Hitachi s Latest Supervisory, Operation and Control System for Thermal Power Station

Similar documents
High-Reliability, Next-Generation Supervisory and Control System for Power Stations

High-performance Digital Protection and Control Unit for Distribution Substations

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS

Automation System Solutions

Design of Coal Mine Power Supply Monitoring System

Shabnam Rukhsar Electrical Engineering Department, Anjuman College of Engineering and Technology.India

AUTOMATION OF POWER DISTRIBUTION USING SCADA

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Transmission Infrastructure Investment & Development in Vietnam

Protection and Control System Using Open Network Architecture for Power Systems

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

On Design and Implementation of Locomotive Video Monitoring System. Haifeng Yuan, Jie Peng

Hitachi Integrated Instrumentation System

Compact Controller M<CC-M>

Prepared By Turki AL-Mugaiteeb Control System Engineer EASTEREN PEROCHEMICAL COMPANY SHARQ 3 rd Expansion Project (OLEFIN)

UNITROL 5000 Excitation Systems for Medium and Large Synchronous Machines

INTELLIGENT SCADA FOR LOAD CONTROL

Troubleshooting PLCs & SCADA Systems

B5-111 APPLICATION OF INTRANET TECHNOLOGIES FOR POWER SYSTEM PROTECTION

Common Technical Issue On I&C

expertise beyond controls Reliant Series 5

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

SCADA Software. 3.1 SCADA communication architectures SCADA system

Steam Boiler Automation Using Programmable Logic Controller

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

DIMINISHING THE REQUIREMENT OF POWER USING PLC AND SCADA SYSTEMS IN POWER GRID SYSTEM

Practical Programmable Logic Controllers (PLCs) for Automation and Process Control. Contents

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

2009 E09PS E09PS E09PS E09PS E09PS E09PS38 IEEE 2009 E09PS39 E09PS40 E09PS41 E09PS42 E09PS43 IEEE 2008 E09PS44

Intelligent Remote Terminal Unit (irtu) in the IoT Era

Digital Substation Overview of Technology, Industry

Compact universal controllers

The ACS-3000 Advanced Controller

PATENT PENDING RABBIT EARS THERMOELECTRIC GENERATOR

UniGear type ZS1. SSC (Switchgear System Connectivity)

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Remote Terminal Unit ER1000 APPLICATION FEATURES

Chapter 2 State Estimation and Visualization

Remote monitoring and display solutions

Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach

Established Leaders in Actuation Technology. In-Vision PC based supervisory control. Publication S210E issue 04/03

Personal Handyphone Systems in Urban Infrastructure

SAINT Integrated Signaling System with High Reliability and Safety

CPAE PROCESS AUTOMATION INDEX. 2 Brands of PLCs (Keyence & AB) 1 Brands of SCADA (Wonderware Intouch) Pneumatics & Field Instruments

General Specifications

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Remote communication options include IEC Ethernet communications or Modbus (RS485).

COMPACT FLEXIBLE ALL IN ONE INDUSTRIAL PUMP CONTROL ELECTRONIC MONITORING SYSTEM CONTROLLER

HPP Kidatu (4x50 MW) - Control System Upgrade AUTOMATION

MicroNet TMR Control System

MX 62. Monitoring system for gas and flame detection. Certifications. Back up processor to ensure continual measurement (SIL 3 from EN 50402)

310SV SINGLE VALVE GOVERNOR

Oil, Gas, Power Plant & Others>>> Core Business D

D2-01_12 DISASTER-RESILIENT TELECOMMUNICATIONS SYSTEMS FOR SMART GRID IN JAPAN

March 21, Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series. ROC 300 and 407 Customers,

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

Automation System TROVIS 5400 District Heating Controller TROVIS 5475

MP7. Uninterruptible Power Supply

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

Development Of EMCS In Power Plants

Modernization of the National Wide Dispatch Centers of CADAFE - Venezuela

GSEP Sectoral Working Groups (Power WG, Steel WG, Cement WG) Ministry Economy,Trade, and Industry

TAPCON NEXT-GENERATION VOLTAGE REGULATORS. transformer control

UA-5200 IIoT Communication Server

750 XTR Series TAKING IT TO THE EXTREME THE STANDARD FOR 750 XTR

Supervisory Control for Metro Station Using PLC & SCADA

PLC control system and HMI in the Pharmaceutical World

Inform IT Information Management Tenore. SCADA Extension ABB

Redundant System Redundant System P9-1-1

3/2/ /2/ :05 AM EET 415/4 Power System Operation 1 3/2/ :05 AM EET 415 2

Procontrol P14 Complete power plant control system

Substation Automation Products. Line differential protection RED670 Relion 670 series

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

Engineering SCADA (Introduction) Dr. Sasidharan Sreedharan

Research on Technologies in Smart Substation

I/O Expansion Units. 5.1 I/O Expansion Units Overview P Overview P RS-485 I/O Expansion Unit P5-2-1

Digitization of Field Asset Visual Inspections

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

CombustionMaster Control Solutions. Unique Combustion Control for Gas and/or Oil-Fired Boilers

Real-time Power System Operation. Energy Management Systems. Introduction

OP-PDH-16E1+4FE-1+1-P

4000 SERIES REGULATED HIGH VOLTAGE DC TO DC CONVERTERS

Turbine Controller.

General Specifications

Centralized Site Management

w w w. z i g s e n s e. c o m. a u

the Centric 300 An advanced modular UPS up to 1800kVA/kW

PREPARING YOUR SYSTEMS FOR EFFICIENCY

High Availability Fieldbus Networks New Physical Layer Technologies. : Nagesha Nayak : Manager Project Pursuit

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

The Application of CAN Bus in Intelligent Substation Automation System Yuehua HUANG 1, a, Ruiyong LIU 2, b, Peipei YANG 3, C, Dongxu XIANG 4,D

RS-232 Serial RS-485 Serial Ethernet

MHPS-TOMONI: Thermal Power Generation Digitalization Platform Cloud/Edge Service and System Architecture

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

SLD-CS-series Compact High Power Broadband Light Source Modules.

General Specifications

505 Enhanced Digital Control for Steam Turbines (with Redundancy)

Transcription:

Hitachi Review Vol. 52 (2003), No. 2 111 Hitachi s Latest Supervisory, Operation and Control System for Thermal Power Station Isao Kume Shigeki Adachi Kazuo Furudate OVERVIEW: Hitachi supplied Jiangxi Jiujiang Phase III Power Generating Co., Ltd. in China with Hitachi Integrated Autonomous Control System 5000M (HIACS-5000M) as the supervisory, operation and control for the company s plant equipment. Hitachi s expertise in plant control as a turbine, generator, and boiler supplier, are reflected in this. The plant s reliability and maintainability have improved by this adoption. In addition, Hitachi has reduced the costs related to the cable using an (remote terminal block), and has proposed the rationalization of equipment by using a digitalizing protection interlock panel. Both result in greater economical efficiency. Operability and maintainability have also improved by incorporating an HMI (human-machine interface), which features a 100-inch screen. The Plant Unit 1 began commercial operations in December, 2002, and so did the Plant Unit 2 in May, 2003. INTRODUCTION ON December 15, 2002, Plant Unit 1 and on May 29, 2003, Plant Unit 2 of Jiangxi Jiujiang Phase III Power Generating Co., Ltd., China, started commercial operations. It has coal-fired thermal power generation equipment with a 350-MW 2 capacity; Hitachi was in charge of the turbine, generator, and plant I&C (instrumentation and control). In this paper, we introduce the DCS (distributed control ) component of the I&C we supplied. The DCS that will monitor, operate, and control the power generation equipment, must greatly Customer Requirements for DCS High performance Reliability Maintainability Economical efficiency Operability HIACS-5000M Digital protection HMI, including LSD [High performance] High-performance CPU High-speed & large capacity network Duplicated CPU & network EWS featuring CAD Triple redundant PCM EWS featuring CAD [Economical efficiency] Reduced number of parts Hitachi s Solutions Duplicated communications lines [Economical efficiency] Reduced cable material & cabling cost Autonomous decentralized Various powerful functions [Operability] User-friendly interface CPU: central processing unit EWS: engineering work station CAD: computer-aided design PCM: programmable control module : remote terminal block LSD: large screen display Fig. 1 Hitachi s Solutions for Plant Control of Jiangxi Jiujiang Phase III Power Generating Co., Ltd. The general requirements of an advanced DCS that supervises, operates, and controls power plant equipment are listed. For such customer needs, Hitachi supplies the best solutions.

Hitachi s Latest Supervisory, Operation and Control System for Thermal Power Station 112 Unit control room Engineer s room LSD LSD POC POC EWS HDS 100-Mbps control network (µ 100-network) T-G scope Turbine control Sequence control Data acquisition Grid control room Fig. 2 Configuration of Main Control Equipment and Computers. The appropriate functional distribution for ideal plant control here is enabled by HIACS. Modulating control : µ 100-network : Serial communication : RS-232C communication (Modbus) POC: process operator s console HDS: historical data station for CWP (set on CWP house) Burner management (including fuel safety ) Local area for boiler for turbine (set on boiler top) (set on turbine floor) increase the client s economical efficiency, operability, reliability, and maintainability. To meet these requirements, Hitachi used its HIACS-5000M (see Fig. 1). Hitachi s experience and know-how in plant control, as a turbine, generator, and boiler supplier, are reflected in this. Indeed, Hitachi can be the ideal plant control supplier regardless of who is supplying the turbine, generator, and boiler. OUTLINE OF DCS AT JIANGXI JIUJIANG PHASE III POWER GENERATING CO., LTD S POWER PLANT The DCS is mainly composed of control s including those for the boiler, sequence, electricity, and burners as well as DAS (data acquisition ) and an HMI (human-machine interface) to monitor and operate the plant. The burner control includes a boiler protection consisting of a digital protection interlock. For the Jiangxi Jiujiang Phase III Power Generating Co., Ltd. s power plant, Hitachi also supplied a turbine monitoring and control as well as the DCS. Because the turbine monitoring and control is incorporated in the control network of the DCS, no special interface is required for the configuration. As a result, the entire operational is unified in this power plant, making it possible to continuously monitor and control the entire plant efficiently (see Fig. 2). SUPERVISORY CONTROL SYSTEM CONFIGURATION AND CHARACTERISTICS Supervisory Control System For the CPU, we used a high-performance and reliable controller equipped with 32-bit RISC (reduced instruction set computer); for the configuration, we used duplicated CPUs to ensure safe and continuous operation of the plant. A state-of-the-art CAD was installed on a Hitachi EWS, to provide exact one-to-one correspondence between the software logic and documents. For the control network to connect these CPUs, we used a high-speed and large-capacity optical network with a transmission rate of 100 Mbps. Because this network provides a loop-back function, when there is trouble due to cable breakage, breakdown of communication equipment, etc. during transmission, the areas of malfunction are avoided, so communication can continue without significant disturbance. The I/O (input and output) interface is equipped with an SOE (sequence of event) function, in addition to the ordinary PI/O (process input and output). Because the SOE signal status can be detected at a resolution of 1 ms, it is very helpful for analyzing the cause of problems.

Hitachi Review Vol. 52 (2003), No. 2 113 Fig. 3 Unit Control Room for Jiangxi Jiujiang Phase III Power Generating Co., Ltd. A user-friendly human interface is implemented through CRTs by having both individual screens and a large screen for common use. HMI System The HMI can be roughly divided into two s: one for operation and monitoring by individual operators, and the other for common monitoring. For the common monitoring equipment, a large 100-inch screen was used to facilitate sharing information among all the operators. For the operator station hardware, we used HF-W, which is capable of 24-hour continuous operations with enhanced reliability due to the use of long-lasting parts and a stronger cooling. In addition, HF-W supports various functions based on globally standardized PC (personal computer) technology. For the operator station software, we used HIACS-W based on an autonomous decentralized, thus making possible a highly reliable HMI (see Fig. 2). By using the autonomous decentralized, many pieces of equipment are functionally distributed so that the entire control s functions will not be affected by the failure of a single mode. The HIACS-W can be implemented on various PC platforms. This provides superior real-time performance as well as a variety of functions, such as a mimic diagram display, a historical trend display, an alarm display, and various logs. It also features powerful plant monitoring functions such as a trip log, a process record, and an SOE log. CRT (cathode-ray tube) operation is possible not only on the screen Fig. 4 Example of Mimic Diagram with CRT Operation. By placing CRT operator functions on a mimic diagram, operators can execute optimum operations easily while monitoring the screen. dedicated to eight control terminals, but also on the mimic diagram screen, thus enhancing operability (see Figs. 3 and 4). Remote Terminal Block The enables easy front access wiring as well as the removal and installation of the wiring block. These features are especially useful for direct cable wiring, both in the workshop and the field. With each, separation between high-voltage circuits and electronics circuits is enabled, and analog and digital I/O signals (for operation and monitoring) are communicated between the and the controller through high-speed serial transmission. Because its line is duplicated, the reliability is high. Using the reduced the amount of cable material and the cost of cabling. For this plant, we installed an on the boiler top (to monitor temperature), in the turbine floor (to monitor temperature), and in the CWP (circulating water pump) house (to operate and monitor). In particular, for the panel in the CWP house built on the side of a river, we used optical fiber cables because this CWP is about 2 km from the electrical room where the controllers are: This made it possible to greatly reduce the cables (by 90% or more) needed between the two sites (see Fig. 5). Because the boilertop panel is subject to severe ambient conditions, we adopted an outdoor-type panel (equivalent to NEMA 4) that does not need an additional enclosure to cover the panel. Furthermore, it can withstand dust, water, high temperatures, and condensation.

Hitachi s Latest Supervisory, Operation and Control System for Thermal Power Station 114 Electrical room in central building Circulating water pump house Protection interlock panel Cable for serial communication Controller interface Amount of cable reduced more than 90%. Approx. 2 km specification Between and interface: Max. 1 km (electrical)/3 km (optical) Communication speed: 3 Mbps/1.5 Mbps/770 kbps/380 kbps Communication RAS: Dual transmission line Field Start/stop signal allows flexible location of process I/O terminals, even in the field. Shortest cable CWP Controller (monitoring and discrepancy detection circuit) Triple redundant circuit PCM (A) (B) (C) Monitor TB Test Trip interlock DI Trip signal Monitor Same as (A) Same as (A) Other cause DO DI DO DI DO Isolation 2 out of 3 logic trip circuit Fig. 5 Example of Remote Monitoring and Operating. The can monitor and operate distant equipment with the same reliability as operating from the electrical room. Moreover, the cable material and cabling costs were reduced by using serial communication. Trip signal DI: digital input DO: digital output TB: terminal block Fig. 6 Summary of the Protection Interlock Circuit Structure. Reliability s providing certainty of hardware and flexibility of software are implemented by the triple redundant structure of PCM. APPLICATION OF DIGITAL PROTECTION SYSTEM TO FUEL SAFETY SYSTEM We applied a digital protection for the FSS (fuel safety ) to protect the boiler. The conventional protection interlock panel is entirely composed of hardware requiring a lot of fabrication work and modification. Hitachi adopted a PCM having a nonvolatile memory, which is regarded as reliable hardware. This made it possible to reduce the number of parts and to greatly improve the reliability, and it also resulted in a more reliable and cost-effective than a conventional one. The features of the digital protection are as follows: (1) Triple redundant PCM (2) Circuitry visualized and rationalized by adopting PCM (3) Test and alarm circuit functions Triple Redundant PCM The PCM is triple redundant, with each separate and independent so that the protective functions will not be lost in the event of a single failure or single malfunction, thus ensuring high reliability and maintainability. The trip causes are input to trip interlock in each PCM through a terminal board, and the output trip signals from each PCM are initiated through 2 out of 3* logic trip circuits, thus guaranteeing its reliability. Circuit Visualizing and Rationalizing by Adopting PCM The PCM can work even when the controller (consisting of monitoring and discrepancy detection functions as shown in Fig. 6) fails, and it has an autonomous decentralized function that can perform protection functions independently. The logic circuit in the nonvolatile memory can be monitored through an EWS, and the logic can be loaded through the EWS when it needs to be changed. Because the functions enabled by the hardware are installed in the nonvolatile memory as software, the hardware components have been reduced, which has greatly improved the * 2 out of 3 is a voting logic that produces an output by selecting the majority vote from 3 inputs.

Hitachi Review Vol. 52 (2003), No. 2 115 maintainability, reliability, and the flexibility of the for future functional enhancements. Test and Alarm Circuit Because the high reliability of the protection is essential to being able to stop in an emergency caused by troubles during plant operation, a test and alarm circuit is equipped with functions to monitor and detect the operating status of the PCM as well as the discrepancy among s. It also has a channel test function to check if the trip command from each is normal, thus making it possible to ensure that the will always be reliable. CONCLUSIONS We have explained the benefits that resulted from using our HIACS-5000M at Jiangxi Jiujiang Phase III Power Generating Co., Ltd., China. In the electric power industry, customers needs are diversifying, and demands for a highly advanced distributed control are increasing. For the supervisory and control, we also paid careful attention to the safety and efficiency of the plant, and we will continue to work to satisfy these needs. REFERENCES (1) S. Takahashi et al., Advanced Information and Control System for Thermal Power Stations, Hitachi Review 46, pp. 143 146 (June 1997). (2) A. Ito et al., High-Reliability, Next-Generation Supervisory and Control System for Power Stations, Hitachi Review 47, pp. 214 218 (Oct. 1998). (3) T. Iijima et al., Hitachi s Latest Supervisory and Control System for Advanced Combined Cycle Power Plants, Hitachi Review 51, pp. 153 157 (Dec. 2002). ABOUT THE AUTHORS Isao Kume Joined Hitachi, Ltd. in 1996, and now works at the and design of power plant supervisory and control equipment. Mr. Kume can be reached by e-mail at isao_kume@pis.hitachi.co.jp. Shigeki Adachi Joined Hitachi, Ltd. in 1973, and now works at the and design of power plant supervisory and control equipment. Mr. Adachi can be reached by e-mail at shigeki_adachi@pis.hitachi.co.jp. Kazuo Furudate Joined Hitachi, Ltd. in 1970, and now works at the and design of computer for thermal power plants. Mr. Furudate is a member of The Institute of Electrical Engineers of Japan (IEEJ), and can be reached by e-mail at kazuo_furudate@pis.hitachi.co.jp.