T9 EPP KEYPAD FIELD UPGRADE

Similar documents
EMV 330 CARD READER UPGRADE

SECURITY MODULE UPGRADE

TDM To MiniMech conversion ProceDure

TDM-100/150 TO NMD-50 CONVERSION PROCEDURES RL5000

Controller PC Hard Drive

9600 PCI EPP Keypad and

Serial Printer Controller

X-SCALE TO X2 CONVERSION

Peel/Rewind Upgrade Kit

SPEECH UPGRADE INSTALLATION GUIDE (MODEL 9100)

Serial Printer Controller. 91xx / Mako / 97xx. TDN Oct 09, 2012

How To Install: C4000 EMV Upgrade Kit

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

USB MODEM UPGRADE INSTALLATION/SETUP PROCEDURES (MODELS RL/FT5000/RT2000)

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Upgrading LVDS Cables Instruction Sheet

Replacement Instructions

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

CARD PRINTER PRINTHEAD REPLACEMENT INSTRUCTIONS

Adding or Replacing a PCI Card

Installation Guide. Copyright 2005 MSI Computer Corp.

INSTRUCTION BULLETIN

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Print Mechanism Maintenance Kit

To connect the AC adapter:

System Storage EXP3000 Rack Installation Instructions

Megatouch FORCE Monitor Chassis Board Replacement

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

Dell Inspiron N5110 Service Manual

Encore XT Manual Gun Upgrade Kit

Z Series and S4M Ribbon Take-Up Spindle Maintenance Kit

Installation Instructions

Gateway Profile 4 service guide

E2460GS Oscilloscope Upgrade Kit

Installing a Power over Ethernet injector

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

PC9/P9 CPU Card Replacement

Replacement Keyswitch Assembly

Vertiv Local Rack Access 18.5" LED LCD Console

C764i Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Cycles Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Codonics Virtua Virtua-2 Optical Drive Replacement

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

INSTALLATION MANUAL DATAVAULT DATAVAULT - BARE JOBSITE STORAGE SOLUTIONS

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

G12/G12x USER S MANUAL

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Biesemeyer Fence Kit Installation Instructions:

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

Replacement Instructions

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

INSTALLATION MANUAL DATAVAULT DATAVAULT - BARE JOBSITE STORAGE SOLUTIONS

INSTALLATION INSTRUCTIONS

Replacing the Billboard Diagnostic Camera

IBM. Rack Installation Instructions

Rack Installation Instructions

Dell Inspiron XPS and Inspiron 9100 Service Manual

Installation Note. 8719D, 8720D, and 8722D Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit

Removal and Installation8

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

120Ra-1 Pentium III Processor Installation Insert

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Installing the Server into a Rack

Epson SureColor F6070 Setup Guide

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Shop Fox Fence Kit Installation Instructions:

Royal RVV-500 (B) Retrofit Kit

Dell XPS 14z Owner s Manual

Removing and Replacing Parts

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Wiwynn SV320 Maintenance User Manual

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Upgrade Instructions Printer Terminal Holder

Upgrading and Servicing Guide

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Replacing/Upgrading Mac Pro Processors (Early 2008)

Upgrading and Servicing Guide

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

Oracle <Insert Picture Here>

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Replacing the Power Supply

EMC 10T "CE" Mechanical Upgrade Procedure

Upgrading and Servicing Guide

Flat Panel Static Wall Mount MSP-SS (GSM-210)

How To Install: G2500 EMV Upgrade Kit

Installing and Removing SDRAM and DRAM

CAMERA ASSEMBLY. Removal/Replacement of the Camera Box Assembly APR-CA. Install Camera Assembly. Remove Camera Assembly

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Replacement Instructions. Backplane PCA for the HP Router 650

LED Lighting Kit For Elara NanoEdge Fixed Frame. Installation Guide. Attention: Read this guide before assembling your screen.

HP Pavilion dv7-6c90us Cooling fan Replacement

Dell Latitude V710/V740 Service Manual

Sonnet AV/HPV Card Video Adapter Kit

XTM 1050 Replacement Parts Installation

Transcription:

T9 EPP KEYPAD FIELD UPGRADE TDN 07103-00237 July 1, 2014 Corporate Headquarters 21405 B Street Long Beach, MS 39560 Phone: (800) 259-6672 Fax: (228) 868-9445 COPYRIGHT NOTICE 2014 Triton. All Rights Reserved. TRITON logo is a registered trademark of Triton Systems of Delaware, LLC

T9 EPP KEYPAD INSTALLATION Document Updates July 1, 2014 Original *ATTENTION* All left and right orientation is determined by facing the front of the control panel on the ATM. 2

INTRODUCTION * Warning * ONCE THE T9 EPP KEYPAD IS INSTALLED AND ACTIVATED IN THE UNIT, IT CANNOT BE REMOVED. IF THE KEYPAD IS REMOVED FROM THE UNIT AFTER ACTIVATION, REACTIVATION IS REQUIRED AND CAN ONLY BE PERFORMED BY TRITON TECHNICAL SUPPORT. Contents RT2000 Kit Contents & Tools Required...4 Preparing the T9 for Installation...5 T9 Keypad Installation...6 RL5000, RL2000 & FT5000 Kit Contents & Tools Required...10 RL5000 T9 Keypad Installation...11 RL2000 T9 Keypad Installation...16 FT5000 T9 Keypad Installation...24 3

T9 EPP KEYPAD INSTALLATION RT2000 Installation REQUIRED PARTS AND TOOLS TOOLS REQUIRED KIT 06200-00257 06200-00259 #2 Phillips screwdriver 11/32 open end nut wrench Side cut pliers ESD wrist strap with grounding cord T9 Upgrade Kit, RT2 US T9 Upgrade Kit, RT2 Canada Description Qty T9 PCI 3 EPP Keypad (English or English/French) 1 Dewhurst SPED Cable 1 SPED Mounting Bracket 1 #8-32 3/8 inch Pan Phillips Head Screw 6 #8-32 Star Washer Hex Nut 6 6 inch TY Wrap 10 4

FIELD UPGRADE INSTRUCTIONS Preparing the T9 EPP Keypad for Installation 1. Obtain the keypad and the mounting bracket. 2. Set the keypad face down. Place the mounting bracket on the keypad with the rounded tabs at the top of the keypad as shown below. Ensure the bracket sits flush on the keypad. Front view of rounded tabs at the top of the keypad. 3. Secure the bracket to the keypad as shown with the screws and nuts supplied in the Kit. 5

T9 EPP KEYPAD INSTALLATION T9 EPP Keypad Installation 1. Put the ESD wrist strap on and ground the cord. 2. Perform a proper shutdown of the unit. Open the control panel and flip the power switch on the power supply to the OFF (O) position. 3. Unlock and open the lower cabinet. Unlock the slides and pull the dispenser out to provide more working room in the control panel. 3. Locate the green Keypad Locking Handle to the lower right of the display assembly. Pull the handle down to release the keypad from the control panel. 4. Pull the keypad out of the opening. Disconnect all the cables from the back of the keypad. Set the keypad and bracket aside. 6

FIELD UPGRADE INSTRUCTIONS 6. Unplug the 1x4 function key cables from the left and right side of the display assembly. 7. Remove the cable tubing from the cable clip on the left side of the display assembly. Cut off the TY Wraps to open the cable tubing to expose the 1x4 function key cables. 8. Cut off the TY Wraps securing the 1x4 function cable. Remove the left and right 1x4 function cables. Discard them. 7

T9 EPP KEYPAD INSTALLATION 9. Plug the communication cable and the new 1x4 function cable into the back of the T9 EPP Keypad. 10. Place the T9 EPP into the SPED opening. While holding the T9 EPP in place, push the Keypad Locking Handle up to secure the keypad in place. 11. TY Wrap all the cables together as shown with the green arrow. Route the LEFT 1x4 function cable (indicated left with a label on the cable end) along the bottom of the display assembly. TY Wrap the cables again as shown with the red arrow. 8

FIELD UPGRADE INSTRUCTIONS 12. Plug the LEFT 1x4 function cable (indicated left with a label on the cable end) into the port on the left side (from the front of the unit) of the display assembly. Reinstall the cable tubing onto the cables. TY Wrap the tubing closed to secure and protect the cables. Cut off excess TY Wraps. 13. Route the RIGHT 1x4 function cable (indicated right with a label on the cable end) up the right side (from the front of the unit) of the display assembly and plug it into the port on the side as shown. 14. Reinstall the cable tubing onto the cables. TY Wrap the tubing together to secure and protect the cables. Cut off excess TY Wraps. Secure the cable tubing in the cable clip as shown. 9

T9 EPP KEYPAD INSTALLATION RL5000, RL2000 & FT5000 Installation REQUIRED PARTS AND TOOLS TOOLS REQUIRED KIT 06200-00258 06200-00260 #2 Phillips screwdriver Side cut pliers ESD wrist strap with grounding cord T9 Upgrade Kit, RL2/RL5/FT5 US T9 Upgrade Kit, RL2/RL5/FT5 Canada Description Qty T9 PCI 3 EPP Keypad (English or English/French) 1 Dewhurst SPED Cable 1 K40 x 20 PT Fastener Screw 6 6 inch TY Wraps 3 10

FIELD UPGRADE INSTRUCTIONS RL5000 T9 EPP Keypad Installation 1. Put the ESD wrist strap on and ground the cord. 2. Perform a proper shutdown of the unit. Open the control panel and flip the power switch on the power supply to the OFF (O) position. 3. Unplug the three cables from the back of the keypad (two 1x4 function key cable, SPED data cable). 4. Unplug the SPED 1x4 function key cables from the right and left side of the display assembly. 11

T9 EPP KEYPAD INSTALLATION 5. Loosen, do not remove, the three cable clips indicated in the image below. Remove the SPED 1x4 function key cables. Discard. 6. Remove the 6 screws securing the SPED in place. Discard the screws. 12

FIELD UPGRADE INSTRUCTIONS 7. Set the T9 EPP Keypad into place. Secure the keypad with the 6 screws supplied. 8. Plug the 1x4 function key and data cables into the T9 keypad. 13

T9 EPP KEYPAD INSTALLATION 9. Route the 1x4 function key cable up over the top of the keypad and under the printer power cable as shown. Tighten the cable clip over the printer power cable (green arrow). 10. Continue to route the 1x4 function key cables in the groove up to the display assembly. Route the 1x4 cables under the printer data cable as shown. Route the LEFT side cable (indicated left with a label on the cable end) towards the left side (from the front of the unit) of the display assembly. (red arrow) Route the RIGHT side cable (indicated right with a label on the cable end) towards the right side (from the front of the unit) of the display assembly (green arrow). Tighten the two cable clips to secure the cables in place. 14

FIELD UPGRADE INSTRUCTIONS 11. Plug the 1x4 function key cables into the left and right side of the display assembly using the printed left and right labels on the cables to ensure they are plugged in correctly. 15

T9 EPP KEYPAD INSTALLATION RL2000 T9 EPP Keypad Installation 1. Put the ESD wrist strap on and ground the cord. 2. Perform a proper shutdown of the unit. Open the control panel and flip the power switch on the power supply to the OFF (O) position. 3. Unplug the three cables from the back of the keypad (two 1x4 function key cable, SPED data cable). 4. Remove the 6 screws securing the keypad in the control panel. Discard the screws. Remove the keypad and set aside. 16

FIELD UPGRADE INSTRUCTIONS 5. Remove the thumbscrew securing the main board to the display assembly. Set aside for reinstallation. 6. While lifting up on the green arm (red arrow), slide the main board away from the docking board (yellow arrow). Remove the mainboard and set aside for reinstallation. 17

T9 EPP KEYPAD INSTALLATION 7. Remove the three screws securing the main board bracket. Set the screws aside for reinstallation. 8. Carefully tilt the bracket up and set it out of the way to access the 1x4 function key cable. Unplug the 1x4 function cable from the display assembly. 18

FIELD UPGRADE INSTRUCTIONS 9. Unplug the 1x4 function cable from the left side (from the front of the unit) of the display assembly under the printer assembly. 10. Unroute the two 1x4 function key cables, removing them from the two cable clips (and cutting any TY Wraps). Discard the cables. 19

T9 EPP KEYPAD INSTALLATION 11. Set the T9 EPP Keypad in place in the control panel. Secure it with the 6 screws supplied. Be sure to attach the ground cable to the top left screw as shown. 12. Plug the SPED Data Cable and the supplied 1x4 function cable into the back of the T9 keypad. Route the 1x4 function cable through the two cable clips as shown. 20

FIELD UPGRADE INSTRUCTIONS 13. Route the 1x4 cables around the right side (from the front of the unit) of the card reader. Continue routing the right 1x4 cable (indicated right with a label on the cable end) along the right side of the display assembly. 14. Plug the right 1x4 function cable (indicated right with a label on the cable end) into the 1x4 assembly on the side of the display assembly. 21

T9 EPP KEYPAD INSTALLATION 15. Route the left 1x4 function cable (indicated left with a label on the cable end) underneath the printer chute as shown. 16. Plug the left 1x4 function cable into the 1x4 assembly on the left side of the display assembly as shown. 22

FIELD UPGRADE INSTRUCTIONS 17. Reinstall the main board bracket with the three screws previously removed. 18. Set the main board on the bracket and slide it towards the docking board until the green arm (green arrow) locks in place. Reinstall the green thumbscrew. 23

T9 EPP KEYPAD INSTALLATION FT5000 T9 EPP Keypad Installation 1. Put the ESD wrist strap on and ground the cord. 2. Perform a proper shutdown of the unit. Open the control panel and flip the power switch on the power supply to the OFF (O) position. 3. Unlock and open the lower cabinet. Unlock the slides and pull the dispenser half out to provide more working room in the control panel area. 4. Unplug the three cables from the back of the keypad (two 1x4 function key cable, SPED data cable). 24

FIELD UPGRADE INSTRUCTIONS 5. Remove the 6 screws securing the keypad in place. Keep the cables routed through the cable clip nut remove the screw. Discard the screws. Remove the keypad and set it aside. 6. Unplug the 1x4 function cables from the left and right side of the display assembly. 25

T9 EPP KEYPAD INSTALLATION 7. Cut the TY Wraps the secure the 1x4 function cables. Remove the 1x4 function cables and discard. 8. Place the T9 EPP Keypad in place and secure it with the 6 screws supplied. Be sure to secure the cable clip to the top right screw as shown. 26

FIELD UPGRADE INSTRUCTIONS 9. Plug the SPED data cable and 1x4 keypad cable into the back of the T9 keypad. 10. Plug the Right 1x4 function cable into the port on the right side (from the front of the unit) into the docking board. Plug the Left 1x4 function cable into the port on the left side (from the front of the unit) into the main board as shown. Right 1x4 cable port Left 1x4 cable port 27

T9 EPP KEYPAD INSTALLATION 11. Route and secure the 1x4 cables with the 3 TY Wraps supplied. If present, TY Wrap the cables to the TY Wrap clips secured under the main board as shown. Cut off the excess TY Wrap. 12. Unlock the slides and push the dispenser back into the cabinet. Ensure it locks into place. Close up and lock the unit cabinet. 28

APPENDIX G T9 KEYPAD COPYRIGHT NOTICE 2014 Triton. All Rights Reserved. TRITON logo is a registered trademark of Triton Systems of Delaware, LLC

APPENDIX G Document Updates May 14, 2014 Original ** WARNING ** Once the T9 EPP Keypad is installed and activated in the unit, it CANNOT be removed. If the keypad is removed from the unit after activation, reactivation is required and can only be performed by Triton Technical Support. The T9 EPP Keypad is mostly identical to the T5 EPP Keypad except for: The T9 EPP contains a removal detection switch that deactivates / TAMPERS the EPP if the EPP is ever removed from the ATM. Left and right halves of 3DES keys must be different. No two 3DES keys may have the same value. When replacing current keypad with a T9 EPP, activation is required upon installation. Contents NEW ERROR CODES...3 TO INSTALL THE T9 KEYPAD...4 PRIOR TO T9 KEYPAD ACTIVATION...5 TO ACTIVATE THE T9 KEYPAD...6 TO RECTIVATE THE T9 KEYPAD...7 REPLACING THE BATTERY IN THE T9 KEYPAD...8 G-2

T9 KEYPAD New Error Codes to Support the T9 EPP Error Code 625: SPED - Not Activated Cause: The EPP has not yet been activated for use. Recommended Action: Activate the EPP. Error Code 626: SPED - Not Authorized Cause: The EPP has been removed from the ATM. Recommended Action: Call Triton Technical Support for activation code. G-3

APPENDIX G To Install the T9 Keypad The T9 EPP Keypad is a drop in replacement for RL1613, RL23XX, RL53XX, RT23XX, FT53XX and ARGO built with a T5 or T7 EPP keypad. No additional parts are required. Kits are available for Traverse. If replacing T9 see note below. All X2 RL23XX, RL53XX, FT53XX and RT23XX were manufactured with a T5 or T7 EPP beginning January 2, 2008 (Julian date of 08002). All RL1613, and ARGO were manufacturered with a T5 or T7 EPP. If the ATM has been updated from VISA T1 EPP to T7 OR it needs to be updated from a VISA T1 EPP, the applicable kits are available. All XScale RL51XX, RT21XX and FT51XX were manufacturered with VISA T1 EPP beginning December 29, 2004 (Julian date of 04363). Field Installation Instructions are available on www.tritonatm.com. The software must be updated to 3.3.2 or newer. * NOTE* To install the T9 into the Traverse Unit: While holding the T9 EPP Keypad on a slight angle, position the keypad notch over the tab on the mounting bracket. Mounting Bracket Tab Keypad Notch Install the top of the keypad from left to right (from the rear) ensuring the keypad gasket is sitting flush against the control panel. Using slight pressure if needed, ensure the bottom half of the keypad is also sitting flush with the control panel. Secure the keypad with the 6 screws. G-4

T9 KEYPAD Prior to T9 Keypad Activation The Device Status report will indicate if the EPP has been installed correctly into the unit. This is imperative to check prior to activation as if it is not installed correctly, the EPP activation will fail. 1. Log into Management Functions. 2. If Favorites page appears, press 0 - Main Menu. Press 2 - Diagnostics. 3. Press 8 - Keypad. 4. Press 1 Dvice Status. 5. If the T9 EPP Keypad has been installed correctly, the Remove Detector Activated: will read TRUE. If the EPP Keypad is not installed correctly, the Remove Detector Activated: will read FALSE. If FALSE, check that the EPP is correctly aligned in the opening and secured tightly with all six screws. G-5

APPENDIX G To Activate the T9 Keypad NOTE: Activation is NOT required for units that ship with the T9 EPP installed. 1. Log into Management Functions. 2. If Favorites page appears, press 0 - Main Menu. Press 2 - Diagnostics. 3. Press 8 - Keypad. 4. Press 4 - Activate EPP. 5. When the activation is successful, the EPP activation successful message will appear. G-6

T9 KEYPAD To Reactivate the T9 Keypad NOTE: Triton Technical Support CANNOT supply an activation code without the Operator Id, Serial Number and Nonce numbers supplied in Step 5. 1. Log into Management Functions. 2. If Favorites page appears, press 0 - Main Menu. Press 2 - Diagnostics. 3. Press 8 - Keypad. 4. Press 4 - Activate EPP. 5. The following screen will appear. An activation code is required from Triton Technical Support to reactivate the T9 EPP Keypad. Contact Triton Technical Support with the Operator Id, Serial Number and Nonce numbers (supplied in the EPP Activation dialog box) for an activation code. 6. Enter the activation code. Press Enter on the keypad. If the code was entered correctly, the EPP activation successful box will appear. If the code was entered incorrectly, the EPP activation failed box will appear. If failed, repeat steps 4-6 (acquire a new code from Triton Technical Support). G-7

APPENDIX G Replacing the battery in the T9 Keypad NOTE: Do NOT remove the battery from the T9 EPP without FIRST connecting a new battery!! This EPP will be permanently damaged if the battery is removed and the keypad is unpowered before connecting a new battery. 1. Shutdown the unit with the proper shutdown procedures. Turn the power switch on the power supply to the OFF (O) position. 2. Remove the battery cover from the EPP. Set the cover aside for reinstallation. 3. DO NOT UNPLUG CURRENT BATTERY! Obtain a replacement battery. Plug the new battery into the spare battery connection. The spare battery can be ordered at www.atmgurus.com. 4. After the new battery is correctly installed, unplug and remove the old battery. 5. Secure the new battery in the compartment and reinstall the battery cover. G-8