IC693 PLC IC693ACC350, IC693ACC340/341

Similar documents
IC693PWR331 High Capacity Power Supply, 24 VDC Input

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

PLC Racks IC697CHS782/783

PACSystems RX7i IC698CHS009/119

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

Junos WebApp Secure 5.0 Hardware Guide

PACSystems RX3i IC695PSA140

PACSystems* RX3i IC695PSA040

PACSystems* RX3i IC695PSA140

Series 3000V Input/Output Board

Installation Instructions

PV Rapid Shutdown device

Model HM-535 Power Supply Installation and Service Instructions

Power Supply and Fan Module Installation

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

Power Supply Installation

5401 and 5402 Digital I/O Modules

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

This Datasheet is for the IC693ACC301. Backup Battery for RAM Memory.

Programmable Controller IC697ACC721/724/744

Model 2380 Rack-Mount Kit

INSTALLATION MANUAL SLI 50 INVERTER

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

Power Supplies IC697PWR724/CE697PWR724

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

24/48/120 VAC Interface Card Instruction Manual

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

Digital ac/dc (24V) Input Module

Power supply CP-C 24/5.0

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

INSTALLATION INSTRUCTIONS

Redundancy unit CP-A RU

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Cisco CRS 16-Slot Chassis Power Systems

MT8050iE series. Installation Instruction (1) (2)

GCI-5K INSTALLATION AND OPERATOR S MANUAL

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

TRC-190 User s Manual

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PanelView Plus/VersaView CE Terminals and Display Modules

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Installing the Cisco AS5400XM Universal Gateway

PS/IO Circuit Board Retrofit

Installation and Maintenance

MC 11 EB-2 Power supply cabinet with external bus, AC version

5504 Thermocouple Analog Input Module

S66 Series Electronic Fan Speed Control

INSTALLATION INSTRUCTIONS

Zebra RW 420 Mobile Battery Eliminator Kits

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Installing the Tracer MP503 Input/Output Module Ordering number: ,

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Replacing the Power Supply

Installation and Wiring

Model 2380 Rack-Mount Kit

Series Specialty PLCs

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

Chameleon Stand-alone

Electrical Demand Specification (Reference SOP: )

OPLC Installation Guide

TRC-190 User s Manual

Site Preparation CHAPTER

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

This Datasheet for the IC693ACC301. Replacement Battery, CPU & PCM (qty 1)

C-POWER AC AUTOMATIC CONTROL

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

PFC Mini TM Power Factor Corrected AC-DC Switchers

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Model 7705 Control Module

E1135C PDU and Pod Upgrade Procedure

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Installation Instructions

Analog Monitor Installation Manual

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Power Supply (48Vdc, 2.5A)

Instruction Sheet Board Style Low Water Cutoff

4170 POS System Installation Guide

Installation Job Aid for VSP 4850GTS

Vision OPLC V TR6/V350-J-TR6

General Specifications. P2-8AD4DA-2 Analog Input/Output

Transcription:

March 29, 2001 IC693 PLC IC693ACC350, IC693ACC340/341 Redundant Power Supply System he IC693 Redundant Power Supply System consists of a Baseplate and an Adapter, described below. Redundant Power Supply (RPS) Baseplate he Redundant Power Supply Baseplate has slots for two standard IC693 power supplies, an attached adapter connection cable that connects to the Power Supply Adapter, status LED lights, a user output, and status relay outputs. here are two models of RPS Baseplates, which are identical except for the length of the adapter connection cable. he IC693ACC340 has a 0.125-meter cable, and the IC693ACC341 has a 0.6-meter cable. Redundant Power Supply Adapter he Redundant Power Supply Adapter plugs into a standard IC693 PLC baseplate s power supply slot. It has a connector that mates to the RPS Baseplate s adapter connection cable. It also contains the backup battery and serial port connector for the PLC (backup battery and serial port connector are not functional on the individual power supplies). B A E R Y PWR OK RUN BA REDUNDAN POWER SUPPLY ADAPER PROGRAMMABLE CONROLLER ACIVE COMM POR IC693ACC350 Redundant Power Supply Adapter REDUNDAN POWER SUPPLY BASEPLAE PS1 ACIVE PS1 PS2 NOE: COMMUNICAIONS PORS AND BAERIES ON PS1 AND PS2 ARE INACIVE. USE HE COMMUNICAIONS POR AND BAERY LOCAED ON HE REDUNDAN POWER SUPPLY ADAPER. PS2 ACIVE Redundant Power Cable OUPU RELAYS 12/ 120/24AC 0.5a REDUNDAN USER SUPPLY 1 2 3 4 5 6 7 PS1 ACIVE PS1 ACIVE COMMON OUPU 0.8A MAX IC693ACC340/341 Redundant Power Supply Baseplate

ERY ERY 2 Redundant Power Supply System Redundant Power Supply Baseplate Mounting Positions he RPS Baseplate can mount in one of three basic positions on an enclosure panel: Above the IC693 PLC baseplate. Use the IC693ACC341 Redundant Baseplate model (with 0.6- meter cable). o the left of the IC693 PLC baseplate. Use the IC693ACC340 Redundant Baseplate model (with 0.125-meter cable). Below the IC693 PLC baseplate. Use the IC693ACC341 Redundant Baseplate model (with 0.6-meter cable). hese three positions are illustrated below. REDUNDAN BASEPLAE BA E RY BA E RY REDUNDAN BASEPLAE IC693 PLC BASEPLAE. BA ERY BA ERY REDUNDAN BASEPLAE BA BA RPS Baseplate Mounting Specifications Mounting Hardware ap four 8#-32 (4mm) holes in the mounting panel using the hole spacing shown in the following figure. Use four #8-32 (4mm) machine screws with flat washers and lock washers in the baseplate mounting holes. Mounting hardware should be a high quality, corrosion-resistant type. As shown in the following figure, two baseplate holes are slotted in order to facilitate a ground wire connection (see Grounding the RPS System on the following page). Ventilation Clearance As shown in the following figure, a minimum clearance allowance (open area) on all sides of the baseplate is required to provide adequate ventilation. Mounting Orientation he baseplate is rated for full load output at 60 C (140 F) when mounted to a vertical surface and with its long dimension oriented horizontally. his orientation provides best ventilation for the power supplies. Mounting the baseplate in a different orientation results in the following load derating: For 25 C (77 F) temperature full load For 60 C (140 F) temperature 50% of full load

Redundant Power Supply System 3 Dimensions are in Inches (Millimeters are in Parentheses) 4.00 (102) 7.87 (200.0) 4.00 (102) Side View with Power Supplies Installed Power Supply 3.54 (90) 5.12 (130) Baseplate 4.00 (102) 8.46 (215.0) *See Note 5.59 (142) CLEARANCE ALLOWANCE FOR COOLING *Note: Recommended Right Side Clearance Allowance for an IC693ACC340 is 2.5 (63) and for an IC693ACC341 is 4.00 (102) Grounding the RPS System he RPS Baseplate should be grounded in the same manner as any IC693 PLC baseplate. Each ground wire should consist of a size 12 AWG or larger wire with a ring terminal crimped to each end. One end of each ground wire should be securely fastened to a conductive surface on the mounting panel (this often requires removing the paint from the panel at the spot where the ground wire is fastened). If all ground wires are connected to one point, ensure that the method (typically using a stud, nuts, and lock washers) is approved by applicable electrical codes. he next figure shows an example ground connection for each of the following components: RPS Baseplate and PLC Baseplate. One end of the ground wire should be mounted under the head of the mounting bolt (with star lock washer and flat washer) in one of the baseplate s slotted mounting holes; the other end should connect to the grounding point on the panel. RPS Adapter Module. he RPS Adapter s ground wire is supplied as part of the RPS cable. See the section IC693ACC350 Redundant Power Supply Adapter for details and a picture of this wire. Connect it to the grounding point on the panel. RPS Baseplate RPS Adapter IC693 10-Slot Baseplate Paint Removed From Panel Around Ground Connection

4 Redundant Power Supply System Installing Power Supplies on the Redundant Power Supply (RPS) Baseplates he two models of Redundant Power Supply Baseplate have mounting slots for two standard IC693 PLC power supplies. he two power supplies may be the same catalog number type or different types. hey install on the RPS baseplates in the same manner as on a standard IC693 PLC baseplate. If you are not familiar with installing IC693 modules, please see the IC693 Hardware and Installation Manual for details. he following figure shows an RPS Baseplate with both power supplies installed. PWR OK RUN BA SANDARD POWER SUPPLY PROGRAMMABLE CONROLLER INPU 100-24AC 50/60HZ9A 125 VDC, 50W PS1 ACIVE REDUNDAN POWER SUPPLY BASEPLAE PS2 NOE: COMMUNICAIONS PORS AND BAERIES ON PS1 AND PS2 ARE INACIVE. USE HE COMMUNICAIONS POR AND BAERY LOCAED ON HE REDUNDAN POWER ADAPER. PS2 ACIVE PWR OK RUN BA SANDARD POWER SUPPLY PROGRAMMABLE CONROLLER INPU 100-24AC 50/60HZ9A 12DC,50W Redundant Power Cable OUPU 0.8AMAX. OUPU RELAYS 12/ 120/24AC 0.5a PS1 ACIVE PS1 ACIVE COMMON REDUNDAN USER SUPPLY OUPU 0.8A MAX OUPU 0.8AMAX. B A E R Y 1 2 3 4 5 6 7 B A E R Y IC693ACC350 Redundant Power Supply (RPS) Adapter he IC693ACC350 RPS Adapter mounts in the same manner as a standard IC693 power supply in the left-most slot of an IC693 baseplate. he RPS Adapter s physical features are shown below. he PLC LED status indicators, RAM memory backup battery, and serial port connector function in the same manner as those of a standard PLC power supply. he serial port connector and backup battery do not work on the power supplies mounted in the RPS Baseplate, and the only LED functional on those power supplies is the PWR LED. he RPS Adapter s connectors mate to those on the RPS Baseplate s power output cable, which splits out to two connectors at the RPS Adapter end. Also, a short ground wire is provided for grounding the RPS Adapter (see the section Grounding the RPS System for details).

Redundant Power Supply System 5 GE Fanuc SERIES 90-30 PWR OK RUN BA SYSEM SAUS INDIC AORS REDUNDAN POWER CABLE ADAPER CONNECORS REDUNDAN POWER SUPPLY ADAPER COMM POR DOOR PROGRAMMABLE GROUND WIRE (#12 AWG, GREEN) ACIVE COMM POR. BAERY COVER LIH IUM BACK-UP BA ER Y B A E R Y RS-485 COMPAIBLE SERIAL POR BAERY CONNECION MOUNING LACH Basic Operation Circuitry in the RPS Baseplate arbitrates (decides which will be on-line) between the two power supplies. Normally, Power Supply 1 (PS1), on the left, is the Primary supply and Power Supply 2 (PS2), on the right, is the Secondary supply, operating in hot standby mode. Each power supply provides a discrete signal, PSOK (1 or 2), to the arbitration circuit that indicates whether the power supply is functioning correctly (logic 1 = OK, logic 0 = invalid). As long as the PSOK1 signal from PS1 stays at logic 1, it will continue to stay on-line, and PS2 will be on hot standby. However, if PS1 fails to maintain proper power output levels, its PSOK1 signal will go to logic 0 and PS2 will quickly be switched on-line. Note that the power supplies are able to hold their outputs for a short time after PSOK goes to logic zero. Later, if PS1 begins functioning correctly again, its PSOK1 signal will go to logic 1, and the arbitration circuit, after a five-second delay, will place PS1 on-line and return PS2 to a hot standby status. he five-second delay helps ensure the stability of PS1. he automatic switching by the arbitration circuit from one supply to the other is designed to be fast enough to provide uninterrupted output power to the PLC. Configuration Configuration requires VersaPro 2.00 or later. he RPS products are not currently supported by any other PLC software. Configuration consists of selecting the IC693ACC350 RPS Adapter module for the power supply slot, and filling in the information on the IC693ACC350 configuration screen. See VersaPro s on-line help for details. Memory Backup Battery he PLC s RAM memory backup battery must be mounted in the RPS Adapter. he standard IC693 memory backup battery, catalog number 44A724534-001 (this is not an orderable number), is used. A kit of two replacement batteries can be ordered by specifying catalog number IC693ACC301. NOE A memory backup battery will not be functional if mounted in either of the RPS Baseplate s power supplies. o protect PLC memory, the backup battery must be mounted in the Redundant Power Supply Adapter.

6 Redundant Power Supply System Serial Communications Port Connector LED Indicator Lights he 15-pin D-shell, serial communications port connector on the RPS Adapter provides standard PLC serial port functionality. he serial communications port connectors are not functional on the RPS Baseplate s power supplies. Power Supply LED Indicator Lights he only LED indicator light that functions on the RPS Baseplate power supplies is the PWR LED, which turns ON to indicate that its DC output is valid. RPS Adapter LED Indicator Lights All of the RPS Adapter s LED indicator lights function as in a normal PLC-mounted power supply. his normal operation is summarized in the following list: PWR ON when its power supply has a correct source of power and is operating properly. his LED will be OFF if there is an input power or power supply fault. OK ON if the PLC is operating correctly, and OFF if a problem is detected by the PLC. RUN ON if the PLC is in the RUN mode, and OFF if the PLC is in the SOP mode. BA the ON state is a warning that the RAM memory backup battery is too low to maintain memory data upon loss of power. Otherwise, this LED remains OFF. RPS Baseplate LED Indicators For normal operation,, PS1 ACIVE, and should be ON, and PS2 ACIVE should be OFF. Note that PS1 ACIVE and PS2 ACIVE should not be ON at the same time since only one power supply can be on-line at a time. LED (Green) ON when PS1 has a correct source of power and is operating properly. his LED will be OFF if there is an input power fault or power supply fault. PS1 ACIVE LED (Green) ON when PS1 is on-line (supplying power to the PLC). OFF when PS1 is off-line (which means that its output is invalid). LED (Green) ON when PS2 has a correct source of power and is operating properly. his LED will be OFF if there is an input power fault or power supply fault. PS2 ACIVE LED (Green) ON when PS2 is on-line (supplying power to the PLC). OFF when PS2 is off-line (in hot standby mode). his LED should only be ON if the PS1 output is invalid.

Redundant Power Supply System 7 RPS Relay/ Output erminal Strip As shown in the following figures, this terminal strip provides connections for Output Relay contacts and Redundant User Power Supply output. he picture on the left shows the terminal strip label on the RPS Baseplate. he picture on the right shows the internal connection diagram for the same terminal strip. OUPU RELAYS 12/ 120/24AC 0.5a PS1 ACIVE REDUNDAN USER SUPPLY 1 2 3 4 5 6 7 PS1 ACIVE COMMON OUPU 0.8A MAX erminal Strip Internal Connections PS1 ACIVE PS2 ACIVE COMMON 1 2 3 4 5 6 7 Output Relay erminal Connections hese four Normally Open output relay contacts reflect the conditions indicated by their corresponding LED indicator lights. If an LED, such as, is ON, its corresponding output contact will be Closed; if an LED is OFF, its corresponding output contact will be Open. hese four output contacts are available on terminals 1 4 of the Output Relays terminal strip. All share a common terminal, labeled COMMON, which is terminal 5 on the Output Relays terminal strip. hese contacts are rated for 12/24 VDC and 120/240 VAC at 0.5A. his terminal strip has box-style terminals that provide protection against accidental touching. Each terminal allows connection of a maximum of two stranded 14 AWG copper wires. Contact (terminal 1) Closed when PS1 has a correct source of power and is operating properly. Open if there is a PS1 input power or power supply fault. PS1 ACIVE Contact (terminal 2) Closed when PS1 is on-line (supplying power to the PLC). Open when PS1 is off-line (which means that it is faulted). Contact (terminal 3) Closed when PS2 has a correct source of power and is operating properly. Open if there is a PS2 input power or power supply fault. PS2 ACIVE Contact (terminal 4) Closed when PS2 is on-line (supplying power to the PLC). Open when PS2 is off-line (in hot standby mode). COMMON (erminal 5) One end of each of the above contacts is tied to this terminal. Redundant User Supply Output hese terminals (terminals 6 and 7) provide an arbitrated, redundant, isolated output for use by the user. Maximum output current available from this supply is 0.83 Amps. Like the other outputs from this system, this output is arbitrated from the redundant power supplies and is designed to maintain uninterrupted power even through the failure of one of the power supplies. his output voltage terminal strip has box-style terminals that provide protection against accidental touching. Each terminal allows connection of a maximum of two stranded 14 AWG copper wires.

8 Redundant Power Supply System System Reliability and esting he following are some possible steps you can take to help ensure the reliability of your RPS System: If applicable safety codes allow, you might consider supplying the two power supply inputs from different power sources. For example, since you can mix power supply models in the RPS Baseplate, one could have a 120 VAC input and the other a 12 or 24 VDC input. Or, both might have 120 VAC inputs but be supplied from two different lines (read WARNING below). Note: Ensure that both power supplies can provide the necessary output current for your application; if a High Capacity power supply is required for your application, both must be High Capacity power supplies. WARNING Use of two different input power sources can create a potential hazard to personnel maintaining the system and may be subject to special electrical codes and regulations. Only qualified personnel who are trained in all applicable electrical safety standards and practices should work on this system. Failure to heed this warning could result in personal injury or death. Use the RPS Baseplate s Output Contacts as inputs to a PLC or other device to monitor the condition of the RPS system. For example, in normal operation, PS1 stays on-line, and PS2 stays in hotstandby mode. But, if PS2 failed while serving in the hot standby mode, it might go unnoticed until a PS1 failure occurred, at which time the system would go down. However, by using the contact, the condition of PS2 can be continually monitored and problems can be reported and corrected to ensure PS2 will be ready if needed. If PS1 failed and PS2 came on-line automatically, the defective condition of PS1 might go unnoticed. hen, if PS2 failed, the system would go down. By using the contact, the condition of PS1 can be continually monitored and problems can be reported and corrected to ensure both power supplies will be ready if needed. If you cannot use the RPS Baseplate s Output Contacts to automatically monitor the system, make frequent visual inspections of the RPS Baseplate s LED status lights to ensure that the system is functioning normally. Since this must be performed with power applied, it should only be done by trained, qualified personnel who know how to SAFELY perform this check with power applied (see previous WARNING note). est the functionality of the RPS System during non-critical times (off-hours, plant shut downs, etc.) by turning off incoming power only to PS1 and observing whether PS2 comes on-line. hen, restore power to PS1 and observe whether it comes back on-line after the five-second delay. If the system fails to perform as expected, it can be repaired before the next period of critical operation begins. Keep spare RPS System parts on hand to help ensure that problems can be corrected promptly. Make a periodic visual inspection of the RPS System. During off-hours, turn off all power to the system and ensure that (1) baseplate ground connections are secure, (2) terminal strip connections are secure, (2) modules and connectors are seated securely, and (3) nothing is hindering the free flow of ventilation air through the power supplies. Environmental and Agency Requirements CE, UL, and CUL listings are pending, but have not been received at the time of this writing. For environmental specifications, please see data sheet GFK-0867.

Redundant Power Supply System 9 Pin-Out for RPS Baseplate Cable Connectors he following pin-out information is included for troubleshooting purposes. his information applies to the connectors on the end of the RPS Baseplate cable. Do not unplug this connector when power is applied. o test the voltages shown below, first turn off power, unplug the connector, then turn on power to the RPS baseplate power supplies. WARNING Only qualified personnel who are trained in all applicable electrical safety standards and practices should work on this system. Failure to heed this warning could result in personal injury or death. he (5 VDC) and P24V (24 VDC Relay Power) voltages should be measured to the terminals. he P24I Isolated 24 VDC terminal should measure 24 VDC with reference to the N24I (Isolated 24 VDC Common) terminal. he PSOK signal should measure 5 VDC with reference to the terminals. he Earth Ground terminal is capacitor-coupled to internal noise suppression components and should not be used as a reference for measuring DC voltages. Connector Locking ab Connector Locking ab P24V (24 VDC Relay Power) No Connection PSOK (5 VDC Power Supply OK Signal) N24I (Isolated 24 Volts Common) Earth Ground P24I (Isolated 24 Volts Positive) NOE: hese views are looking into the end of the cable connectors with the locking tabs on the left side as shown. Specified voltages are nominal values for a properly working system.