VDS Series PC Oscilloscopes Quick Guide

Similar documents
Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Economy Single Channel Output DC Power Supply

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

General Warranty. For more details, please refer to the user manual, it can be downloaded at

ODP Series Linear Programmable DC Power Supply User Manual

Instructions. P MHz 10X Passive Probe

ODP Series Dual Output Linear Programmable DC Power Supply User Manual

General Warranty. For more details, please refer to the user manual, it can be downloaded at

ODP3031 Linear Programmable DC Power Supply User Manual

DS1000B Series Digital Oscilloscope

99 Washington Street Melrose, MA Phone Toll Free Visit us at

XSA1000 Series Spectrum Analyzer Quick Guide

User s Guide DSO-5200 USB PC Based Digital Oscilloscope Operation Manual

General Warranty. For more details, please refer to the user manual, it can be downloaded at

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

USER S MANUAL Linear Programmable DC Power Supply APS

Model P4025T. 200MHz Digital Storage Oscilloscope. With Touchscreen. Quick-Start Guide

User s Guide Tenma USB PC Based Digital Oscilloscope Operation Manual

2019 RIGOL (SUZHOU) TECHNOLOGIES INC.

2016 SIGLENT TECHNOLOGIES CO.,LTD

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence

9040/9040UK. Users Manual. Phase Rotation Indicator

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence

DSO3062A Oscilloscope, 60 MHz

POCKET MULTIMETER Model No: MM18

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

OX 5022-CK OX 5042-CK

User's Guide. Phase Sequence and Motor Rotation Tester Model

38 MHz Passive Voltage Probe R&S RT-ZP1X

Bluetooth/USB Data Logger USER S MANUAL. Hantek 365A/B/C/D/E/F V

WaveAce Series Oscilloscopes

SSA3000X Series Spectrum Analyzer. Quick Guide

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

True RMS AC Voltage/Current Datalogger

DM3058/DM3058E Digital Multimeter

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

ENGLISH. User manual.

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

TCP305A & TCP312A AC/DC Current Probes Instructions

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Keysight U1602B and U1604B Handheld Digital Oscilloscopes

LeCroy PP009 Passive Probe Instruction Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Model VT120 Fast Timing Preamplifier Operating and Service Manual

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

TVAC25100 TVAC25110 User manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TETRIS 2500 High Impedance Active Probe. Instruction Manual

KHT 6000 C HV-Probe Calibrator. Instruction Manual

HX1 Bluetooth Stereo Headset

DS-1H05 Ethernet-over-Coax Extender. User Manual

User's Guide. Extech AM A AC Analog Clamp Meter

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Model High Precision Quad Output DC Power Supply

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

PCI-express data acquisition card DAQ0504M User Guide

PMT 221A High Impedance Passive Probe. Instruction Manual

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

LeCroy PP008 Passive Probe Instruction Manual

Model 7705 Control Module

User Guide True RMS Multimeter Extech EX205T

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

Digital Storage Oscilloscope

User s Guide. LA5034 Operation Manual

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

1. Safety Precautions (Read these precautions before use.)

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

HV-CS kv Edge Mount Triaxial Jack

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0

1-36V, 0-3A DC Power Supply

Mini Digital Multimeter

Model 2657A-LIM-3 LO Interconnect Module

OWNER S MANUAL CD-2 V 1.3

Quick Start/Installation Guide

Various regulation agencies require us to bring the following information to your attention. Please read carefully.

PML 791-RO Low-Z Passive Probe. Instruction Manual

Mini Digital Multimeter Model MN15. User's Guide

Antenna Distributor ORDERCODE D1444

TA MHz Oscilloscope Probe USER S GUIDE

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

Model 2380 Rack-Mount Kit

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Transcription:

VDS Series PC Oscilloscopes Quick Guide WWW.OWON.COM

Mar. 2015 edition V1.2.4 Copyright Lilliput Company. All rights reserved. The Lilliput's products are under the protection of the patent rights, including ones which have already obtained the patent rights and those which are applying for. The information in this manual will replace all that in the materials published originally. The information in this manual was correct at the time of printing. However, will continue to improve products and reserves the rights to change specification at any time without notice. is the registered trademark of the Lilliput Company. Fujian Lilliput Optoelectronics Technology Co.,Ltd.: The Mansion of Optoelectronics, No.19, Heming Road, Lantian Industrial Zone, Zhangzhou, Fujian, China Tel:+86-596-2130430 Web: www.owon.com Fax:+86-596-2109272 Mail: service@owon.com.cn

General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years from the date of purchase of the product by the original purchaser from the Lilliput Company. And the warranty period of accessories such as probe is 12 month. This warranty only applies to the original purchaser and is not transferable to the third party. If the product proves defective during the warranty period, Lilliput either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Lilliput for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Lilliput. In order to obtain service under this warranty, Customer must notify Lilliput of the defect before the expiration of the warranty period. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Lilliput, and with a copy of customer proof of purchase. This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Lilliput shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Lilliput representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-lilliput supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product. Please contact the nearest Lilliput's Sales and Service Offices for services or a complete copy of the warranty statement. For better after-sales service, please visit www.owon.com and register the purchased product online. Excepting the after-sales services provided in this summary or the applicable warranty statements, Lilliput will not offer any guarantee for maintenance definitely declared or hinted, including but not limited to the implied guarantee for marketability and special-purpose acceptability. Lilliput should not take any responsibilities for any indirect, special or consequent damages. For more detailed information, please see the help document of the software, you can open it by pressing F1 in the window of software.

Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols... 2 3. Ports Introduction... 5 VDS1022(I) / VDS2052(I)... 5 VDS2062(L) / VDS3102(L)... 6 VDS2064(L) / VDS3104(L)... 7 4. How to Implement the General Inspection... 8 5. How to Connect with PC... 8 6. How to Implement the Function Inspection... 9 7. How to Implement the Probe Compensation... 9 8. How to Use the Probe Safely... 10 9. Performance parameters... 12 10. Appendix... 14 Appendix A: Enclosure... 14 Appendix B: General Care and Cleaning... 14 i

1. General Safety Requirements Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage. In order to avoid any contingent danger, this product is only used within the range specified. Only the qualified technicians can implement the maintenance. Pay attention to the nominal values of all terminals: To avoid fire or electric shock, please keep a watchful eye on all nominal values and marks specified for this product. Before any connection performed on this product, carefully read the user's manual of the product for further information of nominal values. No touch is allowed on bare conductors: When the product is powered on, do not touch any bare joints or parts of the scope meter. Operation is prohibited in case of any undetermined failure: When in doubt any damage on this product, consult the qualified personnel for checking on it. Keep ventilation in good condition: Refer to the user manual for detail installation instructions in order to fix this product correctly and provide it with good ventilation conditions. No operation is allowed under a humid environment. No operation is allowed under an explosive environment. Keep clean and dry on the product surface. The method which stipulated according to the factory does not use the equipment, possibly can damage the protection which the equipment provides. 1

2. Safety Terms and Symbols Safety Terms Terms in this manual. The following terms may appear in this manual: Warning: Warning indicates the conditions or practices that could result in injury or loss of life. Caution: Caution indicates the conditions or practices that could result in damage to this product or other property. Terms on the product. The following terms may appear on this product: Danger: It indicates an injury or hazard may immediately happen. Warning: It indicates an injury or hazard may be accessible potentially. Caution: It indicates a potential damage to the instrument or other property might occur. Safety Symbols Symbols on the product. The following symbol may appear on the product: Hazardous Voltage Refer to Manual Protective Earth Terminal Chassis Ground Test Ground 2

To avoid body damage and prevent product and connected equipment damage, carefully read the following safety information before using the test tool. This product can only be used in the specified applications. Warning: To avoid fire or electrical shock, please use proper power adapter. Use only the power adapter appointed by the manufacturer and subject to approval of being used in the user's country. Warning: The two channels of the oscilloscope are non-isolated electrically. The channels should adopt common basis during measuring. To prevent short circuits, the 2 probe ground must not be connected to 2 different non-isolated DC level. Warning: The channels should adopt common basis during measuring. To prevent short circuits, the 2 probe ground must not be connected to 2 different non-isolated DC level. The diagram of the oscilloscope ground wire connection: Probe Oscilloscope AC Adapter Electrical Outlet Signal Input Ground Clip The diagram of the ground wire connection when the oscilloscope powered by PC USB is connected to the AC-powered PC through the USB ports: Probe Oscilloscope (PC USB power) PC Electrical Outlet Signal Input Ground Clip USB Cable It is not allowed to measure AC power when the oscilloscope is AC powered through the adapter, or when the oscilloscope powered by PC USB is connected to the AC-powered PC through the ports. Warning: To avoid fire or electrical shock if a test tool input is connected to more 42V peak (30Vrms) or on circuits of more than 4800VA: Use only insulated probes and adapter supplied with the test tool, or indicated by OWON as suitable for the Oscilloscope. Before use, inspect probes and accessories for mechanical damage and replace when damaged. Remove all probes and accessories that are not in use. 3

Do not apply voltages that differ more than 40 V from earth ground to any input when measuring in a CAT Ⅱ environment. Do not apply voltages that differ more than 40 V from each other to the isolated inputs when measuring in a CAT Ⅱ environment. Do not apply input voltages above the rating of the instrument Use caution when using 1:1 test leads because the probe tip voltage will be directly transmitted to the Oscilloscope. Do not touch the exposed part of metal BNC. Do not insert metal objects into connectors. Always use the Oscilloscope only in the manner specified. Voltage ratings that are mentioned in the warning are giver as limits for "working voltage". The represent V ac rms (50 60 Hz) for AC sine wave applications and as V dc for DC applications. Overvoltage Category Ⅱ refers to local level, which is applicable for appliances and portable equipment. 4

3. Ports Introduction VDS1022(I) / VDS2052(I) 1 2 3 4 5 Figure 3-1 Ports of the Oscilloscope 1. USB port: Supply power by PC USB or the adapter; communicate with PC 2. Probe Compensation: Measurement signal (5 V / 1 khz) output 3. MULTI port: EXT trigger input, trigger output or Pass/Fail output 4. Signal input of Channel 2 5. Signal input of Channel 1 5

VDS2062(L) / VDS3102(L) 1 2 3 4 5 6 Figure 3-2 Ports of the Oscilloscope (take VDS3102(L) for instance) 1. USB port: Supply power by PC USB or the adapter; communicate with PC 2. LAN port (optional): Network port which can be used to connect with PC 3. Probe Compensation: Measurement signal (3.3 V/1 khz) output 4. MULTI port: EXT trigger input, trigger output or Pass/Fail output 5. Signal input of Channel 2 6. Signal input of Channel 1 Note: If you use LAN port to communicate with PC, the oscilloscope should be powered by the adapter. 6

VDS2064(L) / VDS3104(L) 1 2 3 4 6 7 8 9 5 Figure 3-3 Ports of the Oscilloscope (take VDS3104(L) for instance) 1. Probe Compensation: Measurement signal (3.3 V/1 khz) output 2. MULTI Connector (optional): Connect Q9 cable with the MULTI port 3. MULTI port: EXT trigger input, trigger output or Pass/Fail output 4. LAN port (optional): Network port which can be used to connect with PC 5. USB port: Supply power by PC USB or the adapter; communicate with PC 6. Signal input of Channel 4 7. Signal input of Channel 3 8. Signal input of Channel 2 9. Signal input of Channel 1 Note: If you use LAN port to communicate with PC, the oscilloscope should be powered by the adapter. 7

4. How to Implement the General Inspection After you get a new VDS series oscilloscope, it is recommended that you should make a check on the instrument according to the following steps: 1. Check whether there is any damage caused by transportation. If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests. 2. Check the Accessories The supplied accessories have been already described in the "Appendix A: Enclosure" of this Manual. You can check whether there is any loss of accessories with reference to this description. If it is found that there is any accessory lost or damaged, please get in touch with the distributor of Lilliput responsible for this service or the Lilliput's local offices. 3. Check the Complete Instrument If it is found that there is damage to the appearance of the instrument, or the instrument can not work normally, or fails in the performance test, please get in touch with the Lilliput's distributor responsible for this business or the Lilliput's local offices. If there is damage to the instrument caused by the transportation, please keep the package. With the transportation department or the Lilliput's distributor responsible for this business informed about it, a repairing or replacement of the instrument will be arranged by the Lilliput. 5. How to Connect with PC 1. Install the Software Install the software on the supplied CD (*.exe). 2. Double-click the created desktop shortcuts. Model VDS1022(I)/ VDS2052(I) VDS2062(L)/VDS3102(L) VDS2064(L)/VDS3104(L) Shortcut VDS_C2 VDS_S2 VDS_S4 3. Connection Use the supplied USB cable to connect the USB port of the Oscilloscope in Ports Introduction to the USB port of a PC. Note: If you use a USB cable which is not supplied by us, some problems such as connection error and signal disturbing might occur. 4. Install the USB driver 8

In the window of software, press F1 to open the help document of the software. Follow the steps of title "I. PC Software USB Driver Install Guide" in the document to install the driver. 6. How to Implement the Function Inspection Make a fast function check to verify the normal operation of the instrument. First, connect the oscilloscope with PC successfully, and then do the following steps: 1. Click in the software interface to restore to factory settings. The default attenuation coefficient set value of the probe in the software is 10X. 2. Set the Switch in the Oscilloscope Probe as 10X and Connect the Oscilloscope with CH1 Channel. Align the slot in the probe with the plug in the CH1 connector BNC, and then tighten the probe with rotating it to the right side. Connect the probe tip and the ground clamp to the connector of the probe compensator. 3. Click on the right top of the software interface to auto set. The square wave of 1 khz frequency and 3.3V peak-peak value will be displayed. (The peak-peak value is 5V with VDS1022(I) and VDS2052(I).) 4. Check CH2 by repeating Step 2 and Step 3. (VDS2064(L)/VDS3104(L) needs to continue to check CH3 and CH4). 7. How to Implement the Probe Compensation When connect the probe with any input channel for the first time, make this adjustment to match the probe with the input channel. The probe which is not compensated or presents a compensation deviation will result in the measuring error or mistake. For adjusting the probe compensation, please carry out the following steps: 1. Click in the software interface to show the function menu, choose "Channel". Click to select "CH1", set the "Probe Rate" in the menu as 10. Set the switch in the probe as 10X and connect the probe with the CH1 channel. If a probe hook tip is used, ensure that it keeps in close touch with the probe. Connect the probe tip with the signal connector of the probe compensator and connect the reference wire clamp with the ground wire connector of the probe connector, and then click on the right top of the software interface to auto set. 9

The set values of the probe switch are 1X and 10X Figure 7-1 Attenuation Switch 2. Check the displayed waveforms and regulate the probe till a correct compensation is achieved (see Figure 7-2 and Figure 7-3). Overcompensated Compensated correctly Under compensated Figure 7-2 Displayed Waveforms of the Probe Compensation 3. Repeat the steps mentioned if needed. Figure 7-3 Adjust Probe 8. How to Use the Probe Safely The safety guard ring around the probe body protects your finger against any electric shock, shown as Figure 8-1. Figure 8-1 Finger Guard 10

Warning: To avoid electric shock, always keep your finger behind the safety guard ring of the probe during the operation. To protect you from suffering from the electric shock, do not touch any metal part of the probe tip when it is connected to the power supply. Before making any measurements, always connect the probe to the instrument and connect the ground terminal to the earth. 11

9. Performance parameters Note: "I" indicates the model has the power supply isolation and earth ground isolation between the oscilloscope and PC (optional), the two channels are non-isolated electrically. "L" indicates LAN port (optional). Model Bandwidth Sample rate Rise time Horizontal Scale(S/div) VDS1022(I) 25 MHz 100 MS/s 14 ns 5ns/div - 100s/div, step by1-2-5 VDS2052(I) 50 MHz 250 MS/s 7.0 ns 5ns/div - 100s/div, step by1-2-5 VDS2062(L) 60 MHz 500 MS/s 5.8 ns 5ns/div - 100s/div, step by1-2-5 VDS3102(L) 100 MHz 1 GS/s 3.5 ns 2ns/div - 100s/div, step by1-2-5 VDS2064(L) 60 MHz 500 MS/s 5.8 ns 5ns/div - 100s/div, step by1-2-5 VDS3104(L) 100 MHz 1 GS/s 3.5 ns 2ns/div - 100s/div, step by1-2-5 Sampling mode Sample, Peak detect, Average VDS1022(I) Channel Max Record length Input coupling Input impedance Max. input voltage VDS2052(I) VDS2062(L) 2 + 1 (MULTI port) VDS3102(L) VDS2064(L) VDS3104(L) 4 + 1 (MULTI port) VDS1022(I) VDS2052(I) 5 k VDS2062(L) 10 M VDS3102(L) VDS2064(L) 5 M VDS3104(L) DC, AC, Ground 1 MΩ ± 2%, in parallel with 15 pf ± 5 pf VDS1022I 400 V (PK-PK) (DC + AC PK-PK) VDS2052I VDS1022 VDS2052 VDS2062(L) VDS2064(L) VDS3102(L) VDS3104(L) DC gain accuracy ±3% VDS1022(I) VDS2052(I) VDS2062(L) Vertical sensitivity VDS2064(L) VDS3102(L) VDS3104(L) 40 V (PK-PK) (DC + AC PK-PK) 5 mv/div 5 V/div 2 mv/div 5 V/div 12

Trigger type Trigger mode Line/field frequency (Video) Automatic measurement Waveform Math Communication interface Power supply Dimension Weight Edge, Video, Slope, Pulse, Alternate Auto, Normal, Single Support standard NTSC, PAL and SECAM broadcast systems Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, Delay A B, Delay A B, +Width, -Width, +Duty, -Duty +, -,,, FFT VDS1022(I) VDS2052(I) USB 2.0 Full Speed VDS2062(L) VDS3102(L) VDS2064(L) USB 2.0 High Speed, LAN (optional) VDS3104(L) VDS1022(I) VDS2052(I) 5.0 V/500 ma Power consumption < 2.5 W VDS2062(L) VDS3102(L) VDS2064 5.0 V/1 A Power consumption < 5 W VDS3104 VDS2064L VDS3104L 5.0 V/1.5 A Power consumption < 6.5 W VDS1022(I) 170 mm 120 mm 18 mm (L*H*W) VDS2052(I) VDS2062(L) VDS3102(L) 190 mm 120 mm 18 mm (L*H*W) VDS2064(L) VDS3104(L) About 0.26 kg 13

10. Appendix Appendix A: Enclosure Standard Accessories: Passive probe: 1.2 m, 1:1 (10:1) (2 for dual-channel, 4 for four-channel) 1x CD (Supplied Software) 1x USB cable 1x Quick Guide 1x AC-DC adapter (only for the model with LAN port) Options: 1x Soft case Appendix B: General Care and Cleaning General Care To avoid any damage to the instrument or probe, do not exposed it to any sprays, liquids, or solvents. Cleaning Inspect the instrument and probes as often as operating conditions require. To clean the instrument exterior, perform the following steps: 1. Wipe the dust from the instrument and probe surface with a soft cloth. 2. Disconnect the USB cable before cleaning your Oscilloscope. Clean the instrument with a wet soft cloth not dripping water. It is recommended to scrub with soft detergent or fresh water. To avoid damage to the instrument or probe, do not use any corrosive chemical cleaning agent. Warning: Before power on again for operation, it is required to confirm that the instrument has already been dried completely, avoiding any electrical short circuit or bodily injury resulting form the moisture. 14