VIP 40/45 VIP 400/410

Similar documents
MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

MiCOM P521. Fast Feeder Differential Protection

MiCOM P111. Three phase and earth fault overcurrent relays

MiCOM P521. Fast feeder differential protection

MiCOM P122C Time-Overcurrent Protection

MiCOM P521. Fast Feeder Differential Protection. Protection Relays. MiCOM P521 CUSTOMER BENEFITS

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

NPW800R RETROFITTING. Power and Volatge Protection Relay

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Flair 21D - 22D - 23D - 23DM Self-powered, adjustment-free fault passage indicators

SACE Emax 2 Specification guide

Three phase and earth fault overcurrent relays

Bus Bar Protection Relay B-PRO 4000

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

Protection relay for secondary distribution

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

Earth-fault Relay SPAJ 110 C. Product Guide

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

GRD110 FEATURES APPLICATION

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Feeder protection relay SPAA 121 C. Product Guide

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

MiCOM P12x/y. Three phase and earth fault overcurrent relays

Spectra RMS Circuit Breakers with microentelliguard Trip Units

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

POWER GRID AUTOMATION. Pág.. n. RMU Automation

PowerLogic EM4000 series

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

Feeder Protection Relay REF 610. Product Guide

Section 4 Ground-Fault Protection Devices

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Protection Relays PHASE & RESIDUAL OVERCURRENT

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

MiCOM P111 Numerical three phase and earth fault overcurrent relay description

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Feeder/ Motor Protection Relay VAMP 40

VAMP 11V. Voltage and Frequency Protection Relays. Protection

VAMP 11F. Overcurrent Protection Relays. Protection

GRE120. Motor Protection and Control for MV Systems

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Compact NSX communication

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

GRD130 - FEATURES APPLICATION

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

PowerLogic power-monitoring units. iem3000 Series. Technical data sheet

Products Portfolio. Pole mounted Vacuum Recloser

INSTALLATION & COMMISIONING GUIDE

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

GRE130. Protection and Control for MV Systems

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

LE ELECTRONICS Pvt. Ltd.

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

60103 Circuit Breaker

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Synchro-check relay. Application

Type: P9680 Combined Overcurrent and Earth Fault Relay

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Electrical network protection. Sepam series 20. User s manual 10/2009

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

EDR-3000 Eaton Distribution Relay

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

Grid Automation Controller COM600 How it fits into the Smart Grid?

SIA C. Self-powered overcurrent relay USER MANUAL

Catalog. Arc Guard System TM TVOC-2

COUNTIS ATv2/ATiv2 GB

SM100. On-Line Switchgear Condition Monitoring

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

Digital multimeters DMG

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

PowerLogic High Density Metering System 1-Meter Enclosure

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

Relion 610 series. Feeder Protection REF610 Product Guide

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

Premset kv Compact modular vacuum switchgear with Shielded Solid Insulation System Catalog. Medium Voltage Distribution

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Transcription:

40/45 400/410 Selection guide 01 PM100573 40/45 PM100576 400/410 self-powered integrated protection relay Optimised performance for transformer, incomer, feeder and bus riser protection Complete engineered and pre-tested protection system: dedicated CT and low power actuator () Savings on space and cabling time Optimised for circuit breaker to work together in an optimum manner: Simple protection, easy to implement Perfectly adapted to dedicated applications Schneider Electric functional units including a circuit breaker core unit can be equipped for self powered protection with: a 40, 45, 400 or 410 protection relays, integrated in an optimised functional block to form a protection system dedicated to the application Simple protection, easy to implement High sensitivity sensors to provide the highest level of reliability and sensitivity from 0.2 A to 20 In. Protection functions Transformer protection 40 45 General use protection 400 Phase overcurrent (ANSI 50-51) b b b b Earth fault phase (ANSI 51N) Standard (sum of current method) b b b High sensitivity (earth fault CTs) Thermal overload (ANSI 49) b b Cold load pick-up Measurement functions Phase current b b b b Earth current b b b Phase peak demand current b b b b Load history Cumulative time b b Control and monitoring functions Trip indication Local (with origin of the fault) b b b b 410 Remote (one contact) (3) b b b b 3 output relays b Trip circuit supervision (ANSI 74TC) b b b b Time-tagged events Local on display (5 last trips) b b External tripping input Remote, via communication Overcurrent and breaking profile Number of phase and earth trips b b Serial communication port Modbus RS485 b Power supply Type of supply Self-powered or auxiliary self self self dual (1) Minimum load current to activate the 4A 4A 7A (2) - (1) The protection is self-powered. Auxiliary power is used only for communication and high sensitivity earth fault protection. (2) 14A with 630A CBs. (3) standard on Premset cubicle b b b b 40/45: designed for transformer protection MV/LV transformer protection up to 200A Dedicated protection curve to protect against overloads, short-circuits and earth faults with straight-forward settings Designed up to 200 A circuit breakers to replace fuse-switch solutions 400/410: designed for buildings and MV/LV substation utilities Substation protection (incomers, feeders, bus risers) using 200/630A circuit breaker MV/LV transformer protection instead of 40/45 if more functions are required DT (Definite Time) and IDMT (Inverse Definite Minimum Time) standardized tripping curves Switchgear diagnostics Multi-language display Metering functions 410: ready for Smart grids 410 includes a dual supply (self-powered plus auxiliary) for communication with: Remote communication with DMS and RTUs Remote Alarming Time stamped events recorded Measurement of current, load history, over-current and breaking profile 410 is dedicated for intelligent MV loops with automation: Remote configuration Setting groups selectable according to the configuration of the MV loop Remote asset management Plug and play system with Easergy RTUs (R200) to integrate all the protocols (IEC60870-104, DNP3, IEC61850 ), and remote WEB pages.

40/45 02 40/45 Protection relay PM100573 PM100569 Application Entry level MV/LV transformer protection Dependent-time phase overcurrent tripping curve dedicated to MV/LV transformer protection Definite-time earth fault protection Phase current and peak demand current measurement Main features Schneider Electric recommends circuit breakers for transformer protection instead of fuses. They offer the following advantages: Easy to set Better discrimination with other MV and LV protection devices Improved protection performance for inrush currents, overloads, low magnitude phase faults and earth faults Greater harsh climate withstand Reduced maintenance and spare parts Availability of additional functions such as measurement, diagnostics and remote monitoring. And with the recent development of low cost circuit breakers and self-powered relays, life time costs are now equivalent to those of traditional MV switch fuse solutions. Self-powered operation Energised by the CTs: no auxiliary power needed Complete pre-tested protection system Functional block ready to be integrated Designed to protect transformers Designed up to 200 A circuit breakers to replace fuse-switch solutions Setting is as simple as fuse selection Maximum setting possibilities consistent with circuit breaker characteristics Phase overcurrent protection Tripping curve optimised for MV/LV transformer protection Protection against overloads and secondary and primary short-circuits Only one setting (I>) Discrimination with LV circuit breakers or LV fuses Compliant with TFL (Time Fuse Link) operating criteria t (s) 10000 1000 100 10 1 1 2 3 4 DM100031 Earth fault protection Definite-time tripping curve Settings: Io> (phase current sum method) and to>. Second harmonic restraint element Measurement Load current on each phase Peak demand current Front panel and settings Current measurements displayed on a 4 digit LCD Settings with 3 dials (I>, Io>, to>) protected by a lead-sealable cover Trip indication powered by dedicated integrated battery with reset by pushbutton or automatically 0.1 0.01 I / I> (1) Overload (2) Secondary short circuit (3) Primary short circuit (4) Activation of the discrimination with a Low Voltage circuit-breaker DM100209 Dual core CTs: CUa 40/45 Dual core CTs : for power and measurement Other features Complete pre-tested solution that eliminates complicated CT selection Complies with MV protection relay standard IEC 60255 No PC or specific tool required for setting or commissioning Maximum setting possibilities consistent with circuit breaker features Self-powered by dual core CTs: CUa Environment: -40 C / +70 C Primary injection test A primary injection circuit may be permanently installed (option) through the CTs, inside the cubicle, to test the physical integrity of the complete protection system including the CTs The test is carried out without disconnecting the CTs and the 40/45 displays the injected current during testing If required, a temporary 40/45 test mode can be activated to test the tripping of the circuit breaker by pressing a test pushbutton Test with the Pocket Battery module This accessory can be connected on the 40/45 front plate to energise the relay to carry out a quick test even when the relay is not powered. This test allows testing the circuit breaker.

40/45 03 References 40 100A phase overcurrent protection REL 59910 45 100A phase and earth fault protection REL 59912 40 200A phase overcurrent protection REL 59911 45 200A phase and earth fault protection REL 59913 Characteristics Standards safety IEC 61010 EMC emission IEC 60255-25 EMC immunity IEC 60255-22 climatic IEC 60068-2 mechanical IEC 60255-21 functional IEC 60255-151 Phase Over Current protection (ANSI 50-51) I> Setting range 5A 100A 5A...200A Accuracy 5% T> Tripping curve - dependent time - dedicated to the MV/LV transformer protection - transformer secondary selection: fuse or CB Earth Fault protection (ANSI-51N) Accuracy 8% Io> Range 5A 100A 5A...200A Accuracy 2% To> DT curves 100ms...1s Inrush current delay Start up time Activation current Accuracy 5% on / off Activation time without load, 12A < 80ms according to the fault current (1) Measurement 16A 240A 1kA Minimum load current: 4A (3 phases) 6A (single phase) < 30ms < 20ms < 15ms Phase current Accuracy 2% typical Peak current Accuracy 2% typical CTs Phase CTs type CTs input Continuous 1,3 In Characteristics CB Tripping Frequency Temperature Short time CUa = Dual Core 200A with embedded measurement shunt 25kA / 1s (primary side) mitop eco, 50Hz & 60Hz -40 C +70 C Terminals CTs prefabricated (includes measurement and power supply) prefabricated Trip signaling Mechanical Enclosure front plate IP54, rear part IP30 Mounting in a cut out Dimensions front plate (cut out) = 161 mm x 129 mm depth inside cubicle = 22 mm Control & monitoring function Trip indication Trip circuit supervision (ANSI 74TC) Local with a LED Remote with one contact (located on actuator) (1) If the load current is above the activation current, there is no additional start up time delay and 40,45 will operate according to its normal time settings

400/410 Protection relay 400/410 04 PM100576 PM100580 Applications MV distribution substation incomer, feeder and bus riser protection relay MV/LV transformer protection 410: ready for Smart grids 400 is a self-powered relay energised by the CTs; it does not require an auxiliary power supply to operate 410 is a dual powered relay offering self-powered functions and additional functions powered by an AC or DC auxiliary supply. DM100210 Dual core CTs: CUa/CUb Easy to use 400/410 Dual core CTs : for power and measurement Front panel keypad and display used to set the protections and the operating parameters. displays the network currents and the fault messages. the settings are protected by a password and by a sealable cover. the setting does not require a PC. the LCD is backlit if the 410 auxiliary power is present. 4 fault indicators: OC, EF, thermal, external 3 status led: watch dog, aux power supply, communication Time tagged events records Each time 400, 410 trips the CB, it records the origin of the event, the tripping currents, the date and the time. These data can be read on the front panel or by communication. It provides the operator with an help to analyze a fault on the network. 410 includes a dual supply for communication with Remote communication with DMS and RTUs Remote alarming Time stamped events recorded Measurement of current, load history, over-current and breaking profile 410 is dedicated for intelligent MV loops with automation: Remote configuration Setting groups selectable according to the configuration of the MV loop Remote asset management Plug and play system with Easergy RTUs (R200) to integrate all the protocols (IEC60870-104, DNP3, IEC61850 ), and remote WEB pages. Main features 400: Self-powered protection relay This version is energised by the current transformers (CTs). It does not require an auxiliary power supply to operate. Overcurrent and earth fault protections Thermal overload protection Current measurement functions 410: Dual powered protection relay Offers the same self-powered functions as the 400 In addition, the 410 has an AC or DC auxiliary supply to power certain additional functions that cannot be self-powered: sensitive earth fault protection convenient to all earthing systems external tripping input cold load pick-up 2 setting groups selectable by communication communication (Modbus RS485 port) signalling relays If the auxiliary power fails during an MV short-circuit, the protection functions are maintained operational Other features Designed for circuit breakers 200A and 630A from Schneider Electric Complete pre-tested solution that eliminates complicated CT selection Complies with MV protection relay standard IEC 60255 No PC or specific tool required for setting or commissioning Self-powered by dual core CTs: CUa/CUb Environment: -40 C / +70 C DM100208 Test pocket battery Primary injection test A primary injection circuit may be permanently installed (option) through the CTs, inside the cubicle, to test the physical integrity of the complete protection system including the CTs The test is carried out without disconnecting the CTs and the relay displays the injected current during testing If required, a temporary test mode can be activated to test the tripping of the circuit breaker by pressing a test pushbutton. Injection test case Test with the Pocket Battery module This accessory can be connected on the relay front plate to energise the relay to carry out a quick test even though the relay is not powered. This test allows testing the circuit breaker. Tests of protection system and circuit breaker

400/410 05 References 400 self powered relay - REL 59915 410 A dual powered relay 24...125 VDC & 100...120 VAC REL 59916 E dual powered relay 110...250 VDC & 100...240 VAC REL 59917 Characteristics Standards Safety IEC 61010 EMC emission IEC 60255-25 EMC immunity IEC 60255-22 Aux. power supply IEC 60255-11 Climatic IEC 60068-2 Mechanical IEC 60255-21 Functional IEC 60255-151 Phase overcurent protection (ANSI 50-51) I> and I>> DT curve 0,05...20 In IDMT curves 0,05...2 In Accuracy 5% T> and T>> Tripping curves OFF, DT IEC: SIT/A, VIT/B, LTI/B, EIT/C IEEE: MI, VI, EI, other: RI DT curves 0,05...300s IEC, RI curves TMS: 0,02...2 / step =0,01 IEE curves TD: 0,5..15 / step = 0,1 Accuracy DT 2% IDMT 5% according to IEC 60255-3 I>>> DT curve 0,1...20 In T>>> Curves OFF, DT, INST DT curve Instantaneous 0,05...300s typical = 25ms, max = 40ms condition: 400, 410 is pre energized before the fault Earth Fault Protection (ANSI 50N-51N) Io> DT curve sum 0,025...10 In EF CT 1...24A and 10A...240A ( 410 only) IDMT curves sum 0,025...In EF CT 0,2A...2,4A and 2A...24A ( 410 only) To> Curves OFF, DT IEC: SIT/A, VIT/B, LTI/B, EIT/C IEEE: MI, VI, EI, other: RI DT curves 0,05...300s IEC, RI TMS: 0,02...2 / step =0,01 IEEE curves TD: 0,5..15 / step = 0,1 Io>> DT curve sum 0,1...10 In EF CT To>> Tripping curve OFF, DT Thermal protection (ANSI 59) DT curve 0,05...300s 1A...24A and 10A...240A ( 410 only) Activity Tripping set point Time constant Cold load pickup ON / OFF 0,05 In...1 In 1mn...120 mn Phase overcurrent Action on set point OFF, 150%, 200%, 300%, 400%, 500%, blocking Time delay 1s...240mn Earth fault Action on set point OFF, 150%, 200%, 300%, 400%, 500%, blocking Time delay 1s...60mn

400/410 06 Start up current and time Activation current Minimum load current for 200A CBs : 7A (3 phases), 14A (single phase) Minimum load current for 630A CBs : 14A (3 phases), 28A (single phase) Activation time without load, 0,06 In < 140ms according to the fault current (1) 0,12 In < 75ms 1,2 In < 40ms 5 In < 30ms 10 In < 20ms Measurement Phase and earth current Accuracy 1% typical Peak current Accuracy 1% typical LCD activation 10A Load history Cumulative time The cumulative time (hours) is displayed in 3 levels: For 200A CBs: <100A, <200A, > 200A For 630A CBs: <300A, <600A, > 600A CTs Phase CTs type 200 A CUa = Dual Core 200A with embedded measurement shunt 630 A CUb = Dual Core 630A with embedded measurement shunt Earth fault CTs type (2) ratio = 470:1 CSH 120, CSH200, GO110, CSHU = embedded EF CT 470/1 Thermal withstand - CTs input Continuous 1,3 In Short time 25kA / 2s (primary side) Input / output Ext tripping input x 1 - ext contact dry contact CB Tripping mitop eco Auxiliary supply (2) 410 A 24...125VDC, 100...120VAC +/-20% 410 E 110...250VDC, 100...240VAC +/-20% Signaling relays (2) x 3 250DC+20%, 240AC+20% AC: 5A/240V pf = 0,3 DC: 5A/24V, 1/48V, 0,1A/220V, L/R=40ms Characteristics Frequency 50Hz & 60Hz Temperature -40 C +70 C Battery Type 1/2 AA LI 3,6V Life duration 10 years Terminals CTs prefabricated (includes measurement and power supply) Earth Fault screw type prefabricated I/O, aux power screw type Communication RJ45 - Modbus Mechanical Enclosure front plate IP54, rear part IP30 Mounting in a cut out Dimensions front plate (cut out) = 161 mm x 129 mm depth inside cubicle = 98 mm Weight 800 g Control & monitoring function Languages & display English UK, english US, spanish, french, chinese, italian, german, turk, portugues, Trip indication Local with a LED Remote with one contact (located on actuator) 3 output relays : 01 = phase fault (I>, I>>, I>>>), 02=earth fault (To>, Io>>), 03= termal overload alarm Events External trip input Overcurent & breaking profile Serial communication port Trip circuit supervision (ANSI 74TC) Time-tagged events: Local on display (5 last trips) Remote, via communication To connect an external relays (pressure, temperature ) The number of trips is displayed in a 4 levels: for 200A CBs : <200A, <2kA, <8kA, >8kA for 630A CBs : <630A, <10kA, <20kA, >20kA Modbus file description IEC61850 (1) If the load current is above the activation current, there is no additional start up time delay and 400 will operate according to its normal time settings. 410 is not subject to additional start up time because of its auxiliary power supply. (2) 410 only

Sensors and connections Sensors and connections 07 PE50032 High sensitivity sensors integrated protection system The integrated protection system is composed of sensors, a processing unit and an actuator, designed together to provide the highest level of reliability and sensitivity from 0,2A to 20 In for 400/410 and 5A to 20 In for 40/45 CSH 120/200 Sensors The sensors are made up of one block of phase CTs with rated insulation voltages of 0.72 kv / 3 kv - 1mn, providing both measurement and power outputs. PM100619 The measurement sensor is based on Low Power Current Transformer (LPCT) technology, ensuring excellent accuracy : - 5P30 for protection - class 1 for measurement. The power supply sensor ensures calibrated self-powering of the relay even for currents of just a few Amperes: e.g. 7A is sufficient for operation of the 400 with a 200A Circuit Breaker, up to its saturation level e.g. 4A is for operation of the 40 up to its saturation level CSHU The protection sensors are located under the core unit, the earth fault sensors around the bushings or on the cables. The connection between all these elements, sensors and relay, is prefabricated and protected against external aggression, providing a higher level of reliability. PM100616 Actuators The actuator is a dedicated low power tripping coil () specifically designed to operate with the sensors and the processing unit with a minimum energy. The integrity of the circuit is continuously supervised (Trip Circuit Supervision function). CUa CUb Connection The series is an integrated protection system: Dedicated sensors located under the core unit provide protection and measurement outputs Optional additional earth fault sensors are available Actuators are low power tripping coils (). Connection diagrams 40/45 and 400 DM100029 Injection test L1 L2 DM100030 410 Injection test L3 L1 L2 L3 Test pocket battery Communication RS485 Ext. trip OC EF Thermal AC/DC Test pocket supply battery

Sensors and connections 08 Connection 40/45 1 4 digits LCD display 2 Phase protection I> setting permanent display of the 3 phase currents in A automatic scrolling display PM100569 1 14 8 7 6 PM100575 10 12 13 3 Earth fault Io> and To> setting (1) 4 Sealing cover protects the settings and the trip test key 5 Trip test key to test the circuit breaker and the protection relay 2 3 5 9 11 6 Test/reset key to acknowledge the fault indication 7 Imax key to display the peak demand current 3 phases automatic scrolling display 4 8 Trip indicator flashing red light powered by the embedded battery 9 Product reference commercial reference, logistic reference, production date code 10, 11 CTs connection measurement sensors connection power supply sensors connection PM100573 PM100583 12 connection 13 Battery used to energize the trip indicator 139 mm 5.48 in 14 failure indicator watchdog checking system (1) Only on 45 179 mm 7.05 in 22 mm 0.87 in 15 mm 0.59 in Connection 400/410 1 LCD display graphic display 2 Status LED auxiliairy power (410) failure indicator (watchdog) COM (410) 3 Setting keys confirm entry key, abort entry key, setting keys 4 sealing cover - protects the settings and parameters 5 Selection keys - to navigate in the menus 6 Reset key - to acknowledge the fault indication 7 Menu key to select menus to start from the embedded battery in order to enter settings 8 Fault indicators flashing red light powered by the embedded battery 9 Product reference commercial reference, logistic reference, production date code 10, 11 CTs connection measurement sensors connection power supply sensors connection 12 mitop connection 13 battery used to energize the trip indicator to set protections and parameters during commissionning without any external supply 14 Connector (410) 15 Connector (410) 16 Communication connector (410) Schneider Electric Industries SAS 35, rue Joseph Monier CS 30323 F - 92506 Rueil Malmaison Cedex (France) Tél. : +33 (0)1 41 29 70 00 RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com zero sequence sensor connection external tripping input connection auxiliary power supply connection signaling output (x3) connection RS485 modbus connection PM100580 PM100576 As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Design: Schneider Electric Industries SAS Photos: Schneider Electric Industries SAS Publishing: Altavia Connexion - Made in France This document has been printed on recycled paper NRJED111125EN 03-2012 7 4 3 1 5 179 mm 7.05 in 2 6 8 13 9 PM100581 139 mm 5.48 in 11 10 PM100578 12 15 14 9 98 mm 3.86 in 16 15 mm 0.59 in ARTXXXXX Schneider Electric Industries SAS - Tous droits réservés