HP Rack Thermal Sensor Monitoring Solution

Similar documents
Copyright 2012 OSIsoft, LLC. 1

Empowering Operations with the PI System

PI Server 2010: Satyam Godasi Sr. Developer. Jay Lakumb Product Manager. Denis Vacher Group Lead. Copyright 2010, OSIsoft LLC. All rights reserved.

Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities

PI SERVER 2012 Do. More. Faster. Now! Copyri g h t 2012 OSIso f t, LLC.

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis

Improved Situational Awareness with OSIsoft PI for the U.S. Nuclear Regulatory Commission (NRC)

PI Batch Users: Batch Migration to PI Event Frames

The Power of Connection

Controlling DC Data Exhaust

New to PI SDK and AF SDK 2010

The Power of Data: Thriving in a World of Change

Direct to Controller Integration Using OPC. Senior SCADA Engineer

Driving Business Value through Enterprise Agreements and Partnering

EQT Midstream Reliability Centered Maintenance Program. Oscar Smith, Senior Principal Engineer, EQT Corporation November 2, 2016

PI Vision: Real-time monitoring and Analysis for the Enterprise

PI Vision Presented by. Chris Nelson, Director of Visualization Products Tom LeBay, Product Manager Jason Golla, Software Development Team Lead

PI Event Frames: Find Your Data by Events

Strategies for managing distributed IT environments. Anne-Marie Gignac Vice President Networking Solutions Schneider Electric

PI Event Frames: Find Your Data by Events

The Automation of Converting SCADA EMS Displays to PI WebParts

TOUR OF THE AF AND PI NOTIFICATIONS DEVELOPER TOOLS THE BUILDERS' CAFÉ WEBINAR SERIES

Batch Users: Batch Migration to Event Frames

PI Vision Rajesh Gomatam Ph.D. Sr. Field Engineer REGIONAL SEMINARS Copyright 2017 OSIsoft, LLC Copyright 2017 OSIsoft, LLC

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Managed Platform for Adaptive Computing mpac

Survey Highlights Need for Better Server Energy Efficiency

OSIsoft Technologies for the Industrial IoT and Industry 4.0

Distribution Fault Locating with PI

Copyri g h t 2012 OSIso f t, LLC. 1

Please give me your feedback

Chevron Brazil Frade Data Architecture Upgrade. Presented by Carlos Britto & Ildemar Ferreira

PI Integrator for Esri ArcGIS: A Journey Through Time and Space

<Insert Picture Here> Managing Oracle Exadata Database Machine with Oracle Enterprise Manager 11g

Transforming Data Protection with HPE: A Unified Backup and Recovery June 16, Copyright 2016 Vivit Worldwide

THE INSIDE-OUT APPROACH. Enabling an Open, Scalable Data Center IoT

USING REST TO ACHIEVE FULL VISIBILITY AND CONTROL ACROSS THE INTERNET OF THINGS: INSIDE THE DATA CENTER ECOSYSTEM WITH TRUE CLOSED-LOOP CONTROL

PI Vision Mike Sloves Group Leader, Software Engineering. Dan Lopez Senior Systems Engineer. 1 November 2017 REGIONAL SEMINARS 2017

Converge. Connect. Protect Protect people and property with Cisco Safety and Security Solutions

REGIONAL SEMINARS 2015

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

USERS CONFERENCE Copyright 2016 OSIsoft, LLC

Copyri g h t 2012 OSIso f t, LLC. 1

Increasing Operational Efficiency with the PI System at SRP USERS GROUP

PI EVENT FRAMES FIND YOUR DATA BY EVENTS BUILDERS' CAFÉ WEBINAR SERIES

OSIsoft Product Roadmap

How to build a PI System in 3.14 Presented by Rhys Kirk, Shell PI Center of Excellence (Wipro)

Monitoring the environment with a Cloud Robotics Service

Improving Blade Economics with Virtualization

The Power of Analysis Framework

Create a Performance Equation Tag (45 min) Learn to use PI SMT (System Manager Tools) 2010 to easily create a performance equation tag.

ExtremeWireless WiNG NX 9500

Cisco Meraki Cisco and/or its affiliates. All rights reserved.

Fixed Assets in the Montreal Metro: a Real- Time Process

FOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance

Kako napraviti Cloud?

HPE Synergy HPE SimpliVity 380

NX 9500 INTEGRATED SERVICES PLATFORM SERIES FOR THE PRIVATE CLOUD

Modelos de Negócio na Era das Clouds. André Rodrigues, Cloud Systems Engineer

What's New with PI Data Access 2010

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Copyri g h t 2013 OSIso f t, LLC. 1

RF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink

Kako optimizovati operativni rad data

System architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,

Modernize Your IT with FlexPod. NetApp & Schneider Electric

Data Center Infrastructure Management (D.C.I.M.)

USERS CONFERENCE Copyright 2016 OSIsoft, LLC

Verasys Enterprise Configuration and User Guide

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

Improving Distribution Reliability with Smart Fault Indicators and the PI System

PI System Crash Course: Get the most out of PI World

Infrastructure. Brett Lobwein Evangelist Converged Datacentre Infrastructure

HP BladeSystem Matrix

USERS CONFERENCE Copyright 2016 OSIsoft, LLC

Tips from the Trenches

The Connected Water Plant. Immediate Value. Long-Term Flexibility.

Introduction Bill Dears, MTES Marketing and Sales Support Manger Manned Neil Roth, CAT MineStar Product Manager Q&A SUBHEADING HERE

PI Vision. Alicia Coppock, Product Manager Rene Thomassen, Center of Excellence Engineer. October 19, 2017

OSIsoft Release Notes

Horizont HPE Synergy. Matt Foley, EMEA Hybrid IT Presales. October Copyright 2015 Hewlett Packard Enterprise Development LP

A HOLISTIC APPROACH DRIVING BETTER OUTCOMES.

SAS SOLUTIONS ONDEMAND

Infrastructure with intelligence

Cisco Advanced Borderless Network Architecture Field Engineer.

Cyber Security Bryan Owen PE Principal Cyber Security Manager October 11, 2016

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

ICT Infrastructure Solutions. Real power for virtualisation

APC by Schneider Electric Elite Data Centre Partner

Data Center Infrastructure Management ( DCiM )

Cornell University Optimizes Energy Efficiency With ifix From GE Digital

Increasing Operational Efficiency with the PI System at SRP

Strategies for a Successful Security and Digital Transformation

Overview. Features FACTORYTALK HISTORIAN SE FACTORYTALK HISTORIAN SE PRODUCT PROFILE INFO ACCESS DRIVES SAVINGS

ADRIAN PAVESI. Sinopec

Features and Benefits: Power IQ DCIM Monitoring Solutions

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

PI System Rollout in Remote Hydroelectric System. Power Generation

Data Center 3.0: Transforming the Data Center via the Network

System architecture. Datacenter Clarity LC provides flexible client-server architectures configured to meet the needs of each organization,

Transcription:

HP Rack Thermal Sensor Monitoring Solution Presented by HP IT Global Data Center Services: Tools & Automation

Agenda Introduction Background: Rack Thermal Sensors Business & Technical Requirements PI System Architecture Monitoring & Visualizations Measuring Success 2

Introduction Members Giao Duong Itoro Meshioye T.J. Eason Erick Levitre Hewlett Packard HP-IT Global Data Center Services: Tools & Automation End-User Organizations: Facilities DC & IT Operations Enterprise Services Environment Six data centers and ten managed compute spaces Monitoring in nearly 2,000 racks with over 7,000 sensors 3

Background Rack Thermal Sensors Benefits Availability Ensure delivery of power/cooling Detection Early warning of potential hot/cold spots Risk Mitigation Facility Outage Events and Unplanned Downtime Analytics Leveraged Technology Legacy Cooling Solution Temperature/Humidity Sensors HP ipdu Door Contact Sensors 4

Business Requirements Objective Gain real-time visibility to environmental information for data centers Drivers Increase awareness of remote environments Reduce risk for unplanned downtime Integrate with formal monitoring and support tools/processes Observe and drive operational efficiencies with early warning and detection 5

Technical Requirements Objective Unify data across both the rack thermal sensor solution and existing legacy cooling solution Drivers Provide reliable, stable, scalable technology Sensors (info, communication) HP ipdu (info, communication) Integrate with high availability architecture Additional pair of interface nodes to existing solution Provide robust analytics and reporting Custom Screens and KPI Calculation 6

PI System Architecture Overview Visualization Layer Users login to Citrix using NT credentials to access PI ProcessBook and PI ActiveView client HP Mobile PI Layer Web Servers allow Mobile PI application to sync with system provide mobile users access PI System Utilizing PI 2010 Components Built with Redundant Architecture PI Server Status Calculation SharePoint Web Server AF Server Interface Layer NGDC Austin NGDC Houston NGDC Atlanta RCS Core DC Total of 36 interface nodes between six data centers and ten managed compute spaces Monitoring over 1million digital and analog points Collecting approx. 1.25 TB of data per year 7

AF Device Modeling Template-Based Assets Area centric Tree Structure 8

AF Device Modeling Template-Based Assets Area centric Tree Structure 9

Rack Thermal Sensor Architecture Implement rack temperature monitoring in the DC using approximately 1,500 RF Code temperature monitoring devices. RF Code Readers PI Users PI Server (Collective) RF Code Zone Manager OSIsoft PI Interface servers PI OPC Interface PI Interface Server Zone Manager PI Interface Server Zone Manager RF Code Reader RF Code Reader 10

Monitoring the Compute Space Monitoring Elements Power Cooling Door Contacts Leveraged OSIsoft Components AF Visualization Custom Calculation Engine PI SDK AF SDK PI API PI Notifications 11

Visualization HP Private Cloud - HP Mobile PI Citrix Server hosts visualization PI ProcessBook PI ActiveView Rack/Row Based Screen Navigation Real Time Data Trends 12

Visualization HP Private Cloud - HP Mobile PI Citrix Server hosts visualization PI Processbook PI Activeview Rack/Row Based Screen Navigation Real Time Data Trends 13

Visualization HP Private Cloud - HP Mobile PI Citrix Server hosts visualization PI Processbook PI Activeview Rack/Row Based Screen Navigation Real Time Data Trends 14

15

Key Performance Indicator Cooling Optimization Index Number A computation that measures the number of racks within the acceptable levels of safe temperature readings. 16

Key Performance Indicator COIN High Percentage of racks that are below 81 F COIN Low Percentage of racks that are above 65 F COIN Index Percentage of racks that are within 65 and 81 degrees F 17

Conclusion/Benefits One single version of the truth Repurpose legacy solution Proactive maintenance Increased detail of environment 18

Contact Info Hewlett-Packard GDCSToolsAutomation@hp.com 19

Brought to you by