INSTALLATION & OPERATING INSTRUCTIONS

Similar documents
RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Weathersafe Vision. Installation & Operating Instructions

Slimline LED Floodlight

BOOSTMASTER ELECTRONIC BOOST TIMER

7 Day Programmable Room Thermostat

Wireless 7 Day Programmable Room Thermostat

2400W PIR Light Controller

DOOR INTERCOM SYSTEM WITH 2.4 COLOUR LCD

18W Round LED Bulkhead Light with Microwave Sensor

7 Day Digital Programmer 1 Channel Surface Mount

7 Day Digital Programmer 2 Channel Surface Mount

2x 10W LED Slimline PIR Floodlight Twin Flood

BT Duet 210. User Guide

UK s best selling phone brand. User Guide. BT Duet 210. Corded Phone

smartentry Wireless Video Doorphone User Manual

Important micro SIM card information Kit contents / parts diagrams Pre-install checks / Smartbel assembly

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

CONTENTS. INTRODUCTION 3 Unpacking the Telephone 4. DESCRIPTION 5 General Description 5. INSTALLATION 10 Setting Up 10 Wall Mounting 11

Wireless door phone INSTALLATION AND USER S GUIDE. Ed V11 AG 651 AG 652

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

DP-222Q Color Video Door Phone Manual

Typ: CAS # GEV_1_fam_RZ_luensee_print.indd :53

CIB 3047 (14B) 10-Button Voice Terminal Fixed Desk Stand and Wall Mount (32007)

Cordless Additional Handset & Charger. User Guide

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Corded Big Button Telephone with Speakerphone

Alphacom a200 USER GUIDE. Versatility 1 & Value

CL210A TELEPHONE & ANSWERING MACHINE

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

Luna. Instruction Manual

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

BT Decor User Guide

DP-222Q Color Video Door Phone Manual

User Guide. Telstra M450. Digital Answering Machine

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

agent 1000 Instruction Manual

BT Duet 20 Issue 2 Edition User Guide BT DUET 20

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

BTS300S-BLK. DuraVibePro. Bluetooth Speaker USER MANUAL

Response 5 answering machine

Service & Maintenance

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

Converse 2-line Telephone. User Guide

BT Big Button 100 Edition User Guide BT Big Button 100

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

BT CONVERSE 2200 User Guide

WIRED REMOTE INSTALLATION GUIDE

605 D E C T G I n t e r c o m

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

User Guide. Monitor 420. Digital Answering Machine

DS1 USER GUIDE. For Technical Assistance call the Manufacturers direct Ph AM - 5PM West Coast Pacific Time

LAZER Model 905K USER GUIDE

TEL35. User guide. Hands-free Speakerphone with LCD Display. Computer & Telephone Services Ltd NZ

Now available to purchase from

USER MANUAL MODEL: TDPB-2V1AD Dual square table box with HDMI, VGA, 3.5mm audio, and RJ45 inputs

Main menu. Camera/Door. Intercom. Playback. Do not disturb USER MANUAL VESTA2 GB2 MONITOR

Telstra T210 Telephone User Guide

Do not attempt to service the unit yourself. Seek assistance from a qualified professional.

DECT CLIP UC-01 USER GUIDE

User Guide Bluetooth Indoor/Outdoor Speaker

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

Stereo Turntable System

603 D E C T I n t e r c o m

Headset Intercom System. Model C1060. Operating Instructions

INSTALLATION INSTRUCTIONS

INTRODUCTION TO YOUR NEW PHONE WELCOME FEATURES INTRODUCTION

LAZER Model 906K USER GUIDE

Model No. Manuals and supporting information are provided on the Panasonic Web site at:

Always there to help you. Register your product and get support at AEA2000. Question? Contact Philips.

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

To connect the AC adapter:

B&W RearView Camera Installation & Operation

Installation Manual BAK02


Intelligent Security & Fire Ltd

UK s best selling phone brand. User Guide. BT Converse 2100 Corded Phone

K Service Source. StyleWriter

PHONE EASY. User guide. Big Button Telephone. Computer & Telephone Services Ltd NZ

User Guide BT RESPONSE 123e

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Response Edition 5 26th October 00. User Guide

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

OPTRON mobile. User Guide. magnified vision. Vers. 2.1AL Magnified Vision, Inc. 2013

User guide. 2, PlayStation, Ø, Ã and KHJL are registered trademarks of Sony Interactive Entertainment Inc. All rights reserved.

JanusRAID SA-6692J Hardware User Manual

Wireless Amp Speaker With AUX Port

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

Operators Guide. Vision 8 Pan & Tilt Head. Vinten Camera Control Solutions

RZ5/RZ5D/RZ6 Processor. Operator s Manual

MacBook Core 2 Duo Display Replacement

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

Decor 100. Userfriendly Guide

ADSL Central Splitter Quick Setup Guide

Mounting on the Ceiling Using Flush Mount (Face Down)

User Guide. Slimline 25. Telephone

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Yale School Street, Willenhall, West Midlands WV13 3PW Tel: Fax: +44 (0)

Transcription:

AUDIO DOOR ENTRY SYSTEM DCA2 Model: DCA1 Single Channel DCA2 Twin Channel DCA1/2 DCA1 INSTALLATION & OPERATING INSTRUCTIONS

1. Introduction The DCA1/DCA2 Door Entry System enhances entry security by enabling the user to recognise the potential entrant by audible means before opening the door. An electric door catch (not supplied) is available as an optional extra for the DCA1/DCA2 to make the door opening automatic. The DCA2 external intercom has the ability to call separately located internal intercoms for two individual dwellings with a common entrance. The DCA1 calls one. Connecting cables between component parts are all 2 core, so existing bell flex can be used to connect the internal and external units if desired. 2. Overview If operation with an electric door catch is required then part DCLR is a fail (power off) secure catch available from Timeguard. 1 3 1 7 5 Fig 1 Component parts of Single Channel system. 10 1. External intercom (1 channel shown) 2 4 2. Internal intercom 8 9 3. Mains adaptor 4. 15m of 2 core connecting cable 5. Cable terminals 7. Ring button 8. Ringtone volume adjust (2 position switch) 9. Door open button 10. Mains adaptor low voltage plug

External intercom (DCA2 shown) Internal intercom (first channel) Internal intercom (second channel) Handset cable Electric door catch (not supplied) 2 Handset cable Fig 2 Wiring diagram for Two Channel system. 6. Terminal strip 11. Mains adaptor socket 12. Internal intercom mounting hole 13. Cable channel Note: For single channel operation ignore second channel internal intercom and its 2 core connecting cable to terminals 3 and 4 on the external intercom.

3. Selecting intercom sites and cabling 3.1 Intercom sites The internal intercom should be located at a convenient position for all potential users at the height indicated in fig 3a and at a maximum distance of 70m from the external intercom. If all the users are significantly above or below average height then a different mounting height may be considered appropriate. The external intercom should be sited in an area away from driving rain and surface water, out of direct sunlight as far as possible and protected by the minimum of an open porch in a position readily accessible to potential entrants. It should be mounted at the height indicated in fig 3b. 50cm 75º 3 165 cm 165 cm Fig 3a Internal intercom mounting height Fig 3b External intercom mounting height and coverage

3.2 Cabling Connection between the internal and external intercoms is by 2 core cable and must be no more than 70 m long. Two core (13 x 0.2) bell flex is suitable. A 15m length (2 lengths for DCA2) of 2 core cable is supplied with the kit and existing bell cable runs can be made use of. The cable run should be kept at least 100mm away from mains cables to avoid interference. A second relatively short 2 core cable (13/0.2 bell flex) will be required between the external intercom and the door catch (if used). A further 2 core cable (13/0.2 bell flex) will be required (if extension beyond 15m is necessary) between the external intercom and the second internal intercom for the DCA2. 4. Fixing Intercoms 4.1 External intercom Important: To give the best possible waterproofing and appearance we recommend taking the wiring through the exterior wall directly behind the external intercom so that the cabling will feed directly through the back box wiring slot. If the surface to be fixed to is not even (e.g. pebbledash or brickwork with raised pointing) we recommend the use of at least 10mm (3/8") thick marine ply as a mounting plate between the wall and the back box to prevent its distortion and loss of waterproofing. 4

5 i Remove the back box from the external intercom in the following way. Insert a small screwdriver blade in the end cap screwdriver notch (fig 4, i) and lever end cap so that it slides outwards from the main case (in opposite directions to those shown in fig 4, iv). Remove the two fixing screws (as shown in fig 4, iii) and remove the back box from the rear of the external intercom. ii This is a convenient time to mark the nameplate(s). Referring to figs 5i and 5iii push catches at each end of the transparent housing inwards as shown in fig 5iii and remove ring burtton and nameplate assembly followed by the nameplate transparent cover, finally levering out the nameplate as required. Mark the nameplate as required with a permanent fibre-tipped pen. When dry insert the name plate in its transparent cover, ensuring it is the right way up. Snap the transparent cover into the housing bearing in mind it is not symmetrical and the end with the thicker lip goes at the end closest to the ring button switch. Offer the transparent housing to the external intercom casing ensuring wiring is not trapped and snap the catches into place. Check the ring button and the nameplate are correctly located. Repeat for second ring button and nameplate assembly if necessary. Fig 4 i ii iii iv x Y End plate Screwdriver notch Wiring slot End cover End cover X = wire to the inside intercom (2 for DCA2) Y = wire to door catch (if required)

Fig 5i Rear access to nameplates (DCA2 shown) 1 2 3 4 5 6 7 8 Catch Catch Ring button switch Transparent housing Fig 5ii Side view of length of nameplate This (thicker) end goes closest to ring button switch 6 Fig 5iii Transparent housing PCB Push catch inwards Ring button switch Transparent housing Catch

iii Offer the back box up to the required position on the wall (refer to section 3.1). Feed the cables through the wiring slot in the back box (see fig 4, ii). Mark the positions of the two fixing screws (No. 8 roundhead) using the back box as a template (see fig 4, ii). Remove the back box, drill and, if necessary plug holes. Feed the cables through the wiring slot. Fix the back box to the wall. iv Make the necessary wire terminations (see fig 2) and offer the external intercom up to the back box. Tighten the fixing screws as indicated (fig 4, iii). v Slide the two end covers inwards as shown until fully home (see fig 4, iv). 7 4.2 Internal intercom Choose a position which can be reached easily by all potential users. If one person usually in one location will be the main user it may be considered appropriate to locate the internal intercom within reach of that person. Mark out two holes suitable for No. 8 roundhead screws 164mm vertically apart at the required location on the wall (refer to section 3.1 and fig 2). Drill and plug the holes if necessary then screw the screws home leaving 5mm of the shank exposed (see fig 6) to enable keyhole fixing points to slide behind the screws. Connect the two core lead from the external intercom according to fig 2. Plug the mains adaptor low voltage plug (see fig 1) into the mains adaptor socket (see fig 2). Arrange the two cables in the cable channel on the back of the internal intercom. Finally locate the internal intercom mounting holes on the two fixing screws, and slide the intercom downwards. Fig 6 5mm Wall surface

5. Commissioning/Use Press the ring button (fig 1, 7) at the external intercom a buzz will be heard locally and a ring tone will be heard at the internal intercom unit for 2 to 3 rings. Once handset is lifted, two way communication is possible via the microphone and speaker at the external intercom. Finally, if a door catch is fitted, the door open button (fig 1, 9) should be pressed and the door can be opened. It is not necessary for the handset to be lifted to use the door open facility. It is possible to adjust the ringtone volume with the slide switch (fig 1, 8) on the side of the internal intercom. 6. Do s and Dont s 1. Never use the product if it shows any signs of damage. 2. In case of damage to the product unplug the mains adaptor from the mains supply to avoid any possibility of electric shock and have the damage examined by a competent person. 3. When laying cabling ensure that no cables (particularly mains cables) are damaged. 4. Never try to operate the mains adaptor at a voltage other than 230V 50Hz. 5. The installation should only be carried out by a competent person. 6. The internal intercom should be kept out of reach of children and unauthorised persons. 7. Keep low voltage cabling at least 100mm away from any mains cabling. 8. Ensure that all electrical connections are made and wires are arranged according to the instructions. 9. Do not cover the louvres on the internal intercom. 8

9 7. Troubleshooting No Audio Check cable between internal and external intercoms is connected correctly. Check that there are no breaks or damage to the interconnecting two core cable. Check that the mains adaptor is plugged in and switched on. Door catch not working Check cable between external intercom and door (if fitted) catch for breaks or damage. Check that terminations are correctly made at each end of the above cable. Check that the mains adaptor is plugged in and switched on. 8. Cleaning Unplug mains adaptor before cleaning product. Clean internal and external intercoms with a damp cloth only no cleaning agents. Remove dust deposits from the louvres on the internal intercom with a soft brush or vacuum cleaner.

9. Specifications Mains adaptor: 230V 50Hz/15V, 1A Maximum interconnect length between internal and external intercoms: 70m (13/0.2 bell flex) Power consuption Standby: 3W In operation: 10W Operating temperature: -10 C to +50 C Ringtone volume: 80dBA at 0.3m maximum (adjustable by 2 position slide switch) Door catch: Max 12V DC 1A 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. 10 Recycling When service life is over please consult your local authority regarding method of disposal.

HELPLINE 020-8450-0515 11 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com 67-058-232