VIP-480AL IP One-Way Horn

Similar documents
VIP-148AL IP Talkback Horn

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-812A DUAL NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

V-9964 Digital Feedback Eliminator/Message Stacker

V-9964 Digital Feedback Eliminator/Message Stacker

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

V-9939B MICROPHONE ADAPTER

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

VCMDM MODEM INSTALLATION INSTRUCTIONS

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

V-9908 MESSAGE/PAGE PANEL

TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD

SIP PAGING SERVER MODEL VIP-201A

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

Installation & User Manual

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

Broadband Automatic Disconnect Switch. User Manual

V-9964 Digital Feedback Eliminator/Message Stacker

V-9939C MICROPHONE ADAPTER

V-9937 ONE ZONE PAGE PORT ADAPTER

Global Water Instrumentation, Inc.

TALKBACK INTERCOM SYSTEM V-2928 OPTION BOARD

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

Pit Transition with 24" Fan Installation and Operators Instruction Manual

TDM-150 TIMER DISPLAY

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

VITEK VTD-THD2RFE VTC-THT2RFE VTC-THB2RFE. 2.1 Megapixel Indoor/Outdoor HD-TVI/ AHD/CVI/CVBS IR Cameras

BACnet Router Start-up Guide

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

Proliphix EPA-60 Installation Guide

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

TDM-170 TIMER DISPLAY

Remote Refrigeration Control

NT1B-300 Rack Installation Instructions

Crestron CEN-SW-POE-5 5-Port Power over Ethernet Switch Installation Guide

User Guide. Control Box. RoscoLED TM.

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

Owner s Instruction Manual

Messager USB w/ Night Answer

Digital Audio Extender

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Telephone Line Monitor USER GUIDE

Vocia ELD-1. Operation Manual

USB 2.0 LR Extender. EXT-USB2.0-LR User Manual.

62532 (EN649) Ethernet Adapter

10 Digital Photo Frame Instructional Manual

BACnet Router Start-up Guide

USB 2.0 LR 4-Port Extender

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Continuous Wave Single Frequency Lasers. Concerto Series. 442nm 25, 50, 75 & 100mW

FNet Repeater Installation & Operator s Instruction Manual

10 Slim Digital Photo Frame Instructional Manual

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

Installation and User Guide

AMT-12 AMT-15. Professional Loudspeakers. Installation and Use Manual

User s Guide. POWERVAR Single Phase Power Conditioners

Wall. No opening (Example: LA-030-W)

14 Digital Photo Frame Instructional Manual

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

Sonic Ruptor 400. User Manual

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input

Power over Ethernet POEINJ100 POESPLT100. Instruction Manual. 10/100 POE Power over Ethernet Injector - 48V

EconoComp Product. 6th Edition S I G N E X T R U S I O N S A N D K I T S EFFECTIVE APRIL 1, 2018

Installation & Operation Instructions

HD-SDI Vandal Dome Camera

12 Digital Photo Frame Instructional Manual

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

O3FB68. Flexible Intensifier Technology Bullet IP Camera QUICK INSTALLATION GUIDE

poly-planar Marine Audio System

CAT U S E R M A N U A L

i-series Videoconference Fixture

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Sonorous v2.0. Installation & User Manual

Enterprise Call Manager

iconverter 2-Module Power Chassis

3.5 inch Hard Drive Enclosure. Model #: HDE350U. User s Manual

3.5 inch Hard Drive Enclosure. User s Manual

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Owner s Manual. HDMI Over Cat5 1x2 Extenders. Models: B126-2A1, B126-2A0

FieldServer X-25 Start-Up Guide

PIXIM Micro Dome Camera

USER MANUAL. Kramer Electronics, Ltd. Models:

NEW ERA METER. Installation & Operation Guide NE METER

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Dome Camera. Hardware Manual Z81, Z /01/08

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

INSTALLATION GUIDE ER8400U. 8 Port Wall Mounted IP Video Extender Over UTP With Built-In Gigabit PoE+ Switch and EtherStretch.

AC4G-D User s Manual

CAT5-1600A Extender. EXT-CAT5-1600A User Manual.

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

Transcription:

Issue 1 VIP-480AL IP One-Way Horn Issue 1 INTRODUCTION The VIP-480AL IP One-way Horn provides for one-way communication when used in a Valcom VoIP based intercom/paging system. SPECIFICATIONS Access Methods PBX, FXO Port w/vip-81x POTS telephone set w/vip-81x FXS Port w/vip-82x SIP telephone system Features RJ-45 for network connection LED Status Indicator Network activity LEDs Power over Ethernet (PoE) 802.3af compatible Dimensions/Weight Horn 6.80 H x 8.30 W x 3.30 D (17.27 cm) x (21.08 cm) x (8.38 cm) Weight: 2.10 lbs. (0.95 kg) Network Interface 1.62 H x 5.63 W x 3.45 D (4.11 cm) x (14.30 cm) x (8.73 cm) with brackets 8.22 W (20.87 cm) Weight: 2.10 lbs. (0.95 kg) Nominal Power Requirements Via 802.3af PoE Ethernet Switch: Class 3 Environment Network Interface: Temperature: 0 to +40 C 0 to 85% non-precipitating Humidity: Horn: Suitable for indoor or outdoor installation Packing List Qty Item 1 Network Interface 1 VIP-480AL Horn 1 VSP Document 1 VM-186 RJ-45 Connector 4 Wood Screws 1 C Clamp Precautionary Designations CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. 1 947826

FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense. INSTALLATION Operation: Provides one-way intercom via Network connection to customer telephone system or stand alone telephone set. Interface to customer telephone system can be via SIP registration, FXO port or FXS port (additional equipment required in all cases). Mounting (Network Interface) The Network Interface is designed for wall or table mounting and must be within 100 meters of the network switch. Wall: Using the wood screws and mounting brackets provided, secure the Network Interface to the wall. Mounting (Horn) Flush Mount using Mounting Screws The cardboard packing material in which the horn is shipped also serves as the template for flush mounting. Using the template, mark location of opening and mounting holes on wall. Drill holes appropriate to mounting hardware and cut out the opening. Make appropriate wiring connections and test the speaker for operation. Using appropriate mounting screws (not furnished) drill and mount the flange as shown. UNIVERSAL BRACKET Loosen or separate the universal bracket leaves by loosening or removing the handle and hardware. Using the back leaf as a template, mark the wall through the mounting holes. Drill and mount to the wall using appropriate screws (not furnished) or mount directly to a junction box. Mount the T-bracket to the back of the horn as shown using the (2) ½ inch screws provided. "C" CLAMP FOR "I" BEAM MOUNTING A "C" clamp is provided with the horns to allow mounting to a beam. Place the bolt through the hole in the bottom of the base to secure the "C" clamp to the beam. It is suggested that the horn be mounted to the underside of the "I" beam to provide maximum positioning adjustments. Mount "C" clamp with (2) ½ inch screws provided. Power Connections The only method of powering the Network Interface is via a Power over Ethernet (PoE) switch or power injector meeting the 802.3af specification. Make all required signal connections before connecting to Ethernet switch or power injector meeting the 802.3af specification. Network Connection The Network Interface has one RJ-45 network connector and one RJ-45 horn connector. Use standard Ethernet patch cable to connect the connector of the Network Interface to a PoE Ethernet switch. Signal Connections Audio output connection is made from the Signal Output. The RJ-45 connector on the horn is connected directly to the RJ-45 Signal Output socket on the IP Link. See Figure 1. If additional length is required, any standard T568B extension may be used. See Figure 2. Status Indicator Lights The VIP-480AL has 2 status indication lights on the front panel: Green LED: (Link) Indicates Ethernet connection when illuminated. Yellow LED: (Activity) Indicator flashes to indicate network activity. Setup Information specific to your application will need to be programmed into the VIP-480AL using a computer. The PC used for programming should be connected to the same subnet as the VIP-480AL. Setup will be done using the VIP-102B IP Solutions Setup Tool. Download the latest version of the free IP Solutions Setup Tool from the Valcom web site at www.valcom.com/vipsetuptool. 2 947826

TECHNICAL ASSISTANCE Assistance in troubleshooting is available from the factory. Call (540) 563-2000 and press 1 for Technical Support or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA.Should repairs be necessary, attach a tag to the unit clearly stating your company name, address, phone number, contact person and the nature of the problem. Send the unit to: Valcom, Inc. Repair & Return Dept. 5614 Hollins Road Roanoke, Va. 24019-5056 INTERFACE 350' MAXIMUM DISTANCE SIGNAL OUTPUT CONNECTION FLEXHORN Figure 1 3 947826

INTERFACE 350' MAXIMUM DISTANCE SIGNAL OUTPUT CONNECTION RJ-45 CAT 3/5/6 TYPICAL 568B RJ-45 JACK WHITE/ GREEN WHITE/GREEN ORANGE WHITE/ORANGE WHITE/ RJ45 VM-186 WHITE/ GREEN WHITE/GREEN ORANGE WHITE/ORANGE WHITE/ FLEXHORN Figure 2 VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: 1. inspection by Valcom, Inc. indicates the validity of the claim; 2. the defect is not the result of damage, misuse or negligence after the original shipment; 3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts and labor will be applied to units defaced or physically damaged); 4. freight charges for the return of products to Valcom are prepaid; 5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to additional charges for parts and labor). This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the specific Product covered by the warranty. Disclaimer. Except for the Limited Warranty provided herein, the product is provided as-is without any warranty of any kind whatsoever including, without limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT. This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. Headquarters: Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019-5056 Phone: (540) 563-2000 FAX: (540) 362-9800 4 947826

UNIVERSAL BRACKET SURFACE MOUNTED WITH A UNIVERSAL MOUNTING BRACKET UNIVERSAL BRACKET WITH CLAMP "C" CLAMP FOR "I" BEAM MOUNTING ATTACH CLAMP TO HORN ATTACH FLEXHORN TO BEAM FLUSH MOUNT USING MOUNTING SCREWS: USING THE TEMPLATE, MARK LOCATION OF OPENING AND MOUNTING HOLES ON WALL. DRILL HOLES APPROPRIATE TO MOUNTING HARDWARE AND CUT OUT THE OPENING. HOLDING FLEXHORN FIRMLY AGAINST A FLAT SURFACE, DRILL THROUGH EACH MOUNTING BOSS AS SHOWN. FLUSH MOUNTING IN A STUD WALL INSTALLED WITH MOUNTING SCREWS OR CONSTRUCTION CEMENT. PENDANT MOUNTING WITH OPTIONAL CHAIN AND 'EYE' SCREW OTHER MOUNTING OPTIONS: OPTIONAL V-9805 VANDAL RESISTANT ENCLOSURE 5 947826