WIZ125SR User Manual

Similar documents
WIZ110SR User s Manual

WIZ120SR User s Manual (Version 1.0)

(V 1.1) 2006 WIZnet Inc. All Rights Reserved. For more information, visit our website at 0/23

WIZ105SR User s Manual

WIZ1000 User s Manual

WIZ107SR User Manual

WIZ100SR User s Manual

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)

WIZ140SR/WIZ145SR Datasheet

(Version 1.0) 2011 WIZnet Co., Ltd. All Rights Reserved. For more information, visit our website at

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

WIZ200WEB User s Manual (Ver. 1.0)

WIZnet s. If you have any. write

WIZ6000 User s Manual

WIZ-iStorage User Manual

WIZ107SR User Manual. Version WIZnet Co., Ltd. All Rights Reserved. For more information, visit our website at

ECOV-110 User s Manual

WIZ127SR User s Manual (Version 1.0)

WIZ850SW User Manual. (Ver. 1.0) 2009 WIZnet Inc. All Rights Reserved. For more information, visit our website at

Serial to Ethernet Converter

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HDMI Extender over Ethernet, with RS232, POE

WIZ127SR User s Manual (Version 1.11)

Industrial Serial Device Server

ecov-110 User s Manual (V0.9f_Eng)

LM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections

WIZ108SR User Manual. Version WIZnet Co., Ltd. All Rights Reserved. For more information, visit our website at

RS-232/422/485 Over IP Adapter

NordField Electronics

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

WM-120. Serial to Ethernet Module. Serial to Ethernet Module. User Manual. Version 1.0. Infosystem Technology Corporation, Ltd.

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

Tel: Fax:

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

WIZ-iRadio User s Manual

1 port RS-232 Device Server

TCP/IP Converter. EX-9132 Operation Manual for 8051 Series

imcu7100evb User s Guide

Model XS1000 TCP/IP to RS232/422/485 Device Server User s Manual

Ethernet-232 User s Manual

SERIAL TO ETHERNET CONVERTER E-P User Manual

User s Guide. Ethernet Module for Barcode Printer

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

Infosystem. User Manual. Version 1.0. Serial to Ethernet Converter with 3 sockets. Infosystem Technology Corporation, Ltd.

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Data-Tronix DT-HDVD-M2MLT-ENC DT-HDVD-M2MLT-RX. H.264 HDMI video Encoder and. H.264 HDMI video Decoder. User Manual. 15 Version: V1.0.

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NetBiter Serial Server User Manual

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

SURGE PROTECTION DEVICE RECOMMENDED

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

ZLAN5443A. User Manual

PCI Express 16-Port Serial I/O Cards

CHIYU. Product Specification BF-450(M)/BF-430. RS232/RS485/RS422 To TCP/IP Converter Module. Release 1.0

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Website: Toll Free: [US] USER MANUAL

TRP-C37 User s Manual

8x8 HDMI2.0 Matrix Support YUV4:4:4, 18Gbps, HDR. Operating Instruction

Serial Device Server- Dual Port Quick Installation Guide

2-Port RS-232/422/485 Serial over IP Ethernet Device Server Installation Guide

Operation Manual of EX9132CST-Series

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Ocean Sensor Systems, Inc. Wave Gauge Blue, OSSI A Self Logging/Self Powered Pressure Sensor

WiFi A/V Module. (Model: WM-CAM)

Website: Toll Free: [US] USER MANUAL

Dual Serial Shield User Manual

TRP-C37M User s Manual

User Manual A08. User Manual

Modbus Gateway User's Manual ADM-5850G

MEC-COM-M114. User s Manual

NPort 5000AI-M12 Series

USR-TCP Hard version: V2.0 File version: V

BF-430 User Manual Document Version 1.0 Web Version realcom Firmware Version ,Apr

ABLELink. Modbus Gateway MB5000 Series User s Manual

e-net TCP/IP Converters

4x4 HDMI2.0 Matrix Support YUV4:4:4, 18Gbps, HDR. Operating Instruction

Bluetooth RS232 Serial Adapter

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

SERIAL TO WiFi CONVERTER EX-9486C-W User Manual

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

PCI Express 4-Port Industrial Serial I/O Cards

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

Industrial Device Server IDS-3010 Fiber Series

ZLSN2002 Embedded Device Networking Module. User Manual

LCM-100 LCD Module User s Manual

EZL-400S User s Manual

PCIe-400 USER S MANUAL

User Manual Edition: v a

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

NE-4100 Series Serial Command Mode User s Guide

SerialComm ETH-SER-EE9 Serial Device Server / Ethernet to Serial Converter User Manual

EX-6014WI RS232 to WiFi Wireless Adapter, w/ Mounting Kit

MEC-COM-M154. User s Manual

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

Transcription:

WIZ125SR User Manual ( Version 1.0 ) 2010 WIZnet Co., Ltd. All Rights Reserved. For more information, visit our website at http://www.wiznet.co.kr WIZ125SR User Manual (WIZnet Co., Ltd.) - 1 -

Document Revision History Date Revision Changes 2010-04-20 V1.0 Official Release WIZ125SR Manual (WIZnet Co., Ltd.) - 2 -

WIZnet s Online Technical Support If you have any questions about our products, please visit our website and submit your questions on the Q&A Board. We will reply your questions as soon as possible CLICK COPYRIGHT NOTICE Copyright 2010 WIZnet Co., Ltd. All Rights Reserved. Technical Support: support@wiznet.co.kr Sales & Distribution: sales@wiznet.co.kr For more information, visit our website at http://www.wiznet.co.kr WIZ125SR Manual (WIZnet Co., Ltd.) - 3 -

Contents 1. Introduction... 1 1.1 Key Features... 1 1.2 Product Specifications... 2 1.3 WIZ125SR Interface... 3 2. Serial Configuration... 4 2.1 Serial Command Format... 4 2.2 WIZ125SR Configuration with Serial Command... 9 3. Hardware Specification... 11 3.1 WIZ125SR Dimension... 11 3.2 Connector Specification... 12 3.2.1 RJ-45 Connector... 12 3.2.2 DB-9 Connector... 12 4. Warranty... 13 WIZ125SR Manual (WIZnet Co., Ltd.) - 4 -

Figures FIGURE 1. WIZ125SR INTERFACE... 3 FIGURE 2. SERIAL CONFIGURATION ENABLE SETTING... 9 FIGURE 3. WIZ125SR DIMENSIONS (UNIT : MM)... 11 FIGURE 4. RJ-45 PIN ASSIGNMENT... 12 WIZ125SR Manual (WIZnet Co., Ltd.) - 5 -

Tables TABLE 1. WIZ125SR SPECIFICATIONS... 2 TABLE 2. SERIAL CONFIGURATION FRAME FORMAT... 4 TABLE 3. SERIAL CONFIGURATION REPLY FRAME FORMAT... 4 TABLE 4. SERIAL CONFIGURATION STX & ETX... 4 TABLE 5. SERIAL CONFIGURATION REPLY CODE... 5 TABLE 6. SERIAL CONFIGURATION COMMAND CODE... 8 TABLE 7. SERIAL CONFIGURATION TEST PROCEDURE... 10 TABLE 8. DB-9 RS-232C CONNECTOR PIN-ASSIGNMENT... 12 WIZ125SR Manual (WIZnet Co., Ltd.) - 6 -

1. Introduction WIZ125SR is a 2 ports gateway module that converts RS-232 protocol into TCP/IP protocol. It enables remote gauging, remote management of the device through the network based on the Ethernet and the TCP/IP by connecting to existing equipments with RS-232 serial interface. In other words, WIZ125SR is a protocol converter that transmits the data sent by serial equipment as TCP/IP data type and converts back the TCP/IP data received through the network into serial data to transmit back to the equipment. WIZ125SR has been designed by using WIZ120SR module and WIZ120SR-EVB. Therefore all functions and operations are identical with WIZ120SR module. Refer to the WIZ120SR User Manual for detail description. 1.1 Key Features Direct connection to the serial device Adding network function simply and quickly Providing Firmware customization Support 2 Port Serial System Stability and Reliability by using W5100 Hardware Chip Supports PPPoE Connection Support User Password function for security Supports Serial Configuration with Simple and Easy command Supports Password for the Security Configuration Tool Program 10/100 Ethernet Interface and max 230Kbps Serial Interface Support DNS function RoHS Compliant WIZ125SR User Manual (WIZnet Co., Ltd.) 1

1.2 Product Specifications Category Protocol Network Interface Serial Port CPU Serial line format Serial flow control Serial signal Software Serial Transmission Speed Temperature Specification TCP, UDP, IP, ARP, ICMP, IGMP, MAC, DHCP, PPPoE, DNS 10/100 Base-T Ethernet (Auto detection) / RJ-45 RS-232C DB-9 2port Cortex-M3 Core 8-N-1, 8-O-1, 8-E-1, 7-O-1, 7-E-1 None, XON/XOFF, CTS/RTS TXD, RXD, RTS, CTS, GND Remote Download and Configuration 1200bps ~ 230Kbps 0 ~ 70 C (Operating), -40 ~ 85 C (Storage) Humidity 10~90% Power DC 5V, 220mA(MAX) Size 88.5mm x 65.5mm x 18mm ( Include connector size ) Table 1. WIZ125SR Specifications WIZ125SR User Manual (WIZnet Co., Ltd.) 2

1.3 WIZ125SR Interface Figure 1. WIZ125SR Interface WIZ125SR User Manual (WIZnet Co., Ltd.) 3

2. Serial Configuration 2.1 Serial Command Format Serial Command is used to set WIZ125SR parameter. This function is using S/W trigger of WIZ125SR, if input specific letters(three characters), you can start configuration mode. User can set any special character with the configuration tool, and this function support UART 0 only. Command Frame format Descriptor STX Command code Parameter ETX Length(bytes) 1 2 Variable 1 Table 2. Serial Configuration Frame format Reply Frame format Descriptor STX Reply code Parameter ETX Length(bytes) 1 1 Variable 1 STX & ETX Table 3. Serial Configuration Reply Frame format Setting Comments STX < : Hex = 3Ch ETX > : Hex = 3Eh Table 4. Serial Configuration STX & ETX Reply Code Reply Comments S Command was successful WIZ125SR User Manual (WIZnet Co., Ltd.) 4

F Command failed 0 Invalid STX 1 Invalid command 2 Invalid parameter 3 Invalid ETX E Enter Serial Command Mode Table 5. Serial Configuration Reply Code Command Code Command Parameter Comments WI xxx.xxx.xxx.xxx (eg. 192.168.11.133) Set Local IP WS xxx.xxx.xxx.xxx (eg. 255.255.255.0) Set Subnet mask WG xxx.xxx.xxx.xxx (eg. 192.168.11.1) Set Gateway Set common parameter WD 0 : Static, 1 : DHCP, 2 : PPPoE Set the IP configuration method WT 0 : Disable, 1 : Enable Set the serial command method WE xxxxxx (eg. In hex format : 2B 2B 2B) Set the command mode character WY PPPoE ID Set PPPoE ID WZ PPPoE Password Set PPPoE Password WR WP 0~65535 Restart Set Local IP s port number for UART0 WM 0 : TCP Client, 1 : TCP Mixed, 2 : TCP Server Set the TCP operation mode for UART0 Set UART0 WK 0 : TCP, 1 : UDP Set Protocol(TCP or UDP) for UART0 parameter WB XXXX eg. [Baudrate]1: 115200, 2: 57600, 3: 38400, 4: 19200, 5: 9600, 6: 4800, 7: 2400,8: 1200 Set the serial baud rate, data, parity and flow control for UART0. 4bytes:[Baud][data byte][parity][flow] [data byte] 7 : 7bit, 8bit WIZ125SR User Manual (WIZnet Co., Ltd.) 5

[parity] 0 : no parity, 1 : Odd, 2 :Even [Flow] 0 : no, 1 : Xon/Xoff, 2 :RTS/CTS WU 0 : Disable, 1 : Enable Set DNS option for UART0 WV xxx.xxx.xxx.xxx (eg. 255.255.255.0) Set DNS IP for UART0 WW xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx (eg. wiznet.co.kr) Set Domain for UART0 WX xxx.xxx.xxx.xxx (eg. 192.168.11.144) Set server IP address for UART0 WN 0~65535 Set server port number for UART0 WC XX Set delimiter character in hex for UART0 WJ 0~255 Set delimiter size for UART0 WH 0~65535 Set delimiter time for UART0 WL 0~65535 Set Inactivity timer value for UART0 OP 0~65535 Set Local IP s port number for UART1 OM 0 : TCP Client, 1 : TCP Mixed, 2 : TCP Server Set the TCP operation mode for UART1 OK 0 : TCP, 1 : UDP Set Protocol(TCP or UDP) for UART1 XXXX Set UART1 parameter OB eg. [Baudrate]1: 115200, 2: 57600, 3: 38400, 4: 19200, 5: 9600, 6: 4800, 7: 2400,8: 1200 [data byte] 7 : 7bit, 8bit Set the serial baud rate, data, parity and flow control for UART1. 4bytes:[Baud][data byte][parity][flow] [parity] 0 : no parity, 1 : Odd, 2 :Even [Flow] 0 : no, 1 : Xon/Xoff, 2 :RTS/CTS OU 0 : Disable, 1 : Enable Set DNS option for UART1 OV xxx.xxx.xxx.xxx (eg. 255.255.255.0) Set DNS IP for UART1 OW xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx (eg. wiznet.co.kr) Set Domain for UART1 OX xxx.xxx.xxx.xxx (eg. 192.168.11.144) Set server IP address for UART1 ON 0~65535 Set server port number for UART1 WIZ125SR User Manual (WIZnet Co., Ltd.) 6

OC XX Set delimiter character in hex for UART1 OJ 0~255 Set delimiter size for UART1 OH 0~65535 Set delimiter time for UART1 OL 0~65535 Set Inactivity timer value for UART1 RA MAC Address Get MAC Address RF x.x (eg. 1.0) Get the firmware version RI IP Address Get Local IP Get common parameter RS Subnet Mask Get Subnet mask RG Gateway address Get Gateway RD 0 : Static, 1 : DHCP, 2 : PPPoE Get the IP configuration method RT 0 : Disable, 1 : Enable Get the serial command method RE xxxxxx (eg. In hex format : 2B 2B 2B) Get the command mode character RY PPPoE ID Get PPPoE ID RZ PPPoE Password Get PPPoE Password RP RM Local Port Number 0 : TCP Client, 1 : TCP Mixed, 2 : TCP Server Get Local IP s port number for UART0 Get the operation mode for UART0 RK 0 : TCP, 1 : UDP Get the Protocol for UART0 XXXX eg. [Baudrate]1: 115200, 2: 57600, Get UART0 3: 38400, 4: 19200, 5: 9600, parameter RB 6: 4800, 7: 2400,8: 1200 Get the UART0 baud rate [data byte] 7 : 7bit, 8bit [parity] 0 : no parity, 1 : Odd, 2 :Even [Flow] 0 : no, 1 : Xon/Xoff, 2 :RTS/CTS RU 0 : Not use, 1 : Use Get DNS option for UART0 RV IP address Get DNS IP for UART0 RW Domain name Get Domain Name for UART0 RX xxx.xxx.xxx.xxx (eg. 192.168.11.144) Get the server IP address for UART0 WIZ125SR User Manual (WIZnet Co., Ltd.) 7

RN 0~65535 Get the server port number for UART0 RC XX Get delimiter character in hex for UART0 RJ 0~255 Get delimiter size for UART0 RH 0~65535 Get delimiter time for UART0 RL 0~65535 Get Inactivity timer value for UART0 QP QM Local Port Number 0 : TCP Client, 1 : TCP Mixed, 2 : TCP Server Get Local IP s port number for UART1 Get the operation mode for UART1 QK 0 : TCP, 1 : UDP Get the Protocol for UART1 XXXX OB eg. [Baudrate]1: 115200, 2: 57600, 3: 38400, 4: 19200, 5: 9600, 6: 4800, 7: 2400,8: 1200 [data byte] 7 : 7bit, 8bit Set the serial baud rate, data, parity and flow control for UART1. 4bytes:[Baud][data byte][parity][flow] Get UART1 parameter [parity] 0 : no parity, 1 : Odd, 2 :Even [Flow] 0 : no, 1 : Xon/Xoff, 2 :RTS/CTS QU 0 : Not use, 1 : Use Get DNS option for UART1 QV IP address Get DNS IP for UART1 QW Domain name Get Domain Name for UART1 QX xxx.xxx.xxx.xxx (eg. 192.168.11.144) Get the server IP address for UART1 QN 0~65535 Get the server port number for UART1 QC XX Get delimiter character in hex for UART1 QJ 0~255 Get delimiter size for UART1 QH 0~65535 Get delimiter time for UART1 QL 0~65535 Get Inactivity timer value for UART1 Table 6. Serial Configuration Command Code WIZ125SR User Manual (WIZnet Co., Ltd.) 8

2.2 WIZ125SR Configuration with Serial Command Figure 2. Serial Configuration enable setting 1 Check WIZ125SR Firmware version. If version is lower, download the latest firmware from download page of http://www.wiznet.co.kr, Serial configuration function is support firmware version 2.5 or later. 2 Connect the serial cable to UART 0. 3 Input any three characters for the serial command mode trigger (in above Figure, 2B, 2B, 2B are input) As above Figure, click Enable check box of serial configuration and save the Setting button. String fact for entering configuration mode is +++ ( + : 0x2B) 4 If you finish enable setting, you can test as below procedure. This procedure is checking module IP and change to other IP address 1 Input +++ Enter Serial Configuration mode 2 <E> Check Answer Notice Access Success 3 <WI192.168.11.3> input Change module IP to 192.168.11.3 WIZ125SR User Manual (WIZnet Co., Ltd.) 9

4 <S> Check answer Notice success IP setting 5 <RI> input check module IP address 6 <S192.168.11.3> Check answer check the changed module IP address 7 <WR> input reboot 8 <S> check answer Notice success of reboot command 9 Module reboot Table 7. Serial Configuration Test Procedure WIZ125SR User Manual (WIZnet Co., Ltd.) 10

3. Hardware Specification 3.1 WIZ125SR Dimension A 65.5 B 4.0 C 15.5 D 16.5 E 10.5 F 9.5 G 4.0 H 5.5 I 3.5 J 4.0 K 20.0 L 37.0 M 20.0 N 4.0 O 88.5 Figure 3. WIZ125SR Dimensions (unit : mm) WIZ125SR User Manual (WIZnet Co., Ltd.) 11

3.2 Connector Specification 3.2.1 RJ-45 Connector Pin Signal 1 TX+ 2 TX- 3 RX+ 6 RX- Figure 4. RJ-45 PIN Assignment 3.2.2 DB-9 Connector Pin Number Signal Description 1-2 RXD1 / RXD2 Receive Data for Port 1 & Port 2 3 TXD1 / TXD2 Transmit Data for Port 1 & Port 2 4-5 GND System Ground 6-7 RTS1 / RTS2 Request To Send for Port 1 & Port 2 8 CTS1 / CTS2 Clear To Send for Port 1 & Port 2 9 - Table 8. DB-9 RS-232C Connector PIN-Assignment WIZ125SR User Manual (WIZnet Co., Ltd.) 12

4. Warranty WIZnet Co., Ltd offers the following limited warranties applicable only to the original purchaser. This offer is non-transferable. WIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE(1) YEAR for the WIZ125SR board and labor warranty after the date of original retail purchase. During this period, WIZnet will repair or replace a defective products or part free of charge. Warranty Conditions: 1. The warranty applies only to products distributed by WIZnet or our official distributors. 2. The warranty applies only to defects in material or workmanship as mentioned above in 6.Warranty. The warranty applies only to defects which occur during normal use and does not extend to damage to products or parts which results from alternation, repair, modification, faulty installation or service by anyone other than someone authorized by WIZnet Inc. ; damage to products or parts caused by accident, abuse, or misuse, poor maintenance, mishandling, misapplication, or used in violation of instructions furnished by us ; damage occurring in shipment or any damage caused by an act of God, such as lightening or line surge. Procedure for Obtaining Warranty Service 1. Contact an authorized distributors or dealer of WIZnet Inc. for obtaining an RMA (Return Merchandise Authorization) request form within the applicable warranty period. 2. Send the products to the distributors or dealers together with the completed RMA request form. All products returned for warranty must be carefully repackaged in the original packing materials. 3. Any service issue, please contact to sales@wiznet.co.kr WIZ125SR User Manual (WIZnet Co., Ltd.) 13