Data sheet: Wilo-Stratos 40/1-8

Data sheet: Wilo-Stratos 50/1-10

Data sheet: Wilo-Stratos 30/1-8

Data sheet: Wilo-Stratos 50/1-9

2CP. Centrifugal twin-impeller pumps

Standardised EN 733 centrifugal pumps

MAX FLUID TEMPERATURE

Series description: Wilo-MultiCargo HMC

JVMG* *NSF 61/Annex G Certification and Compliance with State Codes does not apply to JVMG Models

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

BARE SHAFT PUMPS AND MOTOR PUMPS

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution

Submersible Pumps. Pumping Solution. 50 Hz

IMMERSON S6. SUBMERGED BOREHOLE PUMPS Domestic - Agriculture - Industry 50 Hz OPERATING RANGES APPLICATIONS ADVANTAGES. Certified

TD End-Suction Pumps. Operating data Flow rates up to 300 l/sec Head up to 160 metres Temperature 20 0 C to C

8 Submersible Motors Hi-Temp 75

4" MULTISTAGE CENTRIFUGAL SUBMERSED PUMPS COMPLETE WITH MOTOR

shop online:

Close-coupled centrifugal pumps

L P Linn-Pumpen GmbH. Submersible Vertical Electric pumps. SVI Series. with high efficiency PLM motors. SVI Series MARKET SECTORS INDUSTRIAL, CIVIL.

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control

ASTRO 2 CIRCULATORS. ASTRO 2 3-Speed Circulators (except Astro 286):

L P Linn-Pumpen GmbH. Electric-gear-pumps series FKM

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

CR, CRN high pressure

8 Submersible Motors Standard

ASTRO CIRCULATORS. IRON BODY CONSTRUCTION Model No. Part No. Connection List Price Wt.ea.lbs. ASTRO

SUBMERSIBLE PUMPS SEWAGE RANGE

Level sensor Stainless steel version Model RLT-1000, for industrial applications

CM - DCM GENERAL DATA. Applications. Constructions features

E SERIES CIRCULATORS

Temperature Switches

KVC / KVCX GENERAL DATA. motralec VERTICAL MULTISTAGE PUMPS

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

NSF/ANSI 61 Drinking Water System Components - Health Effects

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

4W 50Hz 2900 RPM Noryl Pump

HANKIA. DSV type. Single stage,vertical Axially split case double suction pump

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Screw-Type Flow Meter SVC

Lenntech BMP GRUNDFOS DATA BOOKLET. High-pressure piston pumps 50/60 Hz

Spectrum 500D 3/4 gpm Functional Specifications Physical Specifications Standards Spectrum 500D (3 or 4 )

Lenntech GRUNDFOS DATA BOOKLET. CME 10. Horizontal, multistage centrifugal pumps 50/60 Hz

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

Model RFM. Model RFM. Materials and Specifications. Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" Features 1" RFM 50 2" RFM 160

Technical Specification _5.0. Concertor N/EA/DP

CR, CRI, CRN, CRE, CRIE, CRNE

imag 4700 Series FLANGED MAGMETER

SUCTION FILTERS. PRESSURE (ISO :2002) Collapse, differential for the fi lter element (ISO 2941): 1 MPa (10 bar)

SERIES 1300 Quality Design Features Assure Long, Trouble-Free Service

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Continuous level measuring system NB 3000 Selection list

Inductive Cylinder Position Sensors

Axially Split Volute Casing Pump RDLO / RDLO V. Type Series Booklet

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Level Measurement Continuous level measurement - Ultrasonic transducers

FLS F3.00 PADDLEWHEEL FLOW SENSOR APPLICATIONS MAIN FEATURES

Electronic pressure switch with display Model PSD-4

A Guide To Using. > WebCAPS. Grundfos International Version

LCC Pump Series - Wear Resistant, High Performance Slurry Pumps

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet December 2014 IP207, Rev DA

Rotary Position Technology Incremental Encoders

Mobrey Squitch 2. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP207, Rev DB

EC centrifugal module - RadiPac

SERIES 4360 "VERTICAL" OR MOTOR MOUNTED PUMP CENTERLINE DISCHARGE "D" DESIGNATION PARTS LIST 1-1/4" IMPELLER BORE /8" MECHANICAL SEAL NEW DESIGN

ZMD ZMDV. AXIALLY SPLIT, ONE-STAGE, BETWEEN-BEARINGS PUMPS 50/60 Hz. High reliability and efficiency. Wide range of material options

1 - "F3" means special seals for fire-resistant fluids. Omit if not required

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

Spectrum 175D. meter performance with no maintenance.

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

Immersion Temperature Sensors

Jockey Pump Controllers

EC centrifugal fan - RadiPac

Rotary Position Technology Incremental Encoders

imag 4700 Series FLANGED MAGMETER

Electromechanical pressure switches

Jockey Pump Controllers

Compact Bellows Pumps

F3 BHQ 4 67 D 1 A

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols

Shaft Seal. Accessories

IC Series Constant Pressure Inverter Control System

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

Screw-in resistance thermometers with terminal head Form B

Flow Measurement SITRANS F M

Screw-Type Flow Meter SVC

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

Series DMHF Heat Meter

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

MAG. ECO FLO imag Series NSF FEATURES

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Electronic Oil Meter OM 20

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Absolute Rotary Encoder EXAG Explosion Proof. Profibus-DP

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Flow Measurement SITRANS F M

Transcription:

Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match flow requirements >Applications: Domestic hot water circulation systems, and related "open" systems (e.g. cooling water circulation) >Special features/product advantages: Pre-selectable speed adjustment Wet rotor, NSF approved type 3 1 1 3 Q[m³/h] 1.x x x x3 Hz - North America 3x3 1 1 1 As at: 3/ - Subject to change without prior notice

Product review Function, equipment... 1.x1 1.x x x3 x 3x3 Operating modes Pre-selectable speed stages for optimum load adjustment Manual functions Number of speeds Signal and display functions Thermal overload sensor (NC contact) Power on light Reverse rotation light (only with 3~ pumps) Equipment/Scope of delivery (only with 3~ pumps) (only with 3~ pumps) (only with 3~ pumps) Pump Flange gaskets Power cable connection from either side of terminal box Cast alunimum terminal box with threaded NPT electrical opens on both sides Cable entry gaskets Installation and operating instructions = available, = not available

Product review Technical data Approved fluids (other fluids on request)... 1.x1 1.x x x3 x 3x3 Heating water Water/glycol mixtures ( 1:1; mixtures with more than % glycol require reassessment of the hydraulic criteria) Domestic hot water for secondary and service water systems Performance Max. delivery head [ft] 1~ 1. 19.7.3. 9.9 3~ 19.7 3.,9 3.7.9 Max. delivery head [m] 1~.... 9.1 3~. 7.. 11.. Max. volume rate of flow [USGPM] 1~ 9.. 17. 1. 13.3 3~.9 17. 19. 1.7. Max. volume rate of flow [m 3 /h] 1~ 13. 1.. 7.3 3. Acceptable field of application 3~ 1.. 9. 3..3 Temperature range for application in heating and cooling installations (closed circulating systems) Temperature range for open circulating systems Temperature range for use in drinking-water circulation systems Max. permitted hardness in drinking-water circulation systems [gr/us gal] Ambient temperature range Max. working pressure p max 1 F (-1 C) up to 17 F (+ C) 1 F (-1 C) up to 1 F (+ C) 3 F ( C) up to 17 F (+ C) 1. 1. 1. 1. 1. 1. 1 psi (1 bar) 1 psi (1 bar) 1 psi (1 bar) 3 F ( C) up to 1 F (+ C) 1 psi (1 bar) 1 psi (1 bar) 1 psi (1 bar) Pipe connections Nominal connection diameter [in] 1. 1. 3 Non ANSI flange (oval, rotated 9 ) Non ANSI flange (oval) Non ANSI flange (round) 1 # raised face ANSI flange = available, = not available 3 As at: 3/ - Subject to change without prior notice

Product review Technical data... 1.x1 1.x x x3 x 3x3 Electrical connections Power supply 1~ [V] 11 11 11 11 3 3 3 3 3 Power supply 3~ [V] -3-3 -3-3 -3 7 7 7 7 Frequency [Hz] Motor/Electronics Degree of protection Enclosure Insulation class H H H H H H Materials Pump housing Lead free "eco-bronze" Impeller (PPE) (PPS-% GF) (PPS-% GF) (PPS-% GF) (PPS-% GF) (PPE) Shaft Stainless steel (X39 CrMo17-1) Bearing Carbon (synthetic resin impregnated) Minimal static inlet pressure at pump suction port [psi] to avoid cavitation at fluid temperatures 1 F ( C) 7.1 7.1 11. 11. 11. 11. 17 F ( C) 11. 11. 1. 1. 1. 1. = available, = not available

Pump curves 1.x1 1~ (single phase motor) Note: The solid line of the following hydraulic curves indicates the 1 1 permitted range of performance 1 1.x1 Hz - North America 1 3 1 1 3, 1 1,, 3 3, 1 1....1 1 3..1.1.1.1 1.x 1.x 1~ (single phase motor) 3~ (three phase motor) 1 1 1 1 1 1 1.x Hz - North America 1.x Hz - North America 1 1 1 3 1 3 1 1 1 3 1 3 1 3 1 1 1..3..3....1 1 3..3. 1 3 1 1 1.1 1 3...1.1 As at: 3/ - Subject to change without prior notice

Pump curves x x 1~ (single phase motor) 3~ (three phase motor) 1 1 1 1 x Hz - North America x Hz - North America 1 1 1 1 1 1 1 3 7 1 3 7 1 1 1 1..7... 1....3... 1...3. x3 x3 1~ (single phase motor) 3~ (three phase motor) 1 1 1 1 3 3 x3 Hz - North America 3 x3 Hz - North America 1 1 1 1 1 1 1 1 3 7 1 1 1 1 3.... 1....... 1 1....

Pump curves x x 1~ (single phase motor) 3~ (three phase motor) 1 1 3 1 1 3 3 3 3 x Hz - North America 1 x Hz - North America 1 3 1 1 1 1 1 1 1 1 1 1 3 1. 1. 1. 1 1.. 1 1 1 1 1 3 3 1. 1.. 1 1 1. 1.. 3x3 3~ (three phase motor) 1 3 3 3x3 Hz - North America 1 1 1 1 1 1 1 3 1. 1... 1 1 1... 7 As at: 3/ - Subject to change without prior notice

Wiring diagrams Wiring diagram A - single phase motor -pole, 1~11/3 V, Hz Wiring diagram B - three phase motor -pole, 3~-3//7 V, Hz L N L1 L L3 S1 S P1 P N L S1 S P1 P L1 L L3 1~ 3~ Note: The pump must be connected to the electrical supply via an external contactor to provide thermal overload protection. Note: The pump must be connected to the electrical supply via an external contactor to provide thermal overload protection.

Motor data Motor Data single phase motor... Rated Power Speed Power consumption 1.x1 1 / 9 1.x 1/ 1 x / x3 / x 1 11 Current Capacitor Screwed cable gland Wiring diagram P (at high speed) n 1~11 V 1~3 V 1~11 V 1~3 V I [W] [rpm] [W] [A] [μf/vdb] [in] 31 1 1.9 1. 19 1..9 33 9. 1. 3,7 1.3 3.9 3. 3 7.7. 33 7 7. 3. 31 7 7. 3. 33 19. 9 119.7 / / / / / 1/ / 1/ 3/ x ½" x ¼" x ½" x ¼" x ½" x ¼" x ½" x ¼" x ½" x ¼" A A A A A Motor Data three phase motor... Rated Power Speed Power consumption 1.x 1/ 1 x / x3 / x 1 1 / 11 3x3 1 1 / 11 Current Screwed cable gland Wiring diagram P (at high speed) n 3~-3 V 3~ V 3~7 V I [W] [rpm] [W] [A] [in] 33 31 1. x ½".7 x ¼" 33 7. 1.. x ½" 7 1... x ¼" 39. 1. 1.1 x ½" 7 1 1..9.7 x ¼" 33 13... x ½" 9 113 3.3 1. 1.3 x ¼" 3 13... x ½" 3 1 3. 1. 1. x ¼" B B B B B 9 As at: 3/ - Subject to change without prior notice

Dimensions, weights Drawing no.: 1 Drawing no.: 1/ 1/ l3 l3 l l l 1 l l l 1 1/ 1/ b1 b a a1 b 1 b a a 1 b b Drawing no.: 3 Drawing no.: 1/ 1/ l3 l3 l l l 1 l l l1 1/ b 1 b a a 1 b 1/ b1 b a a1 b Drawing no.: Drawing no.: n x d L Ø D Ø k Ø d DN DN Ø d Ø k Ø D n x d L 1

Dimensions, weights Dimensions, weights... Flange diameter Pump dimensions DN l a 1 a b 1 b b [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] 1.x1 1. 1 / 1 7 11 /1 19 1 /1 3 3 1 / /1 7 /1 113 1.x 1. 1 7 11 /1 19 3 / 1 3 1 /1 7 11 /1 7 /1 113 x. 11 79 9 9 /1 3 1 / 3 9 /1 91 3 7 3 / 1 x3. 11 79 9 9 /1 3 1 / 3 9 /1 91 3 7 3 / 1 x. 13 1 / 33 11 7 /1 9 3 7 /1 1 / 1 3 9 /1 9 1 / 13 3x3 3. 1 3 1 1 / 1 3 3 / 9 7 /1 11 3 7 /1 1 / 13 Dimensions, weights (continuation)... Pump dimensions Weight approx. net Drawing No. l 1 l 3 l 1~ 3~ 1~ 3~ [in] [mm] [in] [mm] [in] [mm] [lbs] [kg] [lbs] [kg] 1.x1 1 / 1. 3 / 7 3 / 7 1..9 1 1.x 17. 3 / 7 3 / 7.3 1.1. 1. 1 x 1 / 139. 3 / 7 3 / 7 3. 1.7 3. 1. 3 x3 1 / 139. 3 / 7 3 / 7 3. 1.7 3. 1. 3 x 3 / 171. 3 / 7 3 / 7.1...7 3 3x3 7 17. 3 / 7 3 / 7 7. 3.1 Flange dimensions... Flange Nominal diameter 1.x1 1.x x x3 x 3x3 Flange dimension pump Drawing No. DN Ø D Ø d Ø k n x d L - [in] [mm] in [mm] [in] [mm] [in] [mm] [units x in] [units x mm] - Non ANSI (oval) 1. 3 / 11 7 / 73 3 1 / 9 x ø 1 / x ø 1 Non ANSI (round). 1 / 133 3 7 /1 7 1 x ø 1 / x ø 1 1 # raised face ANSI flange 3. 7 9 /1 19 1 /1 1 1 x ø 3 / x ø 19 11 As at: 3/ - Subject to change without prior notice