For further information, please contact Geoff Higgins at or by at

Similar documents
BC Hydro writes in compliance with Commission Order No. G-67-10, to provide its Report.

BC Hydro writes in compliance with Commission Order No. G-67-10, Directive 6, to provide its Report.

March 11, Ms. Erica M. Hamilton Commission Secretary British Columbia Utilities Commission Sixth Floor 900 Howe Street Vancouver, BC V6Z 2N3

B-1-1. Janet L. Fraser Director, Regulatory Affairs Phone: Fax:

bcuc British Columbia Utilities Commission

SUBJECT: PRESTO operating agreement renewal update. Committee of the Whole. Transit Department. Recommendation: Purpose: Page 1 of Report TR-01-17

Figure 1: Summary Status of Actions Recommended in June 2016 Committee Report. Status of Actions Recommended # of Actions Recommended

BEFORE THE PENNSYLVANIA PUBLIC UTILITY COMMISSION PETITION OF PECO ENERGY COMPANY FOR APPROVAL OF ITS SMART METER UNIVERSAL DEPLOYMENT PLAN

12 Approval of a New PRESTO Agreement Between York Region and Metrolinx

Re: FortisBC Inc. Customer Complaint Melody Farmer Boswell Power Surge and Incident Report

BSES Smart Grid Road Map

The North American Electric Reliability Corporation ( NERC ) hereby submits

EB CDM Exemption Hydro One Networks' Undertaking Responses ONLY HYDRO ONE UNDERTAKINGS Undertaking Description Filed Date Note

XXXX. Bear Creek Hydro Generation Project. Interconnection Facilities Study

Contractor Alliancing Sean Mooney Programme Manager

SHARED SERVICES - INFORMATION TECHNOLOGY

Minutes - Standing Policy Committee on Finance - April 9, 2015 REPORTS

Budget Review Process (BRP) Preliminary List of Business Initiatives. Stakeholder Meeting April 10, 2017

Project Features. Power Sector Improvement Project (RRP KGZ ) $ 44.8 million (62.7% grant % loan) ADF amount:

Cellnex Telecom Q3 revenues grow by 42% to 453 million

February 27, Dear Ms. England:

Cereal Hudson. Tariffs. Anthony S. Campagiorni, Esq. Vice President, Regulatory & Governmental Affairs. Requested Revenue Increases


General Subscriber Service Tariff: A Original Page Original Page

ENMAX Power Corporation

January 30, Docket Nos. ER and ER Interconnection Queue Quarterly Progress Report, Q4 2014

APPLICATION No. To the ALBERTA ENERGY AND UTILITIES BOARD RE:

AGENDA Regular Commission Meeting Port of Portland Headquarters 7200 N.E. Airport Way, 8 th Floor August 13, :30 a.m.

Studies Overview and Data Requirements. Robert Pan

Proposal for an in-period capex adjustment to account for new market reform obligations

Information Technology Services. Informational Report for the Board of Trustees October 11, 2017 Prepared effective August 31, 2017

Billing and Collection Agent Report For period ending January 31, To FCC Contract Oversight Sub-Committee. February 11, 2019

WORKPAPERS TO PREPARED DIRECT TESTIMONY OF DAVID BUCZKOWSKI ON BEHALF OF SOUTHERN CALIFORNIA GAS COMPANY BEFORE THE PUBLIC UTILITIES

Agenda Item No. AGENDA ITEM BRIEFING

Distributor Thoughts on Smart Grid

Alberta Electric System Operator Secord 2005S Substation Needs Identification Document

CLIMATE BONDS STANDARD VERIFICATION LETTER

Funding California Investor Owned Utilities Smart Grid Technologies & Deployments

ATCO Electric Ltd. Dawes Substation and Telecommunications Tower Project Facility Application

Evaluation of Business Cases for Smart Grid Solutions Kenny Mercado, Senior VP Electric Operations

EU DONOR FUNDED SMART GRID PROGRAMME

VP and Chief Technology Officer

Pilot Study on Big Data: Philippines. World Telecommunications/ICT Indicators Symposium (WTIS) November 2017 Hammamet, Tunisia

Regulatory Aspects of Smart Metering: US Practice

UNITED STATES SECURITIES AND EXCHANGE COMMISSION WASHINGTON, DC FORM 8-K

Our ambition is to upgrade 85% of Kiwis on our network onto Better Broadband.

Physical Security Reliability Standard Implementation

APPENDIX D SUMMARY OF FEDERAL AND PROVINCIAL GOVERNMENT FUNDING FOR BROADBAND ACCESS

Guideline for the Connection of Micro Embedded Generators to the TasNetworks Distribution Network

Duke Energy s Utility of the Future Project: Developing A Smart Grid Regulatory Strategy Across Multi-State Jurisdictions

Electrification - Infrastructure Construction activities in Segment 2:

Stakeholder Engagement Summary Report

ENMAX Generation Portfolio Inc.

Neutral Host Reimbursable Capital Project

Public Service Company of New Mexico. Public Transmission Planning Meeting March 2, 2017 Albuquerque, NM

Clean Power Call BC Transmission Corporation & BC Hydro Joint Information Session July 8, 2008

Lou Di Gironimo, General Manager Toronto Water, City of Toronto Toronto, Ontario, Canada

NORTH CAROLINA NC MRITE. Nominating Category: Enterprise IT Management Initiatives

Council, 26 March Information Technology Report. Executive summary and recommendations. Introduction

Ministry of Energy, Mines and Petroleum Resources. Guide to Acquiring Crown Petroleum and Natural Gas Tenures

NATIONAL PROGRAMME Chapter 15 Telecommunication and Post. Telecommunication and Post

Integrated Resource Planning April 20, 2010

Public Private Partnerships for sustainable and smart cities. Milano, 4 July 2017

Southern California Edison. Leading the Way in Electricity TM

Reston Town Center North Development. Community Update

February 18, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, DC 20426

Filing Date: Effective Date: Issued pursuant to Telecom Regulatory Policy CRTC ,

Southern Company Smart Grid

Financial Information

Smart Distribution Technology

Discussion Guide. Benvoulin Substation Project.

Symantec's Fiscal Second Quarter Supplemental Information

BC Hydro s Voltage and VAR Optimization Program IEEE PES JTCM VVC TF - 13 Jan 2010

What You Should Know About Communication Systems: Business Strategies and Options

Governing Body 313th Session, Geneva, March 2012

ORDER NO * * * * * * * * On April 21, 2017, Baltimore Gas and Electric ( BGE ) requested that the

Verizon Perspectives on Smart Infrastructure. Anthony J. (Tony) DiMaso Advanced Energy Conference November 19, 2009

Consultation on: Queue Management. Consultation Period. Opens: 16 th February 2016

Connecticut Department of Department of Administrative Services and the Broadband Technology Opportunity Program (BTOP) 8/20/2012 1

Council, 8 February 2017 Information Technology Report Executive summary and recommendations

LIST OF EFFECTIVE SHEETS. Sheets listed below are effective as of the date shown on each sheet.

Prepared Testimony of. Bohdan R. Pankiw. Chief Counsel Pennsylvania Public Utility Commission. before the

advantage net working

NATIONAL INFRASTRUCTURE COMMISSION CORPORATE PLAN TO

Memorandum APPENDIX 2. April 3, Audit Committee

IMO MEASURES TO ENHANCE MARITIME SECURITY. Outcome of the 2002 SOLAS conference. Information on the current work of the ILO

CALIFORNIA INDEPENDENT SYSTEM OPERATOR CORPORATION FERC ELECTRIC TARIFF ORIGINAL VOLUME NO. III Original Sheet No. 977 METERING PROTOCOL

System Impact Study for Power Supply 400 MW Import on the EAL BCHA Path

STATE OF ILLINOIS ILLINOIS COMMERCE COMMISSION ORDER

Decision D ATCO Electric Ltd. Crystal Lake 722S Substation Telecommunications Tower Replacement

CITY COUNCIL AGENDA REPORT

CIP Cyber Security Configuration Change Management and Vulnerability Assessments

Smart Metering Implementation Programme. Consultation on transitional arrangements in the Smart Energy Code

Georgia Public Service Commission. Hot Topics and Current Issues Bill Edge Public Information Officer Georgia Public Service Commission

EBR Application for Review Request to Review Environmental Compliance Approval Cruickshank Construction Limited Elginburg Quarry, Kingston

Consistent Measurement of Broadband Availability

Cisco Smart Grid. Powering End-to-End Communications. Annette Winston Sr. Mgr., Product Operations Customer Value Chain Management

Pepco s Plans for Smart Grid. Rob Stewart Blueprint Technology Strategist

S K Gupta Advisor, TRAI

DHS Overview of Sustainability and Environmental Programs. Dr. Teresa R. Pohlman Executive Director, Sustainability and Environmental Programs

Transcription:

Tom A. Loski Chief Regulatory Officer Phone: 604-63-4046 Fax: 604-63-4407 bchydroregulatorygroup@bchydro.com February, 06 Ms. Erica Hamilton Commission Secretary British Columbia Utilities Commission Sixth Floor 900 Howe Street Vancouver, BC V6Z N3 Dear Ms. Hamilton: RE: British Columbia Utilities Commission (BCUC or Commission) British Columbia Hydro and Power Authority (BC Hydro) Smart Metering & Infrastructure (SMI) Program Quarterly Update Report No. 3 October to December 05 (Report) BC Hydro writes in compliance with Commission Order No. G-67-0, to provide its Report. The SMI Program will be complete in March 06. With the SMI Program s completion, BC Hydro will not be filing any further quarterly progress reports. A final report for the SMI Program is planned for submission in summer 06. For further information, please contact Geoff Higgins at 604-63-4 or by email at bchydroregulatorygroup@bchydro.com. Yours sincerely, Tom Loski Chief Regulatory Officer st/rh Enclosure Copy to: BCUC Project No. 36986 (Fiscal 04 to Fiscal 04 Revenue Requirements Application) Registered Intervener Distribution List. British Columbia Hydro and Power Authority, 333 Dunsmuir Street, Vancouver BC V6B 5R3 www.bchydro.com

Quarterly Update Report No. 3 F06 Third Quarter October 05 to December 05

Table of Contents Introduction... Meter Choices Program... 3 3 Project Status... 5 4 Project Schedule... 5 5 Project Costs: F06 Q3 and Program to Date... 0 List of Tables Table Measurement Points from System Devices Breakdown As of December 3, 05... 3 Table Meter Choices Program Participation Breakdown As of December 3, 05... 4 Table 3 Project Schedule F06 Q3... 6 Table 4 Project Schedule F06 Q4... 7 Table 5 Customer Mass Meter Deployment June 0 Schedule and Actuals... 9 Table 6 SMI Program Operating and Capital Expenditures F06 Q3 and Forecast at Completion... 0 Table 7 SMI Program Operating and Capital Expenditures F06 Year to Date... Table 8 SMI Program Operating and Capital Expenditures SMI Program to Date... Table 9 SMI Program Operating and Capital Expenditures by SMI Program Component F06 Q3... Table 0 SMI Program Operating and Capital Expenditures by SMI Program Component F06 Year to Date... 3 Table SMI Program Operating and Capital Expenditures by SMI Program Component SMI Program to Date and Forecast at Completion of Program... 4 Appendices Appendix A SMI Program Contracts and Commitments Executed in F06 Q3 Page i

3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 Introduction This Smart Metering & Infrastructure (SMI) Quarterly Report No. 3 covers the Third Quarter of Fiscal 06 (F06 Q3), the period from October, 05 to December 3, 05 and is submitted in accordance with Directive 6 of Commission Order No. G-67-0. Program expenditures are categorized as identified in Directive 4 of Commission Order No. G-67-0. As set out in BC Hydro's letter to the Commission dated March 8, 0 regarding SMI Quarterly Report No. 3, Table 6 and Table include estimated total SMI Program expenditures at the completion of the program. In accordance with Directive 5 of Commission Order No. G-5-, a description and value of contracts and commitments related to the SMI Program undertaken during F06 Q3 is provided in Appendix A. This report also identifies the number of smart meters in the field and the number of remaining smart meter installs, both as of December 3, 05. Additional tables which identify total program expenditures to date are also included. This report also identifies the level of participation in the Meter Choices Program as of December 3, 05. BC Hydro's activities with respect to the SMI Program in F009 and F00 focused on foundational program elements, such as meter system technologies and information technology requirements. In F0, BC Hydro's SMI Program activities focused on the design, issuance and completion of procurement processes for four primary work packages, and the award of major contracts that were on the critical path for the deployment of metering infrastructure for the SMI Program. SMI Program procurement activities continued in F0, and focused on the development of the theft detection solution components including Distribution System Metering Devices (DSMD), and the Energy Analytics Solution (EAS) theft analytics software. BC Hydro's SMI Program activities in F03 included the completion of mass deployment of smart meters, the continued installation of telecommunications infrastructure and implementation of related information systems, procurement processes related to DSMD and the EAS, and the field testing Page

3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 and deployment of DSMD. In F04, program activities focused on the procurement of DSMD, the development of the EAS, telecommunications network optimization, implementation of the Meter Choices Program, and the installation of smart meters that were not included as part of the mass deployment. In F05 SMI Program activities focused on completing the network optimization and the installation of telecommunications infrastructure, migrating the meters and the network to a more advanced networking protocol (IPv6), expanding on the EAS capabilities, and implementation of the DSMD (transformer and feeder meters) and their associated applications. In F06 SMI Program activities have focused on completing the network optimization and the installation of telecommunications infrastructure, migrating the meters and the network to IPv6, introducing Energy Balancing capabilities across distribution feeders supported by Supervisory Control and Data Acquisition (SCADA) devices, Check Meters, transformer rebate meters and other distribution equipment and their associated applications. As of December 05, the SMI Program completed the requirements of the Smart Meters and Smart Grid Regulations under The Clean Energy Act, Section 7 by putting in place a program for theft detection using more than 9,000 measurement points from system devices, implementing energy analytics software to perform energy balancing and implementing a network of WiMAX base station sites and Subscriber Units which are successfully transporting data from nearly one million smart meters throughout BC Hydro s service territory. Table shows the composition of measurement points from system devices as of December 3, 05. Page

3 Table Measurement Points from System Devices Breakdown As of December 3, 05 System Devices SCADA Devices (Reclosers, Relays, Bus Voltage, Switches, Voltage Regulators and Capacitor Banks) Number of Measurement Points from System Devices 4,44 Transformer Rebate Meters ( Rate Class) 3,045 Check Meters for Temporary Rotational Purposes,000 Check Meters Deployed in Fixed Locations 548 First Generation Device Measurements (Feeder Meters and Transformer Meters, Field Metrics) Total 9,6 09 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 Meter Choices Program On July 8, 03, the Minister of Energy and Mines announced that in response to public concerns, BC Hydro would offer new options for customers who delayed their smart meter installation. On September 5, 03, the Government of British Columbia issued Direction No. 4 providing direction to the Commission with respect to implementing Government policy. On October 7, 03 BC Hydro filed its Application for approval of charges related to the Meter Choices Program, offering eligible customers an installation of a standard smart meter at no cost, or an installation of a radio-off meter, or the existing legacy meter at the premises for a fee approved by the Commission. On April 5, 04, the Commission issued Order No. G-59-4 and set the charges related to the Meter Choices Program on a permanent basis. On July 3, 04, in accordance with the updated tariff approved by the Commission on July, 04, BC Hydro applied the missed read credit adjustment including interest to the accounts of Meter Choices Program customers that had estimated scheduled readings from the start of the Meter Choices Program to July 30, 04. The composition of Meter Choices Program participants as of December 3, 05 is identified in Table. Page 3

Table Meter Choices Program Participation Breakdown As of December 3, 05 Option Number of Accounts Legacy Meter,669 Selected Radio-off 65 Total 3,3 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 All BC Hydro electricity meters are required to have a valid Measurement Canada accuracy seal. In 04, BC Hydro was required, under Measurement Canada Regulations, to exchange 0,700 Meter Choices customers legacy meters because the accuracy seal had expired. These meters must be replaced by a meter with a valid Measurement Canada seal. BC Hydro sent letters to customers explaining why the BC Hydro legacy meter at their premises was being replaced with another legacy meter. Of these customers, approximately,600 refused to permit BC Hydro to exchange the time expired meter at their premises. BC Hydro is continuing to work with these customers and as of December 3, 05, of the approximately,600 customers who refused access,,80 customers have had their meter replaced. Out of the remaining 790 customers, 360 have consented to replacement of the legacy meter with another legacy meter, and 430 customers still require a resolution. In late March 05, an additional,30 letters were sent to customers informing them that the Measurement Canada accuracy seal on the legacy meters at their premises would expire in 05 and require meter exchange. Of these, 65 customers were informed that because the stock of legacy meters for their service type has been exhausted, a radio-off meter or a smart meter at the Customer s election will need to be installed. As of December 3, 05, of the,30 customers to whom letters were sent, 955 customers have had the meter on their premises exchanged, 95 work orders have been issued to replace legacy meters with smart meters, 0 work orders have been issued to replace legacy Page 4

3 4 5 meters with radio off meters, and 60 legacy meters still require meter exchange with another legacy meter. The Measurement Canada accuracy seals of all legacy meters remaining in service will expire in subsequent years through 0, at which point all legacy meters will have expired seals and require replacement. 6 7 8 3 Project Status During F06 Q3, BC Hydro took the following steps to advance and implement the SMI Program: 9 0 3 4 5 6 7 Continued deployment of customer meters; Continued transition of customers to automated billing; Completed deployment of advanced telecom equipment; Continued telecom network optimization; Continued work related to the Meter Choices Program including exchanges of legacy meters with expired seals; Completed EAS functional deployment; Completed integration of SCADA capable devices; and Implemented Disaster Recovery Capability. 8 9 0 4 Project Schedule Table 3 shows the status of the major activities in F06 Q3 as reported in F06 Q Quarterly Report No.. Page 5

Table 3 Project Schedule F06 Q3 Date Activity October 05 In Field/Over the Air Meter Mitigation Network Stability Continue Network Stabilization and Optimization Upgrade of Automated Data Collection System (ADCS), Meter Data Management System (MDMS) and Network Management System (NMS) to new software versions Operational Insights Build Meter Choices Program: Install Radio Off & Smart Meters SCADA Recloser Reconfiguration SCADA Infrastructure and Reclosers Field Upgrades SCADA Relay Resolution Reconfiguration Check Meter Device Testing and Soft Deployment EAS b (SCADA and Check Meters) Functional Deployment Disaster Recovery Capability Network Failover Design Advanced Telecom: WiMAX Complete Complete November 05 In Field/Over the Air Meter Mitigation Network Stability Continue Network Stabilization and Optimization Operational Insights Build Meter Choices Program: Install Radio Off & Smart Meters Itron Cellular Solution Meter Deployment SCADA Recloser Reconfiguration SCADA Infrastructure and Reclosers Field Upgrades SCADA Relay Resolution Reconfiguration Check Meter Device Testing and Soft Deployment EAS b (SCADA and Check Meters) Advanced Deployment Disaster Recovery Capability Failover Network Testing Advanced Telecom: WiMAX Complete Commenced Complete December 05 In Field/Over the Air Meter Mitigation Network Stability Complete Continue Network Stabilization and Optimization Operational Insights Testing and Deployment Meter Choices Program: Install Radio Off & Smart Meters Itron Cellular Solution Meter Deployment SCADA Recloser Reconfiguration SCADA Infrastructure and Reclosers Field Upgrades Transitioned to Sustainment Complete Complete Page 6

Date Activity SCADA Relay Resolution Reconfiguration Check Meter Device Deployment Disaster Recovery Capability Production Turnover Complete Complete Table 4 shows the major activities included in the project schedule for the fourth quarter of F06. 3 Table 4 Project Schedule F06 Q4 Date January 06 February 06 March 06 Activity Continue Network Stabilization and Optimization Operational Insights Testing Itron Cellular Solution Meter Deployment EAS Defect Resolution Release Check Meter Device Deployment Continue Network Stabilization and Optimization / Transition to Sustainment Operational Insights Final Deployment Itron Cellular Solution Meter Deployment EAS Defect Resolution Release Check Meter Device Deployment Operational Insights Transition to Sustainment Itron Cellular Solution Meter Deployment / Transition to Sustainment EAS Warranty and Transition to Sustainment Check Meter Device Deployment / Transition to Sustainment Final Asset Capitalization Finalize Project Completion and Evaluation Report Project Closure 4 5 6 7 8 9 Meter deployment continued throughout F06 Q3, increasing the total number of smart meters installed by 9,30 during the quarter, none of which were installed by Corix, as shown in Table 5. On December 3, 05, there were,937,836 smart meters in the field, and,706 conventional meters remaining in the field (excluding,669 legacy meters remaining under the Meter Choices Program). Page 7

3 4 During the third quarter of F06, two Field Area Network (FAN) collectors (Cisco Connected Grid Routers) were installed, bringing the total number installed to,85 by the end of F06 Q3. Six Range Extenders were installed during the quarter, bringing the total number in the field at the end of the quarter to 5,64. Total number of Range Extenders installed as at September 30, 05 was 5,58. Quarterly Report No. incorrectly reported this number as 5,4. Page 8

Table 5 Customer Mass Meter Deployment June 0 Schedule and Actuals Smart Metering and Infrastructure Program June 0 Customer Meter Deployment Plan and Actuals Corix Installations (June 0 Plan) Region Total Meters Fiscal 0 Fiscal 03 Fiscal 04 Fiscal 05 Q Q3 Q4 Q Q Q3 Q4 Q Q Q3 Q4 Q Q Q3 Q4 Q Q Q3 Total Corix Installations (June 0 Plan) Lower Mainland South 444,5 5,54 7,90 7,050 3,63 4,70-444,5 North Interior 04,367 6,63,4 4,9 3,5 7,979-04,367 North Coast 4,43 3,65,05 5,7,635 66-4,43 Vancouver Island 387,895 6,765 76,9 80,599 8,660 77,68 45,4 387,895 Lower Mainland North (Metro) 63,6 4,875 35,68 5,653 54,563 34,737 3,0 63,6 368,3 4,875 95,8 07,867 68,404 7,35 0,568 368,3 38,06-0,000 8,06 - - - 38,06 83,534 - - - - 63,000 0,534 83,534 78,9 - - 6,580 6,33 - - 78,9 4,50 - - - 3,88 4-4,50 8,975-8,975 - - - - 8,975,44 -,44 - - - -,44 South Interior 9,966-30,44 3,8 38,87 66,637 3,933 9,966 Kootenay 54,438 - - - 5,803 3,34 6,3 54,438 Planned Corix Installations (June 0 Plan),848,94,60 4,960 43,586 49,667 354,64 06,460,848,94 To End of Q3 F06 Actual Corix Installations,769,69 6,583 4,563 45,796 385,34 6,57 70,307 6,9 3,48 6 4,54 0,07 6,54 909 - - - - -,769,69 Actual BC Hydro Installations 68,07 * Total Smart Meter Installations,937,836 Fiscal 06 Conventional Meters Remaining in Field (Excl. Meter Choices Program),706 * Includes smart meters installed due to growth in the number of customer accounts during the deployment. Page 9

5 Project Costs: F06 Q3 and Program to Date Actual operating expenditures during F06 Q3 were $.4 million, which is $0.9 million more than planned due to delayed transition to sustainment activities related to Smart Grid. Actual capital expenditures during F06 Q3 were $0.3 million, which is $5.7 million less than planned primarily due to program savings related to Smart Grid. Forecast operating and capital expenditures at the completion of the program have been adjusted downward from $848.7 million to $777.0 million. The reduction in forecast is primarily composed of $7.5 million of contingency that will not be required. Operating and capital expenditures related to the SMI Program incurred by BC Hydro in F06 Q3 and for the SMI Program to date are shown in Table 6, Table 7 and Table 8 respectively. Table 6 SMI Program Operating and Capital Expenditures F06 Q3 and Forecast at Completion Operating Expenditures Capital Expenditures Forecast at Completion ($) ($ million) Actual Plan Variance Actual Plan Variance Operating Capital Labour 0. 0.4 0.3.0 0.6 (0.4) 8.3 53. Consultants and Contractors.3 0. (.) 4.8 6.0. 43.7 356.5 Materials/Other 0.0 0.0 0.0 4. (.0) (5.) (8.3) 9.6 Interest n/a n/a n/a 0.3 0.4 0. n/a.0 Sub-total SMI Program Interest on Deferral.4 0.5 (0.9) 0.3 6.0 5.7 63.7 73.3 n/a n/a n/a n/a n/a n/a n/a n/a Total.4 0.5 (0.9) 0.3 6.0 5.7 777.0 In Table 5 (SMI Program Operating and Capital Expenditures F06 Q and Forecast at Completion) of the SMI Quarterly Update Report No., the full amount of the Contingency ($7.5 million) was erroneously allocated in the Materials/Other category as Capital under Forecast at Completion. Contingency should have been divided between Operating and Capital under Forecast at Completion; subtotaling in Sub-total SMI Program row as $64 million and $784.7 million respectively. Page 0

Table 7 SMI Program Operating and Capital Expenditures F06 Year to Date Operating Expenditures Capital Expenditures ($ million) Actual Plan Variance Actual Plan Variance Labour 0.3 0.9 0.6.6.9 (0.7) Consultants and Contractors.8.0 (0.8).4 46. 4.7 Materials/Other 0.0 0.0 0.0 7. (3.9) (.0) Interest n/a n/a n/a.0. 0. Sub-total SMI Program Interest on Deferral..9 (0.) 3. 45. 3. n/a n/a n/a n/a n/a n/a Total..9 (0.) 3. 45. 3. Table 8 SMI Program Operating and Capital Expenditures SMI Program to Date ($ million) Operating Expenditures Capital Expenditures Total Expenditures Labour 7.9 5.8 80.7 Consultants and Contractors 4.5 345.3 387.8 Materials/Other (8.3) 90.4 8. Interest n/a.8.8 Sub-total SMI Program 6. 700.3 76.4 Interest on Deferral 7.5 n/a 7.5 Total 69.6 700.3 769.9 Operating and capital expenditures by program component 3 for F06 Q3, F06 Year to Date, and SMI Program to date are presented in Table 9, Table 0 and Table respectively. 3 In Directive No. 4 of Commission Order No. G-67-0, BC Hydro was directed to report SMI Program costs broken down by the components specified therein. Page

Table 9 SMI Program Operating and Capital Expenditures by SMI Program Component F06 Q3 Operating Expenditures Capital Expenditures ($ million) Actual Plan Variance Actual Plan Variance Smart Meters 0. 0.0 (0.) 0. 0.3 0. Telecommunications Systems 0.0 0.0 0.0 (0.9) 0.0 0.9 Meter Data Management System 0.0 0.0 0.0 0.0 0.0 0.0 Solution Integration 0.0 0.0 0.0 0.9 0. (0.7) In-Home Display/In-Home Feedback 0.0 0.0 0.0 0. 0.0 (0.) Conservation Based Rates 0.0 0.0 0.0 0.0 0.0 0.0 Smart Grid 0.9 0. (0.8) 9.3.7.4 Other Procurement 0.0 0.0 0.0 0.0 0.0 0.0 Program Management 0.0 0.0 0.0 0.0 0. 0. Facilities 0. 0.0 (0.) 0.4 0.0 (0.4) Finance 0.0 0.0 0.0 0. 0.5 0.3 Human Resources 0.0 0.4 0.4 0.0 0.0 0.0 Contract Management 0.0 0.0 0.0 0. 0. (0.) IT Infrastructure 0.0 0.0 0.0 0.0 0.0 0.0 Security 0.0 0.0 0.0 0.0 0.0 0.0 Communications & Stakeholder Engagement 0.0 0.0 0.0 0.0 0.0 0.0 Regulatory 0.0 0.0 0.0 0.0 0.0 0.0 Transition to Operations 0. 0.0 (0.) 0.0 0.0 0.0 Interest During Construction 0.0 0.0 0.0 0.0 0.0 0.0 Total Other 0.3 0.4 0. 0.8 0.8 0.0 Contingency 0.0 0.0 0.0 0.0 3.0 3.0 Total.4 0.5 (0.9) 0.3 6.0 5.7 Smart Grid includes theft detection and other advanced telecom infrastructure related expenditures. Interest during construction is included in actual expenditures for each expenditure category, but not included in planned expenditures by category. Therefore, a separate line item is included in Other. Page

Table 0 SMI Program Operating and Capital Expenditures by SMI Program Component F06 Year to Date Operating Expenditures Capital Expenditures ($ million) Actual Plan Variance Actual Plan Variance Smart Meters (0.3) (0.4) (0.).4.3 (0.) Telecommunications Systems Meter Data Management System 0.0 0.0 0.0 (.9) 0.0.9 0.0 0.0 0.0 0.0 0.0 0.0 Solution Integration 0.0 0.0 0.0.5.5 (.0) In-Home Display/In-Home Feedback 0.0 0. 0. 0. 0. 0.0 Conservation Based Rates 0.0 0.0 0.0 0.0 0.0 0.0 Smart Grid.9.3 (0.6) 8. 35.8 7.6 Other Procurement 0.0 0.0 0.0 0.0 0.0 0.0 Program Management 0.0 0. 0. 0.0.. Facilities 0. 0.0 (0.) 0.7 0.0 (0.7) Finance 0.0 0.0 0.0 0.6.5 0.9 Human Resources 0.0 0.6 0.6 0.0 0.0 0.0 Contract Management 0.0 0.0 0.0 0.4 0.4 0.0 IT Infrastructure 0.0 0.0 0.0 0.0 0.3 0.3 Security 0.0 0.0 0.0 0. 0. 0.0 Communication & Stakeholder Engagement 0. 0. 0.0 0.0 0.0 0.0 Regulatory 0.0 0.0 0.0 0.0 0.0 0.0 Transition to Operations 0. 0. (0.) 0.0 0.0 0.0 Interest During 0.0 0.0 0.0 0.0 0.0 0.0 Construction Total Other 0.5 0.9 0.4.8 3.5.7 Contingency 0.0 0.0 0.0 0.0 3.0 3.0 Total..9 (0.) 3. 45. 3. Smart Grid includes theft detection and other advanced telecom infrastructure related expenditures. Interest during construction is included in actual expenditures for each expenditure category, but not included in planned expenditures by category. Therefore, a separate line item is included in Other. Page 3

Table SMI Program Operating and Capital Expenditures by SMI Program Component SMI Program to Date and Forecast at Completion of Program ($ million) Operating Expenditures Actual Expenditures Program to Date Capital Expenditures Total Expenditures Forecast Expenditures - Completion of Program Operating Capital Smart Meters.4 359. 370.6.9 359.3 Telecommunications Systems Meter Data Management System 0.4 39.5 39.9 0.4 39.5 0. 8. 8.3 0. 8. Solution Integration 0.0 53.7 53.7 0.0 53.7 In-Home Display/In-Home Feedback Conservation Based Rates 7.3 9. 6.5 7.3 9.3 0.0 3.9 3.9 0.0 3.9 Smart Grid.3 44.3 56.6 3.0 56.6 Other Program Management 4.6 0.3 4.9 4.6 0.5 Facilities.3 4.9 7..3 4.9 Finance.7 4.9 7.6.7 4.9 Regulatory (8.7) 0.0 (8.7) (8.7) 0.0 Procurement 0. 0.3 0.4 0. 0.3 Contract Management 0.0.. 0.0.3 Customer.6 0.0.6.6 0.0 Business Transformation Engineering, IT, Telecom, Security & Field Trials.0 0.0.0.0 0.0 3.4 0.0 3.4 3.4 0.0 Utility Operations.4 0.0.4.4 0.0 Human Resources 0.9 0.5.4. 0.5 Communication & Stakeholder Engagement.3 0.0.3.3 0.0 Page 4

Transition to Operations Leasehold Improvements Field Trial Equipment Actual Expenditures Program to Date Forecast Expenditures - Completion of Program 0.6 0.0 0.6 0.7 0.0 0.0 0.4 0.4 0.0 0.4 0.0 0.0 0.0 0.0 0.0 Security 0.0.0.0 0.0.0 Infrastructure (IT) 0.0 6.9 6.9 0.0 6.9 Program 7.3 0.0 7.3 7.3 0.0 Development Interest During 0.0 0.0 0.0 0.0 0. Construction 3 Total Other 30.5 7.4 0.9 30.9 7.9 Contingency 0.0 0.0 0.0 0.0 0.0 Total 6. 700.3 76.4 63.7 73.3 3 777.0 Smart Grid includes theft detection and other advanced telecom infrastructure related expenditures. Program Initiation and Identification includes expenditures of $7.3 million incurred during F006 and F008 (inclusive). These amounts were expensed in the year in which they were incurred, although only $0.6 million was recovered in rates (i.e., $6.7 million was incurred ex-plan). Interest during construction is included in actual expenditures for each expenditure category, but not included in planned expenditures by category. Therefore, a separate line item is included in Other. Page 5

Quarterly Update Report No. 3 Appendix A SMI Program Contracts and Commitments Executed in F06 Q3

Appendix A Supplier/Vendor Contract Value ($) Description A.T. maintenance Plus Contracting 40,96 Smart Meter Installation Services Annex Consulting Group Inc. 50,704 IT Resources BellTech Systems Ltd. 00,000 Network Equipment Installation Blackcomb Helicopters LP 6,594 Helicopter Use for Advanced Telecom Network Enhancement Brainhunter Systems Ltd. 30,080 IT Resources Capgemini Canada Inc. 5,384 IT Resources Compugen Inc. 5,658 Disaster Recovery Consulting Services Corix Utilities Inc. 3,036,90 Smart Meter Installation Services EMC Corporation of Canada 68,503 Energy Analytics Solution Services Fred Thompson Contractors,05 Advanced Telecom Services HD3 Networks Inc. 56,60 IT Resources Howe Sound Consulting Inc. 43,375 DSMD Resource Hwoiken Consulting Services 5,000 DSMD Resource JTS Consulting Inc. 4,680 IT, Accounting and Procurement Resources Modis Canada Inc. 7,040 IT Resource Oracle Canada ULC 9,4 Technology Equipment Procom Consultants Group Ltd 7,80 Security Services Quartech Systems Ltd. 3,40 IT and Project Management Resources Robert Half Canada Inc. 7,500 Project Accountant Smart Meter Deployment Consulting 78,000 Deployment Consultant Teema Solutions Group Inc. 43,0 IT Resource Teksystems Canada Inc. 365,638 IT and Project Management Resources Telus Communications Company 8,43 Telecom Infrastructure Services Valley Power Line Contracting Ltd. 6,80 DSMD Services West Pacific Consulting Group 48,356 IT Resources Yuitech Solutions Ltd. 38,700 IT Resource Total 5,36,93 Page of