Mercury Emissions Stack Monitor

Similar documents
Thermal DC-DC Control System TEC Series

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

Industrial IT Laboratory Work Hans-Petter Halvorsen

Estates & Facilities Utilities Meters - Performance Specification

Breaking the Limits of Analog Technology. Key attributes of the technology that makes FOUNDATION fieldbus suitable for process control

To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls.

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

Accord Builder. User Guide

APPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants

Indicators. Product Mounting Display Height Page

WIRELESS REMOTE ASSET MONITORING & CONTROL

This document is for information purposes only and is subject to change without notice.

MULTI-FUNCTION PROCESS CONTROL TEACHING SYSTEM PCT40

Simplified Digital Connectivity using MODBUS TCP/IP for iseries Instruments. MODBUS Master Device (PLC, PC, Data logger, etc)

FloBoss TM 107/107E Flow Manager Overview

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments

GRYF. Measuring Instruments. measuring electrochemical and physical values. monitoring the environment. controlling technological processes

FBxConnect Configuration Software

Communication Interface

Advanced NI-DAQmx Programming Techniques with LabVIEW

XRC G Panel Mount XSeries G4 Products Remote Controller

BMS Steam Station Solutions

PORTABLE TRITIUM MONITOR Model # VAP-X-(H3)

Eurotherm advanced controllers providing solutions for simple to demanding applications...

FCU-4 FAN COIL CONTROLLER

Fisher ROC Serial Driver Help Kepware Technologies

Specification for temperature sensor calibration setup

Multiple control with Learning System Process Automation. MPS PA Compact Workstation & MPS PA Reactor Station

Solve Compliance, Integration & Process Challenges Using Rich Data From Your Instrumentation

GS828-H. GPRS Data Logger

Hydrogen Gas Smart Sensing Module. Features

HOBO State Data Logger (UX90-001x) Manual

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

HOBO State Data Logger (UX90-001x) Manual

Innovative hardware...

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

General Specifications

General Specifications

Self-Powered Wireless Instrumentation

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

WHAT YOU NEED TO KNOW ABOUT SCR POWER CONTROLLERS FUNCTIONS, FEATURES, AND EFFICIENCIES

TRITIUM COLLECTION SYSTEMS

Open, Scalable Real-Time Solutions

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations

WISE-4210 Engineering Sample SOP

OVEN INDUSTRIES, INC.

8 CHANNEL ANALOG DATA LOGGER

CHAPTER 3 LabVIEW REAL TIME APPLICATION DEVELOPMENT REFERENCES: [1] NI, Real Time LabVIEW. [2] R. Bishop, LabVIEW 2009.

A NEW DATA LOGGER Stand alone. Secure. Fast.

Foundation Fieldbus optimized for FPSO - CAPEX. Jonas Berge, Emerson Process Management

AcceptanceTestingofElectroHydraulicbasedAircraftActuatorusingLabVIEW

Continuous Ambient Air Quality Monitoring Systems Challenges & Recent Advances

Online data sheet MEAC CEMS SOLUTIONS

March 21, Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series. ROC 300 and 407 Customers,

MicroNet TMR Control System

Herculine Electric Actuator Solutions

W600/W900 Modbus. Instruction Manual

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Compact Controller M<CC-M>

Ethernet/Serial Interfaces for Compact FieldPoint

Automation systems. Scalable performance for every requirement

Propeller Control of Wind Tunnel Models

FP-1600 FieldPoint Quick Start Guide

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

DESCRIPTION OF MODBUS CONNECTION

PIECAL CALIBRATORS. Milliamp Thermocouple RTD Voltage Frequency.

Thermocouple Signal Conditioners

PACs for Industrial Control, the Future of Control

TSM1 Infrared Data Logger

The new generation of dedicated HVAC drives

Flow Computer. FloWEB

THE WATER MANAGEMENT SYSTEM

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Data Loggers, Sensors & Instrumentation

Instrumentation for Process Analytics

Alternative Energy. Connect, monitor and control diverse remote sites and processes. Applications Include: Wind Power Solar Power Hydro Power

Control Point Sprague RoadWatch Turck Sensor Adapter

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

DS October MAXIM 1010 Controller

Instruction Notes for 104A PL912 Photos below are for reference only. Outlet. Figure 1 Figure 2

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

WSDA User Guide

8B SLX300 Data Acquisition System

GE Measurement & Control. Calibration and Maintenance Solutions for the Power Sector

Operation of the Toxic Organic Chemical Air Monitor (TOCAM ) with the Ellvin Chromatography Software

FCU-4 FAN COIL CONTROLLER

Temperature / Humidity Controller for Stability Chamber

Converter station water-cooled pump vibration monitoring and. condition assessment system based on LabVIEW

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

Billion SG3030S. Billion SG3030. Three-phase Power Meter Series. Three-phase ZigBee Power Meter. Three-phase RS485 Power Meter.

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

w w w. z i g s e n s e. c o m. a u

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

General information. Display. Supply voltage. Input current

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

AUDIN - 8, avenue de la malle Saint Brice Courcelles - Tel : Fax : Web : http:

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

VR18 FAQs - Frequently Asked Questions

Transcription:

Mercury Emissions Stack Monitor by Timothy Nolan Engineer, Measurement & Automation Data Science Automation, Inc. USA Category: Control Products Used: cfp-2120 cfp-tc-120 cfp-ai-110 cfp-di-330 cfp-do-410 cfp-quad-510 cfp-pwm-520 LabVIEW 8.20 LabVIEW Realtime 8.20 LabVIEW PDA Module 8.20 The Challenge: Developing a reliable mercury emissions sampling system to provide the control, calibration and maintenance features required by stringent Federal regulations for coal fired power plants. Copyright, Data Science Automation, Inc. All Rights Reserved. Page 1 of 6

Figure 1. Typical coal fired power plant emissions stacks. The Solution: Creating a flexible, real time software architecture deployed to a Compact FieldPoint (CFP) Programmable Automation Controller (PAC) with a wireless communications interface to a PDA. The PDA provides all status display and operator interaction. The system saves data to the CompactFlash drive, and broadcasts data over an RS-485 serial connection to a data logger. Abstract: In order to comply with Federal Clean Air regulations, mercury emissions from coal-fired power plants (Figure 1). must be continuously monitored. The proportional measurement technique requires sampling rates to be continuously adjusted to remain in proportion with stack flow. In addition, all calibration, maintenance and leak checking modes must be automated. The system uses a Programmable Automation Controller (PAC) that operates remotely, controlling the sample collection for as much as a week. The only computer connection is an RS-485 output line to a data logger. Therefore, all control and programming of the PAC, as well as all user feedback, is through a wireless connection to a PDA, running National Instruments LabVIEW PDA module (Figure 2). Copyright, Data Science Automation, Inc. All Rights Reserved. Page 2 of 6

Figure 2. System network architecture. Sampling Mode: The full system controlled two sampling paths consisting of sampling pumps, leak check valves and proportional control valves operated through the pulse-width modulation cfp module. Immediately after connecting the Compact FieldPoint bank, we were able to test and troubleshoot all the hardware modules in the system. This allowed several design issues to be addressed very early in process, before the LabVIEW programming had become too specific. Data was to be collected at one-second intervals, with each collection of data broadcast over a serial connection to a remote system. The data was also averaged hourly, and these hourly averages were saved to non-volatile memory, as well as being used to adjust set points for flow and temperature control. All data was also compared with a series of alarm set points that would raise system flags or stop sampling during the alarm. The system needed to have the ability to enter and return from a suspended function during an alarm. The integrated RS-485 connection on the cfp-2120 allowed industrial serial communication, and the expanded memory of the CompactFlash slot enabled long-tem data storage for the system. Running simultaneously with the data collection, broadcasting and analysis were the control loops. A set of heaters were controlled by PID loops to maintain the sampling ports at constant temperature. Also, each flow path was controlled by its own PID controller in order to maintain the sampling flow at a constant ratio to changing stack flow rate. Each of these loops referenced user-defined set points in conjunction with measured values to maintain the flow and temperature at required values. PDA Connection: The remote location of the system, and lack of network connected meant that the device would run headless with no computer connection. The deployed executable communicated with a rugged PDA through a shared variable library, with the cfp-2120 as the shared variable server. The variables were network published, and an 802.11 wireless ethernet bridge connected to the cfp-2120 ethernet port to the wireless capability of the PDA. Both system commands and changes of program state were communicated through the PDA, which could also display and change system settings. Other than beginning the automated sampling mode described above, the PDA was used to operate several user-interactive modes. Calibration: Copyright, Data Science Automation, Inc. All Rights Reserved. Page 3 of 6

This mode would check all the built-in sensors of the system. The calibrations ranges in complexity from a simple comparison to standard in the thermocouple calibration, to an intricate, controlled-flow check of the Dry Gas Meters. All calibration data was stored locally on the PAC in LabVIEW configuration file format, as a.cal file. The most recent calibration values were retrieved from these files in order to convert and scale raw values read from the FieldPoint module in each sampling run. This is an example of a user input screen, where data is sent to the FieldPoint from the user. Leak Check: PDA calibration screen, for user input This was another automated check of the system used before each sampling run, used to verify the integrity of the sample path. The values were checked before and after each test, and the user could interact with the device to accept or repeat tests as necessary. This is an example of a user controlling system functions with the PDA, as the user only had press a button to begin a test, which was automated and repeatable. Copyright, Data Science Automation, Inc. All Rights Reserved. Page 4 of 6

PDA leak check screen, for system and automation control Maintenance: During maintenance mode, the user had full control of the system. This mode could turn on and off all pumps and valves, as well as read the current state or level of all the FieldPoint channels. In the mode, the user-defined functional set points could be entered, read or updated. During this mode the cfp-2120 system time would be automatically synchronized with the PDA to prevent divergence of timestamp values. Data Transfer: The two GB memory of the CompactFlash memory meant that several years of data could be accumulated on the system. For diagnostic procedures and record keeping, a transfer mechanism was set up to collect data files from the PAC to the PDA. The PDA would connect to the Compact FieldPoint, which would then populate a list with all the existing.dat or.cal files, any of which could be selected and copied through TCP protocol to local memory. The system also prevented currentlyused and unfinished data files from being transferred in the middle of a sampling run. Copyright, Data Science Automation, Inc. All Rights Reserved. Page 5 of 6

PDA data transfer screen, for selectable TCP file transfer Summary The success of the project was due to the processing and automation power of the cfp-2120, as well as the customer ease of use that derived from integrating the PDA control system. This streamlined the interface for the user, while allowing the automated processes to take care of most of the sampling functions. Speed was also enhanced by the cfp-2120 incorporating Ethernet and serial communication, as well as expandable memory, which saved time by avoiding excess hardware integration and troubleshooting. Copyright, Data Science Automation, Inc. All Rights Reserved. Page 6 of 6