signal interruption during removal of the protection module. 2 6 1 5 3 7 4 8 protected 1 5 3 7 protected 2 6 4 8 Figure 2.3 DB-LBF-I1 11

Product Specifications 2 6 1 5 3 7 4 8 protected 1 5 3 7 protected 2 6 4 8 Figure 2.4 DB-LBF-I1.I 2.3 Technical Data DP-LBF-I1.36* Electrical specifications Rated voltage Rated current Continuous voltage U C 33 V 500 ma max. 36 V Impulse durability Per line 1 ka category D1 10/350µsec, 5 ka category C1/C2 8/20µsec Screen/Shield direct grounded 5 ka category D1 10/350µsec Screen/Shield indirect grounded (via GDT) 4 ka category D1 10/350µsec, 10 ka category C1/C2 8/20µsec Standard conformity Protection degree IEC 60529 Fieldbus standard IEC 61158-2 Climatic conditions IEC 60721 Shock resistance EN 60068-2-27 Ambient conditions Ambient temperature -50... 80 C (-58... 176 F) Storage temperature -50... 85 C (-58... 185 F) 12

Product Specifications DP-LBF-I1.36* Relative humidity Shock resistance Vibration resistance Mechanical specifications Connection type 95 % non-condensing 15 g 11 ms 1 g, 10... 150 Hz screw terminals Core cross-section flexible wire 2.5 mm 2 solid wire max. 4 mm 2 Housing material Polyamide PA 6.6 Protection degree IP20 Mass protection module 20 g, base module 40 g Mounting 35 mm DIN mounting rail Data for application in connection with Ex-areas EC-Type Examination Certificate KEMA 09 ATEX 0191 X Group, category, type of protection, temperature class II 2(1)G Ex ia IIC T4/T5/T6 Voltage U i 30 V Current I i 500 ma Internal capacitance C i negligible 0 nf Internal inductance L i negligible 0 µh Statement of conformity KEMA 09 ATEX 0190 X Group, category, type of protection, temperature class II 3G Ex ic IIC T4/T5/T6, II 3G Ex na II T4/T5/T6 Voltage U i 33 V Current I i 500 ma Internal capacitance C i negligible 0 nf Internal inductance L i negligible 0 µh Ambient conditions Ambient temperature -50... 80 C (-58... 176 F) T4, -50... 75 C (-58... 167 F) T5, -50... 50 C (-58... 122 F) T6 Directive conformity Directive 94/9/EC EN 60079-0:2006, EN 60079-11:2007, EN 60079-15:2005, EN 60079-26:2007, EN 60079-27:2008 13

Product Specifications 2.4 Dimensions 7 43 90 45 12 65,5 14

Installation and Commissioning 3 Installation and Commissioning 3.1 Mounting Warning! Electrostatic charge Electrostatic charged surfaces may cause an ignition spark. Clean surfaces with a damp cloth to prevent electrostatic charge. Mounting the Base Part on a DIN Rail The surge protectors are to be mounted on a 35 mm Din rail compliant with DIN EN 60715. 1. Place the base part on the DIN rail 2. Gently press the base part to the DIN rail until it is locked in place min. 4 mm 2 / min. AWG 15

module module Surge Protectors Installation and Commissioning Mounting the Protection Module 1. Carefully insert the protection module into the base part. 2. Press until the protection module is locked in place. Ensure that there is no space left between the protection module and the base part. 1 2 click 3.2 Connection max. 0,4 Nm size 0 max. 2,5 mm 2 3,5 in-ibs AWG 14 Note! Keep the cable for connecting the protected field device as short as possible. 16

Installation and Commissioning 3.3 Shielding and Grounding the Cable Shield Cable Shield: Direct Grounding Cable Shield: Indirect Grounding 1 2 5 6 1 2 5 6 17

module Surge Protectors Dismounting the Surge Protector 4 Dismounting the Surge Protector Dismounting the Protection Module 1. Push down the quick-lock taps 2. Hold the quick-lock taps and pull off the protection module 1 2 1 Dismounting the Base Part 1. Lift up the latch with a screwdriver 2. Pull off the base part from the DIN rail 18

PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany TDOCT-2096_ENG 11/2012