LUNA LUNA 120 top2 D GB F I E P NL PL. Installation and operating instructions Twilight switch. LUNA 120 top2

Similar documents
LUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch

TR TR 608 top TR 609 top D GB F I E NL. Installation and operating instructions Digital time switch. TR 609 top2

TR TR 610 top2 G

Plug-in screwless terminal NC contact. OBELISK top2 memory card ( )

1. Basic safety information 4 2. Proper use 4

1. Basic safety information 3 2. Proper use 3

click DuoFix screwless Plug-in screwless terminal NC contact Test tap

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

1. Basic safety information 4 2. Proper use 4

1. Basic safety information 4 2. Proper use 4

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Operating voltage Maximum

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Data sheet. Function description. Benefits

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

DALI Professional Controller-4. Control unit Operating instructions

Data sheet no Data sheet General data sheet Status: 00 hst/ml Distribution: Valid from: Release: Device no.:

Product and functional description

Product and functional description

Product and function description

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

PHARAO. Compact controllers for installation and automation technology

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101

Demonstration Case BENNING DB 1

Operating instructions. Standstill monitor A / / 2011

pole 17.5 mm wide. electronic ballast W

1 pole 17.5 mm wide 2,000 2, ,000 1,000 halogen W DC / / / / 30

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Product and functional description

Figure 1: Device components

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Operating instructions. Speed monitor D / / 2014

LAN- MODULE NOW AVAILABLE SOON. smart link MOBILE APP PROGRAMMING MODULAR SYSTEM GATEWAY TO LAN NETWORK EXTENDABLE UP TO 8 CHANNELS

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Digital time switch SHT-1/2 - two channel - with daily and weekly program. Operating manual. Content. 1. Before you start Features of the device

Operating Instructions VEGAMET 381

ISOMETER isoev425 with coupling device AGH420

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

PSR UC/ESAM4/3X1/1X2/B

Operating instructions. Switching amplifier DN0210 DN / / 2015

The LED display (1) turns green when the load is switched on.

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Push Button Interface UP 220D31

Product and functional description

Electronic Temperature Controller. Instruction Manual Version

Product and functional description

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Digital time switch - one channel - with daily and weekly program. Operating manual. Content. 1. Before you start Features of the device.

OPERATING INSTRUCTIONS

PSR DC/ESP4/2X1/1X2

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1

Safety controller unit B1 /

SEH62.1. Digital Time Switch

Operating Instructions. DALI-Gateway

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:

is then retained absolutely without interruption.

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Transportation Solutions. Audio Signal Transducer

ISOMETER isopv with coupling device AGH-PV

Differential Liquid/Gas Pressure Transmitter

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

7 Day Digital Programmer 1 Channel Surface Mount

Description TR D

PHOENIX CONTACT - 01/2007

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

OT EASY 60 II. LED control unit Operating instructions


MSR178DP. Description. Features. Specifications

PHOENIX CONTACT - 07/2006

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

SOLARIMMERSION IV Advanced Installation Manual v1.9

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

VIBRATION MONITOR CX-RLY

Electronic time relays ATI, BTI, SDT and MTI

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Power supply module, bus connection module

ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL

CMC III Universal Sensor

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

7 Day Digital Programmer 2 Channel Surface Mount

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Transcription:

2 309 272 01 LUNA LUNA 120 top2 GB 120 0 100 120 0 200 0 6 12 18 24 Installation and operating instructions Twilight switch MENU 1 OK 2 Lux 2000 LUNA 120 top2 D GB F I E P NL PL 2600 W 16A-10AX 250V~ 0,5mm - 2,5mm 2 1 2 3 8mm 230-240V~ 220-240V~ 50-60Hz R10a Ò30T LUNA 120 top2 Correct connection required for smooth zero crossing switch operation (see connection diagram)!

Contents Basic safety instructions 3 Display and keys/operating instructions 4 Overview of menu selection 5 Connection/installation 6 Connection/installation of light sensor 7 Initial start-up 8 Set lux values 9 Menu item LIGHT Set delay 10 Menu item PROGRAM Set switching time 11 Menu item MANUAL Manual and permanent switching 12 Menu item OPTIONS Enter PIN code 13 OBELISK top2 memory card 13 Technical data 14 Service address/hotline 14 2

Basic advice GB WARNING Danger of death through electric shock or fire! Installation should only be carried out by a professional electrician! The device is designed for installation on DIN top hat rails (in accordance with EN 50022) Power reserve (10 years) is reduced if memory card is inserted (in battery operation) OBELISK top2 memory card: Avoid mechanical stress or contamination caused by other storage/ Transport vermeiden (available if required) Designated use The digital twilight switch is used for lighting equipment (streets), external stairways, display windows, entrances etc. Only use in enclosed dry spaces (equipment); sensor is installed in the open-air Disposal Dispose of equipment in an environmentally-friendly manner 3

Screen display and keys Operating instructions Programmed ON switching times Date display Channel status ON OFF 0 6 12 18 24 Time display Days of the week from 1 to 7 1. Read text line Flashing text/symbol represents query 2. Make a decision Display of active keys withrelevant function MENU OK YES Confirmation NO Alter/ change Activate screen Open menu Cancel menu ESC (leave menu) Selection options are displayed Store selection Confirm selection Press OK Press 4

Overview of menu selection MENU GB 19 10 08 OFF 9:40 46 LIGHT PROGRAM TIME/DATE MANUAL OPTIONS END ON DELAY FREE 56 TIME PERMANENT ON OPERATING HOURS METER ON DELAY NEW DATE PERMANENT OFF LCD ILLUMINATION END VIEW SUMMER-- WINTER MANUAL ON LANGUAGE CHANGE WEEKDAY TIMER PIN DELETE DATE FORMAT HOLIDAY FACTORY- SETTINGS END DATEFORMAT END INFO END END 5

Connection/installation Connect cable WARNING Warning, danger of death through electric shock! Must be installed by a professional electrician! Connect power source! Cover or shield any adjacent live components live components. Ensure device cannot be switched on! Check power supply is disconnected! Earth and bypass! Strip cable by 8 mm (max. 9). Insert cable at 45 in the open terminal (2 cables per terminal position possible). Press screwdriver downwards to open spring screwless terminal. Spring screwless terminal Spring screwless terminal NC contact Test tap 45 cable 6

Connection/installation of light sensor Take length of connection cable into account max. 100 m 2 x 1,5 mm 2, max. 50 m 2 x 0,75 mm 2 Avoid running sensor wiring wiring parallel to mains power cables. 0,5 2,5 mm 2, strip cable by 10 mm (max. 11 mm). GB 50 m 907 0 011 907 0 416 Installing light sensor Mounting light sensor 7

Initial start-up Set language, date, time as well as summer/ winter time DATE FORMAT YEAR GERMAN KEEP PROGRAM Press required key and display follows on screen (see fig). MONTH DAY TIME FORMAT HOUR MINUTE SUMMER- WINTER EUROPE or SUMMER- WINTER GB/ IRL/P SUMMER-WINTER FIN/ GR/TR ok SUMMER- WINTER CDN SUMMER- WINTER USA 07 28 02 08 ON 9:40 46 SUMMER- WINTER IRAN SUMMER-WINTER FREE RULE SUMMER-WINTER FIXED DATE 8 WITHOUT SUMMER- WINTER

Set lux values The twilight switch with external light sensor controls lighting equipment for streets, stairways, enrances etc. GB Set desired range from I-V with a screw tab a screwdriver on the potentiometer setting (see fig). The red LED lights up as soon as the set Lux value falls below the ambient brightness level. 0 6 12 18 24 MENU OK 1 2 Lux 2000 LUNA 120 top2 Brightness values Daylight (bright) 80,000 lx Office accommodation 500 lx Hallways and stairs 100 150 lx Street lighting 15 lx Full moon ca. 0.3 lx Potentiometer for setting brightness: 2 2000 lx Red LED for the instantaneous display of switching status 9

Set delay An on/off delay of 1 minute is preset to avoid faulty operation caused by lightning, car headlights etc. LIGHT When the delay ends the channel status will flash ON/OFF. ON DELAY MINUTE or ON DELAY MINUTE Press MENU (see fig.). SECONDS SECONDS 10

Set switching time (e.g. with a night switch off at theweekend 23:00 05:00 Uhr) Press MENU (see fig.). PROGRAM ok NEW VIEW ok NIGHTSWITCH GB There are 56 available memory cells. CHANGE DELETE END same switching time for several days = block SAVE COPY PLUS TUESDAY HOUR MINUTE MONDAY LASTS UNTIL SAVE Switching time for one day 11

Manual and permanent switching Manual and permanent switching can be set using the menu in MANUAL or (in the automatic screen) by key combination (see fig). Manual control Reversing the channel status to the next automatic or programmed switching. Channel C1 Activate manual switching Briefly press both keys simultaneously. Permanent switching As long as a permanent switching (on or off) is activated, the programmed switching times are ineffective. Activate permanent switching Simultaneously press both keys for 2 seconds. Cancelling manual/permanent switching Press both keys simultaneously. 12

Enter PIN code The PIN-Code is set via the menu in OPTIONS (see picture). If you have forgotten the PIN please call the Theben Hotline. OPTIONS ok OPERATING HOURS METER LCD ILLUMINATION OBELISK top2 memory card (available if required) Using memory card Insert memory card in the timer. Request savedswitch timings, read to/from the timer or start Obelisk program. Remove OBELISK top2 memory card (no. 907 0 404) after programming etc. and store in cover. GB LANGUAGE PIN ok WITHOUT PIN FACTORYSETTINGS INFO WITH PIN ok ok CURRENT PIN NEW PIN 00 00 13

Technical data Nominal voltage: 220 240 V~, +10 %/-15 % Frequency: 50 60 Hz Brightness range: 2 2.000 lx On/off switch delay: 0 59 min Power consumption: type 3 VA Switching output: phase-independent (zero-crossover switching) Contact: two way switch Contact material: AgSnO 2 Switching capacity: 16 A/250 V~ cos ϕ = 1 10 A/250 V~ cos ϕ = 0,6 Fluorescent lamps: 10 AX Switching capacity min.: 10 ma/230 V AC 100 ma/12 V AC/DC Glow lamp load: 2600 W Halogen lamp load: 2600 W Fluorescent lamps (VVG low-loss series devices): uncorrected: 2300 VA series-corrected: 2300 VA parallel-corrected: 800 VA (80µF) Lead-lag circuit (duo): 2300 VA Fluorescent lamps (EVG Electronic series devices): 650 VA Mercury and sodium vapour lamps: parallel-corrected: 800 VA (80µF) 14 Compact fluorescent tubes (EVG): 22x7 W, 18x11 W, 16x15 W, 16x20 W, 14x23 W Permissible ambient temperature: 30 C... +55 C (device) 40 C... +70 C (sensor) Protection class: II (light sensors III) in accordance with EN Protection rating: 60730-1 if correctly IP 20, IP 55 (Mounted light sensor), IP 65 (Installation light sensor) in accordance with EN 60529 Service address/hotline Service address Theben AG Hohenbergstr. 32 72401 Haigerloch GERMANY Telephone +49 (0) 74 74 6 92 0 Fax: +49 (0) 74 74 6 92 150 Hotline Telephone +49 (0) 74 74 6 92 369 Fax +49 (0) 74 74 6 92 207 hotline@theben.de Addresses, telephone numbers etc. www.theben.de