V-Cone Metering Program

Similar documents
MI-2667 Annubar Flow Calculation Program

ISO5167 Flow Calculation Program

V-Cone Metering Program (for the ROC800-Series) User Manual

V-Cone Metering Program User Manual (for ROC800-Series)

GOST Flow Calculation Program

Annubar Flow Calculation Software (for FloBoss 107 Flow Managers) User Manual

ULTRASONIC SERIAL I/O INTERFACE

FOUNDATION Fieldbus Interface Software (for the ROC800-Series) User Manual

AUTO-ADJUST TURBO-METER PROGRAM (For ROC300-Series and FloBoss 407) User Manual

Equimeter Auto-Adjust Program (For FloBoss 107 Flow Managers) User Manual

ROC Plus Protocol. Specification Manual. Form A6127. Flow Computer Division. Part Number D301180X0012 January 2007

STEAM/WATER THERMODYNAMICS APPLICATION PROGRAM User Manual

ROC800L Field Conversion Guide

Gas Control Manager Program User Manual (for FloBoss 107)

DS800 Development Suite Quick Start Guide for the FloBoss 107

FloBoss 103 and 104 Firmware

Gas Chromatograph Software Interface User Manual (for FloBoss 107)

ROCLINK 800 Configuration Software

FloBoss 107 Firmware. Operating System. Remote Automation Solutions. D301235X012 October 2013

Dynamic Flow Computers, Inc Southwest Freeway, Suite 320 Stafford, TX Ph: (281) Fax: (281)

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98

ControlWave Micro HART / BTI Interface Module

FloBoss 107 Flow Manager Instruction Manual

Emerson Process ROC Protocol Enhanced Master Driver v3.0

Hawk Alarms and Sensor Error Codes

Installing ValveLink DTM Software

Fisher ROC Serial Driver Help Kepware Technologies

DS800 Development Suite Quick Start Guide for the ROC800-Series

AMS ValveLink Software Quick-Start Guide

DS800 Development Suite Quick Start Guide for the FloBoss 107

ASCII Read Driver Programmable Serial Interface Card Series 1

Robert Shaw Reeltape Model 185A Programmable Serial Interface Card Series 2

FLOBOSS 103 AND 104 FLOW MANAGERS

Converting a Router DTM Installation to

Enron Modbus Protocol

Barcode (ASCII Read) Driver for DeltaV Programmable Serial Interface Card

GAS CHROMATOGRAPH USER PROGRAM (For ROC809) User Manual

ROCLINK 800 Configuration Software User Manual (for FloBoss 107)

Tank Manager User Manual (for ROC800-Series and FloBoss 107 Controllers)

ASCII Printer Driver Programmable Serial Interface Card Series 2

ABB Gas Chromatograph 3100 Programmable Serial Interface Card Series 2

March 21, Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series. ROC 300 and 407 Customers,

American Central Modbus Protocol

Limitorque DDC-100 Programmable Serial Interface Card Series 2

Barcode (ASCII Read) Driver for DeltaV Programmable Serial Interface Card Series 2

ScannerCal Accuracy Verification System for the FlowScanner

Enron Modbus I/O Driver (Series 2) Programmable Serial Interface Card

FloBoss 107 ROCNOC User Manual

Foundation Fieldbus Flow Computer

Virtual RS3 I/O Driver For Series 2 Simplex Programmable Serial Interface Card

Totalflow Modbus Protocol

Fox Thermal Instruments, Inc.

FloBoss TM 107/107E Flow Manager Overview

Totalflow Modbus Protocol

Programmable Serial Interface Card Driver Bell-Ennium 7785-P2005 Magnetic Plate Stirrer

Rice Lake Weigh Scale Application Programmable Serial Interface Card

Totalflow PG&E Protocol

Programmable Serial Interface Card Driver Advanced Instruments 3250

MSA AUER M-292 Programmable Serial Interface Card Series 2

Square D Sy/Max Driver Programmable Serial Interface Card

Foxboro HTG Driver Programmable Serial Interface Card Series 2

Software for Gas Chromatographs. Applies to Both: Daniel Danalyzer On-Line Gas Chromatographs Rosemount Analytical Process Gas Chromatographs

We Serve the Customer First. Spartan Pocket FloBoss User s Manual Document Version 2.0. Grande Prairie Av

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

Rotork Pakscan Driver for DeltaV Programmable Serial Interface Card

TI NITP Driver Programmable Serial Interface Card

Rosemount 1595 Conditioning Orifice Plate

Optichrom 2100 Programmable Serial Interface Card Series 2

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

ROC Protocol Specifications Manual (for Emerson FB1000 and FB2000 Series Flow Computers)

Foxboro 762C/743CB Controllers Programmable Serial Interface Card

Fox Thermal Instruments, Inc.

ENRON MODBUS PROTOCOL. For. CB181 FCUs (2)

Baumann Little Scotty Bronze Control Valve

Gas Chromatograph Interface Program User Manual (for ROC800-Series Remote Operations Controllers)

ROC800L - Liquid Flow Measurement Computer Measurement and Control for Hydrocarbon and Petrochemical Liquids

Liquid and Gas Ultrasonic Flowmeters Smith Meter Ultra 4c, 6c, and 8c MPU 200c, 600c, 800c, and 1600c

OpenEnterprise Licensing User Manual

Purpose of Today s Presentation

Draeger Polytron IR 334 Programmable Serial Interface Card Series 2

ControlWave Micro HART / BTI Interface Module

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

Tutorial 1. Introduction to Using FLUENT: Fluid Flow and Heat Transfer in a Mixing Elbow

FREQUENTLY ASKED QUESTIONS

FloBoss 103 Flow Manager

Cause and Effect User Manual (ROC800)

ControlWave Micro Analog Input / Output Modules

Installation and Operating Manual FM50 IOM 2-18 DRAFT

Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual

MODBUS MESSAGE PROTOCOL FOR MODEL FT2 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER

Integrate Symantec Messaging Gateway. EventTracker v9.x and above

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Rosemount 1595 Conditioning Orifice Plate

Dattus can communicate via Modbus RTU protocol. It is designed to be compatible with SCADA and other equipment that communicates via Modbus

Fisher FIELDVUE DVC6200 HW2 Management of Change Guide

YSI 2700 SELECT Programmable Serial Interface Card Series 2

ISO 5389 INTERNATIONAL STANDARD. Turbocompressors Performance test code. Turbocompresseurs Code d'essais des performances. Second edition

ADSP EZ-ICE Emulator User s Guide (For Use with VisualDSP++ Release 2.0 or Higher)

Transcription:

Flow Computer Division V-Cone Metering Program (For the FloBoss 103) User Manual (QER 03Q022) Form A6147 December 2005

Revision Tracking Sheet December 2005 This manual may be revised periodically to incorporate new or updated information. The revision date of each page appears at the bottom of the page opposite the page number. A change in revision date to any page also changes the date of the manual that appears on the front cover. Listed below is the revision date of each page (if applicable): Page All pages All pages Revision Dec-05 Jul-03 FloBoss and ROCLINK are marks of one of the Emerson Process Management companies. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. Fisher Controls International, LLC. 2000-2005. All rights reserved. Printed in the U.S.A. www.emersonprocess.com/flow While this information is presented in good faith and believed to be accurate, Fisher Controls does not guarantee satisfactory results from reliance upon such information. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding the performance, merchantability, fitness or any other matter with respect to the products, nor as a recommendation to use any product or process in conflict with any patent. Fisher Controls reserves the right, without notice, to alter or improve the designs or specifications of the products described herein. Revised Dec-05 ii

Table of Contents Page 1 INTRODUCTION... 1 1.1 Scope and Organization... 1 1.2 Product Overview... 1 1.2.1 V-Cone Flow Calculations... 2 1.3 Program Requirements... 2 2 INSTALLATION... 3 2.1 Downloading the Program... 3 3 CONFIGURATION... 7 3.1 Device Information Screen... 7 3.2 Meter Setup Screen General Tab... 8 3.3 Meter Setup Screen Inputs Tab...9 3.4 Meter Setup Screen Gas Quality Tab... 10 3.5 Meter Setup Screen Advanced Tab... 11 3.6 V-Cone Setup Screen... 12 3.7 Saving the Configuration... 16 Revised Dec-05 iii

1 INTRODUCTION 1.1 Scope and Organization This document serves as the user manual for the V-Cone Metering User Program (QER 03Q022), which is intended for use in a FloBoss 103. This manual describes how to download and configure this program (referred to as the V-Cone program or the program throughout the rest of this manual). You access and configure this program using ROCLINK 800 Configuration Software (version 1.60 or greater) loaded on an IBM-compatible personal computer running Windows 98, ME, NT 4.0 (with Service Pack 6), 2000 (with Service Pack 2), or XP. The sections in this manual provide information in a sequence appropriate for first-time users. Once you become familiar with the procedures and the software running in a FloBoss 103, the manual becomes a reference tool. This manual has the following major sections: Section 1 Introduction Section 2 Installation Section 3 Configuration This manual assumes that you are familiar with the FloBoss unit and its configuration. For more information, refer to the FloBoss 103 Flow Manager Instruction Manual (Form A6114) or the ROCLINK 800 Configuration Software User Manual (Form A6121). 1.2 Product Overview The program allows a FloBoss 103 to calculate flow rates, integrate volumes, and create historical values when the differential input (MVS) for a gas flow calculation comes from a McCrometer V-Cone meter rather than an orifice plate. Gas compressibility calculations are implemented using FloBoss firmware and AGA8 1992 standards. The FloBoss 103 reads flow inputs (differential pressure, temperature, and static pressure) and calculates an instantaneous rate once every second. Also, at a user-configured scan period it performs an AGA8 1992 calculation (or other properties calculation), followed by volume integration. The program is designed for the composition ranges and fluids of natural gas and other related hydrocarbons, as defined in AGA Report #8, 1992 editions. The program itself does not perform gas or fluid property calculations. Instead, it obtains gas properties either from FloBoss firmware (using AGA8 1992 standards) or from a separate user program installed in the FloBoss. The 03Q022 components are: A McCrometer V-Cone Meter that outputs an analog differential pressure signal. The V-Cone Metering user program that loads into FloBoss memory to provide support for the McCrometer V-Cone flow calculations. This manual. Revised Dec-05 1

1.2.1 V-Cone Flow Calculation The V-Cone Flow calculation provides an instantaneous flow rate that is adjusted to contract pressure and temperature, which you can define using the application-specific V-Cone screen. Note: For further information on V-Cone calculations, equations, and flowcharts, refer to the publications library on the McCrometer website (www.mccrometer.com). 1.3 Program Requirements You download the V-Cone Metering program to and then run it from the Flash and RAM memory on the FloBoss 103. The V-Cone program is compatible only with firmware version 2.12 (or greater) of the FloBoss 103. Download and configure the program using the ROCLINK 800 Configuration software (version 1.60 or greater). The downloadable program is: File Name Unit Task Code Space Data Space UDP FB103VC1.BIN FloBoss 103 User 1 790000 79FFFF 46C000 46CFFF 22 Note: You must connect a PC to the FloBoss unit s LOI port before starting the download. For information on viewing the memory allocation of user programs, refer to the ROCLINK 800 Configuration Software User Manual (Form A6121). Revised Dec-05 2

2 INSTALLATION This section provides instructions for installing the V-Cone Metering program into FloBoss memory. Read Section 1.3 of this manual for program requirements. 2.1 Downloading the Program This section provides instructions for installing the user program into FloBoss memory. To download the user program using ROCLINK 800 software: 1. Connect the FloBoss to your computer using the LOI port. 2. Start and logon to ROCLINK 800. 3. Select ROC > Direct Connect to connect to the FloBoss unit. 4. Select Utilities > User Program Administrator from the ROCLINK menu bar. The User Program Administrator screen displays (see Figure 1): Figure 1. User Program Administrator 5. Click Browse in the Download User Program File frame. The Select User Program File screen displays (see Figure 2). 6. Select the path and user program file to download from the CD-ROM. (Program files are typically located in the Program Files folder on the CD-ROM). As Figure 2 shows, the screen lists all valid user program files with the.bin extension: Revised Dec-05 3

Figure 2. Select User Program File 7. Click Open to select the program file. The User Program Administrator screen displays. As shown in Figure 3, note that the Download User Program File frame identifies the selected program and that the Download & Start button is active: Figure 3. User Program Administrator Revised Dec-05 4

8. Click Download & Start to begin loading the selected programs. The following message displays: Figure 4. Confirm Download 9. Click Yes to begin the download. During the download, the program performs a Warm Start, creates an event in the Event Log, and when the download completes displays the following message: Figure 5. ROCLINK 800 Download Confirmation 10. Click OK. The User Program Administrator screen displays (see Figure 6). Note that: The User Programs Installed in Device frame identifies the loaded program. The Status field in that frame shows the device status as ON (indicating a successful Warm Start). The Memory Usage frame indicates the memory the program uses. Revised Dec-05 5

Figure 6. User Program Administrator 11. Click Close. The ROCLINK 800 screen displays and the download is complete. Figure 7. ROCLINK 800 Revised Dec-05 6

3 CONFIGURATION After you have loaded the V-Cone Metering program, you configure it using the ROCLINK 800 software. To do this, you use two standard ROCLINK 800 screens (Device Information and Meter Setup) and a program-specific screen (V-Cone Setup): Use the Device Information screen to select U.S. or Metric engineering units. Use the General, Inputs, Gas Quality, and Advanced tabs on the Meter Setup screen to set general parameters. Use the V-Cone Setup screen to set the program-specific parameters. 3.1 Device Information Screen Use this screen to check the default units. 1. From the ROCLINK 800 screen, select ROC > Information. The Device Information screen displays. Figure 8. Device Information 2. Review and change as necessary the value in the following field: Field Units Description 3. Click Apply if you changed the value in this field. 4. Click OK to return to the ROCLINK 800 screen. Sets the engineering units the program uses. US or Metric are valid options for this program. Revised Dec-05 7

3.2 Meter Setup Screen General Tab Use the General tab on the Meter Setup screen to define the meter type, calculation standard, and values for the pipe and orifice diameters. 1. From the ROCLINK 800 screen, select Meter > Setup. The Meter Setup screen displays. 2. Select the General tab. Figure 9. Meter Setup General Tab 3. Assure that the Orifice and 1992 AGA3 radio buttons are clicked and complete the Pipe Diameter and Orifice Diameter fields. The Orifice Diameter field indicates the diameter of the V-Cone Meter. Review the remainder of the screen to make sure that the values correspond to your organization s requirements. Note: The Low Flow Cutoff field defines the differential pressure at which the program assumes no valid flow is present and sets the instantaneous flow rate to zero. The Integral Multiplier Period (imp) field defines the period (in minutes) at which the program performs the AGA8 gas property calculations and integrates volumes. Valid values are from 1 to 60. 4. Click Apply to save any changes. Go to Section 3.3. Revised Dec-05 8

3.3 Meter Setup Screen Inputs Tab Use the Inputs tab on the Meter Setup screen to identify the I/O definitions and values for differential pressure, static pressure, and temperature. 1. From the Meter Setup screen, select the Inputs tab. Figure 10. Meter Setup Inputs Tab 2. Complete the Differential Pressure, Static Pressure, and Temperature definitions and values. Review the rest of the screen to make sure that the values correspond to your organization s requirements. 3. Click Apply to save any changes. Go to Section 3.4. Revised Dec-05 9

3.4 Meter Setup Screen Gas Quality Tab Use the Gas Quality tab on the Meter Setup screen to define gas composition. 1. From the Meter Setup screen, select the Gas Quality tab. Figure 11. Meter Setup Gas Quality Tab 2. Review the values on this screen to make sure that they correspond to your organization s requirements. 3. Click Apply to save any changes. Go to Section 3.5. Revised Dec-05 10

3.5 Meter Setup Screen Advanced Tab Use the Advanced tab on the Meter Setup screen to set base pressure and base temperature. 1. From the Meter Setup screen, select the Advanced tab. Figure 12. Meter Setup Advanced Tab 2. Review any values you enter especially for Base Pressure and Base Temperature on this screen to make sure that they correspond to your organization s requirements. 3. Click Apply to save any changes. Go to Section 3.6. Revised Dec-05 11

3.6 V-Cone Setup Screen The V-Cone Setup screen enables you to enter program-specific configuration parameters and displays calculated values. To access this screen: 1. Click Meter > V-Cone Setup from the ROCLINK configuration menu: Figure 13. ROCLINK 800 2. The V-Cone Setup screen displays (see Figure 14): Revised Dec-05 12

Figure 14. V-Cone Setup 3. Complete the screen fields based on your organization s requirements. Field Description Tag A 10-character description that uniquely identifies the meter run. Run Status Export to Soft Point Selects the flow calculation for the meter run. Select Enabled to execute the V-Cone flow calculation or select Disabled to use the AGA3 flow calculation. Enables a host to access data from a softpoint if it cannot access the data through other means. Valid values are 0 (disable the access) or 1 through 16 (enable the access and indicate the softpoint to use): 1 Instantaneous Flow Rate (MCF/Day or km3/day) 2 Instantaneous Energy Rate (MMBTU/ Day or GJ/Day) 3 Accumulated Flow Today (MCF or km3) 4 Accumulated Energy Today (MMBTU or GJ) 5 Accumulated Flow Yesterday (MCF or km3) 6 Accumulated Energy Yesterday (MMBTU or GJ) 7 Equivalent HWPF 8 Equivalent Cprime 9 Calculation Period (Seconds) 10 Beta 11 Velocity of Approach 12 Reynolds Number Revised Dec-05 13

Field Export to Soft Point (cont.) V-Cone Correction Factor Instantaneous Flow Instantaneous Energy Flow Today Energy Today Flow Yesterday Energy Yesterday Sample Time Equivalent HWPF C Prime Beta Velocity of Approach Factor Reynolds Number Description 13 Pressure Loss 14 Expansion Factor 15 Linear Gas Velocity 16 Correction to Contract Conditions 17 Thermal Correction Factor Sets the meter correction factor (sometimes referred to as the meter coefficient). This value is typically provided by the meter supplier in the form of a data sheet or calibration sheet for each individual meter. This read-only field shows the calculated volumetric flow rate in MCF/Day or km 3 /Day This read-only field shows the calculated energy rate in MMBTU/Day GJoules/Day. This read-only field shows the accumulated volumetric flow in the current contract day in MCF or km 3. This read-only field shows the accumulated energy in the current contract day in MMBTU or GJoules. This read-only field shows volumetric flow accumulated in the previous contract day in MCF or km 3. This read-only field shows the accumulated energy in the previous contract day in MMBTU or GJoules. This read-only field shows the current rate calculation period, in seconds. Note: This value should always be 1.0 during normal operation. A value greater than 1.0 may indicate the unit is overloaded. This read-only field shows the value of HwPf if the AGA3 flow calculation is active (V-Cone calculation not enabled). The equivalent value for HwPf is shown when the V-Cone calculation is enabled. V-Cone formula: HwPf = Y * Sqrt ( DP psf / DensFlow ), Y being the expansion factor. This read-only field shows the value of C Prime if the AGA3 flow calculation is active (V-Cone calculation not enabled). The equivalent value for C Prime is shown when the V-Cone calculation is enabled. V-Cone formula: C Prime = C acfs x 86.4 (for C acfs description see V-Cone documentation, 86.4 factor translates cft/sec to MCF/Day ) This read-only field shows the diameter ratio as calculated by the AGA3 equation or V-Cone equation. V-Cone Formula: Beta = Sqrt (1-d 2 /D 2 ), (both diameters at Tf) for V-Cone calculations This read-only field shows the calculated velocity of approach factor. V-Cone Formula: Velocity of Approach = 1 / sqrt (1 Beta 4 ) This read-only field shows the calculated Reynolds Number for the active calculation (AGA3 or V-Cone). V-Cone Formula: Reynolds = 123.9 x velocity (ft/sec) x D (inches at Tf) x Density (lbm/cft) / viscosity (cp) Revised Dec-05 14

Field Pressure Loss Expansion Factor Linear Gas Velocity Corr to Contract Conditions Thermal Correction Qacfs Gas Properties Calculation Method Help Description This read-only field shows the pressure loss in % of Upstream Static Pressure. The program forces this value to zero when the V-Cone calculation is disabled. This read-only field shows the calculated expansion factor for the active calculation (AGA3 or V-Cone). V-Cone Formula: Refer to V-Cone equipment documentation for details on the expansion factor equation. This read-only field shows the calculated Linear gas velocity in ft/sec or m/sec. The program forces this value to zero when the V-Cone calculation is disabled. V-Cone Formula: Velocity = 4 x Qacfs (cft/sec) / ( Pi x D 2 (at Tf) ), Qacfs being the uncorrected flow. This read-only field shows the calculated correction to contract conditions based on the V-Cone equation. The program forces this value to zero when the V-Cone calculation is disabled. V-Cone Formula: Correction = ( P L / P b ) x ( T b / T L ) x ( Z b / Z L ). The b subscript refers to contract conditions while L subscript refers to flow/line conditions. This read-only field shows the calculated thermal correction factor. The program forces this value to zero when the V-Cone calculation is disabled. This read-only field shows the uncorrected flow rate in Actual Cubic Feet/Second. The program forces this value to zero when the V-Cone calculation is disabled. This read-only field shows the gas or fluid properties calculation used to calculate and provide gas compressibility, density, and heating value. Note: For gas volume calculations, this field may show AGA8 1992 Detailed if the FloBoss 103 internal AGA8 properties calculation is active. If a separate gas properties user program is active in the unit, the field displays the name of the standards calculation implemented in that program. None displays in the field when no valid properties user program is active in the unit. This read-only field displays the URL location for an electronic copy of this user manual. 4. Click Apply to save any changes you have made to this screen. 5. Click OK to close this screen. This completes the process of configuring the V-Cone program. Proceed to Section 3.7 to save your configuration. Revised Dec-05 15

3.7 Saving the Configuration Whenever you modify or change the configuration, save the final configuration to memory. To save the configuration: 1. Select ROC > Flags. The Flags screen displays: Figure 15. Flags 2. Click Save Configuration. A verification message displays: Figure 16. Save Verification Revised Dec-05 16

3. Click Yes. When the save process completes, a confirmation message displays: Figure 17. Confirmation Note: Depending on the size and complexity of the user program, this process may take several minutes. When the process ends, the Status field on the Flags screen displays Completed. 4. Click Update on the Flags screen. This completes the process of saving your new configuration. Revised Dec-05 17

If you have comments or questions regarding this manual, please direct them to your local sales representative or contact: Emerson Process Management Flow Computer Division Marshalltown, Iowa 50158 USA Houston, TX 77065 USA Pickering, North Yorkshire UK Y018 7JA Website: www.emersonprocess.com/flow Revised Dec-05 18