Precision N Coaxial Calibration Kit

Similar documents
Automated Tuner System Power Distribution Hub

TNC VNA Calibration Kits

3.5mm VNA Calibration Kits

2.92mm VNA Calibration Kits

365XA, 365XA-1, 365XD, and 365XD-1 Mechanical Calibration Kits

SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL

Keysight M8000 Series BER Test Solutions

VectorStar Broadband/Banded Millimeter-Wave Modules

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

User s and Service Guide

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies 85050B 7 mm Calibration Kit

ELECRAFT P3 HIGH-PERFORMANCE PANADAPTER P3SVGA OPTION INSTALLATION AND OPERATING INSTRUCTIONS. Rev B, March 20, 2012

User s and Service Guide

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

Keysight Technologies 85031B 7 mm Calibration Kit

11525A 11524A

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

SAVE THESE INSTRUCTIONS

Biesemeyer Fence Kit Installation Instructions:

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Ioline 300/350HF System

Keysight 85032F Type-N 50 Calibration Kit

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Keysight Technologies 85052B 3.5 mm Calibration Kit

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Advanced Test Equipment Rentals ATEC (2832)

500 SERIES. Hardware Installation and Modification Manual. Process Controllers. for Electronic Products Series 531, 532, 535, 545, 555 Model 2

MPP200 User s Manual

Keysight Add Source and Receiver Attenuators Upgrade Kit

Keysight 42941A Impedance Probe Kit

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Keysight Technologies 85131C/D/G NMD-3.5 mm -fto 3.5 mm Semi-Rigid Test Port Return Cables

User s and Service Guide

FMCK1013 DATA SHEET. Features: Applications: Configuration. Mechanical Specifications

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

RF Connector Handling Guidelines

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

ANC Series RS-422 Serial Communications Adapter

User s and Service Guide. Agilent Technologies 85033E 3.5 mm Calibration Kit

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Software User s Guide

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

PML 791-RO Low-Z Passive Probe. Instruction Manual

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

User s and Service Guide

Keysight 85052D 3.5 mm Economy Calibration Kit

User s and Service Guide

An ISO-9001 Certified Company

Keysight 909A/D Coaxial Terminations

spinner Measurement & Calibration equipment for network analyzers

Shop Fox Fence Kit Installation Instructions:

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Model VT120 Fast Timing Preamplifier Operating and Service Manual

User s and Service Guide. Agilent Technologies 85052C 3.5 mm Precision Calibration Kit

User Guide. Moisture Meter. Model MO250

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

87421/22A Power Supply. Operating and Service Manual

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Elecraft K3 KPA3 Power Connector Replacement Revision B, June 30, 2017 Copyright 2017, Elecraft, Inc. All Rights Reserved

Elecraft KXIO2 Real Time Clock and Control Interface Installation Instructions

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

Wall. No opening (Example: LA-030-W)

01-161, -162, -163, AND -164 GAUGING SETS USER S GUIDE

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

MODEL 245 / 345 High Range

Operating and Service Manual

User s and Service Guide

FA-2448 SIX POSITION Filter Wheel

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

User s and Service Guide

G12/G12x USER S MANUAL

Rackmount Keyboard Installation Instructions. Revision A A-0000

STRATUS ULTRA-G User Guide

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

Dell OptiPlex All-in-One. Stand Installation Guide

Reference Guide. Agilent Technologies Electronic Calibration Modules. RF Two-Port 85091C 85092C 85093C 85096C 85098C 85099C. RF Four-Port N4431B

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

N5532B Sensor Module User s and Service Guide

User's Guide. Phase Sequence and Motor Rotation Tester Model

TCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE)

PIM-Mini Pulsed Current Source Operation Manual

ACLD Channel Opto-isolated Digital Input Board

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

MANUAL. Set-up and Operations Guide Glidecam Industries, Inc. 23 Joseph Street, Kingston, MA Customer Service Line

Transcription:

User Guide Precision N Coaxial Calibration Kit DC to 18 GHz Models: 8850CK10/11 8850CK20/21 8850-511 (A) 3/15

User Guide Precision N Coaxial Calibration Kit DC to 18 GHz Models: 8850CK10/11 8850CK20/21 2900 Inland Empire Boulevard Ontario, California 91764-4804 USA Telephone: (909) 987-4715 Facsimile: (909) 987-1112 maurymw.com Copyright 2015 Maury Microwave Corporation. All rights reserved.

Warranty Maury Microwave hardware products are warranted against defects in materials and workmanship for a period of one year from date of shipment. During the warranty period, Maury Microwave will, at its option, either repair or replace products which prove to be defective. Maury Microwave software products are warranted against defects in material and workmanship of the media on which the product is supplied for a period of ninety (90) days from date of shipment. Maury also warrants that the product shall operate substantially in accordance with published specifications during the same warranty period. During the warranty period, Maury Microwave will, at its option, either repair or replace products which prove to be defective. Maury does not warrant that the operation of the product shall be uninterrupted or error-free. For warranty service or repair, all products must be returned to Maury Microwave and must be issued a return authorization number by Maury prior to shipment. Buyer shall prepay shipping charges to Maury. Obligation is limited to the original Buyer. Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or wear resulting from normal use. No other warranty is expressed or implied. Maury Microwave specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. The remedies provided herein are the Buyer s sole and exclusive remedies. Maury Microwave shall not be liable for any direct, indirect, special, incidental, or consequential damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or any other financial loss) arising out of the Buyer s use of or inability to use the product, even if Maury or an authorized Maury dealer has been advised of the possibility of such damages.

Contents General Information... 1 Calibration Kit Description... 1 Maintenance... 1 Calibration... 1 Supporting Test Port Adapters... 1 Electrostatic Discharge Precautions... 1 Connector Description... 2 Connector Care... 2 Connector Tightening... 3 Sliding Termination Preparation... 4 Connecting the Sliding Termination... 6 Sliding the Termination Element... 6 Flush Set Interface... 6 Calibration Kit Contents... 7 Standard Definitions... 9 Anritsu Network Analyzers... 9 Keysight Network Analyzers... 10 Rohde & Schwarz Network Analyzers... 11 Appendix... 13 Data Sheet Resources... 13 Contacts... 15 8850-511 (A) 3/15 i

Contents Tables Table 1. Male Standard Definitions for Anritsu... 9 Table 2. Female Standard Definitions for Anritsu... 9 Table 3. Standard Definitions for Keysight... 10 Table 4. Standard Definitions for Rohde & Schwarz... 11 Figures Figure 1. Using the Torque Wrench... 3 Figure 2. Sliding Termination Parts... 4 Figure 3. Vector Diagram... 6 ii 8850-511 (A) 3/15

General Information Calibration Kit Description This series of Precision N coaxial calibration kits is designed to provide accurate calibrations of network analyzers in the DC to 18.0 GHz range. Each of these kits includes all the necessary calibration standards and associated hardware needed for the accurate calibration of most network analyzers. Refer to the Calibration Kits Contents section (see Appendix, Date Sheet Resources) for information on included components and available kit options. NOTE: This document, calibration constants software, and data sheet can be downloaded from our website: maurymw.com NOTE: Legacy analyzer software is not on our website but is available for purchase. Maintenance This calibration kit is relatively maintenance free if the components are handled with the same care that is appropriate to all precision equipment. As with any precision component, proper care should be taken to assure clean mating surfaces, correct alignment when mating, and proper torquing of connectors or waveguide coupling screws. To help maintain the integrity of the components in this kit, routine visual inspection and cleaning of mating surfaces is recommended. Failure to do so may result in degraded repeatability and accuracy, as well as damage any mated devices. Calibration To maintain verification that a calibration kit is performing to traceable specifications, we recommend that all kits be periodically returned to Maury Microwave for calibration. The typical calibration cycle is one year, although actual need may vary depending on usage. Supporting Test Port Adapters When configuring a test setup, be sure that damaging stresses are not applied to the connectors on the test set. This is particularly critical when the attached components are heavy or long. Always properly support the test port adapters being used. Electrostatic Discharge Precautions Protection against electrostatic discharge (ESD) is essential while inspecting, cleaning, or making connections to connectors attached to a static-sensitive circuit, such as those found inside test sets. When handling the connectors on the test set, be aware that you are coming in contact with exposed center conductors that are connected directly to the static-sensitive internal circuits of the network analyzer. Make sure that you and your equipment are well-grounded before inspecting, cleaning, or making connections to test set ports. Standard ESD precautions, such as the use of grounded wrist straps and grounded antistatic mats, are recommended. 8850-511 (A) 3/15 1

General Information Connector Description All calibration standards and adapters in the 8850 series kits utilize the Maury Microwave Precision N Connector, which is compliant with MIL-C-39012 specifications. Refer to Maury Microwave data sheet 5E-049 for a complete description of the connector. Connector Care Precision connectors must be handled carefully if accurate calibrations and measurements are to be obtained. All connectors should be inspected prior to each use. For optimum measurement results, all interfaces should be visually inspected under magnification and cleaned on a regular basis. Proper connector contact pin depths should also be verified through regular inspections using a connector gage, such as the Maury Microwave A020K connector gage kit, to insure that the connectors on both calibration devices and devices under test (DUTs) have contact pin depths within recommended tolerances. Refer to Maury data sheet 5E-049 (available on our website) for proper pin depth specifications. Care should be used whenever aligning connectors. Tighten connector coupling nuts using an appropriate torque wrench while holding the opposing connector with an open-end wrench. When disconnecting devices, take care not to rock or bend any of the connections. Disconnect devices by disengaging the coupling nuts and gently pulling the connectors apart in a straight line. Always use protective covers on all connectors when devices are not in use. Should a connector become damaged, it should be repaired before it is used any further or replaced immediately. A damaged connector can damage other mated connectors. 2 8850-511 (A) 3/15

General Information Connector Tightening Damage to a calibration device or attaching connector can occur if the device is turned instead of the connector nut. ALWAYS turn the nut when making connections. Never turn the device itself. Always use a torque wrench (Maury model 2698C2) to final-tighten all connections. This will insure calibration accuracy and measurement repeatability. When making connections, a 1/2 inch open-end wrench or a 9/16 inch open-end wrench may be required to hold the body of one device stationary while torquing the nut on the other device or cable. This double-sided wrench is supplied with this calibration kit for this purpose. Using the torque wrench, hand-tighten the connection to be torqued by holding the calibration device steady and turning only the nut. Hold the torque wrench with your thumb and index finger, behind the groove in the handle (see Figure 1). Tighten the connection until the ball in the handle crests on the cam (as the handle begins to break). Do not fully break the handle of the torque wrench to reach the specified torque. Reverse the previous procedure to disconnect the connection. Figure 1. Using the Torque Wrench 8850-511 (A) 3/15 3

General Information Sliding Termination Preparation Assemble the female or male connector adapter per the following section Installing the Connector Adapter and then install the contact per the following section Installing the Center Conductor (a through b), to make the sliding termination ready for use. Figure 2. Sliding Termination Parts Installing the Connector Adapter (Male or Female) a) Referring to Figure 2, connect the adapter (3) or (4) to the sliding termination assembly (1). Use the thin flat 9/16 open-end wrench supplied to hold the connector adapter and a 3/4 wrench on the housing nut of the termination assembly, then gently tighten securely. A slight amount of torque is required do not over tighten. b) To remove the connector adapter, hold it with the thin flat 9/16 open-end wrench and slowly unscrew by turning the nut on the housing using the 3/4 open-end wrench. c) After each use, remove the connector adapter and return it to the instrument case. 4 8850-511 (A) 3/15

General Information Installing the Center Conductor CAUTION: Handle with care. Do not bend, allow sagging, or scratch. Keep in instrument case when not in use. a) Thread the center contact (5) Female or (6) Male into the end of the center conduct (2), then tighten securely finger tight is adequate DO NOT USE PLIERS OR WRENCHES. Make sure the contact is fully bottomed and no gap exists. NOTE: Do not install contact while center conductor is in the instrument. Always remove the center conductor when changing contacts to prevent damage. It is good practice prior to each use to inspect the center conductors for nicks or scratches and wipe them off with a clean, soft, lint-free cloth. b) Loosen the collet lock at the rear of the termination assembly and insert the center conductor until it protrudes from the front end. c) To remove the center conductor, loosen the collet lock and pull the center conductor straight out. d) The center conductor, when not in use, should be kept in the instrument case to preserve straightness. Do not leave outside the instrument case and do not leave in termination assembly. e) Periodically inspect the center conductor using a surface plate to examine for straightness. 8850-511 (A) 3/15 5

General Information Connecting the Sliding Termination NOTE: The sliding termination should be properly supported by using a small lab jack (or equivalent) when connected to the device to be tested to avoid stress at the connector joint. a) With the rear collet lock loose and the center conductor protruding from the front end of the sliding termination, carefully align the center contact to the mating connector and gently insert the contact (engagement must be made straight on). Then screw on the connector adapter securely using the coupling nut. b) Push the center conductor knob at the rear of the housing (use slight pressure) to make sure a butt joint is achieved at the center contacts, then lock the rear collet (finger tight is adequate). This secures the center conductor so it will not move when the terminating element is moved. CAUTION: Do not exert excessive axial pressure or bowing of the center conductor may result. Sliding the Termination Element The purpose of sliding the terminating element is to change the phase of the reflection from the terminating element in order to separate it from other reflection present in the system (see Figure 3). The element is moved by the sliding collar on the termination assembly. Flush Set Interface A flush set interface can be set for Type N connectors using the following recommended resources: Maury thread-on connector gage kit model A020D, to set the interface. Maury torque wrench 2698C2, to achieve repeatable connections. Maury data sheets 2Y-003, 2Y-003A, and 2Y-050A, for more information. Figure 3. Vector Diagram 6 8850-511 (A) 3/15

General Information Calibration Kit Contents Standard Components 8850CK10 1 ea Short, female 8806C 1 ea Short, male 8807C 1 ea Open, female 8809B1 1 ea Open, male 8810B1 1 ea Fixed Termination, female 2510A6 1 ea Fixed Termination, male 2510B6 1 ea Case Assembly Standard Components 8850CK11 1 ea Short, female 8806C 1 ea Short, male 8807C 1 ea Open, female 8809B1 1 ea Open, male 8810B1 1 ea Fixed Termination, female 2510A6 1 ea Fixed Termination, male 2510B6 1 ea Adapter, male to male 8828B 1 ea Adapter, female to male 8828C 1 ea Adapter, female to female 8828A 1 ea Case Assembly Standard Components 8850CK20 1 ea Short, female 8806C 1 ea Short, male 8807C 1 ea Open, female 8809B1 1 ea Open, male 8810B1 1 ea Fixed Termination, female 2510A7 1 ea Fixed Termination, male 2510B7 1 ea Sliding Termination 2517A02 1 ea 3/4 Torque Wrench, 12in.lbs 2698C2 1 ea 1/2 and 9/16 double-end wrench 2517S3 1 ea Case Assembly Standard Components 8850CK21 1 ea Short, female 8806C 1 ea Short, male 8807C 1 ea Open, female 8809B1 1 ea Open, male 8810B1 1 ea Fixed Termination, female 2510A7 1 ea Fixed Termination, male 2510B7 1 ea Adapter, male to male 8828B 1 ea Adapter, female to male 8828C 1 ea Adapter, female to female 8828A 1 ea Sliding Termination 2517A02 1 ea 3/4 Torque Wrench, 12in.lbs 2698C2 1 ea 1/2 and 9/16 double-end wrench 2517S3 1 ea Case Assembly 8850-511 (A) 3/15 7

General Information (This page intentionally left blank) 8 8850-511 (A) 3/15

Standard Definitions Anritsu Network Analyzers Table 1. Male Standard Definitions for Anritsu Male Open Device C0 99.14 e-15 C1 353.60 e-27 C2 62.23 e-36 C3 0.00 e-45 Offset Length 1.1100 cm Serial Number 00000 Male Short Device Offset Length 1.261 cm Serial Number 00000 Table 2. Female Standard Definitions for Anritsu Female Open Device C0 103.00 e-15 C1 0.00 e-27 C2-110.00 e-36 C3 10.20 e-45 Offset Length 5.8220 cm Serial Number 00000 Female Short Device Offset Length 7.3485 cm Serial Number 00000 For specific loading instructions, see Anritsu loading instructions, which can be downloaded from our website: maurymw.com. 8850-511 (A) 3/15 9

Standard Definitions 10 8850-511 (A) 3/15 (1) (2) (3) Type Standard (1) Description Keysight Network Analyzers Table 3. Standard Definitions for Keysight C0 x10-15 F L0 x10-12 H C1 x10-27 F/Hz L1 x10-24 H/Hz C2 x10-36 F/Hz 2 L2 x10-33 H/Hz 2 C3 x10-45 F/Hz 3 L3 x10-42 H/Hz 3 Fixed or Sliding (2) Delay ps Offset Z0 (3) Ω Loss (4) GΩ/s Frequency GHz Short 8806C Female Short 24.512 50 0.7 0.0 999.0 Coax 8806C Open 8809B1 Female Open 103.0 0.0-110.0 10.2 19.420 50 0.7 0.0 999.0 Coax 8809B1 Min Max Coax or W/G Standard Label Load 2510A( ) Broadband Female Load Fixed 0.0 50 0.0 0.0 999.0 Coax 2510A( ) BB Thru Thru (0 cm) 0.0 50 0.0 0.0 999.0 Coax Thru (5) Load 2517( ) Sliding Female Load Sliding 0.0 50 0.0 1.999 999.0 Coax 2517( ) F Load 2510A( ) Lowband Female Load Fixed 0.0 50 0.0 0.0 2.001 Coax 2510A( ) LB Short 8807C Male Short 42.063 50 0.7 0.0 999.0 Coax 8807C Open 8810B1 Male Open 99.14 353.6 62.23 0.0 37.026 50 0.7 0.0 999.0 Coax 8810B1 Load 2510B( ) Lowband Male Load Fixed 0.0 50 0.0 0.0 2.001 Coax 2510B( ) LB Load 2517( ) Sliding Male Load Sliding 0.0 50 0.0 1.999 999.0 Coax 2517( ) M Load 2510B( ) Broadband Male Load Fixed 0.0 50 0.0 0.0 999.0 Coax 2510B( ) BB Open, short, load, delay/thru, or arbitrary impedance. Load or arbitrary impedance only. Z 0 normalized. (4) (5) Skin loss factor, normalized at 1 GHz. Test ports connected directly. For specific loading instructions, see Keysight loading instructions, which can be downloaded from our website: maurymw.com

Standard Definitions Rohde & Schwarz Network Analyzers Table 4. Standard Definitions for Rohde & Schwarz THROUGH (MF) LABEL = THRU 0 mm MIN FREQ = 0 Hz MAX FREQ = 18 GHz LENGTH = 0 mm LOSS = 0 db/ GHz SHORT (M) LABEL MIN FREQ MAX FREQ LENGTH LOSS = 8807C = 0 Hz = 18 GHz = 12.61 mm = 0.005115 db/ GHz OPEN (M) Label = 8810B1 Min Freq = 0 Hz Max Freq = 18.0 GHz Length = 11.1 mm Loss = 0.0045025 db/ GHz C0 = 99.14 ff C1 = 0.3536 ff/ghz C2 = 0.06223 ff/ghz 2 C3 = -0.0 ff/ghz 3 SHORT (F) LABEL MIN FREQ MAX FREQ LENGTH LOSS = 8806C = 0 Hz = 18 GHz = 7.349 mm = 0.0029807 db/ GHz OPEN (F) LABEL = 8809B1 MIN FREQ = 0 Hz MAX FREQ = 18 GHz LENGTH = 5.822 mm LOSS = 0.0023615 db/ GHz C0 L0 = 103.0 ff C1 = 0.0 ff/ghz C2 = -0.11 ff/ghz 2 C3 = 0.0102 ff/ghz 3 MATCH (M) LABEL = 2510B( ) MIN FREQ = 0 Hz MAX FREQ = 18 GHz MATCH (F) LABEL = 2510A( ) MIN FREQ = 0 Hz MAX FREQ = 18 GHz SLIDING MATCH (F) LABEL = 2517( ) MIN FREQ = 2 GHz MAX FREQ = 18 GHz SLIDING MATCH (M) LABEL = 2517( ) MIN FREQ = 2 GHz MAX FREQ = 18 GHz For specific loading instructions, see Rohde & Schwarz loading instructions, which can be downloaded from our website: maurymw.com. 8850-511 (A) 3/15 11

Standard Definitions (This page intentionally left blank) 12 8850-511 (A) 3/15

Appendix Data Sheet Resources 2Z-061 Precision Type N VNA Calibration Kits http://maurymw.com/pdf/datasheets/2z-061.pdf 2Y-001 Connector Gages and Connector Gage Kits http://maurymw.com/pdf/datasheets/2y-001.pdf 2Y-003 Type N Precision Connector Gage Kit http://maurymw.com/pdf/datasheets/2y-003.pdf 2Y-003A Metrology Grade Type N Precision Connector Gage Kit http://maurymw.com/pdf/datasheets/2y-003a.pdf 2Y-050A Torque Wrenches http://maurymw.com/pdf/datasheets/2y-050a.pdf 8850-511 (A) 3/15 13

Contacts Corporate Maury Microwave Corporation 2900 Inland Empire Boulevard Ontario, California 91764-4804 United States of America Tel. 909-987-4715 Fax 909-987-5855 Email maury@maurymw.com Sales Tel. 909-204-3224 Fax 909-987-1112 Email maury@maurymw.com Customer Support Tel. 909-204-3283 Fax 909-987-1112 Email support@maurymw.com Website maurymw.com Web Resources Maury Calibration Kits http://maurymw.com/precision/vna_cal_kits.php Maury Precision Coaxial and Waveguide-to-Coaxial Adapters http://maurymw.com/finder/adapter_finder.php Maury Applications Notes Library & Technical Articles Archive http://maurymw.com/support/tech-support.php Maury Sales Representative Finder http://maurymw.com/support/find-sales-rep.php Visit our website for additional product information and literature.