Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

Similar documents
HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Sapling Converter Box

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

FCU-4 FAN COIL CONTROLLER

Circular and semi-circular displacement outlet Q-Z...

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

IBIS. Duct diffuser with discs for supply air QUICK FACTS

Product data sheet accessories control and regulation Accessories AIRWIN

Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building

Pixel Panel 144 RGB effect panel. user manual

Control systems. Efficient room control

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

Ex emergency pull-wire switches Ex ZS 71

EC axial fan - HyBlade

Non-communicating room controllers

Insulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting

Chameleon Stand-alone

IBISTM. Duct diffuser with discs for supply air

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

VIREO Ceiling with ALX

User's Guide. Model W 3-in-1 Switching DC Power Supply

Stripes. 19" Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS...

AirTest Model CN9000 Series Sensor Controller

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

xbrick Full-Colour 16 3W LED floodlight user manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

FM100 Fume hood monitoring system according to EN 14175

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

PRODUCT UPDATE 2011 Smart Manager BMS-SM1280HTLE. Note: Computer NOT supplied

INTELLIGENT SERVER. Model: BMS-LSV6E

dynamic white par manual

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

Ventilation grille. Dimensions

Specification Sheet: HT SERIES

FCU-4 FAN COIL CONTROLLER

LED Pixel Rail Drive 640 controller. user manual

Product Brochure Edition 1. t: f: e: doncastercables.com

Adjustable swirl diffuser PDZA TECHNICAL DATA

Room controller STRA-17

Cleanroom Equipment & Accessories Brochure

THERMOSTAT OPERATING MANUAL. Digital T3SQ-2. Redefine your comfort zone.

LED Controls. Lighting Controls. LED Controls

EMC1600 Series Media Converter and Ethernet Extender Chassis

Light Source User Guide

DRI. VARIZON Displacement unit with adjustable spread pattern

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Products no longer available

MNS ACS880 Switchgear mounted industrial drives

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

20W Tungsten-Halogen Light Source. Operation Manual

Variable Flow Rate Control Unit

E4PA. Ultrasonic Displacement Sensor. Ordering Information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Compact UV wash featuring ultra wide coverage and high-output COB LED

NETRONICS HS3500 CONTROLLER

INSTALLATION MANUAL SLI 50 INVERTER

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Floormaster DVQA, quarter-cylindrical terminals

Light Source User Guide

SOLARIMMERSION IV Advanced Installation Manual v1.9

M1000 INTELLIGENT ZONE CONTROL SYSTEM

PRO I Series CAPACITANCE PROBE

Alternative B Type Mid-Span Power Sourcing Equipment. User s Guide

USER S MANUAL. DAS-G01 The Power of Tomorrow

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Gas-actuated thermometer Stainless steel version Model 73

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

DUAL LASER PACK & CONTROLLER USERS MANUAL

Electromechanical pressure switches

Eco IndustryLine Single-module functional lighting

VBAR 270. User Manual. Version 1.2

Typ FMS FOR THE MONITORING OF VOLUME FLOWS

STRUCTURED CABLING WORKS SCHEDULE 1: GROUND FLOOR ITEM DESCRIPTION QTY UNIT RATE KSH

InBin-P Pressure switches from 5 Pa Pa

ECL Comfort V a.c. and 24 V a.c.

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Insulated Enclosure KU 4087, KU 4088 KU 4089 to DIN for installation in distribution cabinets or surface mounting

Street Light. T011A Series

Thermal Mass Flowmeter Sensyflow FMT200-D

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

IMPORTANT SAFETY INSTRUCTIONS

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Temperature Controller

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Linear Luminaire with LED Series 6012/5

Lighting & HVAC Control System

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Nova Light Source Range

MLS7A Series. Photoelectric Sensors. Heavy-Duty Retro-Reflective Sensors. Photoelectric MLS7A Series Heavy Duty PEPPERL+FUCHS 529

Compact pressure switch for multiple actuators

Differential Pressure Controller DPC 200

Encoder mounting attachments Fixing components for shaft encoders Overview mm, 4 mm thick mm, 3 mm thick. 5 mm thick.

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

Transcription:

TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788 288/388 E-mail : trox@troxmal.com.my http://www.troxmal.com.my Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1 Description TROX 3-speed fan terminal units with TROX FBA/250 Type circular floor diffuser in die cast aluminium complete with wall mounted temperature sensor to each unit. The wall sensor allows the building occupants to adjust the room set point temperature, and the fan speed manually or automatically. Fan Speed Air Flow Velocity rate (l/s) (m/s) Low 34 1.1 Medium 45 1.7 High 60 2.4 Constructions The fan casing is manufactured from 0.7mm thickness galvanized sheet steel with 25mm thickness internal glass fibre insulation for acoustic purpose. Each unit will come with a 3-core PVC insulated power supply cable complete with a 13 Amp 3-pin plug. Dimension & Weight L 444 mm x W 343mm x H 238mm Weight: 9 ~ 10kg (including wall terminal) 1

TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788 288/388 E-mail : trox@troxmal.com.my http://www.troxmal.com.my Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1 Blow up view Fixing Method Features Plug and play Can be Stand alone or Master slave configuration Master Slave up to 8 boxes Total length for communication cable Max. 250m Contains standard low, medium and high speed fan. Easy installation and maintenance 2

TROX Malaysia Sdn. Bhd. (278360-V) 20, Persiaran Bunga Tanjong 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan Darul Khusus, Malaysia Telephone : (+6) 06-6788188 Telefax : (+6) 06-6788 288/388 E-mail : trox@troxmal.com.my http://www.troxmal.com.my Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1 Connection Diagram Specification Power supply: 240Vac 50/60 Hz Controller Control Wall Terminal RJ11 socket for master slave connection 10A Fuse Order Code FAT / M / 2 / 5 Type : FAT 250 Configuration : M Master (complete with wall terminal) S Slave (without wall terminal) Power Cord Length 2 2 meters 3 3 meters 5 5 meters Z custom length Communication Cable Length 3 3 meters 5 5 meters 10 10 meters Z custom length 3

Proposed control strategy for Stand Alone application and installation guide for TROX Type FAT Fan Assisted Terminal Unit Each FAT unit will be supplied with a wall mounted temperature sensor complete with fan speed controller and LCD display. The fan speed controller provides the option of controlling the fan speed manually or automatically, with 3 speed settings (i.e., low, medium and high), on/off control and room temperature set point adjustment. Standard FAT units are designed for stand-alone application. Under automatic control mode the fan speed will be adjusted automatically when the measured room temperature rises above or falls below the room set point temperature by 2 C. To change from auto mode to manual, the building occupants have the set that manually on the wall mounted sensor and controller. The FAT unit is generally powered up when the AHU starts operation. A 24 V a.c. signal can be supplied via a relay to energise the FAT units that are linked to a particular AHU when it is activated according to their zone. However, if the FAT units are required to be connected to the Building Management System (BMS), this can be done provided that the Design Consultant provide TROX with their controls performance specification at initial design stage so that TROX may prepare a proposal that would best suit the design performance requirements before TROX can provide a quotation. Such request will be dealt with based on project by project basis, which depend largely on each specific project requirement. TROX Malaysia Sdn Bhd Page 1

Installation Guide: The FAT unit is located in the floor void and supported by TROX FBA/ 250 floor diffuser that is installed to the floor tile. The floor tile should have a ready-made hole of 268 mm Ø (i.e., internal diameter ± 2 mm) to allow the FBA/250 Floor Diffuser to be fitted on it. Two installation methods are available with this FBA/ 250 floor diffuser; Method One: With clamping bolts Trim ring Floor tile Camping bolt Method Two: With spring clip Rear view of the trim ring with spring clip fitted. This method is simple to install the floor diffuser to the floor tile. However, the minimum thickness of the floor tile must be at least 20 mm. Trim ring Floor tile Spring clip TROX Malaysia Sdn Bhd Page 2

Controls Strategy: As shown in the schematic diagrams below, there are two basic methods to control the FAT terminal units. 1. One to one control arrangement: For private offices, one may need this to control the FAT units for personalised thermal control environment. The user may choose to set the set point temperature and fan speed adjustment according to his or her desire. 2. Group control arrangement: With this arrangement, one wall mounted temperature sensor and fan speed controller may by connected up to 8 nos. FAT units (i.e., one master can only be connect up to seven slave units). However on electric power supply, one socket outlet should only provide electric power for a maximum four FAT units. The disadvantage with such an arrangement is if the master unit is faulty this will affect all the slave units that are linked to that master unit. TROX Malaysia Sdn Bhd Page 3

FAT AIR FLOW WHEN FAN IS SWITCHED OFF Fan Flow Rate (l/s) vs Floor Void Static Pressure speed 0 Pa 5 Pa 10 Pa 15 Pa 20 Pa 25 Pa OFF 0 17 27 34 40 45