TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

Similar documents
LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

VANE ANEMOMETER HUMIDITY/TEMP.

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

AC/DC MAGNETIC METER

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

TU-2016 TURBIDITY METER

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

HOT WIRE ANEMOMETER. Model : 204HA

OPERATION MANUAL. SD card real time Data Recorder SOLAR POWER METER. Model : SPM-1116SD

VIBRATION METER Model : VB-8213

Laser, PHOTO TACHOMETER RS

TORQUE METER Model : TQ-8800

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

UV LIGHT METER UVC-254

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

600 g x 0.02 g DIGITAL BALANCE

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

LIGHT METER OPERATION MANUAL. Model : LM-81LX

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

Torque Meter. Instruction Manual

DIGITAL ANEMOMETER Model : AM-4203

SD card real time datalogger, RS232/USB Frequency weighting and Time weighting meet IEC class 2, Personal sound exposure meet IEC 61252

Manual Digital Thermometer PCE-T 390

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Pocket type SOUND LEVEL METER Model : SL-4030

Pen type, with separate electrode PH METER Model : PH-220 OPERATION MANUAL

OPERATION MANUAL. SD card real time datalogger HEAT INDEX WBGT METER. Model : WBGT-2010SD

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

PRESSURE METER OPERATION MANUAL. Model : PS-9302

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

Torque Meter. Instruction Manual

VACUUM METER Model : VC-9200

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

4 in 1 Anemometer, Humidity Light Meter, Thermometer

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3

OPERATION MANUAL. SD card real time data logger DISSOLVED OXYGEN METER. Model : DO-5512SD

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

Clamp meter with Data recorder SERIES set

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER.

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

Model LM-81LX. Instruction Manual. Light Meter. reedinstruments. REED Instruments

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Instruction Manual Force Gauge, Kg

Anemometer, Hygrometer Light Meter, Thermometer

TA 888 Hot Wire Anemometer

User's Guide. Datalogging Hygro-Thermometer Model SD500

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

4-Channel Vibration Datalogger

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

Datalogging Hygro-Thermometer

Datalogging Hygro-Thermometer

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

TTC Series Torque Tool Tester Operation Manual

User's Guide. 3 Channel Datalogging Thermometer Model SD200

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments

User's Manual. VA893 Thermo Anemometer

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

Heavy Duty Differential Pressure Manometer. Model User's Guide

Light Meter with Bar Graph

3 Channel Datalogging Thermometer

RH/Temperature SD Card Datalogger. Instruction Manual

Visible Light SD Card Datalogger

Light Meter (Foot Candles)

Vibration Meter SD Card real-time datalogger

Barometric Pressure / Humidity and Temperature Datalogger

FG-7000L Digital Force Gauge Operation Manual

Transcription:

1000 Kgf-cm, heavy duty, professional TORQUE WRENCH Model : TQ-8803 Your purchase of this 1000 Kgf-cm Torque Wrench marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure developed. Please read the following instructions carefully and always keep this manual within easy reach. OPERATION MANUAL

TABLE OF CONTENTS 1. FEATURES...1 2. SPECIFICATIONS... 2 2-1 General Specifications... 2 2-2 Electrical Specifications... 3 3. FRONT PANEL DESCRIPTION...4 3-1 Display...4 3-2 Power button...4 3-3 LCD backlight button...4 3-4 Unit button...4 3-5 Button... 4 3-6 Button... 4 3-7 Handle...4 3-8 Torque force direction switch...4 3-9 Battery Compartment/Cover...4 3-10 Screws for battery cover...4 3-11 Square drive...4 3-12 Beeper... 4 4. MEASURING PROCEDURE...5 4-1 Measurement... 5 4-2 Auto data hold...6 4-3 LCD backlight ON/OFF...6 4-4 Alarm setting...6 4-5 Auto power off... 7 5. BATTERY REPLACEMENT...7

1. FEATURES * Professional and Heavy duty torque wrench. * Range : 1000 Kgf-cm, 868 lbf-in, 72.3 lbf-ft, 9807 N-cm, 98.1 N-m. * Unit : Kgf-cm, Lbf-in, lbf-ft, N-cm, N-m. * Auto data hold function to freeze the last measurement reading. * Alarm value setting with beeper sound. * Size of square drive : 3/8 inch square ( 9.52 mm square ). * LCD display with backlight, easy readout. * Auto shut off circuit to save battery life, * Microcomputer circuit, high performance. * Metallic heavy duty & compact housing case. * Power supply : DC 1.5V battery ( UM-4, AAA ) X 4 PCs. 2. SPECIFICATIONS 2-1 General Specifications Display 57 mm x 25 mm LCD display. Measurement Torque value, function Auto data hold, Alarm beeper setting. Measurement kgf-cm, lbf-inch, lbf-feet, Newton-cm, unit Newton-meter. * kgf : Kg-force, lbf : pound-force Function 5 buttons : buttons Power button Backlight button Unit button button ( for alarm setting ) button ( for alarm setting ) 1

Sensor Exclusive torque sensor. Circuit Exclusive microcomputer LSI circuit. Data hold Freeze the last reading automatically. Alarm setting It can set the alarm force value, when measuring value reach the alarm value the beeper will sound, the LCD backlight will flash too. Zero adjust Automatic zero adjustment. Size of 3/8 inch square ( 9.52 mm square ). square drive Power off Auto shut off, saves battery life, or manual off by push button. Power supply Alkaline or heavy duty type DC 1.5 V battery ( UM-4, AAA ) x 4 PCs. Power Approx. DC 5 ma ( baklight off ). consumption Approx. DC 13 ma ( baklight on ). Weight 1050 g ( 2.3 LB ). Dimension 450 x 55 x 37 mm ( 12.2 x 2.0 x1.8 inch ). Accessories Instruction manual... 1 PC. included Hard carrying case... 1 PC. 2

2-2 Electrical Specifications ( 23 5 ) Display Max. Range Min. Range Resolution Unit kgf-cm 1000 kgf-cm 3 kgf-cm 1 kgf-cm lbf-in 868 lbf-in 2 lbf-in 1 lbf-in lbf-ft 72.3 lbf-ft 0.2 lbf-ft 0.1 lbf-ft N-m 98.1 N-m 0.2 N-m 0.1 N-cm N-cm 9807 N-cm 20 N-cm 2 N-cm * kgf : Kg-force, lbf : pound-force, N = Newton * in = inch, ft = feet, m = meter, cm = centimeter Display Accuracy Unit kgf-cm ± 2 % F.S. ( full scale ) lbf-in @ From 20% to 100 % of full scale. lbf-ft ± ( 2 % reading + 5 d ). @ 5% to 19 % of full scale. N-cm N-m @ Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only. 3

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Power button 3-3 LCD backlight button 3-4 Unit button 3-5 Button 3-6 Button 3-7 Handle 3-8 Torque force direction switch 3-9 Battery Compartment/Cover 3-10 Screws for battery cover 3-11 Square drive 3-12 Beeper 4

4. MEASURING PROCEDURE 4-1 Measurement 1)Power on the meter by pressing the " Power Button " ( 3-2, Fig. 1 ) once, the Display will show zero value and ready for the measurement. * After power on, if press the " Power Button " ( 3-2, Fig. 1 ) once again, the meter will be off. * The minimum measurement value is 50 kgf-cm (43 lbf-in/3.6 lbf-ft/4.9 N-m/490 N-cm ), if the measurement value less than 50 kgf-cm, the Display will show " 0 " value. 2)Unit Button After power on, push the " Unit button " ( 3-4, Fig. 1 ) once in sequence to select the measurement unit : kgf-cm, lbf-in, lbf-ft, N-cm, N-m. * After select the desired unit, if power off then power on again, the existing sleet unit will save into the memory circuit with default. 3)Set the Torque force direction by slide the " Torque force direction switch " ( 3-8, Fig. 1 ). * Set the direction switch to the left, will make the clockwise direction for the torque force measurement. * Set the direction switch to the right, will make the counterclockwise direction for the torque force measurement. 5

4)Connect the " Square Drive " ( 3-11, Fig, 1 ) to the " Torque adapter " ( optional ) or the measured " Measurement Installation " that intend to measure the torque value. Use the hand to hold the " Handle " ( 3-7, Fig. 1 ) firmly and rotate the Handle, the Display will show the measurement torque value. 4-2 Auto data hold During the measurement, upon Display show the measurement torque value, if release the handle, the last measurement value will freeze on the Display within 10 seconds approximately at the same time the Display will show the " HOLD " indicator. * During execute the " Auto data hold " function, if make new measurement again, the " Hold function " will be disappeared and return to normal measuring screen. 4-3 LCD backlight ON/OFF After power on the meter, if press the " LCD backlight button " ( 3-3, Fig. 1 ) once will turn on the LCD backlight, if press the " LCD backlight button " once again will turn off the LCD backlight. 4-4 Alarm setting 1) After power on, it press the " Button or Button " ( 3-5, 3-6, Fig. 1 ) once or continuously will set the Alarm setting value ". 2)a. The setting Alarm value will save into the memory circuit with default. b. The " Beeper " ( 3-12, Fig. 1 ) will sound slowly if the the measuring value reach the 90% Alarm setting value. c. The " Beeper " ( 3-12, Fig. 1 ) will sound quickly if the the measuring value reach the Alarm setting value. 6

4)The LCD backlight will flash for warning if the measuring value reach the Alarm setting value. For example : * If the Alarm setting value is 500 kgf-cm, the " Beeper " will sound slowly when the measuring value reach to 450 kgf-cm, the " Beeper " will sound quickly when the measuring value reach to 500 kgf-cm. * When the measuring value reach to 500 kgf-cm, the LCD backlight will flash for warning too. 4-5 Auto power off After power on, if do not make any further operation ( not change the Display value or not press any buttons ), then within 3 minutes the meter will power off automatically to save the battery power energy. 5. BATTERY REPLACEMENT 1)When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2)Loose the " Screw of the battery cover " ( 3-10, Fig. 1 ) and take away the " Battery Cover " ( 3-9, Fig. 1 ) from the instrument and remove the battery. 3)Replace with DC 1.5 V battery ( UM4/AAA, Alkaline/heavy duty ) x 4 PCs, and reinstate the cover. 4) Make sure the battery cover is secured after changing the battery. 7 1304-TQ8803

0911-TQ8803