Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Similar documents
4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

Overview. Switch Features CHAPTER

Overview. Features CHAPTER

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

Product Overview. Features CHAPTER

Troubleshooting CHAPTER

This chapter describes the power management feature in the Catalyst enterprise LAN switches.

Product Overview. Switch Descriptions. Front Panel CHAPTER

Product Overview. Features CHAPTER

Chapter 7 Hardware Overview

Cisco Catalyst 4500 Series

Cisco Catalyst

Product Overview. Features. Send documentation comments to CHAPTER

ERX System Overview. The ERX System. This chapter provides information about the system.

Advanced security capabilities like ETA, MACSec-256 and TrustWorthy systems.

Software configuration guide

Cisco Catalyst 6500 Series Mixed Media Gigabit Ethernet Modules

Switched Uplink Modules

Product Overview. Cisco 7600 Series Routers. Supported Hardware CHAPTER

Maintaining the Cisco Catalyst 5500 Multiswitch Router

This section describes the software and hardware requirements for the module.

Cisco ASR 1001-X Router Overview

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

Cisco Etherswitch Service Modules

Configuring Interface Characteristics

1-Port Gigabit Ethernet Line Card Overview

Chassis-based Media Converters

Product Overview. Switch Models CHAPTER

Product Overview. Switch Models CHAPTER

Product Overview. Cisco ME 6524 Ethernet Switch (ME-C6524GS-8S) CHAPTER

Product Overview. Switch Model

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

Cisco MDS 9250i Multiservice Fabric Switch Overview. Introduction CHAPTER

C H A P T E R Figure 1-1 Modular Stacked Network System 1-1

New Products: Cisco Catalyst 2950 Series Intelligent Ethernet Switches

Summit Virtual Chassis Design and Installation Guide

Cisco Series Gigabit Ethernet Half-Height Line Card

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Installation Manual. Table of Contents

Best Connectivity. 5-Port 10/100Mbps Desktop Switch with 4-Port PoE

Configuring EtherChannels

Cisco Catalyst 4500 Series Line Cards

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

Ethernet Cards. 5.1 Card Overview CHAPTER

LAN design. Chapter 1

Product Overview. Send documentation comments to CHAPTER

Pass-Through Technology

GSW-2453 Gigabit Chassis switch. User Guide

Cisco EtherSwitch 4- and 9-Port High-Speed WAN Interface Cards Datasheet

Preface. Managed Media Converter Chassis System

One of the following problems exist: At least one power supply LED is red. At least one power supply is down. Fan trays are all operational.

MultiFlow Multilayer Switch Family

Installing the IPS 4345 and IPS 4360

Cisco RF Gateway 10 Supervisor Engine V-10GE

The operator has activated this LED to identify this chassis. This chassis is not being identified. Fabric modules are all operational.

Cajun P120 Version 3.1 Release Notes

Introduction to the Catalyst 3920

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

High Availability and Redundant Operation

Cajun P220FE Switch Software Release Notes

Chassis-based Media Converters

Product Overview. Switch Features Overview CHAPTER

Catalyst 2960-X and 2960-XR Switch Hardware Guide

Overview. About the Catalyst 2820 and Catalyst 1900 Switches CHAPTER

Chapter 6 Hardware Overview

Product Overview. Switch Model CHAPTER

Product Overview. Physical and Functional Description of Router CHAPTER1

Product Overview CHAPTER

Master Hub Ethernet Switch (MHES)

PEM Faults and Blower Failures

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER

H3C SecPath M9000-S NSQM2MPUD0 main processing unit

Product Overview. Introduction. Hardware Features CHAPTER

Troubleshooting Initial Startup Problems

Cisco Small Business Managed Switches

Installation Preparation

Save installation time and money with PoE

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

IBM Ethernet Switch J08E and IBM Ethernet Switch J16E

Installation. Package Contents CHAPTER

3Com Switch 4007 and Switch 4007R

CVH Slot Media Converter Chassis Quick Installation Guide

3Com Switch 4007 and Switch 4007R

Overview of QoS Support on Catalyst Platforms and Exploring QoS on the Catalyst 2900XL, 3500XL, and Catalyst 4000 CatOS Family of Switches

Cisco Catalyst 4500 Series Chassis

Brochure. ION Multi-Service Integration Platform. Integrate. Optimize. Navigate. Transition Networks Brochure.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Troubleshooting the Installation

New Cisco Catalyst 4948E-F Ethernet Switch for High-Performance Data Center Access

Catalyst 4000/5000 Product Update

Configuring Interfaces

Cisco Catalyst 4500 Series integrates resiliency for advanced control of converged networks. Overview

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP Managed Switch

Installing Supervisor Engines

Media Converters & Chassis

Cisco 2-, 5-, 8-, and 10-Port Gigabit Ethernet Shared Port Adapters, Version 2

Cisco Series Performance Routing Engine 4

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Product features. Applications

Transcription:

CHAPTER This chapter provides an overview of the features and components of the Catalyst 4500 series switches. The Catalyst 4500 series switches are the Catalyst 4503 switch, the Catalyst 4506 switch, and the Catalyst 4507R switch. The information is presented in these major sections: Switch Features, page - Supervisor Engines, page -3 Switch Features The following sections describe the features of the Catalyst 4500 series switches: Catalyst 4503 Switch Features, page - Catalyst 4506 Switch Features, page -5 Catalyst 4507R Switch Features, page -9 Catalyst 4503 Switch Features The Catalyst 4503 switch (see Figure -) is a three-slot switch designed for high-performance, high-density wiring closet applications. 78-4409-03 B0 -

3 3 3 3 0/00 CONSOLE MGT LINK Switch Features Chapter Figure - Catalyst 4503 Switch (Front View) Power supplies Supervisor engine (slot ) Switching modules (slots 2 and 3) 4506 4503 WS-X455 SUPERVISOR ENGINE IV UPLINK UPLINK 2 LINE ACTIVE LINE ACTIVE ACTIVE UTILIZATION % 00% EJECT FLASH RESET Fan assembly 77980 The Catalyst 4503 switch supports the Supervisor Engine III and IV. The supervisor engine has two Gigabit Ethernet ports and a 64-Gbps, nonblocking, full-duplex, switching fabric that provides connections between the supervisor engine and the switching modules. The Gigabit Ethernet ports can be configured with any combination of shortwave SX, LX/LH, and ZX Gigabit Interface Converters (GBICs). For a description of GBICs, refer to the Catalyst 4000 Family Module Installation Guide. Slot is reserved for the supervisor engine only, which provides switching, local and remote management, and switch-status monitoring. Slots 2 and 3 are available for switching modules. Table - describes the features of the Catalyst 4503 switch. -2 78-4409-03 B0

Chapter Switch Features Table - Features of the Catalyst 4503 Switch Feature Description Ethernet speeds Ethernet (0BASE-T) interface to workstations and repeaters Fast Ethernet (00BASE-T) interface to workstations, servers, switches, and routers Autonegotiation of link speed on each 0/00 port allows migration to 00BASE-T from a 0BASE-T installed base. Gigabit Ethernet (000BASE-T and 000BASE-X) interfaces for backbone interconnection of high-performance switches and routers Standard equipment Three-slot modular chassis with one slot reserved for a supervisor engine and two slots for switching modules Standard management and support Embedded management One hot-swappable fan assembly Supports Layer 2 forwarding with an aggregate forwarding rate of 8 Mpps Supports 32,768 MAC addresses per system Supports up to 4,096 VLANs with IEEE 802.Q VLAN tagging on all ports and VTP Supports port aggregation using PAgP 2 for 00-Mbps and 000-Mbps EtherChannel Full SNMP implementation, including entity-mib, all relevant standard MIBs, and all relevant Cisco MIBs The first four RMON groups (Ethernet statistics, Alarms, Events, and History) are on a per-port basis without an optional RMON processing module Provides SPAN 3, which allows you to redirect traffic from any port or VLAN to a SPAN destination port Performance management information 78-4409-03 B0-3

Switch Features Chapter Table - Features of the Catalyst 4503 Switch (continued) Feature Description Power supplies Supports a 000 W, 300 W, or 2800 W AC-input power supply or a 400 W DC-input power supply 4 Optional redundant power supply Supervisor engine Supports the Supervisor Engine II, III, and IV Holds the ASIC-based forwarding engine (data path) and the management processor and software (control path) Features interface monitoring, environmental status, and SNMP and console/telnet interface Packets are not forwarded while the module is removed; a system reboot occurs when a supervisor engine is reinserted. Features a 64-Gbps full-duplex Gigabit Ethernet switching engine The Catalyst 4503 switch has a port capacity of 28 Gbps. Supported switching modules Includes two Gigabit Ethernet (000BASE-X) interfaces for backbone interconnection of high-performance switches and routers Supervisor Engines III and IV support 48 Mpps 5 Layer 2, 3, and 4 forwarding 24-port 00BASE-FX Fast Ethernet switching module (WS-X424-FX-MT) 48-port 00BASE-FX Fast Ethernet switching module (WS-X448-FX-MT) 48-port 0/00-Mbps Fast Ethernet switching module (WS-X448-RJ) 48-port 0/00-Mbps Fast Ethernet switching module (WS-X448-RJ2) 48-port Inline Power 0/00BASE-TX switching module (WS-X448-RJ45V) 32-port 0/00-Mbps Fast Ethernet plus 2-port Gigabit Ethernet switching module (WS-X4232-GB-RJ) -4 78-4409-03 B0

Chapter Switch Features Table - Features of the Catalyst 4503 Switch (continued) Feature Supported switching modules (continued) Description 32-port 0/00-Mbps Fast Ethernet switching module with modular uplink support (WS-X4232-RJ-XX) 4-port 00BASE-FX MT-RJ uplink module (WS-X4504-FX-MT) (optional) 6-port 000BASE-X Gigabit Ethernet switching module (WS-X4306-GB) 2-port 000BASE-TX plus 2-port 000BASE-X Gigabit Ethernet switching module (WS-X442-2GB-T) 8-port Gigabit Ethernet switching module (WS-X448-GB) 24-port 0/00/000BASE-T Gigabit Ethernet switching module (WS-X4424-GB-RJ45) 48-port Gigabit Ethernet switching module (WS-X4448-GB-LX) 48-port 0/00/000BASE-TX Gigabit Ethernet switching module (WS-X4448-GB-RJ45). VTP = VLAN Trunking Protocol 2. PAgP = Port Aggregation Protocol 3. SPAN = switched port analyzer 4. You will need to configure the 400 W DC input current as appropriate for the model of switch. Refer to Appendix A, Specifications. 5. Mpps = Million packets per second Catalyst 4506 Switch Features The Catalyst 4506 switch (see Figure -2) is a six-slot switch designed for high-performance, high-density wiring closet applications. 78-4409-03 B0-5

ACTIVE 3 3 3 UTILIZATION % 00% 3 3 3 CONSOLE 0/00 MGT LINK EJECT FLASH Switch Features Chapter Figure -2 Catalyst 4506 Switch (Front View) Power supplies Supervisor engine (slot ) 4506 WS-X455 SUPERVISOR ENGINE IV UPLINK UPLINK 2 LINE ACTIVE LINE ACTIVE RESET Switching modules (slots 2 through 6) Fan assembly 7750 The Catalyst 4506 switch supports the Supervisor Engine III and IV. The supervisor engine has two Gigabit Ethernet ports and a 64-Gbps, nonblocking, full-duplex, switching fabric that provides connections between the supervisor engine and the switching modules. The Gigabit Ethernet ports can be configured with any combination of shortwave SX, LX/LH, and ZX GBICs. For a description of GBICs, refer to the Catalyst 4000 Family Module Installation Guide. Slot is reserved for the supervisor engine only, which provides switching, local and remote management, and switch-status monitoring. Slots 2 through 6 are available for switching modules. Table -2 describes the features of the Catalyst 4506 switch. -6 78-4409-03 B0

Chapter Switch Features Table -2 Features of the Catalyst 4506 Switch Feature Description Ethernet speeds Ethernet (0BASE-T) interface to workstations and repeaters Fast Ethernet (00BASE-T) interface to workstations, servers, switches, and routers Autonegotiation of link speed on each 0/00 port allows migration to 00BASE-T from a 0BASE-T installed base. Gigabit Ethernet (000BASE-T and 000BASE-X) interfaces for backbone interconnection of high-performance switches and routers Standard equipment Six-slot modular chassis with one slot reserved for a supervisor engine and five slots for switching modules Standard management and support One hot-swappable fan assembly Supports Layer 2 forwarding with an aggregate forwarding rate of 48 Mpps Supports 32,768 MAC addresses per system Supports up to 4,096 VLANs with IEEE 802.Q VLAN tagging on all ports and support for VTP Supports port aggregation using PAgP 2 for 00-Mbps and 000-Mbps EtherChannel Embedded management Full SNMP implementation, including entity-mib, all relevant standard MIBs, and all relevant Cisco MIBs The first four RMON groups (Ethernet statistics, Alarms, Events, and History) are on a per-port basis without optional RMON processing module Provides SPAN 3, which allows you to redirect traffic from any port or VLAN to a SPAN destination port Performance management information 78-4409-03 B0-7

Switch Features Chapter Table -2 Features of the Catalyst 4506 Switch (continued) Feature Description Power supplies Supports a 000 W, 300 W, or 2800 W AC-input power supply or a 400 W DC-input power supply 4 Optional redundant power supply Supervisor engine Supports the Supervisor Engine II, III, and IV Holds the ASIC-based forwarding engine (data path) and the management processor and software (control path) Features interface monitoring, environmental status, and SNMP and console/telnet interface Packets are not forwarded while the module is removed; a system reboot occurs when a supervisor engine is reinserted. Supported switching modules Features a 64-Gbps full-duplex Gigabit Ethernet switching engine Includes two Gigabit Ethernet (000BASE-X) interfaces for backbone interconnection of high-performance switches and routers Supervisor Engines III and IV support 48 Mpps Layer 2, 3, and 4 forwarding 24-port 00BASE-FX Fast Ethernet switching module (WS-X424-FX-MT) 48-port 00BASE-FX Fast Ethernet switching module (WS-X448-FX-MT) 48-port 0/00-Mbps Fast Ethernet switching module (WS-X448-RJ) 48-port 0/00-Mbps Fast Ethernet switching module (WS-X448-RJ2) 48-port Inline Power 0/00BASE-TX switching module (WS-X448-RJ45V) 32-port 0/00-Mbps Fast Ethernet plus 2-port Gigabit Ethernet switching module (WS-X4232-GB-RJ) -8 78-4409-03 B0

Chapter Switch Features Table -2 Features of the Catalyst 4506 Switch (continued) Feature Supported switching modules (continued) Description 32-port 0/00-Mbps Fast Ethernet switching module with modular uplink support (WS-X4232-RJ-XX) 4-port 00BASE-FX MT-RJ uplink module (WS-X4504-FX-MT) (optional) 6-port 000BASE-X Gigabit Ethernet switching module (WS-X4306-GB) 2-port 000BASE-TX plus 2-port 000BASE-X Gigabit Ethernet switching module (WS-X442-2GB-T) 8-port Gigabit Ethernet switching module (WS-X448-GB) 24-port 0/00/000BASE-T Gigabit Ethernet switching module (WS-X4424-GB-RJ45) 48-port Gigabit Ethernet switching module (WS-X4448-GB-LX) 48-port 0/00/000BASE-TX Gigabit Ethernet switching module (WS-X4448-GB-RJ45). VTP = VLAN Trunking Protocol 2. PAgP = Port Aggregation Protocol 3. SPAN = switched port analyzer 4. You will need to configure the 400 W DC input current as appropriate for the model of switch. Refer to Appendix A, Specifications. Catalyst 4507R Switch Features The Catalyst 4507R switch (see Figure -3) is a seven-slot switch designed for high-performance, high-density wiring closet applications. 78-4409-03 B0-9

WS-X4448-GB-RJ45 2 3 4 5 6 7 8 2 9 3 0 4 5 2 3 4 5 6 7 8 9 0 2 7 2 6 3 7 4 8 5 9 6 0 2 3 7 4 8 5 9 6 0/00BASE-TX ETHERNET 0/00BASE-TX ETHERNET 20 2 22 23 7 24 8 25 9 26 20 27 2 28 22 29 23 30 24 3 25 32 26 27 28 29 MULTI-SPEED GIGABIT ETHERNET 33 30 34 3 35 32 36 37 38 39 33 40 34 4 35 42 36 43 37 44 38 45 39 46 40 47 4 48 42 43 44 45 46 47 48 Switch Features Chapter Figure -3 Catalyst 4507R Switch (Front View) Power supplies Supervisor engine (slot ) Redundant supervisor engine (slot 2) WS-X442-2GB-TX UPLINK UPLINK UPLINK UPLINK CONSOLE CONSOLE 0/00 BASE-TX 0/00 BASE-TX Switching modules (slots 3 through 7) WS-X442-2GB-TX WS-X442-2GB-TX 2 3 4 5 6 7 8 9 0 2 7 2 3 4 5 6 7 8 9 0 2 7 WS-X4448-GB-RJ45 MULTI-SPEED GIGABIT ETHERNET SWITCHING MODULE 680 SWITCHING MODULE The Catalyst 4507R switch supports the Supervisor Engine IV. The supervisor engine has two Gigabit Ethernet ports and a 64-Gbps, nonblocking, full-duplex, switching fabric that provides connections between the supervisor engine and the switching modules. The Gigabit Ethernet ports can be configured with any combination of shortwave SX, LX/LH, and ZX GBICs. For a description of GBICs, refer to the Catalyst 4000 Family Module Installation Guide. Slot is reserved for the supervisor engine only, which provides switching, local and remote management, and switch-status monitoring. Slot 2 is reserved for a redundant supervisor engine only. Slots 3 through 7 are available for switching modules. -0 78-4409-03 B0

Chapter Switch Features Table -3 Table -3 describes the features of the Catalyst 4507R switch. Features of the Catalyst 4507R Switch Feature Description Ethernet speeds Ethernet (0BASE-T) interface to workstations and repeaters Fast Ethernet (00BASE-T) interface to workstations, servers, switches, and routers Autonegotiation of link speed on each 0/00 port allows migration to 00BASE-T from a 0BASE-T installed base. Gigabit Ethernet (000BASE-T and 000BASE-X) interfaces for backbone interconnection of high-performance switches and routers Standard equipment Seven-slot modular chassis with one slot reserved for a supervisor engine, one slot reserved for a redundant supervisor engine, and five slots for switching modules Standard management and support Embedded management Two AC-input power supplies One hot-swappable fan assembly Supports Layer 2 forwarding with an aggregate forwarding rate of 48 Mpps Supports 32,768 MAC addresses per system Supports up to 4,096 VLANs with IEEE 802.Q VLAN tagging on all ports and support for VTP Supports port aggregation using PAgP 2 for 00-Mbps and 000-Mbps EtherChannel Full SNMP implementation, including entity-mib, all relevant standard MIBs, and all relevant Cisco MIBs The first four RMON groups (Ethernet statistics, Alarms, Events, and History) on a per-port basis without an optional RMON processing module Provides SPAN 3, which allows you to redirect traffic from any port or VLAN to a SPAN destination port Performance management information 78-4409-03 B0 -

Switch Features Chapter Table -3 Features of the Catalyst 4507R Switch (continued) Feature Description Power supplies Can support a 000 W, 300 W, or 2800 W AC-input power supply or a 400 W DC-input power supply 4 Optional redundant power supply Supervisor engine Features interface monitoring, environmental status, and SNMP and console/telnet interface Packets are not forwarded while the module is removed; a system reboot occurs when a supervisor engine is reinserted. Supported switching modules Features a 64-Gbps full-duplex Gigabit Ethernet switching engine Includes two Gigabit Ethernet (000BASE-X) interfaces for backbone interconnection of high-performance switches and routers Supports 48 Mpps Layer 2, 3, and 4 forwarding 32-port 0/00-Mbps Fast Ethernet switching module with modular uplink support (WS-X4232-RJ-XX) 4-port 00BASE-FX MT-RJ uplink module (WS-X4504-FX-MT) (optional) 24-port 00BASE-FX Fast Ethernet switching module (WS-X424-FX-MT) 48-port 00BASE-FX Fast Ethernet switching module (WS-X448-FX-MT) 48-port 0/00-Mbps Fast Ethernet switching module (WS-X448-RJ) 48-port 0/00-Mbps Fast Ethernet switching module (WS-X448-RJ2) 48-port Inline Power 0/00BASE-TX switching module (WS-X448-RJ45V) -2 78-4409-03 B0

Chapter Supervisor Engines Table -3 Features of the Catalyst 4507R Switch (continued) Feature Supported switching modules (continued) Description 32-port 0/00-Mbps Fast Ethernet plus 2-port Gigabit Ethernet switching module (WS-X4232-GB-RJ) 6-port 000BASE-X Gigabit Ethernet switching module (WS-X4306-GB) 2-port 000BASE-TX plus 2-port 000BASE-X Gigabit Ethernet switching module (WS-X442-2GB-T) 8-port Gigabit Ethernet switching module (WS-X448-GB) 24-port 0/00/000BASE-T Gigabit Ethernet switching module (WS-X4424-GB-RJ45) 48-port Gigabit Ethernet switching module (WS-X4448-GB-LX) 48-port 0/00/000BASE-TX Gigabit Ethernet switching module (WS-X4448-GB-RJ45). VTP = VLAN Trunking Protocol 2. PAgP = Port Aggregation Protocol 3. SPAN = switched port analyzer 4. You will need to configure the 400 W DC input current as appropriate for the model of switch. Refer to Appendix A, Specifications. Supervisor Engines The following supervisor engines are available for the Catalyst 4500 series switches: Supervisor Engine II (WS-X403) (Figure -4) Supervisor Engine III (WS-X404) (Figure -5) Supervisor Engine IV (WS-X455) (Figure -6) The Catalyst 4500 series supervisor engines have the following features: Data path and control for all network interfaces Management functions: Interface monitoring Environmental status 78-4409-03 B0-3

0/00 Supervisor Engines Chapter SNMP and console/telnet interface Hot-swappable Packets are not forwarded while the module is removed. A system reboot occurs when a supervisor engine is reinserted. To install the supervisor engine, refer to the procedure in the Catalyst 4000 Family Module Installation Guide. Figure -4 Supervisor Engine II (WS-X403) LED Reset button UPLINK UPLINK 2 UPLINKS ENABLED Gigabit uplink ports % 00% Switch load indicators CONSOLE BASE-TX RESET Console port (RJ-45) Ethernet management port 78478-4 78-4409-03 B0

SUPERVISOR III ENGINE ACTIVE UTILIZATION UTILIZATION CONSOLE 0/00 MGT 0/00 Chapter Supervisor Engines Figure -5 Supervisor Engine III (WS-X404) LED Reset button WS-X404 UPLINK UPLINK 2 LINK ACTIVE LINK ACTIVE Gigabit uplink ports % 00% EJECT FLASH RESET 6826 Switch load indicators Compact Flash port Console port Management port Figure -6 Supervisor Engine IV (WS-X455) LED Reset button WS-X455 SUPERVISOR ENGINE IV UPLINK UPLINK 2 LINE ACTIVE LINE ACTIVE CONSOLE MGT Gigabit uplink ports % 00% Switch load indicators LINK EJECT Console port FLASH RESET Compact Flash port Ethernet management port 77509 For information about the connectors, LEDs, and switches located on the front panel of the supervisor engine, see these sections: LEDs, page -6 Gigabit Ethernet Uplink Ports, page -6 0/00BASE-T Port, page -7 Console Port, page -7 78-4409-03 B0-5

Supervisor Engines Chapter Reset Button, page -7 Flash Port, page -8 LEDs Table -4 describes the supervisor engine LEDs. Table -4 Supervisor Engine LEDs LED Color/State Description Indicates the results of a series of self-tests: Green All diagnostic tests passed. Red A test failed. Orange System boot or diagnostic test is in progress. Off Module is disabled. UTILIZATION Green 00% If the switch is operational, this display indicates the current traffic load over the backplane (as an approximate percentage). LINK Indicates the status of the 0/00BASE-T port or uplink ports: Green The link is operational. Orange The link is disabled by user. Flashing orange The power-on self-test indicates a faulty port. Off No signal is detected or there is a link configuration failure. ACTIVE Indicates whether the uplink port is active or not: Green The port is active. Off The port is not active. Gigabit Ethernet Uplink Ports The Gigabit Ethernet uplink ports operate in full-duplex mode only. GBICs have SC connectors to interface with multimode fiber (MMF) and single-mode fiber (SMF) cable. For more information about GBICs, refer to the Catalyst 4000 Family Module Installation Guide. -6 78-4409-03 B0

Chapter Supervisor Engines 0/00BASE-T Port The 0/00BASE-T port supports emergency image recovery. The 0/00BASE-T port supports image downloads from the ROMMON. You can use this feature when the onboard flash does not contain any IOS images, usually after all images have accidentally been deleted from onboard Flash. Console Port The console port has an EIA/TIA-232 RJ-45 connector. The console port allows you to perform the following functions: Configure the switch from the CLI Monitor network statistics and errors Configure SNMP agent parameters EIA/TIA-232 was known as recommended standard RS-232 before its acceptance as a standard by the Electronic Industries Alliance (EIA) and Telecommunications Industry Association (TIA). Reset Button The Reset button is used to restart the switch. Use a paper clip or other small, pointed object to press the Reset button. 78-4409-03 B0-7

Fan Assembly Chapter Flash Port The Flash port accepts a Type Compact Flash card. You can use it for file transfer tasks such as loading a new software image. The Flash card is optional and can be obtained from third-party suppliers. For more information, refer to Using the Compact Flash on the Catalyst 4000 Family Supervisor Engine III and IV at the following URL: http://www.cisco.com/univercd/cc/td/doc/product/lan/cat4000/inst_nts/ ol_2788.htm Fan Assembly For complete environmental specifications, including airflow requirements, see Appendix A, Specifications. The system fan assembly provides cooling air for the internal chassis components. The fan assembly is a tray of fans that you can insert and remove from the chassis while the system is on line. The Catalyst 4503 fan assembly has two fans, the Catalyst 4506 fan assembly has four fans, and the Catalyst 4507R fan assembly has six fans. The fans draw in fresh air from one side and exhaust air on the other side. Catalyst 4503 airflow is shown in Figure -7. Catalyst 4506 airflow is shown in Figure -8. Catalyst 4507R airflow is shown in Figure -9. Caution You must install module filler plates on unused switching module slots to ensure proper airflow. -8 78-4409-03 B0

UPLINK UPLINK 2 LINE ACTIVE LINE ACTIVE ACTIVE WS-X455 SUPERVISOR ENGINE IV UPLINK UPLINK 2 LINE ACTIVE LINE ACTIVE ACTIVE 3 3 3 3 3 3 3 % 00% UTILIZATION 0/00 CONSOLE MGT % 00% 3 3 3 LINK CONSOLE EJECT 0/00 MGT FLASH LINK EJECT FLASH Chapter Fan Assembly Figure -7 Catalyst 4503 Airflow 4506 WS-X455 SUPERVISOR ENGINE IV 4503 UTILIZATION RESET 7798 Fan assembly Figure -8 Catalyst 4506 Airflow 4506 RESET Fan assembly 775 78-4409-03 B0-9

WS-X442-2GB-TX WS-X4448-GB-RJ45 WS-X442-2GB-TX WS-X442-2GB-TX 2 3 4 5 6 7 8 2 9 3 0 4 5 2 3 4 5 6 7 8 9 0 2 7 2 3 4 5 6 7 8 9 0 2 7 2 3 4 5 6 7 8 9 0 2 7 2 6 3 7 4 8 5 9 6 0 2 3 7 4 8 5 9 6 0/00BASE-TX ETHERNET 0/00BASE-TX ETHERNET 20 2 22 23 7 24 8 25 9 26 20 27 2 28 22 29 23 30 24 3 25 32 26 27 28 29 33 30 34 3 35 32 36 37 38 39 33 40 34 CONSOLE 4 35 42 36 0/00 BASE-TX CONSOLE 0/00 BASE-TX 43 37 44 38 45 39 46 40 47 4 48 42 43 44 45 46 47 48 Power Supplies Chapter Figure -9 Catalyst 4507R Airflow UPLINK UPLINK UPLINK UPLINK WS-X4448-GB-RJ45 Fan assembly MULTI-SPEED GIGABIT ETHERNET SWITCHING MODULE MULTI-SPEED GIGABIT ETHERNET SWITCHING MODULE 68 Power Supplies A Catalyst 4500 series switch can use a 000 W, 300 W, or 2800 W AC-input power supply (see Figure -0) or a 400 W DC-input power supply with integrated PEM (see Figure -). The AC-input power supply has a power cord that connects each power supply to the site power source. The DC-input power supply is equipped with a compression-style input terminal block that is directly connected to the site power wiring. Each power supply has an ON/OFF switch that supplies power to the switch. For information on removing and replacing power supplies, see the Removing and Replacing the Power Supply section on page 4-2. -20 78-4409-03 B0

Chapter Power Supplies Figure -0 AC-Input Power Supply Captive screws Power switch AC receptacle 7936 Figure - 400 W DC-Input Power Supply Captive screws 682 The input terminals on the 400 W DC-input power supply are sized for cables that are appropriate for the maximum input that the supply will handle. You can use smaller cables if they are appropriate for the current flow in a specific environment. 78-4409-03 B0-2

Power Supplies Chapter Catalyst 4500 series switches support one power supply and an optional redundant power supply. Each power supply has an individual power cord and status LEDs. Systems with redundant power supplies will share the load, with each unit providing approximately one-half of the total load. For information about configuring your switch for redundant and combined modes, refer to the software configuration guide for your switch. When power is removed from one power supply on a Catalyst 4500 series switch that has two power supplies, the redundant power feature causes the second power supply to produce full power. To replace a power supply, see the Removing and Replacing the Power Supply section on page 4-2. Power Supply LEDs Table -5 describes the power supply LEDs. Table -5 Power Supply LEDs LED Color/State Description INPUT OK Indicates whether the input voltage is within the required range: Green Input voltage is within the required range. Flashing Input voltage is present, but is below required range. Off Input voltage is below the required range or the power supply is off. OUTPUT FAIL Indicates whether the output voltage is within the specified range: Red Output voltage is not within the specified range. Off Output voltage is within the specified range. FAN OK Indicates the status of the power supply fans: Green The fans are operational. Off The fans are not operational. -22 78-4409-03 B0

Chapter Power Supplies Table -5 Power Supply LEDs (continued) LED Color/State Description In-line PWR (for 400 W DC-input power supplies only) In-line PWR (AC-input) Green Off Indicates the status of the in-line power connection: -48 V passthru output voltage is enabled and is greater than -39V and less then -60 V. Indicates any of the following: Passthru breakers are not enabled DC input is less than -40.5 V One or more -48V outputs is less then -39 V. Amber Passthru breakers are enabled and input voltage exceeds -60 V. Power Supply Fan Each power supply has a built-in fan. Air enters the front of the power supply (power-input end) and exits through the back. An air dam keeps the airflow separate from the rest of the chassis, which is cooled by the system fan assembly. Load-Sharing Feature When you install and turn on a second power supply on a Catalyst 4500 series switch, it provides approximately one-half of the required power to the system. If one power supply fails, the other power supply immediately assumes full power to maintain uninterrupted system operation. Load sharing works only when both power supplies in the chassis are the same type. When you install a redundant power supply, load sharing and fault tolerance are enabled automatically; no additional software configuration is required. 78-4409-03 B0-23

Power Supplies Chapter Environmental Monitoring Feature With the environmental monitoring and reporting feature, you can keep your system running by resolving adverse environmental conditions before loss of operation. The power supply monitors its own internal temperature and voltages. In the event of excessive internal temperature, the power supply shuts down to prevent damage. When the power supply returns to a safe operating temperature, it restarts. If the power supply output voltage is not within the specified range, the LED labeled OUTPUT FAIL will light. An instance of substantial input overvoltage can shut down the power supply. An instance of substantial input overvoltage (greater than -75 VDC continuous) can damage the power supply input circuitry and can cause it to shut down permanently. The main power switch has an input range of -40.5 to -72 VDC, while the -48 V voice power switch operates over a range of -40.5 to -56 VDC. The voice power will either fail to start or will shut down if exposed to greater than -56 VDC input. Voice power will recover after you recycle input power within the proper voltage range. If the voice power shuts down due to input overvoltage (greater than -56 VDC), the main convertor section will not shut down. The supervisor engine monitors the status of each power supply and provides a status report through the switch software. For more details on how the supervisor engine monitors the power supplies, refer to the Catalyst 4000 Family Module Installation Guide. -24 78-4409-03 B0