Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Similar documents
Applications

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Transforming customer wishes into concrete solutions

HARTING Connectors for High Mating Cycles

Standard Hoods/Housings Han B Size 16 B

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

07. har-link Interface Connectors

Details of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

07. har-link INTERFACE CONNECTORS

07. har-link Interface Connectors

Technical data: Pin Spacing

Extract from new. Device Connectivity catalogue. HARTING har-flex. People Power Partnership

HARTING. News People Power Partnership

HARTING News 2007

HARTING. News People Power Partnership

02. PushPull CONNECTORS

EPIC Circular Connectors CIRCON M23 Series

revos revos Industrial Multipole Connectors

09. DIN Connectors

Description of parts Panel mounting Insert mounting without/with Carrier element Plastic housings

HARTING Rugged Indoor/Outdoor Light & Sound connections

VMEbus systems System description Technical characteristics System description

09. DIN CONNECTORS

02. PushPull CONNECTORS

HARTING. News People Power Partnership

Item No.: /

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Data sheet. OMNIMATE Signal - series B2L/S2L row S2L-SMT 3.50/08/180G 3.5SN BK BX

M23 Connectors and cables

EPIC LS1 Series Circular Power & Mixed Power Connectors

Transforming customer wishes into concrete solutions

Data sheet... OMNIMATE Power - series BL/SL 7.62HP BLZ 7.62HP/04/180LR SN BK BX

Right angle press-fit D-Sub connectors

ODU MAC LC. Modular Attachable Connector System

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Powermate Range pitch 10.16

Male header, 100% protected against mismating, (1 x 1) mm straight solder pins Pin spacing 3.5 mm 3.81 mm. light gray <_ 8,5_> 3,5 1x1 <_ 9,3_>

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

Through-Board SMD PCB Terminal Block; 0.75 mm² Pin Spacing: 6.5 mm 2070 Series

Datasheet. Datasheet-No Type: RS(W)T(S) - RK(W)T(S) -.../ M. Page: 1 of 7

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Male connector; 6-pole; pin spacing 3.5 mm / in; 100% protected against mismating

Electrical Interconnection

Electrical Interconnections. Supplementary Catalog to Full Line Catalogs, Volumes 1/2/5 Edition 2012/2 1/2/5

ODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic

2.54 mm Single Row Connector (SRC) MaxiBridge.

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

VARIOSUB D-SUB 25 Contact Inserts, Sleeve Housings

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

1-Conductor Female Connector with Levers Pin Spacing: mm MCS MAXI 16

High-density multi-pin connectors

ITS-Z0344 Half Pitch Interface Connectors

Miniature Push-Pull Series Atto Miniature Push-Pull

2.54 mm Single Row Connector (SRC) MaxiBridge.

Multipole Industrial Connectors Heavy duty connectors

Summary of shell housings and accessories Shell housing A Shell housing D EMC housing

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Ø 36 Ø 34 Ø 3,5 Ø 3,5

Male connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting

Limanda. Technical data

Section 2. Connectors Field attachable

Modular Connector System with High Power, Signal, Fibre-Optic, Coaxial Contacts and Pneumatic Valves

Amphenol Amphenol-Tuchel Electronics GmbH. heavy mate. Heavy Duty Connectors.


ODU DOCK and ODU ROB. Connectors for Docking and Robot Systems.

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

HARTING Device Connectivity PushPull

CX BD series. Main features MULTIPOLE CONNECTORS CX BD CN

High-density multi-pin connectors

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications

Item No.: /

DUBOX SHUNTS BOARD/WIRE-TO-BOARD CONNECTORS FEATURES & BENEFITS. Dual-beam contacts for added reliability

Item No.: /

SMD PCB Terminal Blocks We Connect Your Light

IDC Assembly (depends on cable) -55/125 C. IDC Assembly (depends on cable) By ambient temperature: 20 C 1,2 A 70 C 0,9 A 100 C 0,6 A

HARTING Han-Power Power Networks and Industrial Cabling

Standard Buccaneer BUCCANEER FOR POWER

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

PCB Keyswitches Product Survey Versions Recommended Key grid Illumination Keyswitch Signal indicator Keyswitch height Contacts RACON 8 12 mm Non-illum

M 12 POWER THE COMPACT AND POWERFUL M 12 CONNECTOR

SMD PCB TERMINAL BLOCKS We Connect Your Lights

v1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc.

SMD Terminal Blocks Small is Big

Surface Mount Terminal Blocks with Push-Buttons

HARTING. Interface Connectors. People Power Partnership

Limanda. Technical data

Connectors. product catalog no. 26

Small Circular Connector. JN1/JN2 Series. Cap

DRAGONFLY. Positronic Industries. Interconnection Systems. High Density Signal and Power Connectors.

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Electrical Test voltage (Vrms) Service sea level at m M I II

#redcube. REDCUBE PRESS-FIT REDCUBE PLUG REDCUBE SMD REDCUBE THR

Packing density, redefined mm pitch, 2 rows more convenience despite the small pitch

SAC-5P-MS/ 1,0-920/FS SCO

SMD PCB TERMINAL BLOCKS We Connect Your Lights

Data sheet. HDC insert HDC HQ 7 FC

Sales: Technical: Fax:

Transcription:

Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han Q 4/2... 20.22 adapter for Han Q 5/0... 20.25 adapter for Han Q 7/0... 20.28 adapter for Han Q 8/0... 20.31 adapter for Han Q 12/0... 20.34 1

adapter for Han DD Layout of Han 24 DD Han 42 DD Han 72 DD Han 108 DD Recommended hole diameter: 0.8 mm Assembly situation ➀ adapter ➁ Printed circuit board () ➂ Switch board panel ➃ Han DD double contact ➄ Han DD insert ➅ Han B bulkhead mounted housing 1) for Han B EMC housings spacing of 12.5 ± 0.2 mm is necessary as no flange seal is used 2

adapter for Han-Modular Layout of ➀ Recommended hole diameter: 0.8 mm ➁ Recommended hole diameter: 3.2 mm Han DD module Han 40 A module Assembly situation ➀ Han DD -adapter ➁ Han C solder contact ➂ Switch board panel ➃ Module for connection to printed circuit board ➄ Han D double contact ➅ Han B bulkhead mounted housing 1) for Han B EMC housings spacing of 12.5 ± 0.7 mm is necessary as no flange seal is used 3

adapter for Han DDD module Layout of 1 1 2 1 Recommended hole diameter: 0.8 mm 2 Recommended hole diameter: 3.2 mm Han DDD module Han DD module Han 70 A module Assembly situation 1 Han DDD adapter 5 pins 2 Han B bulkhead mounted housing 3 Switch board panel 4 Han D double male contact, 09 15 000 6197 5 Han D double female contact, 09 15 000 6291 1) for Han B EMV hood and housing spacing of 12.5 ±0.7 mm is necessary as no flange seal is used. For further information and Han-Modular frames please refer to chapter 06 (Han-Modular ) 4 for more technical details see chapter 06

adapter for Han E Layout of Han 6 E Han 10 E Han 16 E Han 24 E Assembly situation ➀ adapter ➁ Printed circuit board () ➂ Switch board panel ➃ Han E double contact ➄ Han E insert ➅ Han B bulkhead mounted housing 1) for Han B EMC housings spacing of 12.5 ± 0.7 mm is necessary as no flange seal is used 5

adapter for Han Q 4/2 Layout of Assembly situation X = 16 +1 with signal contact or 16 +2 without signal contact ➀ Printed circuit board () ➁ adapter ➂ Switch board panel ➃ Han-Compact bulkhead mounted housing ➄ Han C double contact ➅ Han Q 4/2 insert 6

adapter for Han Q 5/0 Layout of 1 ➀ Recommended hole diameter: 2.6 mm ➁ Recommended hole diameter: 1.5 mm 2 Assembly situation ➀ Han 3 A bulkhead mounting housing ➁ Han Q 5/0 ➂ Solder contacts ➃ adapter ➄ Connection to printed circuit board 7

adapter for Han Q 7/0 Layout of ➀ Median plane of the housing ➁ Recommended hole diameter: 0.8 mm Assembly situation ➀ adapter ➁ Printed circuit board () ➂ Switch board panel ➃ Han D double contact ➄ Han Q 7/0 Insert ➅ Han 3 A bulkhead mounting housing 8

adapter for Han Q 8/0 Layout of Assembly situation ➀ Printed circuit board () ➁ adapter ➂ Switch board panel ➃ Han-Compact bulkhead mounted housing ➄ Han E double contact ➅ Han Q 8/0 Insert 9

adapter for Han Q 12/0 Layout of Recommended hole diameter: 0.8 mm Assembly situation Han 3 A Standard / EMC Han 3 A plastic Han 3 A HPR ➀ Han Q 12/0 connector ➁ Han 3 A housing bulkhead mounting ➂ R15-double contact ➃ Printed circuit board () ➄ adapter ➅ Switch board panel 10

Han-Fast Lock Features Solder free termination contact with locking element Machine processing Flexible in terms of applications Practical and easy handling Fast assembly to Contacts with pin: locking directly on the Contacts without pin: fast positioning with plastic adapter Derating Current carrying capacity The current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature. Measuring and testing techniques acc. to IEC 60512-5-2 Operating current (A) Technical characteristics Material (locking lever) Material (contact) Details Board thickness 1.6... 3.2 mm copper alloy, surface finish: passivation copper alloy Clearance and creepage distances have to be considered for the printed circuit board Stripping length 7.5 mm Finished hole d= 4.4 mm +0.05/-0.04 The new connection of wires to the offers optimized design, combined with outstanding contact qualities. The Han-Fast Lock is flexible and allows a fast and simple connection. The has one drilled hole and a pad. The inner surface of the plated drilled hole serves as the interface. The Han-Fast Lock is simply inserted into the plated through contact hole. The locking pin is pushed in and hence locks the contact into position. The solder free connection technique is easy to handle and to operate. Maintenance has been made simple with the facility to detach the contact. Han-Fast Lock also supports SMD assembly of the. Current up to 60 Amps Standard drilled hole with pad Position independent of connector Solder free termination Easy locking solution Pull out force 340 N Ambient temperature (C ) 1 Wire cross section 4 mm² 2 Wire cross section 6 mm² 3 Wire cross section 10 mm² 11

Han-Fast Lock Identification Wire cross section (mm²) Part number Drawing Han-Fast Lock, Single contact, without pin, silver plated contacts, contact resistance <2 mohm 4 6 10 09 08 000 7923 09 08 000 7924 Han-Fast Lock, Contacts on a reel, without pin, silver plated contacts, contact resistance <2 mohm 4 6 10 09 08 000 6923 09 08 000 6924 Han-Fast Lock, Single contact, with pin, silver plated contacts, contact resistance <2 mohm 4 6 10 09 08 000 7123 09 08 000 7124 Han-Fast Lock, Single contact, with angled pin, silver plated contacts, contact resistance <2 mohm 1.5 2.5 09 08 000 7222 Han-Fast Lock, Contacts on a reel, with pin, silver plated contacts, contact resistance <2 mohm 4 6 10 09 08 000 6123 09 08 000 6124 12

adapter for Han DD Features Robust design Suitable for standard and EMC housings Low wiring costs High density of contacts Technical characteristics Electrical data acc. to IEC 7.5 A 250 V 4 kv 3 61984 Rated current 7.5 A Rated voltage 250 V Rated impulse voltage 4 kv Pollution degree 3 Material (insert) polyamide Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984 Details Crimping tools see chapter 90 Modules see chapter 06 Han DD crimp inserts see chapter 02 Han B housings (bulkhead mounting) see chapter 31 13

adapter for Han DD crimp inserts Identification Han D, to connect the adapter, Double contact, silver plated contacts, contact resistance 3 mohm Part number male female 09 15 000 6191 09 15 000 6291 Drawing adapter, for s up to 1.6 mm, in the Han DD crimp insert, in the Han DD module, in the Han DDD module (different electrical data: 7.5 A 160 V 2.5 kv 3) 09 16 000 9905 09 16 000 9905 09 16 000 9905 a= 2.6 09 16 000 9908 a= 3.4 adapter, for s up to 2.4 mm, in the Han DD crimp insert, in the Han DD module 09 16 000 9908 09 16 000 9908 14

adapter for Han DD module Identification Han D, to connect the adapter, Double contact, silver plated contacts, contact resistance 3 mohm Part number male female 09 15 000 6191 09 15 000 6294 Drawing adapter, for s up to 1.6 mm, in the Han DD crimp insert, in the Han DD module, in the Han DDD module (different electrical data: 7.5 A 160 V 2.5 kv 3) 09 16 000 9905 09 16 000 9905 09 16 000 9905 a= 2.6 09 16 000 9908 a= 3.4 adapter, for s up to 2.4 mm, in the Han DD crimp insert, in the Han DD module 09 16 000 9908 09 16 000 9908 15

adapter for Han DDD module Features Robust design Suitable for standard and EMC housings Low wiring costs High density of contacts Technical characteristics Electrical data acc. to IEC 61984 7.5 A 160 V 2.5 kv 3 7.5 A 250 V 4 kv 3 Rated current 7.5 A Rated voltage 160 V, 250 V Rated impulse voltage 2.5 kv, 4 kv Pollution degree 3 Material (insert) polyamide Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984 Details Crimping tools see chapter 90 Modules see chapter 06 For a 17 pin termination with the Han DDD module two 6 pin and one 5 pin adapters are necessary. (electrical data: 7.5 A 160 V 2.5 kv 3) 16

adapter for Han DDD module Identification Han D, to connect the adapter, Double contact, silver plated contacts, contact resistance 3 mohm Part number male female 09 15 000 6197 09 15 000 6291 Drawing adapter, 5 pins, for s up to 1.6 mm, in the Han DDD module 09 16 000 9915 09 16 000 9915 adapter, for s up to 1.6 mm, in the Han DD crimp insert, in the Han DD module, in the Han DDD module (different electrical data: 7.5 A 160 V 2.5 kv 3) 09 16 000 9905 09 16 000 9905 09 16 000 9905 a= 2.6 09 16 000 9908 a= 3.4 17

adapter for Han 40 A Axial module Features Modular assembly Robust design Suitable for standard and EMC housings Low wiring costs Technical characteristics Electrical data acc. to IEC 40 A 500 V 6 kv 3 61984 Rated current 40 A Rated voltage 500 V Rated impulse voltage 6 kv Pollution degree 3 Material (insert) polycarbonate Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984 Details Hinged frames see chapter 06 18

adapter for Han 40 A Axial module Identification Han C, Solder contact, contact resistance 3 mohm Part number male female 09 32 000 6295 Drawing adapter, in the Han 40 A Axial module 09 14 002 2603 09 14 002 2703 19

adapter for Han E Features Robust design Suitable for standard and EMC housings Low wiring costs Counter connector available with screw, crimp or cage clamp termination Technical characteristics Electrical data acc. to IEC 16 A 500 V 6 kv 3 61984 Rated current 16 A Rated voltage 500 V Rated impulse voltage 6 kv Pollution degree 3 Material (insert) polycarbonate Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984 Details Crimping tools see chapter 90 Han E crimp inserts see chapter 03 Hoods/housings see chapter 31 20

adapter for Han E Identification Han E, to connect the adapter, Double contact, contact resistance 3 Ohm Part number male female 09 33 000 6180 09 33 000 6280 Drawing adapter, in the Han E crimp insert 09 33 000 9996 09 33 000 9996 21

adapter for Han Q 4/2 Features Robust design Low wiring costs High density of contacts Suitable for Han-Compact hoods and housings Technical characteristics Electrical data acc. to IEC 30 A 400/690 V 6 kv 2 61984 Rated current 30 A Rated voltage conductor - 400 V ground Rated voltage conductor - conductor 690 V Rated impulse voltage 6 kv Pollution degree 2 Electrical data, signal 7.5 A 250 V 4 kv 2 Rated current 7.5 A Rated voltage 250 V Rated impulse voltage 4 kv Limiting temperatures -40 C... 125 C Flammability (hoods/housings) V 0 acc. to UL 94 Flammability (locking lever) acc. V 0 to UL 94 Protection class acc. to UL 50 NEMA type 4/4X/12 Degree of protection acc. to IEC IP65 / IP67 60529 Material (insert) LCP Material (hoods/housings) polycarbonate Colour (hoods/housings) RAL 9005 (black) Material (locking lever) polyamide Colour (locking lever) RAL 9005 (black) Material (seal) NBR Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984, Details Han Q inserts see chapter 13 Crimping tools see chapter 90 22

adapter for Han Q 4/2 Identification Part number male female Drawing Han D, to connect the adapter, Double contact, silver plated contacts, contact resistance 3 mohm 09 15 000 6191 09 15 000 6293 Han C, to connect the adapter, Double contact, contact resistance 3 mohm 09 32 000 6180 09 32 000 6280 adapter, for s up to 2.4 mm, in the Han Q 4/2 09 12 006 9901 09 12 006 9901 23

adapter for Han Q 4/2 Size Han-Compact Plastic hoods/housings for industrial applications double locking lever Identification Han-Compact, Bulkhead mounted housings, straight version Part number 09 12 008 0327 Drawing 24

adapter for Han Q 5/0 Features Robust design Suitable only for EMC housings size Han 3 A Additional robust and secure PE-connection between housing and Technical characteristics Electrical data acc. to IEC 10 A 230/400 V 4 kv 3 61984 Rated current 10 A Rated voltage conductor - 230 V ground Rated voltage conductor - conductor 400 V Rated impulse voltage 4 kv Pollution degree 3 Limiting temperatures -40 C... 125 C Flammability (locking lever) acc. V 0 to UL 94 Protection class acc. to UL 50 NEMA type 4/4X/12 Degree of protection acc. to IEC 60529 IP44 / IP67 is achieved with seal screw 09 20 000 9918 Material (insert) polycarbonate Material (hoods/housings) zinc die-cast Surface (hoods/housings) unpainted Material (locking lever) steel, zinc-plated Material (seal) NBR Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984 Details Han Q inserts see chapter 13 Crimping tools see chapter 90 25

adapter for Han Q 5/0 Identification Part number male female Drawing Han E, to connect the adapter, Solder contact, silver plated contacts, contact resistance 3 Ohm 09 33 000 6195 09 33 000 6295 Han Q, adapter, 5 pins, in the Han Q 5/0 09 12 000 9905 09 12 000 9905 Adapter PE contact panel 26

adapter for Han Q 5/0 Size 3 A Hoods/Housings for higher EMC requirements double locking lever Identification Han EMV, Bulkhead mounted housings Part number 09 62 003 0304 Drawing 27

adapter for Han Q 7/0 Features Robust design Suitable for standard and EMC housings High density of contacts Technical characteristics Electrical data acc. to IEC 7.5 A 250 V 4 kv 3 61984 Rated current 7.5 A Rated voltage 250 V Rated impulse voltage 4 kv Pollution degree 3 Limiting temperatures -40 C... 125 C Degree of protection acc. to IEC 60529 IP44 / IP67 is achieved with seal screw 09 20 000 9918 Material (insert) polycarbonate Material (hoods/housings) zinc die-cast Surface (hoods/housings) powder-coated Colour (hoods/housings) RAL 7037 (grey) Material (locking lever) steel, zinc-plated Material (seal) NBR Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984 Details Han Q inserts see chapter 13 Crimping tools see chapter 90 28

adapter for Han Q 7/0 Identification Part number male female Drawing Han D, to connect the adapter, Double contact, silver plated contacts, contact resistance 3 mohm 09 15 000 6190 09 15 000 6290 adapter, for s up to 2.4 mm, in the Han Q 7/0 09 12 000 9908 09 12 000 9908 29

adapter for Han Q 7/0 Size 3 A Metal hoods/housings for industrial applications double locking lever Identification Han A, Bulkhead mounted housings, straight Part number 09 20 003 0301 Drawing Panel cut out 22 x 22 mm 30

adapter for Han Q 8/0 Features Robust design Suitable for Han-Compact hoods and housings Low wiring costs High density of contacts Technical characteristics Electrical data acc. to IEC 16 A 230/400 V 4 kv 2 61984 Rated current 16 A Rated voltage conductor - 230 V ground Rated voltage conductor - conductor 400 V Rated impulse voltage 4 kv Pollution degree 2 Limiting temperatures -40 C... 125 C Flammability (hoods/housings) V 0 acc. to UL 94 Flammability (locking lever) acc. V 0 to UL 94 Protection class acc. to UL 50 NEMA type 4/4X/12 Degree of protection acc. to IEC IP65 / IP67 60529 Material (insert) LCP Material (hoods/housings) polycarbonate Colour (hoods/housings) RAL 9005 (black) Material (locking lever) polyamide Colour (locking lever) RAL 9005 (black) Material (seal) NBR Material (contact) copper alloy Specifications and approvals IEC 60664-1 IEC 61984, Details Han Q inserts see chapter 13 Crimping tools see chapter 90 31

adapter for Han Q 8/0 Identification Part number male female Drawing Han E, to connect the adapter, Double contact, contact resistance 3 Ohm 09 33 000 6180 09 33 000 6280 Han Q, adapter, for s up to 1.6 mm, in the Han Q 8/0 09 12 008 9901 09 12 008 9901 32

adapter for Han Q 8/0 Size Han-Compact Plastic hoods/housings for industrial applications double locking lever Identification Han-Compact, Bulkhead mounted housings, straight version Part number 09 12 008 0327 Drawing 33

adapter for Han Q 12/0 Features Robust design Suitable for standard and EMC housings High density of contacts Derating Current carrying capacity The current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature. Measuring and testing techniques acc. to IEC 60512-5-2 Technical characteristics Contacts 12/0 Electrical data acc. to IEC 7.5 A 250 V 4 kv 3 61984 Rated current 7.5 A Rated voltage 250 V Rated impulse voltage 4 kv Pollution degree 3 Insulation resistance 10 10 Ohm Limiting temperatures -40 C... 125 C Flammability (insert) acc. to V 0 UL 94 Mating cycles 500 Flammability (seal) acc. to V 0 UL 94 Material (insert) polycarbonate Colour (insert) RAL 7032 (light grey) Material (contact) copper alloy Operating current (A) Specifications and approvals IEC 60664-1 IEC 61984,, Details Crimping tools see chapter 90 Ambient temperature (C ) 1 Wire cross section 0.75 mm² 2 Wire cross section 1.5 mm² 3 Wire cross section 2.5 mm² 34

adapter for Han Q 12/0 Size 3 A Number of contacts 12/0+ 250 V 7.5 A Identification Han Q, Solder terminal, for adapter Part number male female 09 12 012 3002 09 12 012 3102 Drawing Please order contacts separately. Han D, to connect the adapter, Double contact, silver plated contacts, contact resistance 3 mohm 09 15 000 6191 09 15 000 6297 adapter, for s up to 2.4 mm 09 12 012 9901 09 12 012 9901 35

Application Secondary mating between industrial connector and printed circuit board. No higher force is applied on the soldering joint when mating the industrial connector due to an additional mating point. No wiring between printed circuit board and industrial connector necessary. This means no wiring faults no testing, no costs Connecting times are minimized. Easy handling is time and cost saving. The production of mechanical and electrical / electronically components can be completely separated. Possibility to reach a higher degree of automation in the production (e.g. wave soldering of the s). Han DD and Han Q 5/0 adapter Wilhelm Fette GmbH, Germany Han E adapter 1 ➀ adapter for Han E ➁ Han E connector in a bulkhead mounted housing ➂ Switch board panel ➃ Printed circuit board () 4 3 36 2