Relative humidity Noise level 4-7" reels: 8-72 mm tapes 11-15" reels: 8-72 mm tapes Max. 3.5 kg

Similar documents
HIGHLY FLEXIBLE SMD PLACEMENT SYSTEM FOR SMALL AND MEDIUM ENTERPRISES

USTER ZWEIGLE TWIST TESTER 5-SA

USTER INTELLIGIN-M. The gin process control system. Technical Data

TA Instruments Installation Requirements for Microcalorimeter Systems

Facility Requirements Guide. ProJet X60 Series. INCLUDES: ProJet 160 ProJet 260C ProJet 360 ProJet 460Plus ProJet 660Pro ProJet 860Pro

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Nano DSC and MCDSC. Site Preparation Guide

DRILLING SERIES MULTISTATION EVOLUTION LZ NEW HIGH SPEED MODULAR MICRODRILLING STATION

NOTE: All facility requirements must be met before 3D Systems Customer Support can schedule a trip to your facility to install the printer.

TA Instruments Installation Requirements for Microcalorimeter Systems

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

D705. Specifications

Getting Started. Read Me First. series. Canon Inkjet Premium Photo Printer. 1 Preparation...P.1. Install the Print Head... P.3

BEETLE /M-II with Embedded Scale Controller and 2 Displays. Technical Information

USTER TESTER 5-C800. The filament yarn inspection system. Technical Data

TESLA 1U GPU COMPUTING SYSTEMS

Discovery Hybrid Rheometer

PanelView Plus/VersaView CE Terminals and Display Modules

u TESTER 6-C800 The quality testing system Technical Data

Standard specifications RS007LFF60

CNC Tube Bending Machine & its Software (On Turn key basis) SL. NO. DESCRIPTION OF REQUIREMENT REQUIRED 1 Scope

AutoPusher Saw System. Proudly Made in Ames, Iowa, U.S.A.

Specifications LAN *3

Common Mode Noise Filter. LCFE Series. Description. Features. Applications. 1210mm Size. Source Meter. LCR Meter (3GHz) Source Meter.

21023, 21025, 2/2 Direct solenoid actuated poppet valves

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

8M Tablet Hardness Tester

RESIDENTIAL ZMF100AC, ZMF100AB, ZFF100 TECHNICAL DATA. IEC-specific data Current Base current I b. Measurement Accuracy. Measurement Behaviour

Figure 1 shows the appearance of Huawei FusionServer RH8100 V3 Rack Server. The RH8100 V3 provides three front I/O modules:

Installation Manual of DS-9600NI-H8 DS-9600NI-H8. Installation Manual UD.7L0202A1730B01

Metal Detector Lineup

Product Tape and Reel, Solderability & Package Outline Specification

T3224 PRINTER. THERMAL TRANSFER PRINTER (600dpi) TECHNICAL DATASHEET

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

TA Instruments Installation Requirements for Microcalorimeter Systems

Technical Specifications

Professional Power Solutions Provider ISO 9001 : 2008

Product Tape and Reel, Solderability & Package Outline Specification

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

MarShaft. MarShaft SCOPE 250 plus

EMC SYMMETRIX VMAX 10K

Operating systems supported Windows 10 Home (64-bit) Windows 10 Professional (64-bit) Ubuntu 16.04

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Chapter 2. Specifications

DMT345 and DMT346 Dewpoint Transmitters

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Ambient Weather WS-HT350 Fast Response Air Thermo-Hygrometer with Wet Bulb, Dew Point Meter User Manual

Installation Manual of DS-7600NI-H2/P Series. DS-7600NI-H2/P Series. Installation Manual UD.7L0202D1761B01

PM1206STR. AC Power Switch INTEGRATED CIRCUITS DIVISION

TAM Air Isothermal Calorimeter. Site Preparation Guide

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Series 95000, 2/2 Direct solenoid actuated poppet valve

17 Panel PC / Monitor Mounting systems: Panel Mount / Rack Mount / open frame

Installation Job Aid for VSP 4850GTS

Operating pressure (bar) kv factor (m 3 /h) *3)

MID approval no. DE-08-MI004-PTB004 Date of release

Thunderbolt 3 USER GUIDE. For more information visit

ADP Dot Peen Marking Machine

DIP Switch (Slide Type)

Installation Job Aid for VSP 4450GTX-HT- PWR+

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

GP SERIES Packaged Chillers

Getting Started. Read Me First. series. Photo Printer

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Video Borescope Inspection Camera

Digital Humidity Probe, HPL1 (#30009)

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

2440 Wireless SmartCart

MP7. Uninterruptible Power Supply

Standard SureVolt Power Conditioner / Voltage Regulator

Specification of Analog MEMS Microphone

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

HP Photosmart Premium Fax All-in-One Printers (C410a, C410b, C410c, C410d, C410e) - Product Specifications Product Specifications

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Flow. Flow. N/en

ADP Dot Peen Marking Machine

Dell Vostro 460. About Warnings. Setup and Features Information

38mm Slim design, touch screen, and better reliability Graphic panel, GP-S044

FT-01. describes are subject to change without prior notice.

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION

1U Device Expansion Unit Configuration Guide

PLACEMENT SOLUTION RX-6 SERIES. High-Speed Compact Modular Mounter

signotec Delta PD 10.1 LCD Colour Pen Display

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

0.4mm Pitch, Stacking Type Board-to-Board (FPC) Connector WP7 Series. Plug

HMIPWC7D0E01 Panel PC Optimum - Compact Flash - 15'' - DC - Fanless

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Junos WebApp Secure 5.0 Hardware Guide

Review Sheet Chapter 3

Transcription:

Cubus Version 3.2 / May 2017 Configuration Standard Configuration Cubus Machine type Standalone Stacks Flexible stacks for reel storing, adjustable by customer Reel detection Automatic diameter, width and weight detection, automatic barcode detection Control PC, keyboard and LCD Windows version Windows 10 Database Data access via Access table; Connection to existing SQL systems Software Cubus control software Job planning software MSL tracking (Moisture sensitivity level) Bar code label designer and print software Component stock management software Software interface to emis planning and optimization system Adjustable operator language (English, German. Other languages on request) User group rights Other included items Power connection cable Specifications General Regular Large Power requirements 100-240 VAC, 50-60 Hz 100-240 VAC, 50-60 Hz Power consumption 400W 400W Required circuit breaker 10A 10A Environment Storage Temperature Relative humidity Noise level 4-7" reels: 8-72 mm tapes 11-15" reels: 8-72 mm tapes Max. 3.5 kg 15-30 C 10-60% 50dB 4-7" reels: 8-72 mm tapes 11-15" reels: 8-72 mm tapes Max. 3.5 kg Maximum capacity 4-7" reels: 612 or any mix of 4-4-7" reels: 932 or any mix of 4-4- - 121 4- reels: 480 and 11- (8mm tape only) (8mm tape only) Access time 9-11 seconds per reel 9-11 seconds per reel Options Tray Box (*) Option for storing trays: Capacity in Cubus Regular: 73 x Tray Boxes Each containing up to 10 x JEDEC trays (8 mm) Option for storing trays: Capacity in Cubus Large: 110 x Tray Boxes Each containing up to 10 x JEDEC trays (8 mm) (*) Capacity in Cubus Regular: 146 x spindles Capacity in Cubus Large: 220 x spindles (*) Capacity in Cubus Regular: 35 x spindles Capacity in Cubus Large: 54 x spindles Support plate Handling of reels which do not comply specifications, like extremely bended reels or reels with weak material. Each support plate can handle only one reel, no stacking possible. (*) Not available with Remote Service software option Essemtec AG - Phone: +41 (0)4

Machine Dimensions and Packaging General Regular Large Machine Dimensions 1140x110x2504 mm (w x d x h) 1591x1100x2504 mm (w x d x h) Machine Weight 500 kg (without reels) 700 kg (without reels) Packaging Dimension Wooden crate / cardboard Entire wooden crate Packaging Weight Wooden crate / cardboard Entire wooden crate Total Weight Wooden crate / cardboard Entire wooden crate 1350 x 1500 x 2700 mm (w x d x h) 1350 x 1550 x 2800 mm (w x d x h) 130 kg 220 kg 630 kg 720 kg 1800 x 1500 x 2700 mm (w x d x h) 1800 x 1550 x 2800 mm (w x d x h) 180 kg 280 kg 880 kg 980 kg Dimension Drawings Page 2 of 6

Cubus Air Dryer / Required Air Quality (Cu-Dry)* General Compressed air Min. Compressed air flow Typical Compressed air consumption Air connection diameter Required Air Quality Class 1 Particulate Class 2 Water Class 1 Oil 6 bar-10 bar 18m 3 /h@6bar With air flow limiter: 12m 3 /h@6bar Without air flow limiter: 18m 3 /h@6bar Nominal approx. 6m 3 /h** 8mm In each cubic meter of compressed air, the particulate count should not exceed 20,000 particles in the 0.1-0.5 micron size range, 400 particles in the 0.5-1 micron size range and 10 particles in the 1-5 micron size range. A pressure dew point (PDP) of -40 C or better is required. No liquid water is allowed. In each cubic meter of compressed air, not more than 0.01mg of oil is allowed. This is a total level for liquid oil, oil aerosol and oil vapor. * Cu-Dry is designed to maintain humidity inside the Cubus and must not be used as a Dry Cabinet ** Depending on the work load and environment estorage PC Requirement Hardware Item Processor Memory Graphic Card Network Card Hard Disk Extensions Software Item: Operating System Database Minimum Requirement Dual Core i3 Processor, 64 bit compatible INTEL or AMD 2 Gigabyte Strongly recommended: 4 Gigabyte DirectX 9.0 support No high end graphic speed needed Recommendation: do not use Nvidia, GUI artefacts might occur Tip: graphic-card can be substituted with in-processor integrated GPU Two network cards required (GB-Link at least): 1x Connection to Cubus 1x Network connection 200 Gigabyte hard disk, SSD preferred One USB Slot for Software Protection Dongle Minimum Requirement: Microsoft Windows 7, 64 Bit version Strongly recommended: Microsoft Windows 10, 64 Bit version A real server installation is recommended Page 3 of 6

Reel Specifications A Nominal diameter [mm] F Distance between two codes [mm] B Reel width [mm] G Barcode height [mm] C Reel bending downwards [mm] H Barcode label width [mm] D Barcode label area [mm] J Barcode label twist [ ] E Barcode label area [mm] K* Reel bending upwards [mm] Reel Dimensions / for 180 mm (7 inches) Reels Tape width [mm] A min [mm] A max [mm] B min [mm] B max [mm] <1000 g >1000 g >2000 g 8 100 178 10.5 14.4 25 30 35 12 18.4 30 35 40 16 22.4 35 40 45 24 30.4 45 45 55 32 38.4 50 50 65 44 50.4 65 65 75 56 62.4 75 75 85 C max [mm] <1000 g C max [mm] >1000 g C max [mm] >2000 g Max Reel weight [g] 2 3 4 3500 K max [mm] <1000 g K max [mm] >1000 g K max [mm] >2000 g Max Reel weight [g] 1 1 1 3500 K* The bending upwards is usually included in the height measurement of the reel. But the bending might be different between the front or back side of the reel, in this case K must not be higher than the mentioned value. Page 4 of 6

Reel Dimensions / for 330/380 mm (13/15 inches) Reels Tape width [mm] A min [mm] A max [mm] B min [mm] B max [mm] <1000 g >1000 g >2000 g 8-381 10.5 14.4 30 35 35 12 18.4 35 40 40 16 29 45 50 50 24 37 55 55 55 32 45 65 65 65 44 57 75 75 75 56 69 85 90 90 72 89 105 110 110 C max [mm] <1000 g C max [mm] >1000 g C max [mm] >2000 g Max Reel weight [g] 6 7 8 3500 K max [mm] <1000 g K max [mm] >1000 g K max [mm] >2000 g Max Reel weight [g] 3 3 3 3500 K* The bending upwards is usually included in the height measurement of the reel. But the bending might be different between the front or back side of the reel, in this case K must not be higher than the mentioned value. Page 5 of 6

Barcode Label Dimensions A Nominal diameter [mm] F Distance between two codes [mm] B Reel width [mm] G Barcode height [mm] C Reel bending [mm] H Barcode label width [mm] D Barcode label area [mm] J Barcode label twist [ ] E Barcode label area [mm] Barcode Label Dimensions Type D max E min F min G min G max H max H min J max Max. number of labels Min. size of square / line 1D 110 30 8 8 100 100 8 35 depends on G 2D 110 30 8 6 22 22 6 Must be placed 0 / 90 180 / 270 4 0.3 mm 4 0.5 mm Note: The system can recognize a maximum of 4 barcode labels. Barcode Label Recommendation White and matt labels are recommended. Other colors or gloss surfaces can impact negatively to the function of the barcode reader or can cause malfunction. For a proper recognition of the barcode, stick it only on a plane surface. Embossed surfaces, recesses, bumps and indentations are not suitable. Within the readable field (D) barcodes side by side (same height) can cause malfunction. Please ask for the System Description or Product Note for further details of available options Disclaimer & Copyright: We reserve the right to make changes without notice. All materials contained in this brochure are copyright Essemtec AG, Switzerland, May 2017 Page 6 of 6