LED MOVING HEAD ZOOM 144W WASH 4in1 RGBW

Similar documents
LED BEAM MOVING HEAD 12x12W Cree, 4in1, beam 8 degree

LED BEAM MOVING HEAD FL x3W User Manual

Snapshot. Data Stream 4 USER MANUAL

DM-X Channel DMX Controller. Item ref: UK User Manual. Version 2.0

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

LED W RGBA User Manual

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

Snapshot. User Manual. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120/230 V switch Replaceable Fuse User-Serviceable

User Manual 4BAR. Snapshot. (Included) Use on Dimmer Outdoor Use. Sound Activated DMX. Master/Slave Autoswitching Power Supply Replaceable Fuse

DMX-4 LED. User Manual

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

DMX-4 Dimmer/Relay Pack

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Snapshot. User Manual

w w w. p r o l i g h t. c o. u k STAGE PAR 64

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

36LEDs Par Light. User Manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave Autoswitching Power Supply Replaceable Fuse.

Fusion Saber. User Manual. Order code: EQLED070

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

TB-1230 QW. User Manual Please read the instruc on carefully before use

Power LED Beam 56 Narrow

StagePar COB TRI 4 CKU

Snapshot. Double Derby X. User Manual

User s manual. Easy Scan XT3 LED

MATRIX 25E. Matrix Beam Wash, ArtNet, RDM. User manual. Please read the instructions carefully before use

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

Quick Reference Guide

SCENE PROGRAMMING (STEPS)

Snapshot. Hurricane 1800 Flex USER MANUAL

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 6 Power Linking... 6 MOUNTING... 7 Orientation... 7 Rigging...

Snapshot. S-MOVER Stage Mover USER MANUAL

Snapshot. LED-PALET COLORpalette USER MANUAL

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

MATRIX LED LED User Manual Please read the instructions carefully before use

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

FLEX BEAM V8. User Manual Please read the instruction carefully before use

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Mover MicroBeam QUAD-W

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

LED Stage Par Light DMX wireless&battery 10-watt x 4 LEDs (R/G/B/A/W 5IN1) User s Manual

VBAR 270. User Manual. Version 1.2

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

order code: EQLED40 user manual

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Crossfire. User Manual. Order code: EQLED061

CP 64 BD15 CP 64 PD15

LIGHT BRICK - 12 X 3W TRI-COLOUR

X-3 LED. Owner s Manual ROBOHEAD

Vortex. User Manual. Order code: EQLED073

Vector Beam White. User Manual. Order code: LEDJ265

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

Snapshot. LED-PALET COLORpalette USER MANUAL

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Snapshot USER MANUAL. MiN Spot

Snapshot. Élan USER MANUAL. OK on Dimmer Outdoor OK. Sound Activated DMX512. Master/Slave. 115V/230V Switch. Replaceable Fuse.

User Manual INTRODUCTION SAFETY INFORMATION BACK PANEL DIAGRAM. Please read the instructions carefully and before use.

Snapshot. Vue 6.1 USER MANUAL

Snapshot. LED Mushroom USER MANUAL

Eternal Lighting. Premier150 Spot. User Manual

Colour Burst Order code: LEDJ01 USER MANUAL

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

COB100/200W 2in1/3in1 led Par Light

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

User Manual Please read the instructions carefully before use

Blitzer Strobe. User Manual. Order code: EQLED366

CW-WW LEDWash USER MANUAL

Quick Reference Guide

Order code: EQLED53 User manual

UV Power Flood. User Manual. Order code: EQLED029

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

IMPACT Order code: EQLED79

Performer 18 RGBWA MKII

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

LED SPIDER MOVING HEAD LIGHT

Order code: EQLED60 USER MANUAL

Snapshot. Kinta X USER MANUAL

Gobo Projector XP 80W

PF LED Profile. User Manual

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

PROFESSIONAL SHOW LIGHT

Snapshot. LED Mushroom. User Manual

Snapshot. Use on Dimmer. Outdoor. Sound Activated DMX. Master/Slave Autoswitching Power Supply External Power Supply Replaceable Fuse

UV Spectra Batten 12 x 5W UV LEDs

Saturn Spot. User Manual. Order code: EQLED023

Transcription:

LED MOVING HEAD ZOOM 144W WASH 4in1 RGBW User Manual www.flash-butrym.pl Page 1

Table of contents 1. Preface 2 1.1 Packing list 2 1.2 Unpacking instructions 2 1.3 AC Power 2 1.4 Safety instructions 2 2. Introduction 3 2.1 Features 3 2.2 DMX channel 3 3. Setup 3 3.1 Fuse replacement 4 3.2 Fixture linking 4 Data cabling 4 DMX data cable 4 3.3 3-Pin to 5-Pin conversion chart 4 3.4 Setting up a DMX serial data link 4 3.5 Master/Slave fixture linking 5 3.6 orientation 5 4. Operating instructions 5 4.1 Navigating the control panel 5 4.2 Menu map 6 4.3 User configurations 6 Setup single-desk light`s autocephaly moving mode(self-motion move) 6 Setup single-desk light`s autocephaly moving mode(sound control) 6 Master/slave mode(master sound,master auto) 6 To set the pan to reverse or non-inverting 6 To set the tilt to reverse or non-inverting 7 To set the LED readout to inverting or non-inverting 7 resume reverse windows default 7 DMX mode 7 4.4 DMX channel values 7 5. Technical specifications 8

1. Preface 1.1 Packing list Product name Mini Moving Head Light Unser Manual quantity 1 pcs 1pcs 1.2 Unpacking instructions On receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are presented, and have been received in a good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows, sign of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. 1.3 AC Power To determin the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixtures specifications chart. A fixture listed current rating is its average current draw under normal conditions. All fixtures must be directly powered off a switched circuit and cannot be run off a rheostat(variable resisto) or dimmer circuit, even if the rheostat or dimmer source voltage matches the fixtures requirement. Check the fixture or device carefully to make sure that if a voltage selection switch exists that it sets to the correct line voltage you will use. Warning! Verify that the voltage select switch on your unit matches the line voltage applied. Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch. All fixtures must be connected to circuits with a suitable Earth ground. 1.4 Safety instructions Pleese read these instructions cy, it includes important information about the installation, usage and maintenance of this product. Please keep this user guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connection to is not higher than that stated on the decal or rear panel of the fixture. This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure that there are no flammable materials close to the unit while operation. The unit must be installed in a location with adequate ventilation, at least 20in(51cm) from adjacent surfaces. Be sure that no ventilation slots are blocked. Always disconnect from power source before servicing or replacing fuse and be sure to be replaced with same fuse,size and type. Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles.

Maximum ambient temperature (Ta) is 104 (40 ). Do not operate fixture at temperature higher than this. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people will lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Don t connect the device to a dimmer device. Make sure the power cord never crimped or damaged. Never disconnect the power cord by pulling the cord. Avoid directing eye exposure to the light source while it is on. 2. Introduction 2.1 Features 12 channel DMX-512. Pan :630 /tilt:270. Variable electronic strobe. Variable electronic dimmer(0-100%). LED display menu with invert. Reset to factory settings option. Pan/tilt invert option. Fan cooled. 2.2 DMX Channel 3. Setup Channel Function 1 Pan 2 Tilt 3 Pan/Tilt Speed 4 Red 5 Green 6 Blue 7 White 8 Mix color 9 Strobe and Reset 10 Dimmer 11 ZOOM 12 Pan Fine 13 Tilt Fine Disconnect the power cord before replacing a fuse and always replace with the same type fuse. 3.1 Fuse replacement With a flat head screwdriver wedge the fuse hold out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power. 3.2 Fixture linking You will need a serial data link to run light show of one or more fixtures using a DMX-512 controller or to run synchronized on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the

fixtures on a serial data link determines the number of fixtures the data link can support. Maximum recommended serial data link distance:500 meters(1640ft). Maximum recommended number of fixtures on a serial data link:32 fixtures. Data cabling To link fixtures together you must obtain data cables. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference. DMX data cable Use a belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following character: 2-conductor twisted pair plus a shield. maximum capacitance between conductors-30 pf/ft. maximum capacitance between conductor and shield -55 pf/ft. maximum resistance of 20 ohms/1000ft. nominal impedance 100~140 ohms. 3.3 3-Pin to 5-Pin conversion chart Note! If you use a controller with a 5 pin DMX output connector. you will need to use a 5pin to 3 pin adapter CHAUVET Model No:DMX5M. ordmx 5F The chart below details a proper cable conversion: 3.4 Setting up a DMX serial data link At first, link the first light and DMX control through XLR-connection signal cable then devolute the light in series,as follows: 3.5 Master/Slave fixture linking 1.Connect the (male) 3 pin connector side of the DMX cable to the output (female)3pin connector of the first fixture. 2.Connect the end of the cable coming from the first fixture which will have a (female)3 pin connector to the input connector of the next fixture consisting of a (male)

3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. 3.6 orientation This fixture may be mounted in any position provided there is adequate room for ventilation. 4. Operating instructions 4.1 Navigating the control panel Access control panel functions using the four panel buttons located directly under the LCD Display. Button Used to access the menu or return to a previous <MENU> menu option. Scrolls through menu options in descending <DOWN> order. <UP> Scrolls through menu options in ascending order. Used to select and store the current menu or <ENTER> option within a menu.. When a menu function is selected, the display will show immediately the first available option for the selected menu function. To select a menu item, press<enter>. Press the <MENU> button repeatedly until you reach the desired menu function. Use the <UP> and <DOWN> buttons to navigate the menu options. Press the <ENTER> button to select the menu function currently displayed, or to enable a menu option. To return to the previous option or menu without changing the value, press the <MENU> button. No alteratived worth that return re-option or menu, press(menu)button 4.2 Menu map RPON (address code setting from A001-------A512) AU01(auto-moving speediness) SN01(Sound control for color changing) RPOF(Set pan to forward-rotating) RTOF(Set tilt to forward-rotating) RDOF(set the LED readout to non-inverting) DFON (Default output setting) Function AU02(slow speed auto-moving) SN02( Sound control for strobe) RPON(Set pan circumrotate reverse) RTON(Set tilt circumrotate reverse) RDON(Set the LED readout to inverting) Note:output default setting address code is A001, pan is positive circumrotate tilt is positive circumrotate LED positively reveal. 4.3 User configurations Setup single-desk light`s autocephaly moving mode(auto-running).press the MENU until it shows AU01

.Use the UP/DOWN buttons to set to AU01 or AU02,Press ENTER to confirm. Setup single-desk light`s autocephaly moving mode(sound control).press the MENU button until it shows SNOF..Use the UP/DOWN buttons to set to SNOF,press ENTER to confirm. Master/slave mode(auto-running sound control).this mode will allow you to link up 32 units together without a controller..use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the units.proper performance it may be necessary to use a terminator at the last fixture. For more information about terminators.. Set the desired master-mode- Automatic program mode or sound controlled mode, for the master-device, send the DMX address 1 for all slave-devices. Please refer to the instruction under control board. To set the pan to reverse.press the MENU until it shows RPOF..Use the UP/DOWN buttons show RPON, press ENTER to confirm. To set the tilt to reverse.press the MENU until it shows RTOF.Use the UP/DOWN buttons show RTON, press ENTER to confirm. To set the LED readout to 180,rotating.Press the MENU until it shows RDOF..Use the UP/DOWN buttons show RDON, press ENTER to confirm. Resume reverse Windows default.press the MENU until it shows DFON..press ENTER to confirm DMX mode This mode allows the unit to be controlled by any universal DMX controller. The default mode for the fixture is DMX, as follows 4.4 DMX channel values Channel Value Function Pan 1 0-255 Pan movement 2 Tilt

3 4 5 6 7 8 9 0-255 Tilt movement Pan/Tilt Speed 0-255 Pan/Tilt Speed Red 0-255 0-100% Red Green 0-255 0-100% Green Blue 0-255 0-100% Blue Amber 0-255 0-100% Amber Mixed Color No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 No function 0-2 3-41 42-83 84-125 126-167 168-209 210-251 252-255 0-10 11-20 21-30 31-200 201-250 251-255 Strobe and Reset LED off LED on Reset Strobe-effect with increasing speed Random strobe-effect with increasing spped LED on Dimmer 0-100% dimme 10 0-255 11 0-255 zoom 12 Pan Fine 0-255 Pan fine 13 Tilt Fine 0-255 Tilt fine 5. Technic data Voltage Fuse Lamp resource Pan Tilt Tiptop environment temperature Date input/output Product size N.W Packing size G.W (1pc) 230V 50Hz 5A,Ф5 20mm, 12pcs 12w LED 630,16bit fine 270,16bit fine 104 F(40 C) 3pin XLR-connection anlde socket 260 260 350mm(L W H) 5.7kg 645 360 405mm(L W H)(2pcs/package) 6.6kg