ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Similar documents
ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

Operating voltage Maximum

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

ABB i-bus KNX Binary Inputs BE/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

ABB i-bus KNX Blind/Roller Shutter Actuators JRA/S Product Manual

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Blind/Roller Shutter Actuator JRA/S Product Manual

Electrical devices may only be mounted and connected by electrically skilled persons.

PRODUCT MANUAL. ABB i-bus KNX DG/S x DALI-Gateway Basic

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

ABB i-bus KNX SUG/U 1.1 Split Unit Gateway Product Manual

Product and functional description

Power supply CP-C 24/5.0

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Product and functional description

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Operating Instructions. DALI-Gateway

Miniature Circuit Breakers for Railway Applications

Power supply CP-D 12/2.1 Primary switch mode power supply

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Intrusion Detection Technology SafeKey Switching Module SSM/A, SSM/U Product Manual

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Power supply CP-E 48/1.25 Primary switch mode power supply

Operating and mounting instructions

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Power supply CP-E 24/0.75 Primary switch mode power supply

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

Product and functional description

DC561, digital input/output module,

ABB i-bus KNX Thermoelectric Valve Drive, 230 V TSA/K 230.2, 2CDG R0011

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Redundancy unit CP-A RU

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

PHOENIX CONTACT Features

QUINT-PS/ 1AC/24DC/ 5

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

DC562, digital input/output module,

Operating instructions. Standstill monitor A / / 2011

DI561 Digital Input Module

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Power supply CP-E 24/10.0 Primary switch mode power supply

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

TEPI11 P/I signal converter

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

AI561 Analog Input Module

DX561 Digital Input/Output Module

DI572 Digital Input Module

Messaging module CP-C MM

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

EAE KNX Switch Actuator

DELTA profil wall switch, single UP 241/2 5WG AB_2

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Switching relay CT-IRE with 1 c/o (SPDT) contact

PI-EX-ME-2NAM/COC-24VDC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Product and functional description

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Transcription:

Technical data 2CDC507101D0202 ABB i-bus KNX Product description The ABB i-bus KNX DALI Light Controller DLR/S 8.16.1M is a KNX modular installation device (MDRC) in ProM design for installation in the distribution board on a 35 mm mounting rail. The DALI Light Controller can, in conjunction with the application program Control Dim Groups 8f DALI/1, integrate devices with DALI interfaces into a KNX building installation. The connection to the KNX is implemented via a KNX connection terminal on the device shoulder. The 8 sensor inputs for the Light Sensor LF/U, together with the first 8 lighting groups of the DALI Light Controller, can be used for a constant light control. Up to 64 DALI devices can be connected to the DALI output. The 64 DALI devices should be assigned to 16 lighting groups with the ETS-independent Software Tool. Control of the 64 DALI devices via KNX is exclusively group-oriented. The fault status (lamps and ballasts) of every individual DALI device can be sent via a coded communication object on the KNX. The 16 lighting groups can be integrated into scenes as required. Using 1 bit or 8 bit KNX scene telegrams, these scenes can then be recalled or stored via the KNX. Furthermore, a Master/Slave function with integrated offset is available that can be used to integrate further lighting groups or dimming actuators into the light control. Using central telegrams, all the DALI devices connected to a DALI output can be commonly controlled via the KNX (broadcast). The DLR/S is a DALI control device (master) and requires an AC or DC auxiliary power supply. The DALI power source for the 64 DALI devices is integrated into the DALI Light Controller. In order to control the DALI devices manually or via the KNX, the KNX voltage and the auxiliary voltage (light controller operating voltage) must be applied. Should one of these voltage sources be absent, the DALI devices can no longer be controlled. The reaction of the DALI devices on voltage failure can be parameterized. Individual lighting groups can be switched or dimmed using manual control on the device. Furthermore, the fault for every lighting group is indicated by a yellow LED on the DLR/S. In the DLR/S, a staircase lighting time curve can be set. Constant light control can be combined with a staircase lighting time curve, so that constant light control can be implemented during the staircase lighting time curve.

Technical data Supply Light controller supply voltage 100 240 V AC (+10 %/-15 %) 85 265 V AC, 50/60 Hz 110 240 V DC Power consumption total via mains Maximum 3.5 W at 230 V AC and max. load 1) Current consumption total via mains Maximum 15 ma at 230 V AC and max. load 1) Leakage loss total for device Maximum 1.6 W at 230 V AC and max. load 1) Current consumption KNX Maximum 10 ma Power consumption via KNX Maximum 210 mw DALI output Number of outputs 1 to EN 60 929 and DIN EN 62 386 The DALI output is a fixed 230 V, i.e. unintentional application of the light controller supply voltage will not cause destruction of the DALI output. Number of DALI devices Maximum 64 Number of lighting groups 16 Distance between DLR/S and last DALI device Cable cross-section: 0.50 mm 2 100 m 2) 0.75 mm 2 150 m 2) 1.00 mm 2 200 m 2) 1.50 mm 2 300 m 2) Sensor inputs Light Sensor LF/U 2.1 For detailed information, see Light Sensor LF/U 2.1, page 18 Number of inputs 8 Max. cable length per sensor Per light sensor 100 m, Ø 0.8 mm, P-YCYM or J-Y(ST)Y cable (SELV), e.g. shielded KNX bus cable Connections KNX KNX connection terminal, 0.8 mm Ø, solid DALI outputs and mains voltage Screw terminal: 0.2 2.5 mm 2 fine stranded 0.2 4 mm 2 single core Tightening torque Max. 0.6 Nm Light Sensor LF/U: Wire end ferrule without/with plastic sleeve Without 0.25 2.5 mm 2 / with 0.25 4 mm 2 TWIN ferrule 0.5 2.5 mm 2 Tightening torque Max. 0.6 Nm Brightness detection Lighting control operating range Optimized for 500 Lux. 200 1,200 Lux for rooms with average furnishing level, degree of reflection 0.5 Max. 860 Lux in a very brightly furnished room (reflection 0.7) Max. 3,000 Lux in a very darkly furnished room (reflection 0.2) The Lux values are measured values on the work surface (reference surface) 3) 2 2CDC507101D0203 DLR/S 8.16.1M

Operating and display elements /LED For assignment of the physical address LED LED /LED For switchover between manual operation and KNX operation Switch to next lighting group Switch ON or dim UP Switch OFF or dim DOWN Detect devices Display for operation readiness DALI operating voltage display 16 LED Lighting group 1 16 display Degree of protection IP 54 Compliant to EN 60 529 Protection class II Compliant to EN 61 140 Isolation category Overvoltage categor III to DIN EN 60 664-1 Pollution degree 2 to DIN EN 60 664-1 Atmospheric pressure Atmosphere up to 2,000 m KNX safety extra low voltage SELV 24 V DC DALI voltage Typical 16 V DC (9.5 22.5 V DC) To DIN EN 60 929 and DIN EN 62 386 No-load voltage 16 V DC 4) Lowest supply current at 11.5 V 160 ma Highest supply current 230 ma Temperature range Power -5 C +45 C Storage -25 C +55 C Transport -25 C +70 C Environmental conditions Humidity Maximum 95 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, ProM Dimensions 90 x 108 x 64.5 mm (H x W x D) Mounting width 6 x 18 mm modules Mounting depth 68 mm Mounting On 35 mm mounting rail Compliant to EN 60 715 Installation position Any Weight 0.26 kg Housing, color Plastic housing, halogen-free, gray Approvals KNX to EN 50 090-1, -2 Certification EN 62 386 (Part 101 and 102) DALI CE mark In accordance with the EMC guideline and low voltage guideline 1) Maximum load corresponds to 64 DALI devices at 2 ma each. 2) The length relates to the entire routed DALI control cable. The maximum values are rounded off and relate to the resistance value. EMC influences are not considered. For this reason, the values should be considered as absolute maximum values. 3) Rooms are lit up differently by the incidental daylight and the artificial light of the lamps. Not all the surfaces in the rooms, e.g. walls, floor and furniture, reflect the light which falls on them in the same manner. Accordingly, even though there is an exactly calibrated constant light control in daily operation, deviations to the setpoint value may occur. These deviations may be up to +/- 100 lx, should the current ambient conditions in the room, and accordingly the reflection properties of the surfaces (paper, people, reorganized or new furniture), differ significantly from the original ambient conditions at the time of calibration. Deviations may also occur if the light sensor is influenced by direct or reflected light falling on it, which is not influenced or only slightly influenced by the surfaces in the detection range of the light sensor. 4) Cannot be measured directly on the digital multimeter, as there is not a constant DC voltage due to the DALI telegrams. Measure with a CRO for correct results. One exception is the KNX download phase. In this phase, no DALI telegrams are sent, whereby the DALI voltage is constantly present on the DALI output. DLR/S 8.16.1M 2CDC507101D0203 3

Note The DALI gateway conforms to the SELV properties to IEC 60 364 4 41 (DIN VDE 0100 410). DALI does not need to feature SELV properties, and it is possible to route the DALI control lines together with the mains voltage on a multi-core cable. All-pole disconnection must be ensured in order to avoid dangerous touch voltages which originate from feedback from differing phase conductors. Installation must be performed so that both DALI lines and lines carrying mains voltage are disconnected when an area is disconnected. Device type Application Max. number of Max. number of Max. number of communication objects group addresses associations DLR/S 8.16.1M Control Dim Groups 8f DALI/1* 212 254 255 * = Current version number of the application. Please refer the software information on our website for this purpose. Note For a detailed description of the application see the DALI Light Controller DLR/S 8.16.1M product manual. It is available free-of-charge at www.abb.com/knx. ETS and the current version of the device application are required for programming. Editing with the ETS2 is not possible! The current application can be found with the respective software information for download on the Internet at www.abb.com/knx. After the import to the ETS, the application can be found at ABB/Illumination/Light Controller/Control Dim Groups 8f DALI/1. The device does not support the locking function of a KNX device in ETS. If you use a BCU code to inhibit access to all the project devices, it has no effect on this device. Data can still be read and programmed. 4 2CDC507101D0203 DLR/S 8.16.1M

Connection diagram 2CDC072004F0011 1 Label carrier 9 LED Operation display 2 Programming button 10 LED DALI operating voltage 3 Programming LED (red) 11 LED Manual operation 4 Bus connection terminal 12 Manual operation button 5 DALI output 13 Groups button 6 Light controller supply voltage 14 Detect devices button 7 8 Light Sensor inputs LF/U 2.1 15 ON/UP OFF/DOWN 8 16 LED groups... 16 Light Sensor LF/U 2.1 DLR/S 8.16.1M 2CDC507101D0203 5

Note When positioning the Light Sensor LF/U in the room, it is important to ensure that the individual control circuits cannot interfere with one another. The LF/U should be mounted above the area, in which the actual lighting intensity is measured. The luminaires or sunlight may not shine directly into the brightness sensor. Pay attention to unfavorable reflections, for example, from mirrored or glass surfaces. The white fibre-optic rod can limit the detection range and reduce the lateral lighting sensitivity to external lighting sources. Note If the LF/U is not connected to the DLR/S, a DC voltage of a few mv can be measured directly with a multi-function measurement device. The measured value is between 0 mv (absolute darkness) and a few 100 mv, depending on the brightness. If 0 mv is also measured at normal brightness, this is due to an open circuit, short circuit or inverse polarity fault or a defective sensor. 6 2CDC507101D0203 DLR/S 8.16.1M

Dimensional drawing 2CDC072002F0011 DLR/S 8.16.1M 2CDC507101D0203 7

Contact ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further information and local contacts: www.abb.com/knx Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. The agreed properties are definitive for any orders placed. ABB AG shall not be liable for any consequences arising from errors or incomplete information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Reproduction, transfer to third parties or processing of the content including sections thereof is not permitted without prior expressed written permission from ABB AG. Publication number 2CDC507101D0203 (02/2016) Copyright 2016 ABB All rights reserved