LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Similar documents
LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

USER S GUIDE. PCI Express to 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters. August 2006 Version 1.0

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

USER S GUIDE. 3 Gbit/s Serial Attached SCSI Host Adapters

MegaRAID SAS e RAID Controller

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Intel RAID Controller RS3FC044 User Guide. Intel Order Number: H

Intel RAID Expander Card RES3FV288 Hardware User's Guide. Intel Order Number: H

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide

Ultra320 SCSI Host Adapters Version 2.2 April 2004

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide

Emulex LPe35000-Series Host Bus Adapters. Installation Guide Release 12.0

Intel RAID Controller RS3UC080J

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

1U Device Expansion Unit Configuration Guide

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

MegaRAID CacheVault Power Module 02

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

SAS JBOD Installation Reference Guide Revision 1.0

Manual. esata PCI Card 1+1. english.

ServeRAID-BR10i SAS/SATA Controller and IBM 3Gb SAS HBA v2 - New family of RAID controllers for System x servers

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

MegaRAID CacheVault Flash Module 02

Dell Host Bus Adaptor User s Guide

DP SATA 6Gb/s 2-Port PCIe

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

Overview. Icon Descriptions. Acknowledgement. Intel, Pentium and Celeron are registered trademarks of Intel Corp.

SGI InfiniteStorage 120

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

NEC Express5800/R120e-1M System Configuration Guide

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

USB 3.1 PCI Express 2-Port 10 Gbps Usb 3.1 Gen 2 Type-C + Type-A

Syncro CS e Controller

Introducing the esata II-150 PCI

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2014

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide

esata II PCIe i/e Quick Installation Guide

Hardware Announcement October 3, 2006

Connecting the Arcserve UDP Appliance Expansion Shelf to the UDP Appliance Server

DNS-2608 Enterprise JBOD Enclosure User Manual

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4450GTX-HT- PWR+

Intel IP Network Server NSI2U

IBM United States Hardware Announcement , dated September 11, 2013

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

CSM200 Expansion Tray

Dell EMC Host Bus Adapter User's Guide

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

MegaRAID SAS i and SAS i RAID Controllers

Acer AT110 F2 Specifications

Specification. Tesla S870 GPU Computing System. March 13, 2008 SP _v00b

IBM ServeRAID M-Series products offer enterpriseclass RAID solutions to enhance server storage and enable use of both SAS and SATA media

CyberSerial Dual PCIe-DB Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide

NEC Express5800/R120d-2M Configuration Guide

P3AM ENZ0. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. Operation Guide (Basic)

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

2-Port Gigabit Ethernet PCIe Card

esata II PCIe i/e Quick Installation Guide

Emulex and QLogic 8 Gb Fibre Channel Host Bus Adapters for IBM System x deliver robustness, ease of management, and high performance

DP SATA 6Gb/s 2S1P PCIe Installation Guide

Dolphin DXE410 Expansion Chassis

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

TRC-190 User s Manual

Upgrading Memory in Cisco 800 Series Routers

NEC Express5800/R120e-2E Configuration Guide

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

ewon Flexy PSTN Extension Card FLA 3501

User s Manual USB 3.0 Expansion Card TS-PDU3

IBM ServeRAID-BR10il SAS/SATA Controller offers a high performance SAS and SATA host bus adapter for direct attach storage

ewon Flexy 2 Serial Ports Ext. Card FLA 3301

16-SLOT IN-BAND MANAGEMENT CHASSIS

SUN SERVER X2-4 SYSTEM

MegaRAID 320 Storage Adapters

DP 1-Port ECP/EPP Parallel PCIe Quick Installation Guide

User s Guide. for Echo Express SE II Thunderbolt 2-to-PCI Express Card Expansion Chassis. For Windows

Intel Desktop Boards D845HV and D845WN Quick Reference

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

CSU 0111 Compute Sled Unit

Serial ATA PCI. Quick Installation Guide. Introducing the Serial ATA PCI. Features and Benefits. System Requirements

QuickSpecs. Models. HP NC510C PCIe 10 Gigabit Server Adapter. Overview

Altos T310 F3 Specifications

User s Guide. for Echo Express and Echo Express Pro Thunderbolt Expansion Chassis for PCIe Cards

Dolphin DXE410 Expansion Chassis

Transcription:

LSI SAS 9300-8e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.3 DB15-000902-03

For a comprehensive list of changes to this document, see the Revision History. Corporate Headquarters Email Website San Jose, CA globalsupport.pdl@avagotech.com www.lsi.com Avago,, the A logo, LSI, Storage by LSI, and Fusion-MPT are trademarks of in the United States and other countries. All other brand and product names may be trademarks of their respective companies. Data subject to change. Copyright 2013 2015. All Rights Reserved.

Overview LSI SAS 9300-8e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide 1 Overview The LSI PCI Express (PCIe )-to-serial Attached SCSI (SAS) host bus adapter (HBA), referred to as the LSI 12Gb/s SAS HBA, provides high-performance external storage connectivity for servers and workstations. The LSI 12Gb/s SAS HBA provides eight lanes of 12Gb/s SAS connectivity and is matched with eight lanes of PCIe 3.0 8Gb/s performance. The low-profile design of the SAS HBA includes a full-height bracket and low-profile mounting bracket that create a universal fit for any server. The LSI 12Gb/s SAS HBA is based on the Fusion-MPT -architected LSI SAS 3008 controller that integrates the latest enhancements in PCIe 3.0 technology and 12Gb/s SAS technology. The LSI 12Gb/s SAS HBA has onboard Flash memory for the firmware. 2 Features This section lists the LSI 12Gb/s SAS HBA features. Implements LSI SAS 3008 eight-port 12Gb/s SAS to PCIe 3.0 controller Supports eight-lane, full-duplex PCIe 3.0 performance Supports eight external 12Gb/s SATA+SAS ports Supports SATA link rates of 3Gb/s and 6Gb/s Supports SAS link rates of 3Gb/s, 6Gb/s, and 12Gb/s Provides two x4 external mini-sas HD connectors (SFF-8644) Supports passive copper cable, active copper cable, and optical cable Supports up to 1024 SATA or SAS end devices Offered with a full-height bracket and a low-profile vented bracket Provides one heartbeat LED 3 Functional Descriptions 3.1 PCI Express Interface PCIe is a high-speed standard local bus for point-to-point interfacing of I/O components to the processor and the memory subsystems in high-end computers and servers. The LSI SAS 3008 controller chip contains the PCIe functionality for the LSI 12Gb/s SAS HBA. The LSI SAS 3008 controller chip connects to the PCIe bus and generates timing and protocol in compliance with the PCIe specifications. The LSI 12Gb/s SAS HBA supports eight-lane PCIe performance up to 64Gb/s single direction and 128Gb/s dual direction. - 3 -

Operating System Support 3.2 SAS-3 Interface The LSI SAS 3008 controller chip contains the SATA+SAS functionality for the LSI 12Gb/s SAS HBA. The following table shows the LSI SAS 12Gb/s SAS performance. Half Duplex Narrow port (one lane), 1200 MB/s Wide port (four lanes), 4800 MB/s Full Duplex Narrow port (one lane), 2400 MB/s Wide port (four lanes), 9600 MB/s 3.3 Active Cable Management Support The HBA optionally supports active cable management. To enable this feature, download and implement the firmware option labeled SAS93xx_xx_IT_ACM, where xx_xx matches your product. You must enable active cable management for applications with active optical cables. 4 Operating System Support The LSI 12Gb/s SAS HBA supports all major operating systems: Windows, Linux Red Hat, Linux SUSE Enterprise Server (SLES), and VMware. The HBA also supports Solaris 11 Update 2. Refer to http://go.lsi.com/hbas for details on the software versions and device driver support. For Solaris support, contact the Avago Technical Support team. 5 LSI SAS 9300-8e HBA Characteristics 5.1 Memory 5.2 LED The LSI 12Gb/s SAS HBA provides one 4-M 16-bit Flash ROM to store the firmware and the BIOS. The LSI 12Gb/s SAS HBA Heartbeat LED, CR1, blinks green to indicate the HBA is capable of general activity. 5.3 Connectors PCIe Connector (EC1). The LSI 12Gb/s SAS HBA supports a x8 interface. The PCIe host interface connection is through the edge connector, EC1, which provides connections on both the top (EC1 B) and bottom (EC1 A) of the board. The signal definitions and pin numbers conform to the PCIe specification. SATA+SAS Connector (J6). The LSI 12Gb/s SAS HBA supports SATA and SAS connectors through connectors that are SFF-8644 mini-sas HD, external connectors. 5.4 Physical Characteristics The LSI 12Gb/s SAS HBA is a 6.6-in. 2.7-in., low-profile board. The component height on the top and bottom of the LSI 12Gb/s SAS HBA is in accordance with the PCIe specification. The following figure shows the HBA board layout. - 4 -

LSI SAS 9300-8e HBA Characteristics Figure 1 LSI SAS 9300-8e HBA Board Layout LSI SAS 3008 EC1 PCIe x8 board edge connector CR1 Heartbeat LED J6 SFF-8644 mini-sas HD, external, right-angle connectors 5.5 Electrical Characteristics The power requirements for the LSI SAS 9300-8e HBA under normal operation are as follows: PCIe 12.0 V = 1.07 A Power values: Nominal = 14.5 W Worst case = 22.5 W 5.6 Thermal and Atmospheric Limits The atmospheric limits for the LSI 12Gb/s SAS HBA are as follows: Temperature range: 0 C to 55 C (32 F to 131 F) (dry bulb) Relative humidity range: 5% to 90% noncondensing Maximum dew point temperature: 32 C (89.6 F) Minimum airflow: 200 linear feet per minute at 55 C inlet temperature The following limits define the storage and transit environment for the LSI 12Gb/s SAS HBA: Temperature range: 45 C to +105 C ( 49 F to +221 F) (dry bulb) Relative humidity range: 5% to 90% noncondensing - 5 -

LSI 12Gb/s SAS HBA Certifications and Safety Characteristics 6 LSI 12Gb/s SAS HBA Certifications and Safety Characteristics All LSI 12Gb/s SAS HBAs meet or exceed the requirements of UL flammability rating 94V-0. Each bare board is marked with the supplier s name or trademark, type, and UL flammability rating. Because these boards are installed in a PCIe bus slot, all voltages are less than the SELV 42.4-V limit. The design and implementation of the LSI 12Gb/s SAS HBA minimizes electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The LSI 12Gb/s SAS HBA meets the following integrated electromagnetic interference (EMI) compliance labels: CE mark RCM mark Canadian Compliance Statement FCC Class B, marked with the FCC Self-Certification logo UL Listed Mark for Canada/U.S. Japan VCCI Korean KCC Taiwan BSMI The LSI 12Gb/s SAS HBA meets the following environmental directives: RoHS WEEE 7 Hardware Installation Instructions To install the LSI 12Gb/s SAS HBA, follow these steps: 1. Unpack the HBA, and inspect it for damage. Unpack the HBA in a static-free environment. Remove the HBA from the antistatic bag, and carefully inspect the device for damage. If you notice any damage, contact Avago or your reseller support representative. ATTENTION To avoid the risk of data loss, back up your data before changing your system configuration. 2. Prepare the computer. Turn off the computer, and disconnect the power cord from the rear of the power supply. CAUTION Disconnect the computer from the power supply and from any networks to which you will install the HBA, or you risk damaging the system or experiencing electrical shock. 3. Remove the cover from the chassis. 4. Check the mounting bracket on the HBA (system-dependent). If required for your system, replace the full-height mounting bracket that ships on the HBA with the low-profile bracket supplied. 5. Insert the HBA into an available PCIe slot. Locate an empty x8 PCIe slot. Remove the blank bracket panel on the rear of the computer that aligns with the empty PCIe slot. Save this bracket screw, if applicable. Align the HBA to a PCIe slot. Press down gently, but firmly, to seat the HBA correctly in the slot. The following figure shows how to insert the HBA into a PCIe slot. - 6 -

Technical Support Figure 2 Install an LSI 12Gb/s x8 HBA in a PCIe Slot NOTE The shape, size, and locations of the components on your HBA and its bracket might vary from this illustration. The HBA requires a x8 PCIe slot. 6. Secure the HBA bracket to the system s chassis. Install the bracket screw, if applicable, or engage the system retention mechanism to secure the HBA to the system s chassis. 7. Replace the cover of the chassis. 8. Connect SAS cables between the HBA and the SAS enclosure that contains SATA or SAS devices. The LSI 12Gb/s SAS HBA has two SFF-8644, external x4, mini-sas HD connectors. Use a cable with an external mini-sas HD connector (SFF-8644) on one end (to connect to the HBA) and the appropriate connector to attach to the enclosure that contains SAS or SATA devices on the other end. 9. Reconnect any power cords, and power up the system. Reconnect any power cords and reconnect any network cables. Turn on the power. The hardware installation of your LSI 12Gb/s SAS HBA is complete. 8 Technical Support For assistance installing, configuring, or running the LSI 12Gb/s SAS HBA, contact Technical Support: Email: globalsupport.pdl@avagotech.com Website: http://www.lsi.com/support/pages/submit-support-request.aspx - 7 -

Revision History Revision History Version 1.3, The following document change was made: Changed Solaris operating system support. Version 1.2, September 2014 The following document changes were made: Added Active Cable Management Support section. Updated URL references. Template update. Version 1.1, December 2013 The following document change was made: Removed RAID support phrases. Version 1.0, March 2013 Initial document release. - 8 -