Product type designation. General information. Supply voltage. Input current. Power losses

Similar documents
Product type designation. General information. Supply voltage. Input current. Power loss

General information. Supply voltage. Input current

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Product type designation. General information. Supply voltage

General information. Supply voltage

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Product type designation. General information. Supply voltage. Input current

SIPLUS CPU 313C-2DP. Function

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

CPU 412H. Function. Parameterizable properties

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. Supply voltage

CPU 412. Function. Programmable properties

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

Product type designation

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

General information. Supply voltage

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet VIPA CPU 115DP (115-6BL22)

Multi Panel options. SIMATIC WinAC MP 2/169

Data sheet CPU 315SN/PN ECO (315-4PN33)

Data sheet CPU 115 (115-6BL02)

Data sheet CPU 015PN (015-CEFPR01)

Data sheet VIPA CPU M13C (M13-CCF0000)

General information. Display. Supply voltage. Input current

Data sheet CPU 015PN (015-CEFPR00)

Data sheet SLIO CPU 015PN (015-CEFPR01)

SIMATIC PC-based controller

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Supply voltage. Input current. Encoder supply. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Data sheet CPU 013C (013-CCF0R00)

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

PROFINET/Industrial Ethernet Controllers / Modular controllers / SIMATIC S7-400

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

General information. Configuration control. Display. Control elements. Supply voltage

SIMATIC S /4 Central processing units 4/4 Compact CPUs 4/21 Standard CPUs 4/43 Technology CPUs 4/51 Fail-safe CPUs

Main Catalog 2012/2013 for specialists in automation and control technology

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Operating and Monitoring Systems

CPU 1214C. Overview. Design. The compact CPU 1214C has:

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

Distributed I/Os SIMATIC ET 200

System description SLIO

SIMATIC S Central processing units

STEP 7. Function. Page 1791 Mar 2008 Siemens ITS

Transcription:

Data sheet SIMATIC S7-300, CPU317-2 DP, CENTRAL PROCESSING UNIT WITH 1 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, MICRO MEMORY CARD NECESSARY Product type designation General information Hardware product version 01 Firmware version V3.3 Engineering with Programming package STEP7 as of V5.5 + SP1 or STEP 7 V5.2 + SP1 or higher with HSP 202 Supply voltage Rated value (DC) 24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) External protection for supply cables (recommendation) Mains buffering Mains/voltage failure stored energy time Repeat rate, min. Input current Current consumption (rated value) Current consumption (in no-load operation), typ. Inrush current, typ. I²t Power losses Power loss, typ. 19.2 V 28.8 V 2 A min. 5 ms 1 s 870 ma 120 ma 4 A 1 A² s 4.5 W Page 1/11 12.03.2015 Copyright Siemens AG

Memory Work memory Integrated expandable Size of retentive memory for retentive data blocks Load memory pluggable (MMC) pluggable (MMC), max. Data management on MMC (after last programming), min. Backup present without battery 1 024 kbyte 256 kbyte 8 Mbyte 10 y ; Guaranteed by MMC (maintenance-free) ; Program and data CPU processing times for bit operations, typ. 0.025 µs for word operations, typ. 0.03 µs for fixed point arithmetic, typ. 0.04 µs for floating point arithmetic, typ. 0.16 µs CPU-blocks Number of blocks (total) 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. DB Number, max. 2 048; Number range: 1 to 16000 Size, max. 64 kbyte FB Number, max. 2 048; Number range: 0 to 7999 Size, max. 64 kbyte FC Number, max. 2 048; Number range: 0 to 7999 Size, max. 64 kbyte OB Description see instruction list Size, max. 64 kbyte Number of free cycle OBs 1; OB 1 Number of time alarm OBs 1; OB 10 Number of delay alarm OBs 2; OB 20, 21 Number of time interrupt OBs 4; OB 32, 33, 34, 35 Number of process alarm OBs 1; OB 40 Number of DPV1 alarm OBs 3; OB 55, 56, 57 Number isochronous mode OBs 1; OB 61 Page 2/11 12.03.2015 Copyright Siemens AG

Number of startup OBs 1; OB 100 Number of asynchronous error OBs 5; OB 80, 82, 85, 86, 87 Number of synchronous error OBs 2; OB 121, 122 Nesting depth per priority class 16 additional within an error OB 4 Counters, timers and their retentivity S7 counter Number 512 Retentivity can be set lower limit 0 upper limit 511 preset Z 0 to Z 7 Counting range lower limit 0 upper limit 999 IEC counter present Type SFB Number Unlimited (limited only by RAM capacity) S7 times Number 512 Retentivity can be set lower limit 0 upper limit 511 preset retentivity Time range lower limit 10 ms upper limit 9 990 s IEC timer present Type SFB Number Unlimited (limited only by RAM capacity) Data areas and their retentivity Total retentive data area All, max. 256 KB Flag Number, max. 4 096 byte Retentivity available ; From MB 0 to MB 4095 Retentivity preset MB 0 to MB 15 Page 3/11 12.03.2015 Copyright Siemens AG

Number of clock memories 8; 1 memory byte Data blocks Number, max. 2 048; Number range: 1 to 16000 Size, max. 64 kbyte Retentivity adjustable ; via non-retain property on DB Retentivity preset Local data per priority class, max. 32 768 byte; Max. 2048 bytes per block Address area I/O address area Inputs Outputs of which, distributed Inputs Outputs Process image Inputs Outputs Inputs, adjustable Outputs, adjustable Inputs, default 256 byte Outputs, default 256 byte Subprocess images Number of subprocess images, max. 1 Digital channels Inputs 65 536 Inputs, of which central 1 024 Outputs 65 536 Outputs, of which central 1 024 Analog channels Inputs 4 096 Inputs, of which central 256 Outputs 4 096 Outputs, of which central 256 Hardware configuration Expansion devices, max. 3 Number of DP masters Integrated 2 Via CP 4 Number of operable FMs and CPs (recommended) FM 8 Page 4/11 12.03.2015 Copyright Siemens AG

CP, point-to-point 8 CP, LAN 10 Rack Racks, max. 4 Modules per rack, max. 8 Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Deviation per day, max. 10 s; Typ.: 2 s Backup time 6 wk; At 40 C ambient temperature Behavior of the clock following POWER-ON Clock continues running after POWER OFF Behavior of the clock following expiry of backup Clock continues to run with the time at which the power failure period occurred Operating hours counter Number 4 Number/Number range 0 to 3 Range of values 0 to 2^31 hours (when using SFC 101) Granularity 1 hour retentive ; Must be restarted at each restart Clock synchronization supported to MPI, master to MPI, slave to DP, master ; With DP slave only slave clock to DP, slave in AS, master in AS, slave on Ethernet via NTP Digital inputs Number of digital inputs 0 Digital outputs Number of digital outputs 0 Analog inputs Number of analog inputs 0 Analog outputs Number of analog outputs 0 Interfaces Number of USB interfaces 0 Number of 20 ma interfaces (TTY) 0 Page 5/11 12.03.2015 Copyright Siemens AG

Number of RS 232 interfaces 0 Number of RS 422 interfaces 0 Number of parallel interfaces 0 Number of other interfaces 0 1st interface Interface type Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. 200 ma Functionality MPI DP master DP slave ; A DP slave at both interfaces simultaneously is not possible Point-to-point connection MPI Transmission rate, max. 12 Mbit/s Services PG/OP communication Routing Global data communication S7 basic communication S7 communication ; Only server, configured on one side S7 communication, as client ; but via CP and loadable FB S7 communication, as server DP master Transmission rate, max. 12 Mbit/s Number of DP slaves, max. 124 Services PG/OP communication Routing Global data communication S7 basic communication ; I blocks only S7 communication ; Only server, configured on one side S7 communication, as client S7 communication, as server Equidistance mode support Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves Number of DP slaves that can be 8 simultaneously activated/deactivated, max. Page 6/11 12.03.2015 Copyright Siemens AG

Direct data exchange (slave-to-slave ; As subscriber communication) DPV1 Address area Inputs, max. 8 kbyte Outputs, max. 8 kbyte User data per DP slave Inputs, max. 244 byte Outputs, max. 244 byte DP slave Transmission rate, max. 12 Mbit/s Automatic baud rate search ; only with passive interface Address area, max. 32 User data per address area, max. 32 byte Services PG/OP communication Routing ; Only with active interface Global data communication S7 basic communication S7 communication ; Only server, configured on one side S7 communication, as client S7 communication, as server ; Connection configured on one side only Direct data exchange (slave-to-slave communication) DPV1 Transfer memory Inputs 244 byte Outputs 244 byte 2nd interface Interface type Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V DC), max. 200 ma Functionality MPI DP master DP slave ; A DP slave at both interfaces simultaneously is not possible Point-to-point connection DP master Transmission rate, max. 12 Mbit/s Number of DP slaves, max. 124 Page 7/11 12.03.2015 Copyright Siemens AG

Services PG/OP communication Routing Global data communication S7 basic communication ; I blocks only S7 communication ; Only server, configured on one side S7 communication, as client ; but via CP and loadable FB S7 communication, as server Equidistance mode support Isochronous mode ; OB 61 SYNC/FREEZE Activation/deactivation of DP slaves Number of DP slaves that can be 8 simultaneously activated/deactivated, max. Direct data exchange (slave-to-slave ; As subscriber communication) DPV1 Address area Inputs, max. Outputs, max. User data per DP slave Inputs, max. 244 byte Outputs, max. 244 byte DP slave GSD file The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd) Transmission rate, max. 12 Mbit/s Automatic baud rate search ; only with passive interface Address area, max. 32 User data per address area, max. 32 byte Services PG/OP communication Routing ; Only with active interface Global data communication S7 basic communication S7 communication ; Only server, configured on one side S7 communication, as client ; but via CP and loadable FB S7 communication, as server Direct data exchange (slave-to-slave communication) DPV1 Transfer memory Page 8/11 12.03.2015 Copyright Siemens AG

Inputs 244 byte Outputs 244 byte Communication functions PG/OP communication Data record routing Global data communication supported Number of GD loops, max. 8 Number of GD packets, max. 8 Number of GD packets, transmitter, max. 8 Number of GD packets, receiver, max. 8 Size of GD packets, max. 22 byte Size of GD packet (of which consistent), max. 22 byte S7 basic communication supported User data per job, max. 76 byte User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) S7 communication supported as server As client ; Via CP and loadable FB User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) S5-compatible communication supported ; via CP and loadable FC Number of connections overall 32 usable for PG communication 31 reserved for PG communication 1 Adjustable for PG communication, min. 1 Adjustable for PG communication, max. 31 usable for OP communication 31 reserved for OP communication 1 adjustable for OP communication, min. 1 adjustable for OP communication, max. 31 usable for S7 basic communication 30 Reserved for S7 basic communication 0 adjustable for S7 basic communication, 0 min. adjustable for S7 basic communication, 30 max. Page 9/11 12.03.2015 Copyright Siemens AG

usable for routing X1 as a MPI, max. 10; X1 as DP Master max. 24; X1 as DP Slave (active) max. 14; X2 as DP Master max. 24; X2 as DP Slave (active) max. 14 S7 message functions Number of login stations for message functions, max. 32; Depending on the configured connections for PG/OP and S7 basic communication Process diagnostic messages simultaneously active Alarm-S blocks, max. 300 Test commissioning functions Status block ; Up to 2 simultaneously Single step Number of breakpoints 4 Status/control Status/control variable Variables Inputs, outputs, memory bits, DB, times, counters Number of variables, max. 30 of which status variables, max. 30 of which control variables, max. 14 Forcing Forcing Force, variables Inputs, outputs Number of variables, max. 10 Diagnostic buffer present Number of entries, max. 500 can be set Of which powerfail-proof 100; Only the last 100 entries are retained Number of entries readable in RUN, max. 499 can be set ; From 10 to 499 preset 10 Service data Can be read out Ambient conditions Ambient temperature in operation Min. 0 C max. 60 C Configuration Configuration software STEP 7 STEP 7 Lite ; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 Page 10/11 12.03.2015 Copyright Siemens AG

programming Command set see instruction list Nesting levels 8 System functions (SFC) see instruction list System function blocks (SFB) see instruction list Programming language LAD FBD STL SCL CFC GRAPH HiGraph Know-how protection User program protection/password protection Block encryption ; With S7 block Privacy Dimensions Width Height Depth Weights Weight, approx. 40 mm 125 mm 130 mm 360 g last modified: 12.03.2015 Page 11/11 12.03.2015 Copyright Siemens AG