Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Similar documents
Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Allen-Bradley 1492-RIFM20F

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

1492 ACABLE 010 A. Standard m (16.40 ft) ( ft) 0.1 m (0.328 ft increments) m ( ft) 0.5 m (1.

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Allen-Bradley 1492-IFM40F

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

Bulletin 1746 Digital 32-Point I/O Modules (Continued)➋

1492 CABLE 010 A Bulletin 1492 Programmable Controller Wiring Systems Catalog Number Explanation

Bulletin 700H and 700S Description SLC 500 ControlLogix MircoLogix 1200 MicroLogix 1500 CompactLogix Flex PLC-5 PowerFlex Drive Product Selection

1492 XIM RF. No. Cable Connector Pins pins pins. Expander module. Module Type (all types do not configure a catalog number)

Bulletin 1492 Programmable Controller Wiring Systems Overview. Digital Relay Expander (16 Outputs) with Fusing

1492 XIM RF. No. Cable Connector Pins pins pins. Expander module. Module Type (all types do not configure a catalog number)

1746-IV32 24V DC 32 Current Sourcing DC Input Module 1746-ITV16 24V DC 16 Fast Response DC Sourcing Input Module

Allen-Bradley Replacements

8 System Overview. Notes:

Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections

Select SLC 500 I/O Modules

Select SLC 500 I/O Modules

SLC 500 System Overview

POINT I/O Family. Chapter. Overview

AB Spares. PanelConnect Module for Sensor Connection To Programmable Controller. Technical Data

SLC 500 System Overview

Modicon 800 to ControlLogix Bulletin 1756 I/O Field Wiring Conversion System. Selection Guide

FLEX Ex Spring Clamp Terminal Base

Analog RTD and Thermocouple Modules. Analog Output Modules. Select a ControlLogix System

PanelView Plus/VersaView CE Terminals and Display Modules

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module

Bulletin 1492 I/O Wiring Conversion Systems - PLC to ControlLogix 1756 Product Overview

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Cat. No. (Spring Clamp. Input Voltage

Installation Instructions

em4 Accessories Digital expansions

Installation Instructions

Digital IFMs are available with either a 20- or 40-pin cable connector. This is determined by the number of connections required for the I/O module.

POINT I/O Family. Chapter. Overview

Allen-Bradley 700-K40E-DJ

ControlLogix Digital I/O Modules

Bulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram

Installing Your 1394 Drive Interface Module

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

ControlLogix Digital I/O Modules

ControlLogix Digital I/O Modules

About the FLEX I/O and FLEX Ex I/O Systems

CompactLogix Power Supplies Specifications

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

CompactBlock Guard I/O EtherNet/IP Safety Modules

Select a ControlLogix System

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Redundancy unit CP-A RU

TF501, TF521 Terminal Bases

Installation Instructions

5 MICROMASTER 440 specifications

ETD-BL-1T-OFF-CC- 10S

General Specifications. P2-08THM Analog Input

16-Channel Digital Input Termination Card 24Vdc

VersaMax* Analog Input, 16-Bit Thermocouple Module

Analog Input, 16-Bit Thermocouple Module

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

TU531, TU532 Terminal Unit

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

SITOP in the SIMATIC Design

5 MICROMASTER 420 specifications

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

16-Channel Input Digital Input Termination Card

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

ALLEN BRADLEY RELAY Bulletin 700-HF

AO523 Analog Input Module

ex-s1110-xt Gigabit Ethernet Extenders

Remote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)

Analog Voltage Combination Module

5504 Thermocouple Analog Input Module

ArmorPoint I/O Field Potential Distributor, Series A

Device-Level Ring Topology

1769 Compact I/O Communication Bus Expansion Cables

Allen-Bradley 1492-RCDA4A40

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Stride Industrial Ethernet Switches

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

1734 POINT I/O POINT I/O. Benefits. Product Design. POINT I/O System Components

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

24 Input/8 Output AC Block I/O Module

1492-SP Supplementary Protectors

AI531 Analog Input Module

ControlLogix Redundant Power Supply Chassis Adapter Module

Digital Lighting Systems, Inc.

Installation Instructions

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

Transcription:

Bulletin Overview Analog Wiring Systems Digital Wiring Systems with Field-Removable Terminal Blocks Analog Wiring Systems Digital Wiring Systems with Fixed Terminal Blocks Bulletin Increases machine building productivity Simplifies design and engineering time Reduces wiring time and wiring errors Benefits from quality-looking panels Standards Compliance and Certifications Agency Certifications for Modules and Cables culus: Hazardous Locations: Class I Div (all except modules with relays); Groups A, B, D, and D. Temperature : TC @ C. UL File No. E, Guide No. NRAG culus: Ordinary Locations; Module with relays; UL File No. E Guide No. NRAQ Agency Certification Modules Factory Mutual (FM): Hazardous Locations; Class I Div (all except modules with relays): Gouprs A, B, C, and D. Temperature Rating: TC @ C. FM file J.I. CE Certifications Compliant for all applicable directives Table of Contents Catalog Number Explanation... - Selection Tables... - Digital IFM Specifications... - Standards Compliance and Certifications, Continued UL UL CSA C. No. CSA C. No. EN/IEC - Bulletin Bulletin H and S SLC ControlLogix MircoLogix MicroLogix CompactLogix Flex PLC- PowerFlex Drive Product Selection Web - - - - - Web - Information for this product is available on the Industrial Controls Catalog website: Publication A-CAA-EN-P -

Bulletin Catalog Number Explanation/Overview Analog Interface Modules (AIFMs) General Information Analog AIFMs are available with either - or -pin D-Shell connections. This is determined by the number of connections that are required by the I/O module. Important: The following AIFM Cat. No. breakdown is for explanation purposes only. It is not a product configurator. Not all combinations of fields are valid product cat. nos. Use this breakdown for verification and explanation only. AIFM RAIFM TAIFM a Modules Analog Interface Module with Fixed Terminal Block Analog Interface Module with Removable Terminal Block Analog Interface Module for SIL (Safety Integrity Level ) AIFM F a b c b Module Type (all types do not configure a catalog number) channel C Combination CE Counter Encoder channel channel channel F Fused Number of Field Side Wiring Terminals Three per I/O channel Five per I/O channel c Analog Interface Modules (AIFMs) Feed-Through Feed-through IFMs provide the same capability as normal terminal blocks but in a more condensed package. Standard terminal IFMs provide three field-side wiring terminals per programmable controller analog input or output point, which includes enough terminals for the device shield and power connections. Standard Terminal -channel: Cat. No. -AIFM- Isolated Standard Terminal -channel IFM with connections: Cat. No. -AIFMS-, -AIFM- Standard Terminal -channel for -wire sensor devices: Cat. No. -AIFM- Safety Integrity Level (SIL ) Cat. No. -TAIFM-F- - Publication A-CAA-EN-P

Bulletin Overview Analog Interface Modules (AIFMs) Fusible Fusible analog interface input modules provide a convenient method to fuse the input power source on the field side. The field-side power source is distributed through individual on-board x fuse holders. The AIFMs have a V DC blown fuse indicators to reduce the troubleshooting time required to locate and replace a blown fuse. Fusible modules have an easy-to-remove transparent plexiglass cover to prevent objects from contacting fuse circuitry under normal operation. Standard fuse holders reside in the IFM, aiding in the removal of a fuse with a fuse puller (fuses are not included). Isolation switch plugs, or dummy fuses, are also available to isolate an input circuit once power is removed. In addition, once the circuit has been isolated and power restored, the input loop current can be measured in -wire transmitter applications. The fusible modules also have three or five terminals per I/O analog input point to create a power bus for device shield and power connections. Fused -channel module with V blown fuse indication, test points and terminals per input: Cat. No. -AIFMI-F- -channel input module with V blown fuse indication and terminals per input: Cat. No. -AIFM-F- Analog Fused Products Cat. No. -AIFMC-F-, -AIFMF-F-, -AIFM-F-, -AIFM-F-, -AIFM-F- Analog Interface Modules (AIFMs) Thermocouple Fused -channel module with V blown fuse indication, test points and terminals per input: Cat. No. -AIFM-F- -channel input module with V blown fuse indication and terminals per input The Cat. No.-AIFMTC- Thermocouple IFM for the Cat. No. -ITI or -ITI ControlLogix I/O module provides on-board cold junction compensation to allow thermocouples to be connected remotely while still correcting for temperature at the termination point. The combination thermistor and isothermal bar acquire temperature data at the AIFM for the thermocouple to adjust the input value. Thermocouple -channel module with isothermal bar and terminals per output: Cat. No. -AIFM-TC- Publication A-CAA-EN-P -

Bulletin Catalog Number Explanation Analog Cables Pre-Wired Bulletin pre-wired cables are designed to minimize control wiring in a panel. Pre-wired cables, when used with an analog IFM, replace the point-to-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The pre-wired cables have a removable terminal block or wiring arm from the PLC on one end of the cable and a D-Shell connector with a slide-locking mechanism on the other to connect to the IFM. Most pre-wired cables use twisted pairs and all have shield to aid noise immunity of the low-level analog signals. Most cables have a prepared drain wire with a ring lug at the I/O module end of the cable for convenient grounding of the cable shield to the chassis. They are % tested for continuity to make a perfect connection every time. The analog pre-wired cables are offered in four standard lengths of.,.,., and. m to fit a variety of applications. Other length cables are also available as build-to-order products. Pre-wired analog cables are available for many of the Bulletin SLC I/O, Bulletin ControlLogix I/O, Bulletin Compact I/O for CompactLogix, MicroLogix, Flex I/O, and Bulletin PLC- I/O Analog Cables I/O Ready - Not Available Analog Cables IFM Ready - Not Available Cat. No. Explanation Analog Cables for Bulletins, /, and Important: Use tables as a product configurator for pre-wired, IFM-ready, and I/O module-ready cables for Bulletins,, and digital I/O module cables. All combinations of these fields make valid product cat. nos. Refer to selection tables for IFM/XIM compatibility, additional cables, and ordering. - a Analog Interface Cables Cat. No. Explanation Analog Cables for Bulletin,, H/S and a Analog Interface Cables Important: For explanation purposes only. It is not a product configurator. All combinations of fields are not valid product cat. nos. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems in publication -TD_- EN-P. Then, use this breakdown for verification and explanation only. ACABLE A a b c b Standard or Build-to-Order Length Cable. m (. ft). m (. ft). m (. ft) Standard. m (. ft).. m - (.. ft). m (. ft increments) -.. m (.. ft). m (. ft) increments Build-to-Order -.. m (.. ft). m (. ft) increments ACAB A a b c b Standard or Build-to-Order Length Cable. m (. ft). m (. ft). m (. ft) Standard. m (. ft).. m - (.. ft). m (. ft increments) -.. m (.. ft). m (. ft) increments Build-to-Order -.. m (.. ft). m (. ft) increments Publication A-CAA-EN-P A, B, C, D, K, L, P, Q, R E, F, G, H, J TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z, ZA, ZB, ZC YT M A AA, AB, BA, BB, BC, BD, C,CA, CB, CC, D, EA, EB, EC, ED ZH XS, ZS Z c A-Cable Type Pre-wired cables for Bulletin analog and RTD I/O Pre-wired cables for Bulletin analog and RTD I/O Pre-wired cables for Bulletin analog, RTD, and thermocouple I/O Pre-wired cable for Bulletin thermocouple I/O Pre-wired cables for Bulletin pulse input I/O modules c Cable Type Analog cable for SLC Analog cable for I/O Analog cable PowerFlex H Analog cable PowerFlex S Analog cable for Flex I/O

Bulletin Overview Digital IFM Modules with Field-Removable Terminal Blocks (RTBs) Select groups of standard, fused and relay digital wiring system modules (refer to Selection Tables) have field terminal blocks that can be removed (RTB). This RTB feature can provide easier wiring of field devices in a control cabinet where the IFM is located in a hard to reach area, or where hand-access is limited. It can also provide easier and faster replacement of a damaged or defective wiring system module. The removable plug portion of the RTB assembly has a screw at each end to securely fasten it to the RTB socket, which is mechanically secured to the module circuit board hand housing. Modules are shipped with the RTB socket, but without the removable plug(s). Plugs are available with screw style (e.g., -RTBN)or push-in style (e.g., - RTBP) terminals and must be ordered separately(two pieces per cat. no.). Refer to the selection tables for the particular PLC I/O system of interest to determine which modules are offered with field removable terminal blocks. All of the features available on fixed terminal block products (e.g. labels, agency certification, etc.) are also provided for the removable terminal block wiring system Analog AIFM Modules with Field-Removable Terminal Blocks (RTBs) Select groups of analog wiring system modules (refer to Selection Tables) have field terminal blocks that can be removed (RTB). This RTB feature can provide easier wiring of field devices in a control cabinet where the IFM is located in a hard to reach area, or where hand-access is limited. It can also provide easier and faster replacement of a damaged or defective wiring system module. The removable plug portion of the RTB assembly has a screw at each end to securely fasten it to the RTB socket, which is mechanically secured to the module circuit board and housing. Modules hare shipped with the RTB socket, but without the removable plug(s). Plugs are available with screw style (- RTBxxN) or push-in style (-RTBxxP) terminals and must be ordered separately (Two pieces per cat. no.). Refer to the Selection Tables for the particular PLC I/O system of interest to determine which modules are offered with field Removable Terminals Blocks. All of the features available on analog fixed terminal block products (e.g. labels, agency certification, etc.) are also provided for the removable terminal block wiring system Catalog Number Explanation RTB Plugs Important: The following cat. no. breakdown is for explanatory purposes only. It is not a product configurator. Not all combinations of fields are valid cat. nos. Use this breakdown for verification and explanation only. a Removable Terminal Block Plug Selecting a Wiring System Use of Selection Tables RTB N a b c b Number of Poles/Terminal N P c Connector Style Screw Style Push-in Style Locate I/O module required. The top row indicates the I/O module for the I/O platform. Locate the interface module required. The second and third column indicates the interface module catalog number. Determine if an interface module exists for the I/O module; indicated by Letter in row (interface catalog number) and the column (I/O module). Locate cable. This is the letter indicated by Letter in the row (interface catalog number) and the column (I/O module). The Letter represents the suffix of the pre-wired cable. Determine cable catalog number. Add -CABLE _ Letter, example -CABLE _A. Determine length of cable required, standard lengths are.,.,., and. m; which represents,, and for _ in the cable catalog number. Example -CABLEA = a. m cable with Letter A. Publication A-CAA-EN-P -

Bulletin Bulletin ControlLogix Modules Digital IFMs and Cables for Bulletin ControlLogix -point Isolated and -point I/O Modules Voltage [V]... Term. per I/O Fixed Terminal Block Removable Terminal Block RTB Plugs -IAI -IBD -IBI -IA Bulletin ControlLogix I/O Module Cat. No. Cat. No. Cat. No. Digital Cable Cat. No. Suffix Feed-through Standard -IFMF -RIFMF -RTB Y Y Y Z Z Z Y Y Y Y Y Y Z Z Y Y Y Extra Terminals -IFMF- -RIFMF- -RTB Y Z Z Z Y Z Z Sensor -IFMF- Z Z Indicating Standard -IFMD -RIFMD -RTB Z Z Z Z Extr.Term. -IFMD- Z Z Extr.Term. -IFMDA- -RIFMDA- -RTB Z Z Sensor -IFMD- Z Z Isolated -IFMDS- Y Y Y Y Y Y Isolated Extr.Term. -IFMDSA- Y Y -IFMDA- Z Isolated -IFMDS- Y Y Y...... Isolated Isolated Extra Terminals -IFMDSA- Y -IFMDSA- Y Fusible -IFMF-F- -RIFMF-F- -RTB Z Z -IFMF-FD- Y -IFMF-FAD- Y -IFMF-F- Z Z Fusible - Isolated Extr. Term. -IFMF-FS- Y Y Y Y Y -IFMF-FS- Y Y Y Y Y -IFMF-FSA- Y Extr. Term. -IFMF-FS- Y Y Y Y Y Y Y Y Extr. Term. -IFMF-FS- Y Y Y Y Y Y Y See footnotes on the following page. -IFMF-FSA- Y Y Y Y -IFMF-FS- -RIFMF-FS- -RTB Y Y Y Y -IFMF-FS- -RIFMF-FS- -RTB Y Y Y -IFMF-FSA- -RIFMF-FSA- -RTB Y Y -IFMF-FS- Y Y Y -IFMF-FSA- Y Safety Integrity Level (SIL) -TIFMF-FA- Z Z -TIFMF-- Y -IB -IV -IHI -IMI -OAI -OBEI -OBD -OBI -OBIS -OB -OVE -OHI -OWI -OXI - Publication A-CAA-EN-P

Bulletin Specifications Digital IFM Specifications - Digital IFM Cat. No. Voltage Range Dimensions (W x H x D) [in.] Indicator Circuit Current (Nominal) [ma] Label Card Cat. No. -IFMF, -RIFMF V AC/DC. x. x. --, -- -IFMFN, -RIFMFN V AC/DC. x. x. --, --, -- -IFMF-, -RIFMF- V AC/DC. x. x. --, --, -- -IFMF- V AC/DC. x. x. -- -IFMD V AC/DC. x. x. --, -- -IFMDN V AC/DC. x. x. --, --, -- -IFMD- V AC/DC. x. x. --, --, -- -IFMDA- V AC/DC. x. x. -- -IFMDS- V AC/DC. x. x.. -- -IFMD- V AC/DC. x. x. --, -- -IFMD V AC/DC. x. x.. --, -- -IFMDN V AC. x. x.. --, --, -- -IFMD- V AC. x. x.. --, -- -IFMDA- V AC. x. x.. -- -IFMDS- V AC. x. x.. -- -IFMD- V AC. x. x.. --, -- -IFMDA- V AC. x. x.. -- -IFMF-F-, -RIFMF-F- V AC/DC. x. x. --, --, -- -IFMF-F-, -RIFMF-F- V AC/DC. x. x. --, --, -- -IFMF-FA-, -RIFMF-FA- V AC/DC. x. x.. --, -- -IFMF-F-, -RIFMF-F- V AC. x. x.. --, --, -- -IFMF-FA-, -RIFMF-FA- V AC/DC. x. x.. --, -- -IFMF-F- V AC. x. x.. --, -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FSA- V AC/DC. x. x.. -- -IFMF-FS- V AC/DC. x. x.. -- -IFMF-FS- V AC/DC. x. x.. -- -IFMF-FSA- V AC/DC. x. x.. -- -IFMF-FS- V AC. x. x.. -- -IFMF, -RIFMF V AC/DC. x. x. --, --, -- -IFMF- V AC/DC. x. x. --, --, --, --, -- -RIFMF- V AC/DC. x. x. --, --, --, --, -- -IFMF- V AC/DC. x. x. --, -- -IFMD, -RIFMD V AC/DC. x. x. --, --, -- -IFMD- V AC/DC. x. x. --, --, -- -IFMDA- V AC/DC. x. x. --, --, --, --, -- -RIFMDA- V AC/DC. x. x. --, --, --, --, -- -IFMDS- V AC/DC. x. x.. -- -IFMDSA- V AC/DC. x. x.. -- -IFMD- V AC/DC. x. x. --, -- -IFMD- V AC. x. x.. --, --, -- -IFMDA- V AC. x. x.. --, --, - -IFMDS- V AC. x. x.. -- -IFMDSA- V AC. x. x.. -- -IFMDSA- V AC. x. x.. -- -IFMF-F- V AC/DC. x. x. --, --, -- -IFMF-F- V AC/DC. x. x. --, --, --, --, - -RIFMF-F- V AC/DC. x. x. --, --, --, --, - -IFMF-FD- V AC/DC. x. x. <. -- -IFMF-FAD- V AC/DC. x. x. <. -- -IFMF-F- V AC. x. x.. --, --, -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x. -- -IFMF-FS- V AC/DC. x. x.. -- -IFMF-FS-, -RIFMF-FS- V AC/DC. x. x.. -- -IFMF-FS- V AC/DC. x. x.. -- -RIFMF-FS- V AC/DC. x. x.. -- -IFMF-FS- V AC/DC. x. x.. -- -IFMF-FSA- V AC/DC. x. x.. -- -IFMF-FSA- V AC/DC. x. x.. -- -RIFMF-FSA- V AC/DC. x. x.. -- -IFMF-FSA- V AC/DC. x. x. -- -IFMF-FSA- V AC/DC. x. x.. -- -TIFMF-F- V DC. x. x. -- -TIFMF-FA- V DC. x. x. -- To convert to millimeters, multiply inches by. Ships with each module. For spare part, precede the part number with the letter "W." Add. in. to the width dimension for Bulletin -Rxxx Publication A-CAA-EN-P

Bulletin Specifications General Wiring System Specifications Agency Certifications: Modules and Cables Agency Certification Modules CE Certifications Catalog Number -... culus Listed: Hazardous Locations: Class I Div (all except modules with relays); Groups A, B, D, and D. Temperature : TC @ C. Standard UL File No. E, Guide No. NRAG/NRAG culus Standard Locations; Module with relays; UL File No. E, Guide No. NRAQ/NRAQ Factory Mutual (FM): Hazardous Locations; Class I Div (all except modules with relays): Groups A, B, C, and D. Temperature Rating: TC @ C. FM File J.I. Compliant for all applicable directives Maximum Peak Transient Voltage V Maximum Current (per circuit) A (except relays) Maximum Current (per module) A (except relays) Terminal Block Wire Range (Rated Cross Section) Wire Strip Length Recommended Terminal Block Screw Tightening Torque Fixed Screw Style: # # AWG (... mm) Removable Screw Style: # to # AWG... mm) Removable Push-in Style: # to # AWG (...mm) Fixed Screw Style:. in. (. mm) Removable Screw Style:. in. (. mm) Removable Push-in Style:. in. (. mm) Fixed Screw Style:.. lb-in. (.. Nm) Removable Screw Style:.. lb-in. (.. Nm) Removable Push-in Style: NA (See Push-in RTB Plug Specifications) Operating Temperature Range...+ C Storage Temperature Cables -...+ C Storage Temperature Modules -...+ C Operating Humidity Pollution Degree % non-condensing Max. AWG # # # # # # Max. No. of Wires per Terminal Cat. Nos. -IFMF-FAD- and -IFMF-FD- are rated at A. Maximum number of the same gauge stranded copper conductors allowed per wire funnel. Pollution Degree is an environment where normally only non-conductive pollution occurs, except for occasional temporary conductivity caused by condensation shall be expected. For transients >V, use UL Recognized suppression device rated at. kv withstand. For relay contact ratings, refer to page -. - Publication A-CAA-EN-P